AMAX
2100 / 3000 / 4000
en User Guide


Table of contents
1Introduction 4
2Arming and Disarming the System 10
2.1 Arming the System 10
2.1.1 Arming in AWAY Mode 10
2.1.2 Arming in STAY Mode 11
2.1.3 Forced Arming 11
2.2 Disarming the System 11
2.2.1 Disarming with Code 11
2.2.2 Disarming with Key Switch 11
3Faults and Tamper Conditions 12
3.1 System Fault or Tamper Analysis Mode LED Keypad 12
3.2 System Fault or Tamper Analysis Mode Text Keypad 12
4System Test 15
4.1 Siren Test 15
4.2 Communication Test 15
4.3 Walk Test Mode 15
5Event Log Recall Mode 16
6Reset the Control Panel 17
7Bypassing 18
7.1 Bypassing Zones 18
8Codes 19
8.1 Add/Change and Delete User Code 19
8.2 Change Individual Code 20
9Keypad Alarm Operation Commands 21
9.1 Keypad Panic Alarm 21
9.2 Keypad Fire Alarm 21
9.3 Keypad Medical Alarm 21
10 Domestic Dialing 22
AMAX Table of Contents | en 3
Bosch Sicherheitsysteme GmbH User Guide 2014.01 | 02 | F.01U.295.569

Introduction
IUI-AMAX4-TEXT
IUI-AMAX3-LED8 IUI-AMAX3-LED16
IUI-AMAX-LED8 IUI-AMAX-LCD8
1
4en | Introduction AMAX
2014.01 | 02 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH

Notice!
In some country versions Installer Code is needed to reset tamper alarm.
Quick Keypad Operation Instructions
Function Command
Default User Code = 2580
D A B S M I
N
Arm / Disarm
AWAY arm [Code] + [#] / [#] (Quick arm) √ √ √ √ √ √
STAY arm [Code] + [*] / [*] (Quick arm) √ √ √ √ √ √
Disarm [Code] + [#] √ √ √ √ √
Display
Display Info (Fault/
Tamper..)
[Code] + [2] [1] + [#] √ √
Bypass
Zone Bypass/Cancel [Code] + [3][1] + [#] + [Zone No] [*] + [#]
(Bypass)
√ √ √ √
[Code] + [3][1] + [#] + [Zone No] [*] + [#]
(Cancel LED)
√ √ √ √
[Code] + [3][2] + [#] + [Zone No] [*] + [#]
(Cancel Text KP)
√ √ √ √
Bypass Inquiry [Code] + [3][3] + [#] (Text KP) √ √ √ √
Bypass Fault/Tamper [Code] + [3][4] + [#] √ √
Reset
Reset [Code] + [6] + [#] √ √
Alarm commands
Keypad Emergency Alarm Long press [1] and [3] or [*] and [#]
Keypad Fire Long press [4] and [6]
Keypad Medical Alarm Long press [7] and [9]
D = Duress User
A = Arming User
B = Basic User
S = Super User
M = Master User
IN = Install User
AMAX Introduction | en 5
Bosch Sicherheitsysteme GmbH User Guide 2014.01 | 02 | F.01U.295.569

Function Command D A B S M I
N
Other Commands
Switch to Main Keypad [Code] + [0][0][0] + [#] (Text KP) √ √ √
Switch to Area 01-16 [Code] + [0][ _ ][ _ ] + [#] √ √ √
Fault/Tamper Inquire [Code] + [2][1] + [#] √ √
Check all Event Log [Code] + [2][2] + [#] (Text KP) √ √
Check EN Event Log [Code] + [2][3] + [#] (Text KP) √ √
Check Dialer Event Log [Code] + [2][4] + [#] (Text KP) √ √
Siren Test [Code] + [4][1] + [#] √ √
Communication Test [Code] + [4][2] + [#] √ √
Walk Test [Code] + [4][3] + [#] √ √
Change / View date / Time [Code] + [5][1] + [#] √
Daylight Saving Time (+1h) [Code] + [5][2] + [#] √ √
Daylight Saving Time (-1h) [Code] + [5][3] + [#] √ √
Add / Delete / Change User [Code] + [5][4] + [#] √ √
Change Individual Code [Code] + [5][5] + [#] √ √
Change Domestic Phone
No.1-4
[Code] + [5][6][#] + [ _ ] + [#] + [ _ _ _ _ _
_ ][#] (Text KP)
√
Call Back [Code] + [5][7] + [#] √ √
Change Language [Code] + [5][8] + [#] + [ _ ] [ _ ] + [#]
01=EN 02=DE 03=ES 04=FR
05=IT 06=PL 07=NL 08=SE
√√
Installer Access [Code] + [7][1] + [#] (Enable)
[Code] + [7][2] + [#] (Disable)
√
System Reset [Code] + [9][9][8][9] + [#] √ √
Installer Program Mode [Code] + [9][5][8] + [#] √
D = Duress User
A = Arming User
B = Basic User
S = Super User
M = Master User
IN = Install User
6en | Introduction AMAX
2014.01 | 02 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH

USER MENU
ARM/DISARM
INSTALLER ACCESS
SYSTEM SETTINGS
INQUIRE
ZN/FLT/TAMP BYPASS
RESET
ARM AWAY
ARM STAY
DISARM
BYPASS FLT./TAMP.
ZONE BYPASS
ZONE BYPASS CANCEL
BYPASS INQUIRE
PRINT ENABLE
FAULT/TAMP INQUIRE
ALL EVENT RECALL
EN EVENT RECALL
EVENT PRINT
DIAL EVENT RECALL
ENABLE INSTALLER
DISABLE INSTALLER
DAYL.SAV.TIME -1h
ADD/CHG USER CODE
CHANGE INDIV CODE
INITIATE CALL BACK
CHANGE LANGUAGE
DAYL.SAV.TIME +1h
Figure 1.1: User Menu
AMAX Introduction | en 7
Bosch Sicherheitsysteme GmbH User Guide 2014.01 | 02 | F.01U.295.569

Keypad Indicators
Keypad Indicator
Icons
Status Definition
1 2 3 ….
ZONE (1-8)
on Zone is triggered.
off Zone is normal.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Zone was alarmed or is in alarm
status.
Slow flash (1 second lights on/1
second lights off)
Zone is manually bypassed or
interior Zone is in STAY arm mode.
AWAY
on System is armed in AWAY mode.
off System not armed in AWAY mode.
Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code
function mode. STAY indicator
flashes simultaneously.
STAY
on System is armed in STAY mode.
off System not armed in STAY mode.
Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code
function mode. AWAY indicator
flashes simultaneously.When
bypass function is performed, the
STAY indicator only flashes.
MAINS
on AC main power is normal.
Slow flash (1 second lights on/1
second lights off)
AC main power supply failed.
FAULTS
on System fault or Tamper condition
is present.
off System is in normal status.
Flashes System fault or Tamper condition
must be acknowledged.
on System is disarmed.
8en | Introduction AMAX
2014.01 | 02 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH

Keypad Sounds
Sound Indicator Definition
One short beep A keypad button has been pressed.
One single one- second beep The requested operation is refused. Incorrect
operation signal.
Two short beeps The system accepted the code. The system executed
the requested function.
One short beep every minute Fault tone, unacknowledged system failure.
One short beep every two seconds Exit time started.
Continued sound – Last 10s on exit time
– Keypad fault/tamper sound (fault/tamper to be
acknowledged)
– Keypad alarm sound
Continuous 0.5 second beep, stops
0.5 seconds
Entry delay time (until alarm ends or system is
disarmed).
AMAX Introduction | en 9
Bosch Sicherheitsysteme GmbH User Guide 2014.01 | 02 | F.01U.295.569

Arming and Disarming the System
Arming the System
Notice!
When the number of incorrect code entries on the keypad reaches a specified limit, the
keypad will automatically lock for 180 seconds and alarm is reported. If the keypad is idle for
1 minute, the system will automatically exit from any operational mode.
Arming in AWAY Mode
Arming the system in AWAY mode is normally performed when you leave the premises and
require that all zones are activated in a ready state to detect an intrusion.
Keypad Arming
There are two methods to arm your system in AWAY mode.
Method 1:
To arm the System in AWAY mode enter your code and press [#].
It beeps twice, the AWAY indicator flashes slow, and exit time starts.
After the exit time, the AWAY indicator turns on.
Method 2:
To arm the System in AWAY mode press and hold [#] until it beeps twice.
The AWAY indicator flashes slow, and exit time starts. After the exit time, the AWAY indicator
is on.
Please contact your installer to enable/disable this function.
Telephone Remote Arming
The user dials the control panel number. The control panel answers the call and issues a long
beep. After the long beep, the user must press the [#] key. When the Panel receives the signal
it will confirm the arming of the control panel with a high tone.
Please contact your installer to enable/disable this function.
Notice!
Telephone arming is possible when the system has only 1 assigned area.
Key Switch Arming
Users can use a key switch to Arm and Disarm the system. When the Key switch is activated,
the AWAY indicator flashes slow and exit time starts. After exit time, the AWAY indicator is lit.
When the Key switch is deactivated, the system is disarmed and Away indicator is off.
2
2.1
2.1.1
10 en | Arming and Disarming the System AMAX
2014.01 | 02 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH

Arming in STAY Mode
STAY Mode is used when you need to arm the perimeter and unused areas of the premises to
detect a would-be intruder, while at the same time being able to move freely within an area
that is automatically isolated.
There are two methods to arm your system in STAY mode.
Method 1:
To arm the system in STAY mode enter your code and press [*].
It beeps twice, the STAY indicator flashes slow and exit time starts. After exit time, the
STAY indicator is on.
The lights corresponding to all zones programmed as automatically isolated zones (Interior
Instant Zone) begin to flash and continue until the exit time is finished.
Method 2:
To arm the system in STAY mode press and hold [*] for 3 seconds.
When it beeps twice, release the button.
The STAY indicator flashes slow and exit time starts. After exit time, the STAY indicator is on.
Please contact your installer to enable/disable this function.
Forced Arming
Arming the system when a zone is not sealed is known as forced arming.
If the AWAY indicator is not on and a long beep sounds when you attempt to arm the system in
AWAY mode, then forced arming is not permitted. If this is the case, you will have to seal all
zones or manually isolate them before you can arm the system.
Please contact your installer to enable/disable this function.
Disarming the System
Disarming with Code
Enter your code and press [#] .It beeps twice and the AWAY or STAY indicator is extinguished.
Disarming with Key Switch
When the Key switch is deactivated, the system is disarmed and the AWAY or STAY indicator is
extinguished.
2.1.2
2.1.3
2.2
2.2.1
2.2.2
AMAX Arming and Disarming the System | en 11
Bosch Sicherheitsysteme GmbH User Guide 2014.01 | 02 | F.01U.295.569

Faults and Tamper Conditions
Whenever a system fault or tamper condition occurs, the FAULT or MAINS indicator flashes
and the keypad beeps.
Notice!
Operation is only possible in disarmed status.
System Fault or Tamper Analysis Mode
System Fault or Tamper Analysis Mode LED Keypad
To enter fault or tamper analysis mode for determining a system fault or tamper condition:
a) Enter your Code + [2] [1] and press [#]. It beeps twice. The FAULT indicator remains lit and
the STAY and AWAY indicators flash. The lit zone indicators indicate the type of fault or tamper
condition that occurred.
b) For a multi-level menu, enter the corresponding number to enter the submenu, press [ 0 ]
key to return to the main menu (see table next page).
c) To exit from Fault and Tamper Analysis Mode, press [#]. The STAY and AWAY indicators are
extinguished and the FAULT indicator remains lit, and the keypad stops the beep.
System Fault or Tamper Analysis Mode Text Keypad
To enter fault or tamper analysis mode for determining a system fault or tamper condition:
a) Enter your Code + [2] [1] and press [#]. It beeps twice.
b) Scroll down with [ arrow] to display all trouble or fault conditions.
c) To exit from Fault and Tamper Analysis Mode, press [#].
3
3.1
3.2
12 en | Faults and Tamper Conditions AMAX
2014.01 | 02 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH

Fault and tamper conditions
1 Accessory Module Failure
1
1 - 2 Network / IP Module 1 - 2 Failure
2
1 - 2 Output Expansion Module 1 - 2 Fault
3
1 - 6 Output Expansion Module 1 - 6 Fault
4
1Module DX4010 Missing
2Printer Missing
3Printer Fault
5
1 RF Receiver 1 Fault
2 RF Receiver 1 Missing
3RF Receiver 1 Jammed
6
1RF Sensor Missing *
2RF Sensor Fault *
7
1 - 8 RF Repeater 1-8 Missing
8
1Configuration Conflict Sensors *
2Configuration Conflict Repeaters *
3Configuration Conflict Keyfobs *
2
1
2
3
1 - 2 Panel Aux Power 1 - 2 Fault
4
1 - 2 Bosch Option Bus 1 - 2 Power Fault
5
1 - 8 RF Repeater 1-8 AC Power Fault
6
1 - 8 RF Repeater 1-8 Battery Fault
7
8
* One or more faults occur in this category will light this led.
Network / IP Module 1 Failure
Output Expansion Module Failure
RF Config Failure
RF Repeater Failure
RF Sensor Failure
RF Receiver Failure
Printer Failure
Input Expansion Module Failure
RF Repeater Battery Failure
RF Sensor Power Failure *
RF Keyfob Battery Failure *
Power Failure
Panel AC Failure
Panel Low Battery
Panel Aux Power Failure
Bosch Option Bus Power Failure
RF Repeater AC Power Failure
AMAX Faults and Tamper Conditions | en 13
Bosch Sicherheitsysteme GmbH User Guide 2014.01 | 02 | F.01U.295.569

3
1Onboard Output 1 Fault
2Onboard Output 2 Fault
4
5
1
6
1Communication Fault 1
2Communication Fault 2
3Communication Fault 3
4Communication Fault 4
5Phone Line Fault
7
Tamper
1
2
Keypad 1 – 16 Tamper
3
1 - 6 Zone Expansion Module 1 - 6 Tamper
4
Sensor Tamper DEOL
5
Zone type Tamper
6
1Keypad Lock out
7
1RF Receiver Tamper
8
1 - 8 RF Repeater Tamper
8
External Fault Zone 1-16
Keypad Failure
System Failure
Communication Failure
Keypad 1 – 16 Fault
Date Time not set
1 - 16
1 - 16
1 - 16
1 - 16
Output Failure
Keypad Tamper
System Tamper
1 - 16
External Failure
Zone Expansion Module Tamper
Zone Tamper DEOL
Zone type Tamper
Keypad Lock out
RF Receiver Tamper
RF Repeater Tamper
14 en | Faults and Tamper Conditions AMAX
2014.01 | 02 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH

System Test
Siren Test
This function allows the code holders to test the siren.
a) Enter your Code + [4] [1] and press [#]. It beeps twice and the siren will be activated for 1
second.
Communication Test
This function allows the code holders to send a test report to a central monitoring station.
a) Enter your Code + [4] [2] and press [#]. It beeps twice and a test report is send.
The Keypad will display the status of the test report for all communication paths.
To exit the test report press [#].
Walk Test Mode
This function allows code holders to test detection devices to ensure they are functioning
correctly. Before activating the Walk Test Mode, bypass any zones that are not required for
testing.
During the walk test, no walk test report is sent out to the control panel system.
How to enter into Walk Test Mode:
1. Enter your Code + [4] [3] and press [#]. It beeps twice and the STAY and AWAY indicators
flash.
2. Unseal and seal the zones to be tested. The keypad sounds one second beep and the
siren sounds one beep each time when a Zone status is changed.
To exit Walk Test Mode:
1. Enter your Code + [4] [3] and press [#].
4
4.1
4.2
4.3
AMAX System Test | en 15
Bosch Sicherheitsysteme GmbH User Guide 2014.01 | 02 | F.01U.295.569

Event Log Recall Mode
This function allows code holders to playback the last 254 events saved in each event log on
the Text Keypad.
All Event Log all events are logged
EN Event Log only mandatory EN 50131-3 events are logged
Dialer Event Log only mandatory EN 50136 events are logged
How to enter Event Log Recall modes:
All Event Log
Enter your code + [2] [2] and press[#]. It beeps twice.
EN Event Log
Enter your code + [2] [3] and press [#]. It beeps twice.
Dialer Event Log
Enter your code + [2] [4] and press [#]. It beeps twice.
Press [▲] or [▼] to move up and down in the Event Logs
Press [ #] To exit the Event Log
5
16 en | Event Log Recall Mode AMAX
2014.01 | 02 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH

Reset the Control Panel
This function allows code holders to reset all Alarms, Faults and Tamper conditions.
Enter your code + [6][#].
The keypad beeps twice and the signal is eliminated.
Notice!
You can reset alarms, faults or tamper conditions, only when they are not active anymore.
6
AMAX Reset the Control Panel | en 17
Bosch Sicherheitsysteme GmbH User Guide 2014.01 | 02 | F.01U.295.569

Bypassing
Bypassing Zones
By bypassing Zones, one or more zones are disabled for one arming cycle. After bypassing a
zone, you can arm the system even when a zone is in alarm state.
How to Bypass a Zone
a) Enter your code + [3] [1] and press [#]. The STAY indicator flashes fast.
b) Enter the zone number you wish to bypass, then press the [*] key.
(If you wish to bypass multiple zones, please repeat step b).
c) Press [#] to exit.
How to Unbypass a Zone
LED Keypad
a) Enter your code + [3] [1] and press [#] . The STAY indicator flashes fast.
b) Enter the zone number you wish to unbypass, then press the [*] key.
(If you wish to unbypass multiple zones, please repeat step b).
c) Press [#] to exit.
Text Keypad:
a) Enter your code + [3] [2] and press [#] . The STAY indicator flashes fast.
b) Enter the zone number you wish to unbypass, then press the [*] key.
(If you wish to unbypass multiple zones, please repeat step b)
d) Press [#] to exit.
Bypassing Faults and Tamper Conditions (Except Zone Tampers)
One or more faults and tamper conditions are disabled for one arming cycle. After bypassing a
Fault or Tamper condition, you can arm the system even when a Fault or Tamper condition
exists.
How to bypass a Fault or Tamper Condition
a) Enter your code + [3] [4] and press [#]. It beeps twice.
Bypass Inquire
The bypass inquires displays all bypassed zones.
a) Enter your code + [3] [3] and press [#]. It beeps twice.
b) Move up and down with [▲] or [▼] to display all bypassed zones.
c) Press [#] to exit.
7
7.1
18 en | Bypassing AMAX
2014.01 | 02 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH

Codes
Add/Change and Delete User Code
This function allows Master User to Add/change and delete User Codes.
How to Change the Code, User Code Priority and Area Assignment
LED Keypad:
a) Enter your User Code + [5] [4] and press [#].
It beeps twice and the STAY and AWAY indicators start flashing.
b) Enter the User Number (1-64) and press [#].
It beeps twice.
The corresponding Keypad indicator will light up for the current user permission level.
When AWAY and STAY indicators are flashing user permission level = 0.
c) Enter the user code priority (0-5) and press [#], there are no beeps to confirm the
operation.
00 = Master User
01 = Super User
02 = Basic User
03 = Arming User
04 = Duress User
05-15 = No Permission
Refer to Quick Keypad Operation Instructions, page 5
d) Enter the first value (00-71) for the area assignment for this user and press [#], there are
no beeps to confirm the operation.
The corresponding Keypad indicators will be on.
Enter the second value for the area assignment and press [#], there are no beeps to confirm
the operation.
The corresponding Keypad indicators will be on.
Please contact your installer for the right Values or check Table in Quick Reference Guide.
e) Enter the new user code (Default code length=4 digits / 5 or 6 digit code must be enabled
through the installer) for this user and press [#].
It beeps twice and the STAY and AWAY indicators stop flashing.
Text Keypad:
a) Enter your code and press [5] [4] [#].
It beeps twice and the STAY and AWAY indicators start flashing.
b) Enter the user number (1-64) and press [#].
c) Enter the user code priority (0-15) and press [#].
00 = Master User
01 = Super User
02 = Basic User
8
8.1
AMAX Codes | en 19
Bosch Sicherheitsysteme GmbH User Guide 2014.01 | 02 | F.01U.295.569

03 = Arming User
04 = Duress User
05-15 = No Permission
d) Enter the value (00-71) for the area assignment for this user and press [#].
Please contact your installer for the right Values or check Table in Quick Reference Guide.
e) Enter the new user code (Default code length=4 digits / 5 or 6 digit code must be enabled
through the installer) and press [#].
It beeps twice and the Keypad shows the next user.
f) Press long [-] to exit.
Notice!
This function is automatically terminated if you do not press a button within 240 seconds or if
you press [#]. One long beep indicates that the code already exists or that you entered an
incorrect user number.
Change Individual Code
This function allows user to change the individual code.
How to change the code
a) Enter your code + [5] [5] [#] and press.
It beeps twice and the STAY and AWAY indicators start flashing.
b) Enter the new code (Default code length=4 digits / 5or 6 digit code must be enabled
through the installer) and press [#].
It beeps twice and the STAY and AWAY indicators stop flashing.
8.2
20 en | Codes AMAX
2014.01 | 02 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH
Other manuals for AMAX 2100
6
This manual suits for next models
2
Table of contents
Other Bosch Keypad manuals

Bosch
Bosch RF3341 User manual

Bosch
Bosch DS7446KP User manual

Bosch
Bosch B942W User manual

Bosch
Bosch D1265 User manual

Bosch
Bosch D223A Series User manual

Bosch
Bosch Solution 2000 Instruction manual

Bosch
Bosch D626 User manual

Bosch
Bosch Security System User manual

Bosch
Bosch B942W User manual

Bosch
Bosch D621 Series User manual

Bosch
Bosch B921C User manual

Bosch
Bosch D1255/D1255B User manual

Bosch
Bosch AMAX 2100 User manual

Bosch
Bosch B920 User manual

Bosch
Bosch CK-M12 Instruction manual

Bosch
Bosch D220ATD User manual

Bosch
Bosch FMR-DACT-KEYPAD User manual

Bosch
Bosch B921C User manual

Bosch
Bosch D720 User manual

Bosch
Bosch D220A series User manual