ASSA ABLOY, the global leader
in door opening solutions
Programming Instructions
ASSA Coded 1.2
BASICS
• Coded 1.2 has four accessible Code levels:
– Master Code
– Group Code
– User Code
– Caretaker Code
• Coded 1.2 comes with two factory preset codes:
– Master Code: 11 33 55 77
– User Code: 22 44
– These should be replaced immediately after installation
of the lock
• Master Code and Group Code are 8 digits long
• User Code is 4 digits long
• Caretaker Code is 6 digits long
• The lock’s “open time” is set to 4 seconds
FUNCTIONS
Before beginning to program, choose the most appropriate
function for the application.
A) Repeated use
This is the most common function and is used where the
same Code will be used repeatedly. NOTE! This function is
the default in the lock.
B) Single use
The User enters any Code each time of use with which the
door can be locked and opened one time. The Code is then
deleted so the next User is free to choose a personal Code.
This function is for short-term use, such as a locker at a shop,
museum, or similar.
INSTRUCTIONS FOR USE
ASSA Coded 1.2 consists of a 10-key keyboard and a pro-
gramming key (#). The key is only used for programming and
operates when the lock is programmed for
A) repeated use. The key is hidden behind the handle when
the lock is in locked position.
Blue LED = Code accepted
Red LED = Code rejected
CODES
The lock has the following Code levels:
• Master Code
Master Code lets you:
– Open the lock
– Change Master Code
– Set/change/delete Group Code and User Code
– Choose between A) Repeated use and B) Single use
– Enable/disable Caretaker Code
– Enable/disable the sound by pressing the key (buzzer)
• Group Code
Group Code lets you:
– Open the lock
– Change the Group Code
– Set/change/delete User Code
• User Code
User Code lets you:
– Open the lock
– Change the User Code
• Caretaker Code
Caretaker Code lets you:
– Open the lock in caretaker mode (open the lock without
deleting User Code in B)Single-User mode
NOTE! The same Code cannot be programmed into more
than one level.
Forgotten Code
NOTE! The procedure requires the door to be open.
1. Remove the rear mounting screws and remove the lock
from the door
2. Remove a battery
3. Press and hold the 1 key, insert the battery: The blue LED
will now blink two times, then release the 1 key. Within
three seconds, press the 1 key three times. The blue LED
will now blink two times and the lock will revert to the
factory setting (master key Code 11 33 55 77, all stored
settings will be deleted)
Standby mode
If three incorrect codes are entered one after the other, the
lock is automatically set to standby mode for 10 seconds.
BATTERY OPERATION
ASSA Coded 1.2 should provide well over 50,000 openings,
4 seconds each, from 2 x AAA 1.5V cells.
Weak battery
When the battery is low, the red LED blinks three times be-
fore the blue LED blinks to show that the Code has been ac-
cepted. Replace with new batteries as soon as this happens.
End of battery
The lock is designed so that a PP3 battery can be placed
against the external contacts under the handle to provide
enough energy to open the lock and replace the bad bat-
teries. The procedure is as follows:
• Place the contact points of the PP3 battery against the
contact points on the bottom of the lock; ensure that
contact is maintained throughout the procedure
• The positive +PP3 terminal is connected to the + contact
on the lock, and the negative -PP3 terminal is connected
to the negative contact on the lock. See the mark on the
underside of the lock
• Enter Master Code
• The lock will now be enabled so that it can be opened
• Remove the lock from the door and switch to new
batteries; refit the lock
ASSA ABLOY, the global leader
in door opening solutions
Programming Instructions
ASSA Coded 1.2
PROGRAMMING THE LOCK
• Each programming command must be initiated by
pressing the (#) key, since the lock is in B) repeated use
mode (factory setting), followed by either the Master
Code, Group Code or User Code
• When the lock is in B) single-user mode the (#) key does
not have to be pressed for programming. Just make sure
that the lock does not have a User Code programmed
• If necessary, the (#) key can be used to delete a previous
incorrect entry.
• To enter a valid Code the maximum time allowed between
each key press is 10 seconds, otherwise the Code will be
deleted
COMMANDS ACCESSIBLE WITH MASTER CODE
(#) – Refers to pressing the Program key
(*) – Refers to blue blinking from LED
Change Master Code
(#) Master Code (*) 01 (*) New Master Code (*)
New Master Code (*) (*)
Example: (#) 11335577 (*) 01 (*) 12345678 (*)
12345678 (*) (*)
Result: Master Code 12345678 is now operational
Note: (#) is not required in mode B) Single-user mode
Set or change User Code
(#) Master Code (*) 02 (*) User Code (*)
Example: (#) 11335577 (*) 02 (*) 1455 (*) (*)
Result: New User Code 1455 is now operational
Delete User Code
(#) Master Code (*) 03 (*) (*)
Example: (#) 11335577 (*) 03 (*) (*)
Result: User Code is deleted
Set or change Group Code
(#) Master Code (*) 04 (*) Group Code (*)
Group Code) (*) (*)
Example: (#) 11335577 (*) 04 (*) 22446688 (*)
22446688 (*) (*)
Result: Group Code 22446688 is now operational
Note: (#) is not required in mode B) Single-user mode
Delete Group Code
(#) Master Code (*) 05 (*) 05 (*) (*)
Example: (#) 11335577 (*) 05 (*) 05 (*) (*)
Result: Group Code is deleted
Note: (#) is not required in mode B) single-user mode
COMMANDS ACCESSIBLE WITH GROUP CODE
(#) – Refers to pressing the Program key
(*) – Refers to blue blinking from LED
Change Group Code
(#) Group Code (*) 06 (*) New Group Code (*)
New Group Code (*) (*)
Example: (#) 22446688 (*) 06 (*) 11335500 (*)
11335500 (*) (*)
Result: Group Code has been changed to 11335500
Note: (#) is not required in mode B) Single-user mode
Set or change User Code
(#) Group Code (*) 07 (*) User Code (*) (*)
Example: (#) 11335500 (*) 07 (*) 9999 (*) (*)
Result: New User Code 9999 is now operational
Delete User Code
(#) Group Code (*) 08 (*) (*)
Example: (#) 11335500 (*) 08 (*) (*)
Result: User Code is deleted
COMMANDS ACCESSIBLE WITH USER CODE
(#) – Refers to pressing the Program key
(*) – Refers to blue blinking from LED
Change User Code in mode a) Repeated use
(#) User Code (*) New User Code (*)
New User Code (*) (*)
Example: (#) 2244 (*) 5541 (*) 5541 (*) (*)
Result: User Code changed to 5541
Change User Code in mode B) Single-user mode
Enter CODE to lock (*)
Enter the same CODE to open (*) (*)
NOTE!
1. When the lock is opened with a Code in single-user mode,
the Code is deleted and the lock will be ready for a new
Code
2. When the lock is locked in single-user mode, the red LED
light blinks every two seconds
3. The keypad is active only when the handle is in upright
position
SPECIAL COMMANDS ACCESSIBLE WITH MASTER CODE
(#) – Refers to pressing the Program key
(*) – Refers to blue blinking from LED
Change from a) repeated use to B) Single use
(#) Master Code (*) 09 (*) (*)
Example: (#) 11335577 (*) 09 (*) (*)
Result: The lock now works in mode B) single use. NOTE!
1. The keypad is now inactive when the handle is in open
position
2. Only Master Code and Group Code will be retained from
A) Repeated use.
ASSA ABLOY is the global
leader in door opening solutions,
dedicated to satisfying
end-user needs for security,
safety and convenience
ASSA OEM AB
P.O. Box 371
SE-631 05 Eskilstuna
Sweden
Phone +46 (0)16 17 70 00
Fax +46 (0)16 17 71 77
Customer support:
Phone intl. +46 (0)16 17 70 00
kundservice.etuna@assaoem.se
www.assaoem.se
ASSA ABLOY, the global leader
in door opening solutions
We reserve the right to correct any printing errors and update the information after printing.M3296.1404
Programming Instructions
ASSA Coded 1.2
Limited time locked
(#) Master Code (*) 10 (*) (maximum number of hours the
lock remains locked) (*) (*)
Example: (#) 11335577 (*) 10 (*) 04 (*) (*)
Result: The lock will automatically be opened after 4 hours.
If the lock is opened within 4 hours and a new User Code is
entered, the clock starts over and the time interval is once
again 4 hours.
NOTE! This program will only work when the lock has been
set to B) single use. The maximum number of hours that the
lock may remain locked, written as two digits, is 02, 03, 06,
08, 10 or 12.
Change from B) Single use to A) Repeated use
Master Code (*) 11 (*) (*)
Example: 11335577 (*) 11 (*) (*)
Result: The lock reverts to A) Repeated use with standard user
Code 2244 active until the lock is reprogrammed
NOTE! When the program is changed from B)Single use to
A) Repeated use the latch must be moved to locked status and
previous codes are deleted. The (#) key will now be required
for programming.
Enable Caretaker mode
Master Code (*) 12 (*) Caretaker Code (*)
Caretaker Code (*) (*)
Example: 11335577 (*) 12 (*) 555555 (*) 555555 (*) (*)
Result: The lock is set in caretaker mode Code 555555.
NOTE!
1. Caretaker Code is only accessible in B) Single-user mode
2. Caretaker Code can open the lock without deleting the
single-user Code
3. Opening lock with master Code deletes user Code
Disable caretaker mode Master Code (*) 13 (*) 13 (*) (*)
Result: Caretaker Code is deleted
Enable/disable buzzer
By default, the buzzer is enabled each time the key is
pressed. To disable the buzzer, set the following Code
sequence:
Master Code (*) 14 (*) 14 (*) (*)
Result: No sound is heard when the keys are pressed. To
enable the buzzer, repeat the above Code sequence.

Other Assa Abloy Lock manuals

Assa Abloy Medeco XT User manual

Assa Abloy

Assa Abloy Medeco XT User manual

Assa Abloy 840C-50 User manual

Assa Abloy

Assa Abloy 840C-50 User manual

Assa Abloy effeff EX118R User manual

Assa Abloy

Assa Abloy effeff EX118R User manual

Assa Abloy Sargent PASSPORT 1000 P1 User manual

Assa Abloy

Assa Abloy Sargent PASSPORT 1000 P1 User manual

Assa Abloy Sargent L980S User manual

Assa Abloy

Assa Abloy Sargent L980S User manual

Assa Abloy Sargent XC Series User manual

Assa Abloy

Assa Abloy Sargent XC Series User manual

Assa Abloy Corbin Russwin IN120 User manual

Assa Abloy

Assa Abloy Corbin Russwin IN120 User manual

Assa Abloy Yale P113 User manual

Assa Abloy

Assa Abloy Yale P113 User manual

Assa Abloy HES 5000 Series Manual

Assa Abloy

Assa Abloy HES 5000 Series Manual

Assa Abloy eCLIQ User manual

Assa Abloy

Assa Abloy eCLIQ User manual

Assa Abloy SARGENT 1655 User manual

Assa Abloy

Assa Abloy SARGENT 1655 User manual

Assa Abloy MGL-01500ALS Series User manual

Assa Abloy

Assa Abloy MGL-01500ALS Series User manual

Assa Abloy PULSE PK200 User manual

Assa Abloy

Assa Abloy PULSE PK200 User manual

Assa Abloy Yale Y-LL67AP User manual

Assa Abloy

Assa Abloy Yale Y-LL67AP User manual

Assa Abloy 1048.10 Guide

Assa Abloy

Assa Abloy 1048.10 Guide

Assa Abloy Corbin Russwin IN100 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin IN100 Series User manual

Assa Abloy APERIO E100 Scand User manual

Assa Abloy

Assa Abloy APERIO E100 Scand User manual

Assa Abloy SARGENT Profile LK Series Installation manual

Assa Abloy

Assa Abloy SARGENT Profile LK Series Installation manual

Assa Abloy Sargent Passport 1000 PG User manual

Assa Abloy

Assa Abloy Sargent Passport 1000 PG User manual

Assa Abloy Securitron Vista V2M1200 Series User manual

Assa Abloy

Assa Abloy Securitron Vista V2M1200 Series User manual

Assa Abloy INTERLOCK P84166 User manual

Assa Abloy

Assa Abloy INTERLOCK P84166 User manual

Assa Abloy Yale Real Living Real Living YRC246 Technical specifications

Assa Abloy

Assa Abloy Yale Real Living Real Living YRC246 Technical specifications

Assa Abloy Securitron CEPT-10-10 User manual

Assa Abloy

Assa Abloy Securitron CEPT-10-10 User manual

Assa Abloy Corbin Russwin BLSS ML2000 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin BLSS ML2000 Series User manual

Popular Lock manuals by other brands

Kaba Mauer Combi B 30 Series Mounting instructions

Kaba Mauer

Kaba Mauer Combi B 30 Series Mounting instructions

YARDLOCK SHED LOCK installation guide

YARDLOCK

YARDLOCK SHED LOCK installation guide

Kaba Group Saflok InSync I Usage instructions

Kaba Group

Kaba Group Saflok InSync I Usage instructions

CODELOCKS Kit-Lock KL1100 manual

CODELOCKS

CODELOCKS Kit-Lock KL1100 manual

Schwaiger 715934 user guide

Schwaiger

Schwaiger 715934 user guide

Siegenia-AUBI GEN AS Series operating instructions

Siegenia-AUBI

Siegenia-AUBI GEN AS Series operating instructions

Digilock DAR1-APV1 Product guide

Digilock

Digilock DAR1-APV1 Product guide

EUCHNER ESL-IH-AR operating instructions

EUCHNER

EUCHNER ESL-IH-AR operating instructions

Zap ACC512 quick start guide

Zap

Zap ACC512 quick start guide

LaGrand AUDITGARD Programming Instruction

LaGrand

LaGrand AUDITGARD Programming Instruction

De Raat La Gard 39E operating instructions

De Raat

De Raat La Gard 39E operating instructions

Allegion AD Series manual

Allegion

Allegion AD Series manual

tapplock One+ user manual

tapplock

tapplock One+ user manual

Emtek Classic Installation & programming guide

Emtek

Emtek Classic Installation & programming guide

StarTech.com LTLOCK4D quick start guide

StarTech.com

StarTech.com LTLOCK4D quick start guide

HES 4500 series installation instructions

HES

HES 4500 series installation instructions

Dormakaba digital cylinder Technical manual

Dormakaba

Dormakaba digital cylinder Technical manual

CDVI V1SR quick start guide

CDVI

CDVI V1SR quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.