Burkert 8030 HT User manual

Instruction Manual
© Bürkert 2003-2011 Subject to technical change without notice
00449752_ 1105/0_Original_FR

ENGLISH
ENGLISH
1.1 Utilisation ..................................................................................................................................................................................................4
1.2 Precautions at installation and commissioning .........................................................................................................5
1.3 Conformity to standards ..............................................................................................................................................................5
2.1 Design and Measuring principle............................................................................................................................................6
2.2 Ordering table of electronic modules SE30 HT .......................................................................................................7
2.3 Dimensions (mm) ..............................................................................................................................................................................7
4.1 General recommendations .....................................................................................................................................................12
4.2 Mounting on the pipe ..................................................................................................................................................................12

ENGLISH
ENGLISH
4.3 Electrical connection ...................................................................................................................................................................13
4.3.1 Connector EN 175301-803 (type 2508, supplied) ...........................................................................13
4.3.2 Wiring of the frequency output: pulse version (transistor outputs NPN and PNP)...14
4.3.3 Wiring of the frequency output: sinusoidal version (coil output) ..............................................15
5.1 Description of the label of the sensor SE30 HT ..................................................................................................16
5.2 Flow-velocity-DN diagrams ..................................................................................................................................................17
5.4 Wiring example .................................................................................................................................................................................19

ENGLISH
ENGLISH
The sensor 8030 HT has been designed to measure the flow rate of
neutral or slightly aggressive solid-free liquids.
There will be no manufacturer warranty for damages caused by
unexpected handling or wrong usage of the device. The warranty on the
device becomes invalid if any modification or change is made on the
device.

ENGLISH
ENGLISH
- Always ensure the materials in contact with the medium to measure are
chemically compatible with this medium.
- To clean the device, only use chemically compatible products.
- Always protect the device from electromagnetic perturbations,
ultraviolet radiations and, when installed outside, from the effects of
climatic conditions.
EMC: EN 50081-1, 61000-6-2
Security: EN 61010-1
Vibration: EN 60068-2-6
Shock: EN 60068-2-27

ENGLISH
ENGLISH
The flow sensor 8030 HT is built up with an electronic module SE30 HT
associated to a fitting S030 HT with integrated metallic paddle-wheel.
The sensor detects the rotation of the paddle-wheel which produces a
signal whose frequency f is proportional to the flow rate Q.
Two electronic module versions with frequency output are available:
- either with 2 pulse outputs (transistor NPN and PNP), where f = K.Q
- or with one sinusoidal output (coil), where f = 2 K.Q
where f = frequency in Hz
K = K factor specific to each fitting in pulses/l,
Q = flow rate in l/s
The electrical connection is carried out via an EN 175301-803
connector.
SE30 HT
S030 HT

ENGLISH
ENGLISH
32
40
66
44
54
9
EN 175301-803
12-36 VDC Pulse: 1 transistor NPN + 1 transistor PNP EN 175301-803 connector 449694
None Sinus: 1 coil EN 175301-803 connector 449693
6 95.5
8 95.5
15 100.5
20 98
25 98
32 102
40 105.5
50 112
H

ENGLISH
ENGLISH
Pipe diameter DN6 to DN50 (DN65 on request); determine the appropriate diameter using the flow-
velocity-DN diagrams (see Annex)
Medium temperature -15 °C up to 125 °C
Medium pressure PN40 if Tfluid < 90 °C
PN25 if 90 °C < Tfluid < 125 °C
Medium viscosity max. 300 cSt
Rate of solid particles max. 1%
Measuring range 0,5 m/s to 10 m/s
Accuracy ≤ ±1 % of the full scale*, with calibration on site (for example, using the teach-in feature of a
transmitter 8025, remote version)
≤ ± (1 % of the full scale* + 3% of the measured value), with standard K factor
Linearity ≤ ± 0.5 % of the full scale*
Repeatability 0.4% of the measured value
Measuring element metallic paddle-wheel of the stainless steel S030 HT fitting
* full scale = 10 m/s
Power supply none
Output data up to 500 Hz, about 2.8 mV peak-to-peak/Hz when loaded with 50 kΩ
(frequency = 2 x K factor x flow rate; for the value of the K factor, refer to the instruction
manual of the fitting)
Cable length max. 5 m, shielded

ENGLISH
ENGLISH
Power supply 12-36 VDC, filtered and regulated
Current consumption ≤ 10 mA (no load)
Protection against
polarity reversal yes
Output data transistor NPN and PNP, open collector, 700 mA max., NPN output: 0,2-30 VDC and
PNP output: supply voltage (see example in the Annex)
frequency: up to 250 Hz (frequency = K factor x flow rate; for the value of the K factor,
refer to the instruction manual of the fitting)
Protection against
short-circuits yes
Cable length max. 50 m, shielded (up to 500 m depending on the cable impedance and the current
consumption)
Pulse or sinus version EN 175301-803 connector (type 2508, supplied)
Type of cable recommended shielded, wire section between 0.14 and 0.5 mm2
Housing / Cable gland PPS, glass fiber reinforced / PA
Fitting S030HT, paddle-wheel stainless steel
Bearings of fitting S030HT Iglidur
Seal / axis of fitting S030HT FKM / ceramics
Ambient temperature - pulse version: -15 to +80° C
(operating and storage) - sinusoidal version: -15 to +100° C
Relative humidity <80%, non condensated
Protection rating (housing) IP 65, connector plugged-in and tightened

ENGLISH
ENGLISH
19
234567810
4
8
20
-4
-8
-12
-16
-20
1
v.
%
+
3
P.
E.
S.
/
F.
/
E.
v.
%
M./ o.R./V.M.
1
v.
%
P.
E.
S.
/
F.
/
E.
16
12
with calibration on site
without calibration on site, but standard K factor
Medium velocity
in m/s
max. error %
F.S = Full scale
o.R. = of Reading (measured value)
These values have been determined in the following reference conditions: medium = water, water and ambient
temperatures = 20 °C, min. straight upstream and downstream distances respected, appropriate pipe dimensions.
Accuracy of the measures with (teach-in feature of a transmitter 8025 for instance) and without
calibration on site
Measuring error - % of the measure

ENGLISH
ENGLISH

ENGLISH
ENGLISH
Always check the chemical compatibility of the materials the sensor is
made of with the products it may be in contact with.
For more information, please contact your Bürkert sales office.
The electronic module SE30 HT is associated to an S030 HT fitting for
installation on a pipe.
During mounting, follow the instructions given with the fitting S030 HT.
1
2
3

ENGLISH
ENGLISH
Always ensure the power supply is switched off before working on the
device. The connector must be plugged out.
Use:
- an earthed shielded cable with an operating temperature suited to the
process conditions
- a high quality voltage supply (filtered and regulated).
- Remove part [2] from part [4].
- Unscrew the cable gland [6].
- Insert cable into part [4] via cable gland and seal [5].
- Wire part [2] (see 4.3.2 or 4.3.3)
- Once wired, replace part [2] back into part [4].
- Tighten the cable gland [6].
- Place flat gasket [1] between the connector and the fixed
connector of the 8030HT.
- Connect the connector to the 8030HT.
- Tighten screw [3] to ensure tightness and correct electrical
contact.
1
3
4
5
6
2

ENGLISH
ENGLISH
PNP
0 V
V+ V+
IN
0 V
1
4
3
NPN
0 V
V+ V+
IN
0 V
1
2
3
Sensor Sensor
Receiver
Load
Receiver
Load
V+
(12-36 VDC)
NPN transistor output
0 VDC
Output
Output
PNP transistor output
1
32
4

ENGLISH
ENGLISH
3
2
Not connected
Coil output
Not connected
Coil output
Sensor Receiver
Coil Load
1
32
4

ENGLISH
ENGLISH
1. Type of the device
2. Power supply
3. Characteristics of the pulse output
4. Max. temperature of the medium
5. CE logo
6. Manufacturer code
7. Ordering number
8. Type of sinus output
FLOW:SE30/8030
COIL 12-36V DC
OPEN COLLECTOR PNP/NPN
FLUID : 160°C
449694 W46LG
Made in France
1
2
3
5
76
4
8

ENGLISH
ENGLISH
l/min
DN 65
DN 50 (DN65)*
DN 40 (DN50)*
DN 32 (DN40)*
DN 25 (DN32)*
DN 20 (DN25)*
DN 15 (DN20)*
5000
1000
100
3
2
1
20
10
0.5
5
0.3
0.2
500
50
0.01
0.02
0.05
0.1
0.2
0.5
1
2
5
10
20
50
100
200
m
3
/h
0.1 0.3 0.5 1 2 3 5 100.2 m/s
DN 08
DN 06
Flow rate
DN of the fitting
Medium velocity
* For following fittings:
- external threads acc. to SMS 1145
- weld end fittings acc. to SMS 3008, BS 4825 /
ASME BPE or DIN 1850 range 2
- Clamp acc. to SMS 3017 / ISO 2852, BS 4825 /
ASME BPE or DIN 32676

ENGLISH
ENGLISH
gpm
1000
500
200
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
30200.3 0.5 1 2 3 5 10
DN 65
100
50
fps
DN 08
DN 06
DN 50 (DN65)*
DN 40 (DN50)*
DN 32 (DN40)*
DN 25 (DN32)*
DN 20 (DN25)*
DN 15 (DN20)*
Flow rate
DN of the fitting
Medium velocity
* For following fittings:
- external threads acc. to SMS 1145
- weld end fittings acc. to SMS 3008, BS 4825 / ASME BPE
or DIN 1850 range 2
- Clamp acc. to SMS 3017 / ISO 2852, BS 4825 /
ASME BPE or DIN 32676

ENGLISH
ENGLISH
NPN (*)
PNP (*)
8030 HT
1
32
V+
0V
8030
4
NPN/PNP
SUPPLY
COIL
1
2
3
4
PE
NC
3A/230VAC
REL1
REL2
SENSOR SUPPLY
FLOW SENSOR
COIL NPN
PNP
FLOW SENSOR
SOURCE SINK
CURRENT
Iout L+ L-
Supply
13..30Vdc
PE PE PE
NC NC
+
-
PULSE INPUT
1
2
3
L+
+12V
+5V
P- P+
PULSE
OUTPUT
SENSOR
INPUT LOAD
1
2
3
39K
NPN
470 2.2K
COIL
PNP
8025 Universal

ENGLISH
ENGLISH
Other manuals for 8030 HT
1
Table of contents
Languages:
Other Burkert Accessories manuals

Burkert
Burkert FULLBORE S056 User manual

Burkert
Burkert 8007 User manual

Burkert
Burkert 8221 User manual

Burkert
Burkert S070 User manual

Burkert
Burkert MS06 Series User manual

Burkert
Burkert 8030 User manual

Burkert
Burkert 8020 User manual

Burkert
Burkert 8685 User manual

Burkert
Burkert S030 User manual

Burkert
Burkert FULLBORE S055 User manual

Burkert
Burkert 8220 User manual

Burkert
Burkert 8045 User manual

Burkert
Burkert 8170 User manual

Burkert
Burkert 2509 User manual

Burkert
Burkert GENERIC 8400 User manual

Burkert
Burkert MS05 User manual

Burkert
Burkert 8008 User manual

Burkert
Burkert 8223 User manual

Burkert
Burkert SE30 Ex Namur User manual

Burkert
Burkert 2510 User manual