4
1. FIRST USE
1.1. DELIVERY CONDITION
1A C.A 6550 or a C.A 6555 with a screen protection film and a rechargeable battery.
2Three crocodile clips (red, black, and blue).
3Two test probes (red and black).
4One power cord 2 metres long for recharging the battery.
5One data transfer software program and one optical-USB cord.
6One safety lead (blue), 0.5m long, with two high-voltage plugs, one of them with a rear pick-up.
7Two safety leads (red and blue), 3 metres long, with high-voltage plugs at both ends.
8One shielded safety lead (black), 3m long, with two high-voltage plugs, one of them with a rear pick-up.
9One carrying bag for the accessories.
10 One user manual on CD-ROM (one file per language).
11 One multilingual safety data sheet.
12 Specifications labels (one per language).
1.2. ACCESSORIES
Set of 3 shielded safety leads (black, red, and blue), 3 metres long, with a high-voltage plug at one end (with rear pick-up on
the black lead) and a large crocodile clip at the other
➀➃
➁➂➇
➈
11
12
➅
➄
➆
10
English
Safetydatasheet Measuring Instrument in CATII or CAT III or CAT IV (en)
Foryour safety and to avoiddamage to property:
Readwhat follows carefully and observe theseprecautions
Readthe other documents provided carefully,including any documents onthe CD-ROM
Meaningsof the principal symbols that may be present on your product:
CAUTION!Riskof Danger!
Referto this safety datasheet and comply
withthe precautions for use.
CAUTION!Riskof electric shock!
Refer to this safety datasheet, to the user
manualandcomply with the prec autionsforuse.
Current clamp: Can be applied to or
removed from non-insulated or bare
conductorsatdangerous volt ages.
Currentclamp: Do not apply to or remove from
conductorsatdangerous volt ages.
The CE marking indicates compliance
withthe European "Low Voltage", "EMC",
"WEEE",and "RoHS" directives.
In the European Union, this product is
subjectto selective collection in accordance
withthe European WEEE directive. Do not
disposeof it as ordinary waste; contact the
manufacturer for information about
collectionpoints.
Earth
Doubleinsulation
Do not dispose of the batteries as ordinary
waste;takethem to acollectionpoint.
Conditionsof use
Temperature,Humidity: Comply with the valuesstated in the user manual.
Altitude: 2 000 m
Pollutiondegree : 2
Precautionsfor use
Thesesafety instructions must be respected to assure the personal safety and the environmentof use. If
youdo not comply with them, there isa risk ofelectricshock, explosion or re.
Ifyou use these instruments other than as specied or without observingthe elementary safety rules, the
protectionthey provide may be compromised, endangeringyou.
Thesafety of any system which may include these leads or accessories is the responsibility of the
assemblerof the system.
Each time before use, always check that the insulation ofthe leads or accessories is in good
condition.Any element whose insulation is damaged (even partially) mustbe removed from use and
scrapped.A change of colorof the insulating material is an indication of deterioration.
Thesteady-state voltages,currents, and measurement categories are marked on the instruments, on
thecords, and on the accessories. Complywith these values.
Use specic individual safety protections when hazardous live parts can be accessible in the
installationwhere the measure is performed
Beforeusing your instrument, check that it is in good working order (for example, by measuring a
knowndangerous voltage).
Ifthe manual states how to replace the fuse(s) of yourinstrument, use only the recommended fuses.
Beforereplacing the batteries(rechargeable or not), disconnect the leads of your instrument.
The use of ameasurement instrument, a lead or an accessory with a lower
categoryor voltage downgrades the use of the assembly (instrument + lead +
accessory)to the lowest categoryand/or operating voltage.
Using a measuring instrument in a category II or III or IV environment can be dangerous. Insuch
measurement environments, the operators mustbe trained and/or accredited and/or informed of the
safetymeasures to be taken.
Measurementcategories:
CATII: Measurement category II is for measurements performed on circuits directly connected to the
lowvoltage installation
Examples:measurements on household appliancesand portable tools.
CATIII:Measurement category III is for measurement performedin the building installation
Examples:distribution boards, circuit-breakers, machine or industrial equipment with permanent
connectionto the xed installation.
CATIV:MeasurementcategoryIVis formeasurementsperformedatthesourceofthelow-voltageinstallation.
Example: meters and measurements on primary overcurrent protection devices and ripple
controlunits.
Cleaning
Disconnectthe leads or thetest accessories
Usea soft cloth, dampened with soapy water. Rinse with a damp cloth and dry rapidly with a dry
clothor forced air. Do not use alcohol,solvents, or hydrocarbons.
Donot modify the leads or accessories. Any non-compliant repairs can cause risks of electric shock
orburns.