CKD 4KA4 User manual

SM−215164-A/2
INSTRUCTION MANUAL
PNEUMATIC VALVE
4KA4, 4KB4
M4KA4, M4KB4
●Please read this instruction manual
carefully before using this product, par-
ticularly the section describing safety.
●Retain this instruction manual with the
product for further consultation whenever
necessary.
2ndEdition

[SM-215164-A/2] ―1
―
SAFETYPRECAUTIONS
WhendesigningandmanufacturingadeviceusingCKDproducts,themanufacturerisobli-
gatedtomanufactureasafeproductbyconfirmingsafetyofthesystemcomprisingthe
followingitems:
・Devicemechanism
・Pneumaticorwatercontrolcircuit
・Electriccontrolthatcontrolstheabove
Itisimportanttoselect,use,handle,andmaintaintheproductappropriatelytoensurethat
theCKDproductisusedsafely.
Observewarningsandprecautionstoensuredevicesafety.
Checkthatdevicesafetyisensured,andmanufactureasafedevice.
1.Thisproductisdesignedandmanufacturedasageneralindustrialmachinepart.Itmust
behandledbysomeonehavingsufficientknowledgeandexperience.
2.Usethisproductwithinitsspecifications.
This product cannot be used beyond its specifications. Additionally, the product must not be
modifiedormachined.
Thisproductisintendedforuseingeneralindustrialdevicesandparts.Usebeyondsuchconditions
is not considered. Consult with CKD for details when using the product beyond the unique
specificationrange,outdoors,orinthefollowingconditionsorenvironments.Inanycase,measures
forsafetyshallbeprovidedwhenthevavlemalfunctions.
①Useforspecialapplicationsrequiringsafetyincludingnuclearenergy,railroad,aviation,ship,vehicle,
medical equipment, equipment or applications coming into contact with beverage or food,
amusementequipment,emergencyshutoffcircuits,pressmachine,brakecircuits,orforsafeguard.
②Useforapplicationswherelifeorassetscouldbeadverselyaffected,andspecialsafetymeasures
arerequired.
3.Observecorporatestandardsandregulations,etc.,relatedtothesafetyofdevicedesign
andcontrol,etc.
ISO4414,JISB8370(pneumaticsystemrules)
JFPS2008(principlesforpneumaticcylinderselectionanduse)
Including High Pressure Gas Maintenance Law, Occupational Safety and Sanitation Laws, other
safetyrules,standardsandregulations,etc.
4.Donothandle,pipe,orremovedevicesbeforeconfirmingsafety.
①Inspectandservicethemachineanddevicesafterconfirmingsafetyoftheentiresystemrelatedto
thisproduct.
②Notethattheremaybehotorchargedsectionsevenafteroperationisstopped.
③Wheninspectingorservicingthedevice,turnofftheenergysource(airsupplyorwatersupply),and
turn off power to the facility. Release any compressed air from the system, and pay enough
attentiontopossiblewaterleakageandleakageofelectricity.
④When starting or restarting a machine or device that incorporates pneumatic components, make
surethatsystemsafety,suchaspop-outpreventionmeasures,issecured.
WARNING

[SM-215164-A/2]
−2−
5.Observewarningsandcautionsonthepagesbelowtopreventaccidents.
The safety cautions are ranked as "DANGER", "WARNING" and "CAUTION" in this
section.
FailuretopayattentiontoDANGERnoticesmaycauseasitu-
ation that results in a fatality or serious injury and that re-
quiresurgentaddressing
Failure to pay attention to WARNING notices may result in a
fatalityorseriousinjury.
FailuretopayattentiontoCATIONnoticesmayresultininjury
ordamagetoequipmentorfacilities.
Notethatsomeitemsdescribedas"CAUTION"mayleadto seriousresultsdependingon the
situation.Inanycase,importantinformationthatmustbeobservedisexplained.
Precautionswithregardtoguarantee
Guaranteeperiod
Theguaranteeperiodofourproductshallbeone(1)yearafteritisdeliveredtotheplacespecifiedbythe
customer.
Guaranteecoverage
IfanyfailureforwhichCKDCORPORATIONisrecognizedtoberesponsibleoccurswithintheabovewar-
rantyperiod,asubstituteornecessaryreplacementpartsshallbeprovidedfreeofcharge,ortheproduct
shallberepairedfreeofchargeattheplantofCKDCORPORATION.
However,theguaranteeexcludesfollowingcases:
①Defectsresultingfromoperationunderconditionsbeyondthosestatedinthecatalogueorspecifications.
②Failureresultingfrommalfunctionoftheequipmentand/ormachinemanufacturedbyothercompanies.
③Failureresultingfromwronguseoftheproduct.
④FailureresultingfrommodificationorrepairingthatCKDCORPORATIONisnotinvolvedin.
⑤Failureresultingfromcausesthatcouldnotbeforeseenbythetechnologyavailableatthetimeofdeliv-
ery.
⑥FailureresultingfromdisasterthatCKDisnotresponsibleof.
Guaranteestatedherecoversonlythedeliveredproducts.Anyotherdamageresultingfromfailureofthede-
liveredproductsisnotcoveredbythisguarantee.
Confirmationofproductcompatibility
Ourcustomershallberesponsibleofconfirmingcompatibilityofourproductusedinourcustomer’ssystem,
machineryordevice.
!
WARNING:
!
CAUTION:
!
DENGER :

[SM-215164-A/2] ―3
―
UNPACKING (Section 3)
Bags containing solenoid valves should be opened only
when you are ready to connect the valves to the pipes
immediatelyafterward.
Ifbagsareopenedbeforethevalvesarereadytobecon-
nectedtothepipes,theentryofforeignmatterfromthe
piping ports could cause the solenoid valves to fail or
malfunction.
INSTALLATION (Section 4)
Ifyouhavetousetheproductunderconditionsthatare
differentfromthespecifiedconditionsorifyouintendto
usetheproductforaspecialapplication,besuretocon-
sultusabouttheproductspecificationsbeforeusingthe
product.
ENVIRONMENT (Section 4.1)
a) Inadustyenvironment,foreignmattermayentereven
throughtheexhaustport.
Themovementoftheexhaustvalvecausesarespiratory
actionattheexhaustvalve,whichmaycauseinhalationof
foreignmatterneartheexhaustport. Thispotentialsit-
uation would be worse if the exhaust port is facing up-
ward. Attachasilencertotheexhaustportorhavethe
exhaustportfacedownward.
b) Keep the solenoid valve system dry. Take care to
avoiddirectcontactwithdrippingwaterorsplashesof
cuttingoil.
If the solenoid valve system is wet by a direct contact
withwaterorcuttingoil,anelectricalleakorburntsole-
noid coils may result. Protect the solenoid valve system
byusingacoverorbyinstallingitinsideapaneledcasing.
Ifthecylinderrodissplashedwithcuttingoil,theoilmay
penetrate through the cylinder into the secondary side
piping ofthe solenoid valve. This must be prevented to
avoidmalfunctions. Consultusforpreventivemeasures.
c) Thecoilswillproduceheat.
Particularly if the solenoid valve system is installed in a
controlboardorifthesolenoidcoilsneedtobeenergized
foralongtime,considerprovidingsufficientventilationto
releasetheheat. Thecoilscangetveryhot.
d) Do not use the solenoid valve system in an atmos-
pherethatincludesacorrosivegasorsolventvapors.
Do not use the solenoid valve system in an atmosphere
that includes a corrosive gas such as the sulfur dioxide
gasorinanatmospherethatincludessolventvapors.
e) Vibrationsandshocks
Do not subject the solenoid valve system to vibrations
50m/s2orstrongerorshocks300m/s2orstronger.
!
CAUTION:
!
CAUTION:
!
CAUTION:

[SM-215164-A/2]
−4−
f) Avoidusingthesolenoidvalvesysteminahumiden-
vironment because the humidity is likely to cause
condensationwithachangeinthetemperature.
g) Donotusethenormaltypesolenoidvalvesforanap-
plicationthatrequiresconformitywithexplosion-proof
specifications. Choose explosion-proof solenoid
valvesinstead.
h) Thepackingandgasketsmaydeterioratesoonerthan
usual if used in an atmosphere with a higher than
normaldensityofozone(forexample,theatmosphere
near a beach or in an area with frequent thunder-
storms).
Consultus forthepackingand gaskets to be usedinan
atmospherewithahigherozonedensity.
INSTALLATION (Section 4.2)
When installing a solenoid valve unit, never attempt to
holditinpositionbymeansofthepipesconnectedtoit.
Mountthesolenoidvalvebyapplyingthemountingscrews
and/ormountingplatetothesolenoidvalve.
!
WARNING:
!
CAUTION:

[SM-215164-A/2] ―5
―
PIPING (Section 4.3)
a) Observe the recommended tightening torque when
connectingpipes.
Observing the recommended tightening torque prevents
airleakageanddamagetothescrewthreads. Toprevent
damagetothescrewthreads,firstuseyourhandtolightly
tightenthescrewandthenuseatooltotightenthescrew
totherecommendedtorque.
b) Makesure thatthepipes willnotbedisconnected at
the joints by mechanical movements, vibrations or
tension.
If the exhaust piping of the pneumatic circuit is discon-
nected,theactuatorspeedcontrolisdisabled.
If the above happens to a chuck holding mechanism, the
chuck will open. The inadvertent opening of the chuck
maycauseaseriousaccident.
c) When supplying the compressed air for the first time
after completing the piping, be sure to check every
jointinthepipingforairleakage.
d) When supplying the compressed air for the first time
after completing the piping, increase the air pressure
graduallybutneverintroduceahighly-pressurizedair
suddenly.
A sudden introduction of a highly-pressurized air may
disconnectpipesatjointsand/orcausethetubestojump
around,anyofwhichmaycauseaninjury.
e) Donotdecreasetheinsidediameterofthepipingfrom
anyofthesolenoidvalveexhaustportstoadiameter
lessthantheexhaustpipeconnectingportsize.
Normal operation of the actuator depends on the
smoothnessoftheexhaustflow. Withamanifoldsystem,
arestrictiontotheexhaustflowmaypreventnormalop-
erationofothersolenoidvalves.
f) Removalofforeignmatter
Rust and other foreign matter in the pneumatic circuit
may cause a malf
unction or leakage fromthe valve seat.
Insert a filter (maximum allowable particle size 5μm or
less)immediatelyupstreamofthesolenoidvalve.
g) Airsupply
Donotrestricttheflowofairthroughtheairsupplypip-
ing. Withamanifoldsystemwithmultiplestations,adrop
in the air supply pressure may cause trouble through a
delayintheoperationtiming.
!
CAUTION:

[SM-215164-A/2]
−6−
WIRING (Section 4.4)
Before wiring, read the instruction manual carefully and
understandtheinstructions.
Apersonwhowiresneedstohaveknowledgeforsafely
performingsuchoperationbasedontheunderstanding
aboutthemechanismsandoperatingprinciplesofsolenoid
valves.
Before supplying the power, check the power supply
voltageandthecurrenttype(ACorDC).
MANUAL OPERATING DEVICE (Section 5.2)
a) Oncethemanualoperatingdevicehasbeenoperated,
alwaysreturnittoitsorigin(initialposition),andthen
starttheoperationofthedevice.
b) Beforeusingthemanualoverride,makesurethatno-
bodyispresentnearthecylindertobeactivated.
AIR QUALITY (Section 5.3)
a) Donotsupplyanythingotherthancompressedair.
b) Supply clean compressed air without any mixture of
corrosivegas.
a)
Compressed air usually contains a large amount of
drain, oxidized oil, tar, foreign matter, and rust from
thepiping. Filter out thoseelementsin thesupplied
air because they may cause a malfunction and de-
crease service life. In addition, clean the exhaust
beforeitisreleasedtotheairtominimizepollution.
b) Once you have lubricated a pre-lubricated valve, the
valveisnolongercapableofrunningwithoutbeinglu-
bricated from the outside. Do not leave the valve
withoutlubricationbutkeepitlubricated.
c) Donot use spindleoil or machine oil. Theymay in-
duceexpansionoftherubberparts,whichmaycause
amalfunction.
!
WARNING:
!
CAUTION:
!
WARNING:
!
WARNING:
!
CAUTION:

[SM-215164-A/2] ―7
―
ELECTRIC CIRCUITS (Section 5.4)
a) Check forthe presenceof anycurrentleak fromthe
external control device because it may cause an er-
roneousvalveoperation.
When a programmable controller or a similar controlde-
vice is used, a current leak may prevent the normal re-
turningofthevalvewhenthesolenoidisde-energized.
b) Restrictiononcurrentleak
When controlling solenoid valves using a programmable
controlleror asimilar controldevice, makesure thatthe
current leak in the programmable controller output is
equal to or les
sthan the level shown in the table below.
A current leak larger than the allowable level may cause
anerroneousvalveoperation.
PERIODIC INSPECTION (Section 6.1)
Before providing a maintenance service, cut the power
and the supply of compressed air and confirm the ab-
senceofresidualpressure.
Theaboveisrequiredtoensuresafety.
Regularly perform the daily and periodic inspections to
correctlymaintainproductperformance.
If the productis not correctly maintained , product per-
formance may deteriorate dramatically, resulting in a
shorter service life, fractures of components, and mal-
functions.
DISASSEMBLING AND REASSEMBLING (Section 6.2)
Before disassembling and reassembling solenoid valves,
readtheinstructionmanualcarefullyandunderstandthe
instructions.
A person who disassembles and reassembles a solenoid
valve system needs to have a knowledge for safely per-
formingsuchoperationbasedontheunderstandingabout
the mechanisms and operating principles of solenoid
valves.
Personnel involved in this step must have passed the
PneumaticPressureSkillTestClass2orhigher.
!
CAUTION:
AC100V 3.0mAorlower
AC200V 1.5mAorlower
DC24V 1.8mAorlower
CRcircuit
Leakage
current
Solenoidvalve
Contact
C
R
Programmable
controller
!
CAUTION:
!
WARNING:
!
WARNING:

−8−
INDEX
4KA4, 4KB4
M4KA4, M4KB4
Manual No. SM-215164-A/2
1. PART NAME AND DESCRIPTION 9
2. INTERNATIONAL SYSTEM OF UNITS (SI) 10
3. UNPACKING 11
4. INSTALLATION
4.1 Environment 12
4.2 Installation 13
4.3 Piping 14
4.4 Wiring 18
5. OPERATING RECOMMENDATION
5.1 Function 23
5.2 Manual Operating Device 25
5.3 Air Quality 26
5.4 Electric Circuits 28
6. MAINTENANCE
6.1 Periodic Inspection 29
6.2 Disassembling and Reassembling 30
7. TROUBLE SHOOTING 34
8. PRODUCT SPECIFICATIONS AND HOW TO ORDER
8.1 Product Specifications 35
8.2 How to Order 39
8.3 Consumable parts 47

[SM-215164-A/2] ―9
―
PARTNAME
ANDDESCRIPTION
1
. PARTNAMEANDDESCRIPTION
Direct piping unit Direct piping manifold
Subplate piping unit Subplate piping manifold
No. Part Name explanation
①Valve unit There are direct pipng and sub plate piping
Manual operating device It uses in case of manual operation. There are a non lock and a lock
formula
③Wire connection It connections to the electric circuit
④Sub plate It is a block for the piping
⑤Piping Port Port P is the supply port ; port R is the exhaust port ; port A and B is
the Output port
⑥Mounting screw
There are two every i
ndividual valve and it fixes the
valve unit on the Various base.

[SM-215164-A/2]
−10−
SI
2
2. INTERNATIONALSYSTEMOFUNITS(SI)
In this manual, values are expressed using the International System of Units
(SI).
Use the table below to convert them into values expressed in conventional
units.
Table of conversion between SI units and conventional units
(The values printed in Bolds fonts are values given in the International System of Units (SI)):
Force
N dyn kgf
1 1×1051.01972×10-1
1×10-5 1 1.01972×10-6
9.80665 9.80665×1051
Stress
Pa or N/m2MPa or N/mm2kgf/mm2kgf/cm2
1 1×10-6 1.01972×10-7 1.01972×10-5
1×1061 1.01972×10-1 1.01972×10
9.80665×1069.80665 1 1×102
9.80665×1049.80665×10-2 1×10-2 1
Note:1Pa=1N/m2, 1MPa=1N/mm2
Pressure
Pa kPa MPa bar kgf/cm2atm mmH2O mmHg or Torr
1 1×10-3 1×10-6 1×10-5 1.01972×10-5 9.86923×10-6 1.01972×10-1 7.50062×10-3
1×1031 1×10-3 1×10-2 1.01972×10-2 9.86923×10-3 1.01972×1027.50062
1×1061×1031 1×10 1.01972×10 9.86923 1.01972×1057.50062×103
1×1051×1021×10-1 1 1.01972 9.86923×10-1 1.01972×1047.50062×102
9.80665×1049.80665×10 9.80665×10-2 9.80665×10-1 1 9.67841×10-1 1×1047.35559×102
1.01325×1051.01325×1021.01325×10-1 1.01325 1.01323 1 1.03323×1047.60000×102
9.80665 9.80665×10-3 9.80665×10-6 9.80665×10-5 1×10-4 9.67841×10-5 1 7.35559×10-2
1.33322×1021.33322×10-1 1.33322×10-4 1.33322×10-3 1.35951×10-3 1.31579×10-3 1.35951×10 1
Note:1Pa=1N/m2
Example (converting a pressure value):
1kgf/cm2→0.0980665MPa 1MPa →1.01972×10kgf/cm2

[SM-215164-A/2] ―11
―
UNPACKING
3
3. UNPACKING
Bags containing solenoid valves should be opened only
when you are ready to connect the valves to the pipes
immediatelyafterward.
Ifbagsareopenedbeforethevalvesarereadytobecon-
nectedtothepipes,theentryofforeignmatterfromthe
piping ports could cause the solenoid valves to fail or
malfunction.
a) Check the model number imprinted on the product to make sure that the
product you received is exactly the product you ordered.
b) Check the exterior of the product for any damage.
c) Before using the product, read the supplied documentation.
!
CAUTION:

[SM-215164-A/2]
−12−
INSTALLATION
4
4. INSTALLATION
Ifyouhavetousetheproductunderconditionsthatare
differentfromthespecifiedconditionsorifyouintendto
usetheproductforaspecialapplication,besuretocon-
sultusabouttheproductspecificationsbeforeusingthe
product.
4.1 Environment
a) Inadustyenvironment,foreignmattermayentereven
throughtheexhaustport.
Themovementoftheexhaustvalvecausesarespiratory
actionattheexhaustvalve,whichmaycauseinhalationof
foreignmatterneartheexhaustport. Thispotentialsit-
uation would be worse if the exhaust port is facing up-
ward. Attachasilencertotheexhaustportorhavethe
exhaustportfacedownward.
b) Keep the solenoid valve system dry. Take care to
avoiddirectcontactwithdrippingwaterorsplashesof
cuttingoil.
If the solenoid valve system is wet by a direct contact
withwaterorcuttingoil,anelectricalleakorburntsole-
noid coils may result. Protect the solenoid valve system
byusingacoverorbyinstallingitinsideapaneledcasing.
Ifthecylinderrodissplashedwithcuttingoil,theoilmay
penetrate through the cylinder into the secondary side
piping of the solenoid valve. This must be prevented to
avoidmalfunctions. Consultusforpreventivemeasures.
c) Thecoilswillproduceheat.
Particularly if the solenoid valve system is installed in a
controlboardorifthesolenoidcoilsneedtobeenergized
foralongtime,considerprovidingsufficientventilationto
releasetheheat. Thecoilscangetveryhot.
d) Do not use the solenoid valve system in an atmos-
pherethatincludesacorrosivegasorsolventvapors.
Do not use the solenoid valve system in an atmosphere
that includes a corrosive gas such as the sulfur dioxide
gasorinanatmospherethatincludessolventvapors.
e) Vibrationsandshocks
Do not subject the solenoid valve system to vibrations
50m/s2orstrongerorshocks300m/s2orstronger.
f) Avoidusingthesolenoidvalvesysteminahumiden-
vironment because the humidity is likely to cause
condensationwithachangeinthetemperature.
!
CAUTION:
!
CAUTION:

[SM-215164-A/2] ―13―
INSTALL
A
TION
4
g) Donotusethenormaltypesolenoidvalvesforanap-
plicationthatrequiresconformitywithexplosion-proof
specifications. Choose explosion-proof solenoid
valvesinstead.
h) Thepackingandgasketsmaydeterioratesoonerthan
usual if used in an atmosphere with a higher than
normaldensityofozone(forexample,theatmosphere
near a beach or in an area with frequent thunder-
storms).
Consult us forthe packing and gaskets to be used inan
atmospherewithahigherozonedensity.
4.2 Installation
When installing a solenoid valve unit, never attempt to
holditinpositionbymeansofthepipesconnectedtoit.
Mountthesolenoidvalvebyapplyingthemountingscrews
and/ormountingplatetothesolenoidvalve.
4.2.1 A work space for installation, removal, wiring, and piping opera-
tions should be provided around the installed solenoid valve sys-
tem.
4.2.2 Direct mounting
1) Direct piping Type
Use three or four through holes
unit manifold
2) Sub plate piping Type
Use three or four mounting holes
unit manifold
!
WARNING:
!
CAUTION:
3-5.3
mounting holes 4-9
mounting holes
29
3-φ4.5
mounting hole
58(10Y:38)
38
4-6.6
mounting holes

[SM-215164-A/2]
−14−
INSTALLATION
4
4.3 Piping
a) Observe the recommended tightening torque when
connectingpipes.
Observing the recommended tightening torque prevents
airleakageanddamagetothescrewthreads. Toprevent
damagetothescrewthreads,firstuseyourhandtolightly
tightenthescrewandthenuseatooltotightenthescrew
totherecommendedtorque.
b) Make sure that the pipes will not be disconnected at
the joints by mechanical movements, vibrations or
tension.
If the exhaust piping of the pneumatic circuit is discon-
nected,theactuatorspeedcontrolisdisabled.
If the above happens to a chuck holding mechanism, the
chuck will open. The inadvertent opening of the chuck
maycauseaseriousaccident.
c) When supplying the compressed air for the first time
after completing the piping, be sure to check every
jointinthepipingforairleakage.
d) When supplying the compressed air for the first time
after completing the piping, increase the air pressure
gradually but never introducea highly-pressurized air
suddenly.
A sudden introduction of a highly-pressurized air may
disconnectpipesatjointsand/orcausethetubestojump
around,anyofwhichmaycauseaninjury.
e) Donotdecreasetheinsidediameterofthepipingfrom
anyofthesolenoidvalveexhaustportstoadiameter
lessthantheexhaustpipeconnectingportsize.
Normal operation of the actuator depends on the
smoothnessoftheexhaustflow. Withamanifoldsystem,
arestrictiontotheexhaustflowmaypreventnormalop-
erationofothersolenoidvalves.
f) Removalofforeignmatter
Rust and other foreign matter in the pneumatic circuit
may cause a malfunction or leakage from the valve seat.
Insert a filter (maximum allowable particle size 5μm or
less)immediatelyupstreamofthesolenoidvalve.
g) Airsupply
Donotrestricttheflowofairthroughtheairsupplypip-
ing. Withamanifoldsystemwithmultiplestations,adrop
in the air supply pressure may cause trouble through a
delayintheoperationtiming
Approproate torque
Joint screw Approproate torque N・m
Rc3/8 13〜15
Rc1/2 16〜18
!
CAUTION:

[SM-215164-A/2] ―15―
INSTALL
A
TION
4
4.3.1 Sealant
Refrain applying sealant or seal tape approx.two pitches of thread from the
tip of pipe to avoid some of the sealing substances from falling into piping
system.
When winding the fluororesin seal tape on the screw part, wind the seal tape two
or three times where one or two screw threads remain at the top end of the screw,
and then push the tape by tip of the nail to make the tape tightly in contact with
the screw. When using the liquid sealant, apply a proper amount of sealant
where one or two screw threads remain at the top end of the screw.
At this time, do not apply the sealant to the female screw parts of the machine.
4.3.2 Flushing
Before connecting pipes, flush the interiors of the tubes, solenoid valves, and
connected devices to remove foreign matter.
4.3.3 Blow circuit
Do not open the cylinder port circuit to the air because a drop in the air sup-
ply pressure may cause a malfunction. Select the external pilot type design
instead of the internal pilot type design.
4.3.4 Exhaust port
Minimize the restriction to the flow of the exhaust air because such re-
striction may cause a delay in the cylinder response. If such a delay hap-
pens, the speed needs to be adjusted between the cylinder and solenoid valve.
(Right) (False) (Right) (False)
●SealTape ●Sealant(Pasteorliquid)

[SM-215164-A/2]
−16−
INSTALLATION
4
4.3.5 Pipe connections
(1) Tubes to be used
For use with solenoid valves with one-touch joints, select tubes of the type
specified by us:
Soft nylon tubes (F-1500 Series)
Urethane tubes (U-9500 Series)
New urethane (NU Series)
(2) For installation at a site that has spatters in the air, select incombustible
tubes or metal pipes.
(3) For a piping used for both hydraulic and pneumatic controls, select a hydrau-
lic hose.
When combining a spiral tube with a standard one-touch joint, fix the tube
origin using a hose band. Otherwise the rotation of the tube will decrease
the efficiency of the clamping.
For use in a high-temperature atmosphere, select fastener joints instead of
one-touch joints.
(4) When selecting from tubes commercially available, carefully study the accu-
racy of the outside diameter as well as the wall thickness and the hardness.
The hardness of an urethane tube should be 93°C or more (as measured by
a rubber hardness meter).
With a tube that does not have a sufficient accuracy of the outside diameter
or the specified hardness, a decrease in the chucking force may cause dis-
connection or difficulty in inserting.
Tube dimensions
Outside diameter
mm
Inside diameter mm
Soft nylon Urethane New ure-
thance
φ10 φ7.2 φ6.5 φ7.5
φ12 φ8.9 φ8 φ9
(5) Minimum bending radius of tubes
Observe the minimum bending radius of tubes. Neglecting the minimum
bending radius may cause disconnection or leaks.
Tube bore
Minimum bending radius mm
Soft nylon Urethane New ure-
thance
φ10 40 40 30
φ12 55 50 36
(6) Cutting a tube
To cut a tube, use a tube cutter to cut the tube perpendicularly to the length
of the tube. Inserting an obliquely cut end of a tube may cause air leakage.
Outside diameter allowance
Soft nylon φ10, φ12 ±0.1mm
Urethane φ10, φ12 +0.1mm
-0.2mm
New urethance φ10, φ12 +0.1mm
-0.15mm

[SM-215164-A/2] ―17―
INSTALL
A
TION
4
(7) Tube connections
Do not bend a tube immediately at where it is connected to the joint but lead
it out straight from the end of the joint for a length equal to or greater than
the outside diameter of the tube. The tension applied sideways through the
tube should not exceed 40N.
(8) Blank plug to be used
For use with a solenoid valve with a one-touch joint, select the blank plug
specified by us: Blank plug GWP□-B Series

[SM-215164-A/2]
−18−
INSTALLATION
4
4.3.6 External pilot (K) piping port
Pilot air is individual supply in the external pilot (K) type. Supply port is Rc1/8, so pay atten-
tion to piping connecting position not to mistake. If it isn’t correctly piped, it causes the mal-
function.
unit
4.4 Wiring
Anelectricalshockhazardexistsduringwiring,ordisas-
sembly or reassembly of the DIN terminal box. Turn
OFFthepowercompletelybeforestartingsuchwork.
Before supplying the power, check the power supply
voltageandthecurrenttype(ACorDC).
!
WARNING:
!
CAUTION:
External pilot Supply port
Rc1/8

[SM-215164-A/2] ―19―
INSTALL
A
TION
4
1) Caution for wiring
(1) When using the small terminal box and water-proof is required, use cab-tire
cords φ4.5 to φ7 in outer diameter (water-resistance is improved, but not
for outdoor use).
(2) The connector type (C, C1, C2, C3, D, D1, D2, D3) should be used in a place
with little dust and not directly exposed to water and oil.
(3) For the electrical circuit, use a switching circuit free of chattering.
(4) The electrical circuit should have fuses.
(5) Be sure that the operation voltage is within 10% of the rated voltage.
2) Wire connection
Name Grommet (standard) Small terminal box Small terminal box
with indicator light
Small terminal box
with surge suppressor
and indicator light
Option
code No code B L LS
ape
Circuit
Name Plug-in connector C type
with lead wire
Plug-in connector C type
without lead wire
Plug-in connector C type
with lead wire, surge
suppressor and indicator
light
Plug-in connector C type
without leadwire,
surge suppressor and
indicator light
Option
code C C1 C2 C3
Shape
Circuit
(
〜
)
(
〜
)
AC
(
〜
)
(
〜
)
AC
(
)
(
)
DC
Red
Black
(
〜
)
(
〜
)
AC
(
)
(
)
DC
( )
( )
DC
This manual suits for next models
3
Table of contents
Other CKD Control Unit manuals

CKD
CKD QEV2 User manual

CKD
CKD GCVE2 Series User manual

CKD
CKD PV5G Series User manual

CKD
CKD FWD Series User manual

CKD
CKD SNP Series User manual

CKD
CKD CVE2 Series Installation and operating manual

CKD
CKD 3GD/E1 Series User manual

CKD
CKD MN3GD/E1 Series User manual

CKD
CKD SAB A Series User manual

CKD
CKD GHV Series User manual
Popular Control Unit manuals by other brands

Harvia
Harvia Griffin Combi CG170C instructions

National Instruments
National Instruments PXIe-6591R user manual

Omron
Omron SYSMAC LINK C1000H-SLK21-V1 System manual

Robur
Robur Remote control Eco Installation and use manual

UNI
UNI EV Series Operating and mounting manual

mercor
mercor mcr 0204 User instruction manual