manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BFT
  6. •
  7. Gate Opener
  8. •
  9. BFT KUSTOS BTA User manual

BFT KUSTOS BTA User manual

Cable run
1Motor fastening
2
3
4
Adjust the limit switches and the stops according to the diagrams, open/closed position.
If necessary, fine-tune the adjustments to be performed upon completion of installation.
Use normalised black cables
R02V - HO5VVF
5x0.75 mm²
3x1.5 mm²
230 v
3x1.5 mm²
2x0.75 mm²
3x1.5 mm²
b
a100 110 120
101401801311911621321021711001
110 112 116 119 121 122 116 110 105102
120 107 110 114 117 120 117 111 106 102
130 103 106 109 113 116 117 113 107 102
140 97 102 105108 112 115113 110 103
150 97 101 104 107 110 113 110 104
160 97 100 104 107 109 110 105
170 96 100 103 106 108 105
180 96 100 103 106 107
190 96 99 102 105
200 96 98 101
210 9598
220 95
130 140 150 160 170 180 190 200 210 220
Z=b-x>60mm
Pa
x
b
S
D
F
2s
kg
C=1190mm
1
2
FERME
1
2
OUVRE
S
(mm)
KUSTOS BT A40
125
kg
(~ 1250 N) 250
kg
(~ 2500 N)
b (mm)
20 130 ÷ 160 170 ÷ 260
30 130 ÷ 170 180 ÷ 260
40 130 ÷ 180 190 ÷ 260
KUSTOS BT A40
a
1210 355
Cu Max
120
110
FC1
(open)
80
80
FC2
(close)
a
Cu MAX
KUSTOS BTA FW ≥ 2.05
Limit switch adjustment (put motor in gear by moving the panel by hand)
For safety warnings, please see complete instruction manual
Programming (see reverse)
Product reserved for professionals
D812966 00903_01 31-05-17
All manuals and user guides at all-guides.com
1
2
How to programme the remote control
How to perform an open/close test by using the remote control.
If they close, switch wiring:
Left Right
M1 : 10&11 / M2 : 14&15
M1 closes second.
3Start an autoset, gate closed.
LED RADIO
FLASHES RADIO
START
x1
S1 S2 S3 S1 S1 OK
Choose the key
LED RADIO
FLASHES
S1
DIP
Function
1Transmitter programming
Selection of sensing bars.
Check photocells.
Secure entry check.
Photocells during closing
ON: Memorise the commands/copy via remote controls already recorded.
OFF : Disables memorizing of transmitters
ON : Input for resistive edge 8K2.
OFF: Entry for sensitive lintel.
ON : Enable safety check
OFF: Deactivate the cell check.
ON : Enable safety check
OFF: Deactivate the sensing check.
ON: Invert the movement during the closure phase only.
OFF: Active on opening and closing; invert the movement during the closure phase.
2
3
4
5
Sets the automation type of operation:
ON = Apartment building
OFF = Residential
ON : Safety edge with active reversal only when closing, when opening the movement stops
OFF : Safety edge with active reversal in both directions
Rapid closure.
ON : Closes 3 seconds after the photocells are cleared
OFF: Rapid closure deactivated.
7
Safety edge input operation
6
Residential / apartment
building operation
8
OFF : Logic not enabled
Hammer during opening
9
Closing limit
switch pressure
10
*factory pre-parameterised
S3 X1
START
S3 X1
STOP
START
=
5s
S1 S S3
S1 S2 S3
SET
SET SET
OK KO
AUTO OPEN AUTO CLOSE
AUTO OPEN AUTO CLOSE
S1 S2 S3 S1 S2 S3
4
mini maxi
+++ +
4
2
1ON
OFF
1
Zara Control board
ELS
Y #
F2 4 AT
F1 1.25 AT
(220-230V)
F1 2.5 AT (120V)
ANT.
ANT
SHIELD
T1 T2 T3 T4
NORWP
FLT2
FLT1
PHOT
STOP
OPEN
START
SW02
SW01
SWC2
SWC1
BAR
10 11
M1
14 15 20 21 28 29 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72 73 74 75
M2
24V
24V -
24V +
24 VSafe+
COM
NO
NO
NC
NC
NC
SW2
-
+
-
+
SW1
JP5 JP2
JP4 +
+
+
+
L N
LN
220-230V ~
*
START
OPEN
COM
PHOT
STOP
FAULT 1
BAR
FAULT 2
S1 S2 S3
RADIO
EER
SET
Safety
devices
Commands
Limit switch
inputs Accessories
power supply
Blinker
Motor
1
2
3
ZARA
24V
2
1TX1 2
1
RX1
4
5
3
50 51 52
70 72 73
DIP3=ON
5
6Fine-tune the adjustments. Motor functions using the potentiometers (T1, T2, T3, T4).
Remember to check
by pressing S2 for 5 sec.
24V
2
1TX1 2
1
RX1
4
5
3
50 51 52
70 72
DIP3=OFF
6
As an option, to go further....
1 - I wish to deactivate the photocells during opening:
3 - I wish to activate pedestrian opening:
Place dipswitch 5 in the ON position.
4 - I wish to adjust the time difference between M1 & M2: This is done by regulating the T4 potentiometer.
2 - I wish to activate and adjust automatic closure:
This is done by regulating the T1 potentiometer.
2
Solenoid
lock
ON : Before opening completely, the gate pushes for approx. 2 seconds as it closes.
This allows the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
ON : Use when there is a mechanical stop in closed position.This function allows leaves
to press against the mechanical stop without the Amperostop sensor interpreting this
as an obstacle. Thus the rod continues its stroke for a few seconds after meeting the
closing limit switch or as far as the mechanical stop. In this way, the leaves come to rest
perfectly against the stop by allowing the closing limit switches to trip slightly earlier.
OFF : Movement is stopped only when the closing limit switch trips: in this case, the
tripping of the closing limit switch must be adjusted accurately
Apartment
building
Residential
Reaction to the START input (wired or radio):
CLOSED Opens
Stops
Opens
Opens Opens
OPEN Closes Closes
Opens
WHILE
CLOSING
STOPS+TCA No effect
WHILE
OPENING
AFTER
STOP
Apartment
building
Residential
Reaction to the OPEN input (wired):
CLOSED Opens
Opens
Opens
Opens Opens
OPEN
Opens
WHILE
CLOSING
Keeps it
open Keeps it
open
No effectNo effect
WHILE
OPENING
AFTER
STOP
Closes Closes
STOPS+TCA No effect
Apartment
building
Residential
Reaction to the PEDESTRIAN input (radio):
CLOSED Opens
partially Opens
partially
Opens
partially Opens
partially
Stops Opens
partially
OPEN
WHILE
CLOSING
WHILE
OPENING
AFTER
STOP
S2
>5s
S1+ S2
>10s
KEYS
Description
S1
S2
S3
Add Start Key
associates the desired key with the Start command.
Add Pedestrian Key
associates the desired key with the pedestrian command.
Confirms the changes made
to parameter settings and operating
Erase List
WARNING! Erases all memorized transmitters
from the receiver’s memory.
Pressed BRIEFLY, it gives the START command.
HELD DOWN (>5 sec.), it activates the AUTOSET function.
2
TRIMMER
Function
T1
T2
Waiting time before automatic closing. 0 120
5 50
0 25
10 100
% Force exerted by leaf
% Slow-down speed
Motor 1 closing delay time [s]
T3
T4
+
mini. +
maxi
3
Testing the direction of opening - running / stop: apply power, motor
engaged and at stroke centre.
Checking the direction of rotation. I press S3, my two motors must open.
Wire the THEA photocells. Wire the DESME photocells.
Please refer to the remote control programming
by pressing S2.
Press the 2 top keys simultaneously
(hidden key). The LED remains fixed
All manuals and user guides at all-guides.com

Other BFT Gate Opener manuals

BFT LEO B CBB DL2 3 230 L02 User manual

BFT

BFT LEO B CBB DL2 3 230 L02 User manual

BFT Cell Box Switch Instruction Manual

BFT

BFT Cell Box Switch Instruction Manual

BFT SUB User manual

BFT

BFT SUB User manual

BFT DEIMOS BT A 600 User manual

BFT

BFT DEIMOS BT A 600 User manual

BFT ARES ULTRA BT A 1000 User manual

BFT

BFT ARES ULTRA BT A 1000 User manual

BFT DEIMOS BT KIT UL User manual

BFT

BFT DEIMOS BT KIT UL User manual

BFT E5 BT A18 User manual

BFT

BFT E5 BT A18 User manual

BFT DAMPY B User manual

BFT

BFT DAMPY B User manual

BFT DEIMOS BT A 600 User manual

BFT

BFT DEIMOS BT A 600 User manual

BFT CELLULA 180 User manual

BFT

BFT CELLULA 180 User manual

BFT ORO User manual

BFT

BFT ORO User manual

BFT E5 BT A User manual

BFT

BFT E5 BT A User manual

BFT PHOBOS N BT User manual

BFT

BFT PHOBOS N BT User manual

BFT LEM7 User manual

BFT

BFT LEM7 User manual

BFT Cell Switch Prime Instruction Manual

BFT

BFT Cell Switch Prime Instruction Manual

BFT SUB User manual

BFT

BFT SUB User manual

BFT LUX User manual

BFT

BFT LUX User manual

BFT FABER BT User manual

BFT

BFT FABER BT User manual

BFT LUX User manual

BFT

BFT LUX User manual

BFT LUX BT 2B User manual

BFT

BFT LUX BT 2B User manual

BFT GIUNO ULTRA BT A50 User manual

BFT

BFT GIUNO ULTRA BT A50 User manual

BFT BOTTICELLI 800 U User manual

BFT

BFT BOTTICELLI 800 U User manual

BFT joint User manual

BFT

BFT joint User manual

BFT PHOBOS N BT User manual

BFT

BFT PHOBOS N BT User manual

Popular Gate Opener manuals by other brands

Chamberlain LiftMaster Professional SL540 Guide

Chamberlain

Chamberlain LiftMaster Professional SL540 Guide

DKS 9200 owner's manual

DKS

DKS 9200 owner's manual

tau speed 2 Use and maintenance manual

tau

tau speed 2 Use and maintenance manual

Cardin Elettronica HL Series instruction manual

Cardin Elettronica

Cardin Elettronica HL Series instruction manual

Nice ROBUS RB400 Instructions and warnings for installation and use

Nice

Nice ROBUS RB400 Instructions and warnings for installation and use

Seco VINCO 600 manual

Seco

Seco VINCO 600 manual

DoorKing Series 9500 Installation & owner's manual

DoorKing

DoorKing Series 9500 Installation & owner's manual

Elvox EI30 instruction manual

Elvox

Elvox EI30 instruction manual

Medva HLR240 BAC-1.3 instruction manual

Medva

Medva HLR240 BAC-1.3 instruction manual

Centurion D10 installation manual

Centurion

Centurion D10 installation manual

FAAC 770 COMPACT manual

FAAC

FAAC 770 COMPACT manual

Dea MAC STING Operating instructions and warnings

Dea

Dea MAC STING Operating instructions and warnings

Viking X-9 Installation instructions and safety information

Viking

Viking X-9 Installation instructions and safety information

Comunello SHOWIN instruction manual

Comunello

Comunello SHOWIN instruction manual

DoorKing 1602-162 manual

DoorKing

DoorKing 1602-162 manual

Erreka JEDI JES100E manual

Erreka

Erreka JEDI JES100E manual

Comunello Automation SWIFT Installation and user manual

Comunello Automation

Comunello Automation SWIFT Installation and user manual

Beninca RI.20T operating instructions

Beninca

Beninca RI.20T operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.