OPERATING INSTRUCTIONS
• Turn on the switch 12 to inject hot water, the switch 13 to inject steam, the switch 14 to
inject detergent.
• Press button C in the handle CVP to get steam and/or detergent. Turn on red switch D to
get hot water.
• Turn the regulator knobs 17 to control steam, detergent and water flow.
• When the the boiler is going to be empty, the pump recharges the boiler with water from
the tank 6. When the tank is empty, a sound alarm is activated. During the alarm the ma-
chine stops working. To continue working, do not switch off the machine, fill in the tank 6
with water (Note: do not use distilled water) and remember to insert its loading hose.
• Press switch E on the handle CVP to operate the exhauster.
• TO GET A BETTER RESULT WE SUGGEST TO COMBINE THE STEAM JET AS
WELL AS THE WARM WATER AND DETERGENT FOR A COMPLETE REMOVAL
OF THE DIRT. COLLECT ALL RESIDUAL WITH THE EXHAUSTER INTO THE
DRUM.
SERVICE
• At the end of every working session, clean the exhauster drum.
• At the end of every working session, clean the detergent pump. Remove the detergent loa-
ding hose from its tank and insert it in the boiler water tank. Press the detergent switch 16
on the handle CVP to get clean water through the pump.
SERVICE II
EMPTYING/CLEANING THE BOILER
• Unplug the machine. When the boiler is cold and not under pressure, open the draining tap
under the machine to pour out the water from the boiler.
• It is not necessary to pour out all remaining water each time you finish cleaning. Do
the emptying/cleaning operations once a month (or more according to the use).
AT THE END OF THE WORKING SESSION, TURN OFF ALL SWITCHES AND
UNPLUG THE BOILER. PUT THE APPLIANCE IN A DRY PLACE.
OPERATING AND SAFETY INSTRUCTIONS
•
After the removal of the package make sure of the appliance’s integrity. In case of
doubt do not operate the appliance but take it to a qualified service person for ex-
amination and repair. Plastic bags, polystyrene, etc…, must be kept out of the chil-
dren’s reach.
•
Before connecting appliance, make sure that data on the plate are the same as the
power supply network. The voltage appliance is of 230V monophasic with a plug
of 16A+T.
•
Plug appliance into grounded outlet of sufficient power as provided for by the
safety regulations in force.
•
Do not touch appliance with wet or damp hands.
•
Always disconnect appliance from electrical outlet when not in use.
•
This appliance is only and exclusively for its intended use so the manufacturer can
not be held responsible for any probable damage due to an illegitimate use.
•
Never unscrew the safety valve cap during use.
•
Before cleaning and maintenance make sure that appliance is disconnected from
outlet. Do not wash the appliance, do not immerse in water. Before filling the
boiler, make sure that appliance is unplugged.
•
In case of failure or operational defect, turn off appliance, disconnect from electri-
cal outlet. Do not disassemble or attempt to repair the appliance. Incorrect re-
assembly or repair could cause a risk of fire, electric shock, or injury to persons
when the appliance is used. Any repair must be executed by qualified service per-
sons authorized by the manufacturer. Ask for exclusive use of original spare-parts.
•
Installation must be executed according to manufacturer’s instructions (space for
ventilation, room temperature).
•
Do not operate appliance with damaged cord or hose, but let it made replaced.
•
Turn off the two boiler switches, and unplug the boiler when finished operating. It
is not necessary to empty the boiler of remaining water. it is important to unscrew
for only 1 turn the safety cap to let the boiler depressurize.
•
Do not remove safety device and protective cover.
•
Do not service while appliance operates.
•
Before servicing make sure that appliance is unplugged from electrical outlet.
•
THE NON-OBSERVANCE OF THE ABOVE OPERATING AND SAFETY IN-
STRUCTIONS COULD PREJUDICE SAFETY.
Have a good job.
This appliance complies with the CE directive 89/392