Instruction Sheet Template - V1.3 –Updated 20/01/2022
Clevertest Plus
Refer to the supplementary operation guide supplied with the Product.
After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red
flashing for a period up to 2 minutes.
For products with a Dome (-D), the Dome may require removal to successfully scan the fitting with a
camera using the CleverSparky App.
Maintained fittings (LLIFEM-PRO-SM-vv-xx-yy-zz-ww) cannot be scanned with a camera using the
CleverSparky App as the maintained light source interferes with the camera scanning function. To
register the fitting manually enter the serial number from the QR code and visually read the test result
and enter manually into CleverSparky.
Zoneworks HIVE Monitored Options
Fittings with part numbers -HV/-HVG are fitted with Zoneworks communications modules (nodes). These
fittings are monitored using RF transceiver modules operating in the ISM band connected to a central
Server (can also be connected via Ethernet/Internet/Fibre). Zoneworks software on the server is used to
monitor, coordinate testing and collate test data from each fitting. Zoneworks Fittings can be
commissioned by scanning the supplied barcode. The LED Test Switch indicator provides a multifunction
indication of the status of the fitting during testing and normal operation:
Option
State
LED Operation
HV, HVG,
Commissioned
LED on Solid (Green)
HV, HVG
Un-commissioned
With network connectivity
Batt plugged-in: yellow 1s, green 1s
Batt unplugged: red 1s, off 1s
HV, HVG
Un-commissioned
Without network connectivity
Batt plugged-in: yellow 250mS,
green 250mS, yellow 250mS, green
250mS, green 1s
Batt unplugged: red 250mS, off
250mS, red 250mS,off 250mS, off 1s
HV, HVG
Emergency Light Test In Progress
LED flashes at yellow 1s , 0ff 1s
For further information of installation of a Zoneworks system, please refer to the Zoneworks Users Guide
and Commissioning Guide
DALI EM Option
Luminaires with part numbers having -DALI are fitted with DALI modules (nodes)that facilitate connection
and integration to 3rd Party Lighting Control Systems. Before installing the -DALI luminaire, please confirm
that the Lighting Control System has the capability to monitor DALI Emergency Luminaires. The -DALI
fitting will be addressed and configured into the control system by the Lighting Control System
Commissioning Technicians and not Clevertronics.
State
LED Operation
Commissioned/ Un-commissioned
LED on Solid (Green)
Emergency Light Test in progress
LED flashes at 1s On (Yellow) & 1s Off
“IDENTIFY COMMAND”
Lamp and Status LED Flash for 30 seconds
A 2-way “figure 8” cable and terminal block facilitates the connection to the DALI network. DALI
connections are marked as Da Da.
L10TM LIFELIGHT PRO Surface Mount Emergency
Luminaire
Installation & Maintenance Instruction Leaflet
Victoria (Head Office & Manufacturing)
Website: www.clevertronics.com.au
Email: info@clevertronics.com.au
Phone: +61 3 9559 2700
Fax: +61 3 9559 2799
New South Wales
Phone: +61 2 8805 6400
Fax: +61 2 8805 6444
Queensland
Phone: +61 7 3442 9700
Fax: +61 7 3442 9777
South Australia/Northern Territory
Phone: +61 8 8301 8800
Fax: +61 8 8351 8286
Western Australia
Phone: +61 8 9207 0000
Fax: +61 8 9207 0088
New Zealand
Phone: +64 800 548 448
Designed in Australia to comply with the requirements
of AS2293.3: 2019 and AS/NZS CISPR15: 2017
NOTE: Standard product codes with this symbol are
enabled with Clevertest Plus capability. Please refer to the
operation guide supplied with the product for details.
Models:
LLIFEx-PRO-SM-vv-xx-yy-zz-ww
Testing:
Options:
Manual Test
xx = Blank
Dome
z=D
Zoneworks HIVE
xx = HV/HVG
Tamperproof
yy=TP
DALI Registered.
xx = DALI
Colour, Black
ww=BLK
Non-Maintained
x=Blank
Maintained
x=M
Switched Active
vv=SA
Spare Parts:
1530231
Replacement Battery
8003081
Replacement Emergency LED Board
8003501
Replacement Emergency Driver
Important:
It is illegal for anyone, exceptfor a licensed electrician toinstall or maintain this product. Before installation,
ensure that the electricity supply has been switched off and isolated. Installation must be carried out in
accordance with the relevant Australian and International Standards.
1942264
V1.0
29 March 2022
Instruction Sheet Template - V1.3 –Updated 20/01/2022
Installation:
The LLIFE-PRO-SM is a Surface Mount (SM) fitting that can be attached directly to any solid surface (use
appropriate fixings to suit the mounting surface). Please follow the steps below to install the LLIFE- PRO-
SM:
•Remove the Lid from the Base by using a flat screwdriver to release the snap fits (see below)
•Cut/Drill out Cable Entry points (see image below)
•Drill out the required fixing holes on the Base (see image below)
•Mark holes on mounting surface (use drilled out holes on the Base as a template)
•Mount Base using appropriate fixings to ensure a secure installation (pre-drill holes if required)
•Insert Mains Cables through Cable Entry
•Terminate the Mains Cables into terminal block. Ensure Active, L & Neutral, N wires are connected
as per Terminal Block Label.
•Re-attach Lid Assembly, ensuring to align Mains Connector Pins into Terminal Block
•If the CTP capabilities are activated, please affix the CTP status label to a visible surface and Four
Segment Marking on the product will include an ‘’F’’ in third segment block.
Networking:
When installing the product on a monitored network, (HIVE, DALI) simply insert the relevant Smart Node
PCA.
Dimensions:
Lid Removal:
Testing:
Once connected to the 240V mains supply, the unit must be allowed to charge the battery for at least 24
hours. Conduct the following tests:
•For the first test, the emergency lamp must remain illuminated for at least 2 hours after
disconnection from the mains supply.
•Subsequent tests require the unit to illuminate for at least 90 minutes. The results of all tests are
required to be recorded in a service logbook, which is to be kept on-site at all times. If the unit fails
to remain illuminated for the requisite time, remedial action must be taken to repair the situation
and once completed, the unit must pass a subsequent test. For more specific information, please
refer to the current edition of the AS 2293.3 Standard.
Trouble Shooting:
Below are a list of common problems and their possible causes.
Fault: The Green LED Test Switch indicator is not illuminated.
Check: A.C. is connected and is turned on.
Battery is connected
Test Switch for damage.
Fault: Lamp does not illuminate in emergency mode.
Check: A.C. is connected.
Lamp is correctly inserted.
Battery is connected
Fault: Lamp illuminates in emergency mode, but only stays on for a short period.
Check: Battery has been allowed to charge for at least 24 hours.
Battery for damage.
Rated Emergency Lumen Output in accordance with AS2293.1, not applicable
for –TH (theatre) version (refer to spacing tables for installation positions):
Refer to the Technical Label for classification information.
Caution:
On many building sites, power circuits may be cut off in an uncontrolled and repetitive basis during
construction. As a result, any Exit & Emergency Units, on these circuits, will have their batteries
discharged or “cycled”. The battery in this fitting has been selected to give excellent long-life
performance in a controlled AS2293 testing environment. Excessive battery cycling will reduce through-
life performance and may lead to premature battery failure. Battery warranty claims, as a result of such
abuse, are specifically EXCLUDED from Clevertronics warranty terms.
Warranty:
For Product Warranty information and Terms and Conditions of Sales please refer to our website
http://clevertronics.com.au/terms-conditions-sale-australia-nz/

Other Clevertronics Lantern manuals

Clevertronics Supalite L10 LWFLED Series Technical specifications

Clevertronics

Clevertronics Supalite L10 LWFLED Series Technical specifications

Clevertronics L10 LWP2LIFE-PRO-WPPOD Series Installation and operating instructions

Clevertronics

Clevertronics L10 LWP2LIFE-PRO-WPPOD Series Installation and operating instructions

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMC Series Installation and operating instructions

Clevertronics

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMC Series Installation and operating instructions

Clevertronics CLP LIFELIGHT CLIFE Series Maintenance and service guide

Clevertronics

Clevertronics CLP LIFELIGHT CLIFE Series Maintenance and service guide

Clevertronics L10 LWFLED Maintenance and service guide

Clevertronics

Clevertronics L10 LWFLED Maintenance and service guide

Clevertronics L10 LIFELIGHT PRO Manual

Clevertronics

Clevertronics L10 LIFELIGHT PRO Manual

Clevertronics Argonaut PRO ARGOPRO-1200 Series Installation and operating instructions

Clevertronics

Clevertronics Argonaut PRO ARGOPRO-1200 Series Installation and operating instructions

Clevertronics L10 Supalite LWFLED Series Instruction Manual

Clevertronics

Clevertronics L10 Supalite LWFLED Series Instruction Manual

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMC Series Installation and operating instructions

Clevertronics

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMC Series Installation and operating instructions

Clevertronics LP CBS2N Series Technical specifications

Clevertronics

Clevertronics LP CBS2N Series Technical specifications

Clevertronics LP Supalite CFLLED Series Installation and operating instructions

Clevertronics

Clevertronics LP Supalite CFLLED Series Installation and operating instructions

Clevertronics LP Supalite CFLLED Series Installation and operating instructions

Clevertronics

Clevertronics LP Supalite CFLLED Series Installation and operating instructions

Clevertronics ARGO-1500-EM Series Installation and operating instructions

Clevertronics

Clevertronics ARGO-1500-EM Series Installation and operating instructions

Clevertronics ARGO-600 EM Series Installation and operating instructions

Clevertronics

Clevertronics ARGO-600 EM Series Installation and operating instructions

Clevertronics Argonaut Square ARGOSQ Series Installation and operating instructions

Clevertronics

Clevertronics Argonaut Square ARGOSQ Series Installation and operating instructions

Popular Lantern manuals by other brands

Eaton Corelite Series installation instructions

Eaton

Eaton Corelite Series installation instructions

unios Evio EVIO0907 manual

unios

unios Evio EVIO0907 manual

Project Source FEW1691A-7 quick start guide

Project Source

Project Source FEW1691A-7 quick start guide

BEGA 24 816 Instructions for use

BEGA

BEGA 24 816 Instructions for use

Acuity Brands Lighting RUBIK 9CS installation instructions

Acuity Brands Lighting

Acuity Brands Lighting RUBIK 9CS installation instructions

Gama Sonic 105BP250040 instruction manual

Gama Sonic

Gama Sonic 105BP250040 instruction manual

Anslut 004581 operating instructions

Anslut

Anslut 004581 operating instructions

Vaughan Mottisfont CL0130 installation guide

Vaughan

Vaughan Mottisfont CL0130 installation guide

LIVARNO home 398633 2107 Instructions for use

LIVARNO home

LIVARNO home 398633 2107 Instructions for use

Philips LifeLight user manual

Philips

Philips LifeLight user manual

LiRON LiGHTING LEDPPST quick start guide

LiRON LiGHTING

LiRON LiGHTING LEDPPST quick start guide

Emos ZM5121 manual

Emos

Emos ZM5121 manual

InoTec LED J-SV Operating	 instruction

InoTec

InoTec LED J-SV Operating instruction

esotec Modena Using instructions

esotec

esotec Modena Using instructions

Coleman 5335 Series user manual

Coleman

Coleman 5335 Series user manual

Avlite AV-426-ICAO Installation and service manual

Avlite

Avlite AV-426-ICAO Installation and service manual

Nimbus Water Systems WINGLET CL Welcome guide

Nimbus Water Systems

Nimbus Water Systems WINGLET CL Welcome guide

Saxby Lighting Reeve 2 instruction manual

Saxby Lighting

Saxby Lighting Reeve 2 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.