Final Adjustment and Regulating Procedures
Install Cover
Install cover with two (2) security screws as shown.
Latching
Speed Range
Closing Speed
Range
Delayed
Action Range
Backcheck
Range
+-
Increase
Power Decrease
Power
Counterclockwise
(CCW)
Clockwise
(CW)
1/4" Allen Spring Power
Adjusting Screw
Adjust closing power to the minimum force required to reliably close and latch door.
yIf door is hard to open, decrease power slightly.
yIf door does not latch, increase power as required.
yUse chart below as a starting point.
yDoors adjusted with high closing power to overcome strong
draft conditions may exceed ADA standards.
Door Width
in inches
Exterior Doors Interior
Doors *
24 - 30 2 - 7 turns CW 1-5 turns CCW
30 - 36 7 - 11 turns CW 3-6 turns CCW
36 - 42 11 - 15 turns CW Factory Set
42 - 48 15 -17 turns CW 8 turns & Up CW
* If interior doors do not have to comply with ADA requirements, exterior settings
are recommended. Where strong drafts exist, increase spring power as needed.
NOTES:
‒Adjusting door to close due to high draft conditions may
exceed ADA standards.
‒Consult local ordinances when fire doors are involved.
To Adjust Holder Arm (CPSH Arm ONLY)
Adjusting Nut
All CPSH arms are shipped in Non-Hold Open from
the factory. To set in Hold Open, turn the adjusting nut
approximately 1-1/2 turns clockwise.
yRecommend 6 second minimum from 90° to the closed position.
yClosing and Latching Speeds: Turn valves clockwise to slow down or counterclockwise to speed up door movement.
yBackcheck: To regulate the intensity of backcheck action, turn valve clockwise to increase or counterclockwise to decrease check-
ing. CAUTION: Set valve for slight cushioning effect; Closer can be damaged if the checking action is too abrupt. Never use the
backcheck as a door stop. Always use a door stop to stop the door.
yDelayed Action Feature (Optional on some models): Delayed action provides slow door closing through the delayed action range.
Turn valve clockwise to slow down or counterclockwise to speed up door movement.
Insert is
removable.
Place in unused
opening.
Latching
Speed Valve
Closing Speed
Valve
Delayed
Action Valve
(Optional)
Backcheck
Valve
1/4" Spring Power
Adjustment Screw
Decrease
( – )
Increase
( + )
Faster
( + )
Slower
( – )
Use hex socket (1/8” Allen) wrench to adjust Latching Speed,
Closing Speed, and Delayed Action valves.
To regulate the intensity of backcheck action, use hex
socket (1/8" Allen) to turn valve clockwise to increase or
counterclockwise to decrease checking
3
1-800-727-5477 • www.sargentlock.com
281 Series
Installation Instructions
Door Closer with CPS/CPSH Arms
Copyright © 2022, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission ofSARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents.
A7319F 12/22 Rev 6
Approved 2022-12-08