manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bristan
  6. •
  7. Plumbing Product
  8. •
  9. Bristan QD SHXSMFF C D3 Wiring diagram

Bristan QD SHXSMFF C D3 Wiring diagram

Other Bristan Plumbing Product manuals

Bristan Quadrant Riser Rail kit User manual

Bristan

Bristan Quadrant Riser Rail kit User manual

Bristan VAL2 BRDSM C CD Wiring diagram

Bristan

Bristan VAL2 BRDSM C CD Wiring diagram

Bristan GLD2 BF C (D1) Wiring diagram

Bristan

Bristan GLD2 BF C (D1) Wiring diagram

Bristan QST BAS2 C User manual

Bristan

Bristan QST BAS2 C User manual

Bristan W BASIN06 C User manual

Bristan

Bristan W BASIN06 C User manual

Bristan VR1000 User manual

Bristan

Bristan VR1000 User manual

Bristan CART 06734B Original operating manual

Bristan

Bristan CART 06734B Original operating manual

Bristan Java J BF C User manual

Bristan

Bristan Java J BF C User manual

Bristan GLD2 BSM C Wiring diagram

Bristan

Bristan GLD2 BSM C Wiring diagram

Bristan VAL2 BAS C CD (D2) Wiring diagram

Bristan

Bristan VAL2 BAS C CD (D2) Wiring diagram

Bristan CAP2 SHUAR C Mounting instructions

Bristan

Bristan CAP2 SHUAR C Mounting instructions

Bristan ZI SHXSMCT Wiring diagram

Bristan

Bristan ZI SHXSMCT Wiring diagram

Bristan Joy ThermoSafe Series Mounting instructions

Bristan

Bristan Joy ThermoSafe Series Mounting instructions

Bristan Body Jet JET2 C User manual

Bristan

Bristan Body Jet JET2 C User manual

Bristan SQR KIT01 BLK D2 Wiring diagram

Bristan

Bristan SQR KIT01 BLK D2 Wiring diagram

Bristan N2 SHC3STP G Wiring diagram

Bristan

Bristan N2 SHC3STP G Wiring diagram

Bristan Options Bath User manual

Bristan

Bristan Options Bath User manual

Bristan IRBS4-CP Mounting instructions

Bristan

Bristan IRBS4-CP Mounting instructions

Bristan Vantage VTX 1/2 C User manual

Bristan

Bristan Vantage VTX 1/2 C User manual

Bristan Rio RO 1/2 C User manual

Bristan

Bristan Rio RO 1/2 C User manual

Bristan CAP2 SHXAR C (D6) Wiring diagram

Bristan

Bristan CAP2 SHXAR C (D6) Wiring diagram

Bristan BUZ2 SHXDIVCTFF C (D4) Wiring diagram

Bristan

Bristan BUZ2 SHXDIVCTFF C (D4) Wiring diagram

Bristan HOU SHC3DIV C Wiring diagram

Bristan

Bristan HOU SHC3DIV C Wiring diagram

Bristan N2 SHCDIV G (D7) Wiring diagram

Bristan

Bristan N2 SHCDIV G (D7) Wiring diagram

Popular Plumbing Product manuals by other brands

Weka 506.2020.00E ASSEMBLY, USER AND MAINTENANCE INSTRUCTIONS

Weka

Weka 506.2020.00E ASSEMBLY, USER AND MAINTENANCE INSTRUCTIONS

American Standard DetectLink 6072121 manual

American Standard

American Standard DetectLink 6072121 manual

Kohler K-6228 Installation and care guide

Kohler

Kohler K-6228 Installation and care guide

Uponor Contec TS Mounting instructions

Uponor

Uponor Contec TS Mounting instructions

Pfister Selia 49-SL Quick installation guide

Pfister

Pfister Selia 49-SL Quick installation guide

Fortis VITRINA 6068700 quick start guide

Fortis

Fortis VITRINA 6068700 quick start guide

Kohler K-12183 Homeowner's guide

Kohler

Kohler K-12183 Homeowner's guide

Maxxus MX-M206-01 instruction manual

Maxxus

Maxxus MX-M206-01 instruction manual

Viega Prevista Pure 8512 Instructions for use

Viega

Viega Prevista Pure 8512 Instructions for use

Kohler Centerset K-15240 Homeowner's guide

Kohler

Kohler Centerset K-15240 Homeowner's guide

Viega Prevista Dry 8522.33 Instructions for use

Viega

Viega Prevista Dry 8522.33 Instructions for use

Sanela Lema SLP 59RB Instructions for use

Sanela

Sanela Lema SLP 59RB Instructions for use

Elkay EDF15AC Installation, care & use manual

Elkay

Elkay EDF15AC Installation, care & use manual

Hans Grohe AXOR Citterio E 36702000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe AXOR Citterio E 36702000 Instructions for use/assembly instructions

baliv WT-140 manual

baliv

baliv WT-140 manual

Kohler Mira Eco Installation & user guide

Kohler

Kohler Mira Eco Installation & user guide

BELLOSTA romina 0308/CC Installation instruction

BELLOSTA

BELLOSTA romina 0308/CC Installation instruction

Crosswater Heir 18-31 installation instructions

Crosswater

Crosswater Heir 18-31 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Secure the shower to
the wall mount, ensuring
filters are in place.
2
5
Identify the
required position of
the valve and prepare
the water supply pipes.
Supply pipes should
be 150mm apart.
Using the backplate
supplied with the
wall mount, mark
and drill holes.
Secure the isolators
onto the backplates;
ensuring the olives
are positioned
over the pipework
correctly.
Secure the shrouds against
the rubber fixing plates.
4
3
1
Installation
Rotate the shroud until
the opening aligns with
the isolation screw.
Turn the screw to isolate
the water. Reverse the
process when turning
the water back on.
1
Isolation 2
Remove the concealing
cap from the shroud.
Secure the rubber and metal
backplates into place.
21mm21mm
REMEMBER
To service
your
product!
Operation
REMEMBER
hot on the left,
cold on the
right
IMPORTANT
Pack Contents
150mm
Centres
1.0
5.0
Pressure
BAR
0.2
4.0
2.0 3.0
Pressure
BAR
1.0
5.0
0.2
4.0
2.0 3.0 60°C
65°C
Specifications
Maximum Static Pressure: 10.0 bar
Inlet Water Temperature
15mm
Compression
Inlet Connections
Min: 0.2 bar Max: 5.0 bar
Working Pressures
The inlet hot water must
be at least 10°C above the
required blend temperature.
Factory pre-set
42°C
Inlet Dimensions
5°C
25°C
Cold Water Supply
Min: 5°C Max: 25°C
Hot Water Supply
Tools You’ll Need
Flat head
Screwdriver
Cross head
Screwdriver
Hexagonal Keys Socket SpannerPipe CutterPencil Drill Adjustable
Spanner
Installation Instructions
& User Guide
Please leave these instructions
with the end user
Product Code: QD SHXSMFF C (D3)
All products manufactured and supplied by Bristan are safe to use provided that
they are installed, operated and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999 and
current by-laws. For full Installation Requirements & Notes (IRN) please
visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of future
maintenance.
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder etc.
This product must not be modified in any way as this will invalidate the
guarantee.
Full access must be made available for future maintenance/servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires,
cables or water supply pipes. This can be checked with the aid of an
electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
If in doubt, contact a registered plumber or your Local Water Authority or
the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Prior to Installation
60-65°C Recommended
HotHot
ColdCold
OnOn
OO
x2
x2
x1
x1
x1
x1 x1
x1
x1
x1
150mm Centres
Remove the
temperature and
flow handles.
4
7
3
2
5Troubleshooting
To reduce the build up of
limescale and to ensure this
shower works to its maximum
performance we recommend
this shower is serviced every
6-12 months depending on the
hardness of your water.
To replace any spare parts for
your shower why not scan the
below QR Code and search
for your product.
Spare Parts
Servicing Intervals
Maintenance - Cartridge Cleaning
1
6
Symptom Cause Remedy
No flow or
low flow rate
partially closed isolation valve. Open isolation valve.
Instantaneous water heater cycles on and o
as flow rate or pressure is too low.
Increase water flow rate or
pressure through system.
Head of water is below the
minimum distance required.
2 meters minimum required.
Hot or cold water being drawn o elsewhere
causing pressure changes or instantaneous
boiler temperature changes.
Do not use other water outlets when using the taps.
Airlock or partial blockage in the supply
pipework.
Flush through pipework to ensure removal of debris and
any airlocks.
Water
dripping
from shower
This is normal for a short time after using the
shower.
This is caused by residual water tension, the build up of
water in the shower.
If water continues to drip,
possibly due to the cartridge
Remove cartridge and clean, refer to 'Maintenance' section
before starting any maintenance.
Shower does
not turn on
Closed isolation valve. Open isolation valve.
Mains water supply turned o. Turn on mains water supply.
At Bristan, we want to make things as easy as possible for our customers. That’s why we oer solid guarantees
on all our products, eective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team
of advisors will be able to oer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
Using the wall
mount, isolate
both shower
inlets before
carrying out any
maintenance.
4
2
1
Remove the
temperature
handle and
temperature stop.
Reverse the steps to
replace the temperature
stop and handle.
Turn the shower on and set
the temperature to the
maximum setting. Wait for
the temperature to stabilise.
Turn cartridge spindle clockwise
to decrease the temperature.
Turn cartridge spindle
anti-clockwise to increase
the temperature.
Temperature Setting
3
Remove all O-rings and seals,
check for damage and replace
if necessary.
Soak all other components in a
suitable solution until
fully de-scaled.
Rinse with clean water.
Use WRAS approved grease on
all seals before re-fitting.
Reverse the steps to
reinstall the valve,
cartridge and handles.
Check all joints
and connections
for any leaks.
Turn the water
supply to
the shower
back on.
Remove the cartridge
retaining nut and
cartridge.
Undo the screw underneath
the shower body to remove
the cartridge.
4
1
56
Riser Installation 23
Assemble
both the top
and bottom
brackets.
Attach the slider, hose
retainer, top and bottom
brackets to the riser rail.
Ensuring its straight, use the
assembled riser to mark the
appropriate positions for
the wall brackets.
Remove the brackets from
the riser. Mark and drill the holes
before securing them to the wall.
Re-attach
the riser to
the secured
brackets.
Connect the
hose to the
shower outlet
and handset,
feeding the
hose through
the hose
retainer.
Place the
handset in
the slider.
1
3
23
45
REMEMBER
To service
your
product!