DAR1-APS1 & DAR1-APV1
Phone: 707 766 6000
www.digilock.com | [email protected]
RFID Locks Advanced Security
Assigned Use
Product Guide
RFID locks operate with an RFID Card. In assigned use functionality, an RFID Card is assigned to operate the lock. The user presents
the assigned RFID Card to unlock and closes the door to automatically lock. Management staff operates the lock with either the
Programming Key unique to the lock system or any registered Manager Bypass Key.
Front Unit
Lock Parts
Vertical Body
DAR1-APV1
Key Slot
Pull Handle
Rear Unit
Vertical Body
Key Insertion
Digilock logo must face up on standard and vertical body locks.
Standard Body
User Key
Operates the lock instead of
RFID Card
ADA compliant*
Keys
Manager Bypass Key
Assigns RFID Card and User Key
Provides lock access in case of forgotten/lost
user credential (card or key)
Allows management audit/inspection
Provides external power in case of battery failure
Up to 25 Manager Bypass Keys may be registered
per lock
Programming Key
Registers Manager Bypass Keys
Provides lock access in case of forgotten/lost user
credential (card or key)
Allows management audit/inspection
1 Programming Key required per lock system *US Access Board requires 5% of all
locks to be ADA compliant.
Advanced Security
Cover Plate
Cover Plate Screws
Mounting Holes
1/2” (12mm) Deadlatch
Key Button
Standard Body
DAR1-APS1
Pull Handle
Key Slot
Reader
Key Button
LED Usage
Indicator
LED Usage
Indicator
Reader
R F I D
CARD
RFID Card
DAR1-APS1 & DAR1-APV1
Phone: 707 766 6000
www.digilock.com | [email protected]
RFID Locks Advanced Security
Assigned Use
Product Guide
Programming Instructions
New locks operate only with `.Locks must be setup to allow full operation.
Manager Bypass Key(s) can be quickly registered to multiple locks. The Programming Key copies the registered Manager Bypass
Key(s) from one lock to multiple locks.
Initial Setup
Express Register
a. Go to the lock registered with the Manager Bypass Key(s).
b. Press and hold `for 10 seconds. After 5 seconds, a two-tone beep will be heard and the LED will start to flash; continue to
hold until two-sets of two-tone beeps are heard.
c. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off.
d. At each lock to be registered, touch the Programming Key to the key slot until a two-tone beep is heard and the LED flashes
once to indicate successful registration.
e. End express registration.* Go to any registered lock and press ` then touch the Programming Key to the key slot to operate
the lock.
Up to 25 Manager Bypass Keys may be registered to a lock. If required, contact your Digilock Product Representative to order
additional Manager Bypass Key(s).
a. Go to a lock requiring Manager Bypass Key(s).
b. Press and hold `for 5 seconds until a two-tone beep is heard and the LED starts to flash.
c. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns on.
d. Touch each Manager Bypass Key to the key slot. A two-tone beep will be heard for each Manager Bypass Key that is
successfully registered.
e. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off.
f. Repeat above steps for each lock or follow Express Register instructions to register the same Manager Bypass Key(s) to
multiple locks.
Register/Add Manager Bypass Key(s)
*The Programming Key will continue to function in express registration mode until it is used to operate a lock.
a. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns on.
b. Touch each Manager Bypass Key to the key slot. A two-tone beep will be heard for each Manager Bypass Key that is
successfully registered.
c. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off.
d. Repeat above steps for each lock or follow Express Register instructions to setup all locks.
For Lost or Stolen Keys
For a lost or stolen Programming Key:
The lost/stolen Programming Key will continue to operate the lock(s) until it is replaced. Immediately order a Replacement
Programming Key from your Digilock Product Representative. Once received, follow enclosed instructions to set up the lock(s) to
operate with the Replacement Programming Key.
For a lost or stolen Manager Bypass Key(s):
Lost/Stolen Manager Bypass Key(s) will continue to operate the lock(s). To prevent the lost/stolen Manager Bypass Key(s) from
operating the lock(s), erase all registered Manager Bypass Key(s) and register only the remaining Manager Bypass Key(s).
a. Collect all remaining Manager Bypass Key(s).
b. Press and hold `for 5 seconds until a two-tone beep is heard and the LED starts to flash.
c. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns on.
d. Touch the Programming Key to the key slot again until three sets of two-tone beeps are heard and the LED turns off.
All previously registered Manager Bypass Key(s) have been erased from the lock.
e. Follow Register/Add Manager Bypass Key(s) instructions to register the remaining Manager Bypass Key(s).
DAR1-APS1 & DAR1-APV1
Phone: 707 766 6000
www.digilock.com | [email protected]
RFID Locks Advanced Security
Assigned Use
Product Guide
Operating Instructions
Operate with the assigned User Key:
To unlock: Touch the assigned User Key to the key slot. The latch will retract for approximately 6 seconds to
allow the door to be opened.
To lock: Close the door.
Operate with a registered Manager Bypass Key:
To unlock: Touch a registered Manager Bypass Key to the key slot. The latch will retract for approximately 6 seconds to allow
the door to be opened.
To lock: Close the door.
Operate with the Programming Key:
To unlock: Press `, then touch the Programming Key to the key slot. The latch will retract for approximately 6 seconds to
allow the door to be opened.
To lock: Close the door.
Operate with the assigned RFID Card:
To unlock: Press ` then present the assigned RFID Card to the Reader. The latch will retract for approximately 6 seconds
to allow the door to be opened.
To lock: Close the door.
*Once a User Credential is assigned, the previous User Credential will no longer operate the lock.
a. Press and hold `for 5 seconds until a two-tone beep is heard and the LED starts to flash.
b. Touch a registered Manager Bypass Key to the key slot until a two-tone beep is heard and the LED turns on.
c. Touch any User Key to the key slot until two sets of two-tone beeps are heard and the LED turns off.
Assign a User Key
Assign User Credential (RFID Card or User Key)*
Assign an RFID Card
a. Press and hold `for 5 seconds until a two-tone beep is heard and the LED starts to flash.
b. Touch a registered Manager Bypass Key to the key slot until a two-tone beep is heard and the LED turns on.
c. Present an RFID Card to the Reader until two sets of two-tone beeps are heard and the LED turns off.
DAR1-APS1 & DAR1-APV1
RFID Locks Advanced Security
Assigned Use
Product Guide
Phone: 707 766 6000
www.digilock.com | [email protected]
Support
Error Condition Indicator
Locks emit feedback when an error condition exists.
2 sets of three beeps:
The batteries are low. Replace the batteries.
1 beep:
The lock does not recognize the RFID Card or Key.
The lock is binding which means that either door alignment or items in the locker are preventing the lock from operating. Press on the
door while operating the lock. If error condition persists, contact Digilock Support for assistance.
10 rapid beeps:
Does not Operate with a Manager Bypass Key
The lock does not recognize the Manager Bypass Key. Follow Register/Add Manager Bypass Key(s) instructions to register Manager
Bypass Key to the lock. For immediate access, operate with another registered Manager Bypass Key or with the Programming Key.
Does not Operate with the Programming Key
The lock does not recognize the Programming Key. Contact Digilock Support for assistance.
Does not Unlock with the RFID Card or User Key
The lock does not recognize the RFID Card or User Key. Follow Assign User Credential instructions to assign an RFID Card to the
lock. For immediate access, operate the lock with a registered Manager Bypass Key.
PG-DAR1-AP-DEN
021314
RFID Locks Advanced Security
No Audible Feedback when `is Pressed
a. The batteries may need to be replaced. For immediate access, touch and hold a registered Manager Bypass Key to the key slot
for approximately 10 seconds to provide external power and operate the lock.
b. If error condition persists, loosen the mounting hardware and test.
c. If error condition persists, remove the lock and assemble in your hand to test. If the door is locked or damage is visible, contact
Digilock Support.
d. If the lock functions when assembled in your hands, reinstall and test again.
e. If error condition persists, contact Digilock Support.
Battery Replacement
It is not necessary to remove the lock mounting hardware or remove the lock from door to change the batteries.
1
The batteries are located in
the rear unit of the lock.
Remove the screws and the
cover plate.
2
Pull the battery pack from the
rear housing.
Replace with four premium
alkaline AA batteries.
3
Place the battery pack back
into the rear housing and
screw cover plate in place.
4

This manual suits for next models

1

Other Digilock Lock manuals

Digilock Lockup M User manual

Digilock

Digilock Lockup M User manual

Digilock Curve User manual

Digilock

Digilock Curve User manual

Digilock numeris aspire User manual

Digilock

Digilock numeris aspire User manual

Digilock NEXTLOCK CUE Series User manual

Digilock

Digilock NEXTLOCK CUE Series User manual

Digilock NEXT Sola3 Keypad User manual

Digilock

Digilock NEXT Sola3 Keypad User manual

Digilock Numeris Versa User manual

Digilock

Digilock Numeris Versa User manual

Digilock Numeris Versa Mini User manual

Digilock

Digilock Numeris Versa Mini User manual

Digilock DCK1-APV1 User manual

Digilock

Digilock DCK1-APV1 User manual

Digilock Assigned Use RFID Camlock User manual

Digilock

Digilock Assigned Use RFID Camlock User manual

Digilock DAK1-APS1 User manual

Digilock

Digilock DAK1-APS1 User manual

Digilock Next Mech Dial Combo User manual

Digilock

Digilock Next Mech Dial Combo User manual

Digilock NEXT Sola3 Keypad User manual

Digilock

Digilock NEXT Sola3 Keypad User manual

Digilock DL330BT User manual

Digilock

Digilock DL330BT User manual

Digilock NEXT Sola3 Touch RFID User manual

Digilock

Digilock NEXT Sola3 Touch RFID User manual

Digilock ATS User manual

Digilock

Digilock ATS User manual

Digilock DCR1-APV1 User manual

Digilock

Digilock DCR1-APV1 User manual

Digilock numeris aspire User manual

Digilock

Digilock numeris aspire User manual

Digilock ADA User Key Owner's manual

Digilock

Digilock ADA User Key Owner's manual

Digilock DAR1-ATS1 User manual

Digilock

Digilock DAR1-ATS1 User manual

Digilock Numeris Versa Standard User manual

Digilock

Digilock Numeris Versa Standard User manual

Digilock DCR1-ATV1 User manual

Digilock

Digilock DCR1-ATV1 User manual

Digilock DK-APS 4G Operating instructions

Digilock

Digilock DK-APS 4G Operating instructions

Digilock Next Mech User manual

Digilock

Digilock Next Mech User manual

Digilock Shared Use RFID Camlock User manual

Digilock

Digilock Shared Use RFID Camlock User manual

Popular Lock manuals by other brands

FireKing ESK18B Operation instructions

FireKing

FireKing ESK18B Operation instructions

Bosch PVA-1KS quick start guide

Bosch

Bosch PVA-1KS quick start guide

Sentrilock REALTOR RAD Getting started guide

Sentrilock

Sentrilock REALTOR RAD Getting started guide

CES OMEGA FLEX Assembly and operating instructions

CES

CES OMEGA FLEX Assembly and operating instructions

Be Cool BCPL22M1 operating instructions

Be Cool

Be Cool BCPL22M1 operating instructions

Simplex 5000 Series Resetting guide

Simplex

Simplex 5000 Series Resetting guide

Schlage B-Series installation instructions

Schlage

Schlage B-Series installation instructions

Bison BA894 instruction manual

Bison

Bison BA894 instruction manual

Abloy EL490 manual

Abloy

Abloy EL490 manual

INSYS CombiLock 200 simplex manual

INSYS

INSYS CombiLock 200 simplex manual

Corbin Russwin Access 800 installation instructions

Corbin Russwin

Corbin Russwin Access 800 installation instructions

Rousseau L50 user manual

Rousseau

Rousseau L50 user manual

ViziT ML240-40 Operating	 instruction

ViziT

ViziT ML240-40 Operating instruction

AMSEC BSL-0601A-W Operating and installation instructions

AMSEC

AMSEC BSL-0601A-W Operating and installation instructions

Robur PS300/E31 user manual

Robur

Robur PS300/E31 user manual

Kaba LA GARD COMBOGARDPRO Manager's guide

Kaba

Kaba LA GARD COMBOGARDPRO Manager's guide

GE TQPPLCP installation instructions

GE

GE TQPPLCP installation instructions

GRASS NOVA PRO Mounting instruction

GRASS

GRASS NOVA PRO Mounting instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.