Refer to the supplementary operation guide supplied with the Product.
After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red
flashing for a period up to 2 minutes.
Zoneworks and DATA Monitored Options
Supalites with part numbers –ZW and -DATA are fitted with Zoneworks communications modules
(nodes).These fittings are monitored using either Powerline Carrier Technology that utilising the power
cable to provide data communication or a dedicated data cable to/from data routers installed on a
dedicated data trunk connected to a central Server (can also be connected via Ethernet/Internet/Fibre).
Zoneworks software on the server is used to monitor, coordinate testing and collate test data from each
fitting. Zoneworks Supalites can be commissioned by a single push of the test switch, or scanning of the
supplied barcode. The LED Test Switch indicator provides a multifunction indication of the status of the
Supalite during testing and normal operation:
State
LED Operation
Commissioned
LED on Solid (GREEN)
Un-commissioned
LED flashes at 0.5Hz (0.5s GREEN, 0.5s Yellow)
Emergency Light Test In Progress
LED flashes at 3s On (Yellow) & 0.5s Off
In the case of the DATA version a 2-way “figure 8” cable and terminal block facilitates the connection to
the DATA network via a multi-drop bus (daisy chain connection). For further information of installation of
a Zoneworks system, please refer to the Zoneworks Users Guide and Commissioning Guide (incl. DATA
version)
DALI EM Option
Supalites with part numbers -DALI are fitted with DALI modules (nodes) that facilitate connection and
integration to 3rd Party Lighting Control Systems. Before installing the -DALI Supalite, please confirm that
the Lighting Control System has the capability to monitor DALI Emergency Luminaires. The Supalite will
be addressed and configured into the control system by the Lighting Control System Commissioning
Technicians and not Clevertronics.
State
LED Operation
Commissioned/ Un-commissioned
LED on Solid (GREEN)
Emergency Light Test in progress
LED flashes at 1s On (Yellow) & 1s Off
“IDENTIFY COMMAND”
Fitting goes into emergency mode for 10 seconds
A 2-way “figure 8” cable and terminal block facilitates the connection to the DALI network OR a 5/6way
“structured wiring system” lead and plug facilitates the power and DALI connection. DALI connections
are marked as Da Da.
L10 Supalite LED Weatherproof Emergency
Luminaire
Installation & Maintenance Instruction Leaflet
Victoria (Head Office & Manufacturing)
195 Chesterville Rd
Moorabbin VIC 3189
Phone: +61 3 9559 2700
Fax: +61 3 9559 2799
New South Wales
Phone: +61 2 8805 6400
Fax: +61 2 8805 6444
Queensland
Phone: +61 7 3442 9700
Fax: +61 7 3442 9777
South Australia/Northern Territory
Phone: +61 8 8301 8800
Fax: +61 8 8351 8286
Western Australia
Phone: +61 8 9248 3720
Fax: +61 8 9248 3725
New Zealand
Phone: +64 800 548 448
Designed in Australia to comply with the requirements of
AS2293.3: 2005 and AS/NZS CISPR15: 2011
NOTE: Standard product codes with this symbol are
enabled with Clevertest Plus capability. Please refer to the
operation guide supplied with the product for details.
Models:
LWFLED-xx
Testing :
Manual Test
xx = Blank
Zoneworks
xx = ZW
Z/W DATA
xx = DATA
DALI Comp.
xx = DALI
Clevertest
xx = CT
(NOTE: -CTProductssupplied with the Clevertest Plus Symbol are activated with Clevertest
PLUS capability. Please refer to the operation guide supplied with the product for details).
Spare Parts:
1530260
BATT:L10 6.6V 2500mAh.200mm lead.SBS.
8002625
PCA:LEDPP MV.Drvr.18V 500mA. CT10220-L2
1100550
WP Led Head, c/w Led's & Loom, Gland
Important:
It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before installation,
ensure that the electricity supply has been switched off and isolated. Installation must be carried out in
accordance with the relevant Australian and International Standards.
1949321
V1.2
21 November 2018
Installation:
The L10 Weatherproof Supalite (LWFLED) is Wall Mounted. The LWFLED is housed in a weatherproof
enclosure. The enclosure base is attached to the wall using screws installed through the 4 isolated holes.
Once the base is mounted and wired the gear tray and cover are installed. Please follow the steps below
to install the Weather Proof Exit:
•Remove the enclosure cover.
•Remove the gear tray.
•Determine power entry.
•Drill power access hole in the box base.
•Position the box base in the mounting position.
•Mark the 4 holes for mounting. Install the base using appropriate fixings (not supplied).
•Connect the 240VAC supply to the terminal block on the Gear Tray.
•Reinstall the gear tray.
•Reinstall the enclosure cover.
•If the CTP capabilities are activated please affix the CTP status Label to a visible surface.
Networking:
When installing the product on a monitored network, (ZONEWORKS, DATA, DALI) simply insert the
relevant Smart Node PCA.
Mounting Hole Dimensions:
Testing:
When the Supalite unit is connected to the un-switched active, it must be allowed to charge the battery
for at least 24 hours. The emergency lamp only illuminates during a power fail. Conduct the following
tests:
•The emergency lamps must illuminate for at least 2 hours after disconnection from the mains. The
results of all tests are required to be recorded in a service logbook, which is to be kept on-site at all
times. If the unit fails to illuminate for the requisite time, remedial action must be taken to repair the
situation and once completed, the unit must pass a subsequent test.
•Press and hold Test Button or switch Off Mains Supply, check that the emergency lamps are On.
•Release the Test Button or Switch On Mains Supply, check that the emergency lamps are Off
(Non-maintained operation).
Below are a list of common problems and their possible causes:
Fault: The Green LED indicator is not illuminated.
Check: A.C. is connected and is turned on.
Battery is connected.
Test Switch for damage.
Fault: Lamp does not illuminate in emergency mode.
Check: A.C. is connected.
Lamp is correctly inserted.
Battery is connected
Fault: Lamp illuminates in emergency mode, but only stays on for a short period.
Check: Battery has been allowed to charge for at least 24 hours.
Battery for damage.
Rated Emergency Lumen Output in accordance with AS2293.1 (refer
to spacing tables for installation positions):
N/A –Refer to the IES file when doing computer aided design or request spacing guidance from
Clevertronics.
Caution:
On many building sites, power circuits may be cut off in an uncontrolled and repetitive basis during
construction. As a result, any Exit & Emergency Units, on these circuits, will have their batteries
discharged or “cycled”. The battery in this fitting has been selected to give excellent long life
performance in a controlled AS2293 testing environment. Excessive battery cycling will reduce through-
life performance and may lead to premature battery failure. Battery warranty claims, as a result of such
abuse, are specifically EXCLUDED from Clevertronics warranty terms.
Warranty:
For Product Warranty information and Terms and Conditions of Sales please refer to our website
http://clevertronics.com.au/terms-conditions-sale-australia-nz/

Other Clevertronics Lantern manuals

Clevertronics LP CBS2N Series Technical specifications

Clevertronics

Clevertronics LP CBS2N Series Technical specifications

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMC Series Installation and operating instructions

Clevertronics

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMC Series Installation and operating instructions

Clevertronics Argonaut Square ARGOSQ Series Installation and operating instructions

Clevertronics

Clevertronics Argonaut Square ARGOSQ Series Installation and operating instructions

Clevertronics L10 LIFELIGHT PRO Manual

Clevertronics

Clevertronics L10 LIFELIGHT PRO Manual

Clevertronics L10 Supalite LWFLED Series Instruction Manual

Clevertronics

Clevertronics L10 Supalite LWFLED Series Instruction Manual

Clevertronics ARGO-1500-EM Series Installation and operating instructions

Clevertronics

Clevertronics ARGO-1500-EM Series Installation and operating instructions

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMC Series Installation and operating instructions

Clevertronics

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMC Series Installation and operating instructions

Clevertronics L10 LWP2LIFE-PRO-WPPOD Series Installation and operating instructions

Clevertronics

Clevertronics L10 LWP2LIFE-PRO-WPPOD Series Installation and operating instructions

Clevertronics CLP LIFELIGHT CLIFE Series Maintenance and service guide

Clevertronics

Clevertronics CLP LIFELIGHT CLIFE Series Maintenance and service guide

Clevertronics L10 LWFLED Maintenance and service guide

Clevertronics

Clevertronics L10 LWFLED Maintenance and service guide

Clevertronics LP Supalite CFLLED Series Installation and operating instructions

Clevertronics

Clevertronics LP Supalite CFLLED Series Installation and operating instructions

Clevertronics LP Supalite CFLLED Series Installation and operating instructions

Clevertronics

Clevertronics LP Supalite CFLLED Series Installation and operating instructions

Clevertronics L10 LIFELIGHT PRO-SM Series User manual

Clevertronics

Clevertronics L10 LIFELIGHT PRO-SM Series User manual

Clevertronics ARGO-600 EM Series Installation and operating instructions

Clevertronics

Clevertronics ARGO-600 EM Series Installation and operating instructions

Clevertronics Argonaut PRO ARGOPRO-1200 Series Installation and operating instructions

Clevertronics

Clevertronics Argonaut PRO ARGOPRO-1200 Series Installation and operating instructions

Popular Lantern manuals by other brands

Zumtobel 2LIGHT MINI E1 Series Instructions for use

Zumtobel

Zumtobel 2LIGHT MINI E1 Series Instructions for use

Heitronic 500047 Installation and operating instructions

Heitronic

Heitronic 500047 Installation and operating instructions

BEGA 33 059 Instructions for use

BEGA

BEGA 33 059 Instructions for use

Quoizel ELB9009MB installation guide

Quoizel

Quoizel ELB9009MB installation guide

MOOD SALON Installation and operating instructions

MOOD

MOOD SALON Installation and operating instructions

Restoration Hardware RIBBON quick start guide

Restoration Hardware

Restoration Hardware RIBBON quick start guide

Logik LLIGHTS14 instruction manual

Logik

Logik LLIGHTS14 instruction manual

esotec Cube operating instructions

esotec

esotec Cube operating instructions

MELINERA 317141 Instructions for use

MELINERA

MELINERA 317141 Instructions for use

BEGA 50 103 Instructions for use

BEGA

BEGA 50 103 Instructions for use

Ultraframe Classiclantern FABRICATION GUIDE

Ultraframe

Ultraframe Classiclantern FABRICATION GUIDE

GOAL ZERO Lighthouse 400 user guide

GOAL ZERO

GOAL ZERO Lighthouse 400 user guide

Sunna Design Sol EVERGEN M Series user manual

Sunna Design

Sunna Design Sol EVERGEN M Series user manual

Brinkmann Camping lantern owner's manual

Brinkmann

Brinkmann Camping lantern owner's manual

EASY LED SALOA L15 installation guide

EASY LED

EASY LED SALOA L15 installation guide

NEO TOOLS 99-087 Translation of the original instructions

NEO TOOLS

NEO TOOLS 99-087 Translation of the original instructions

Jaykal JLS68103-G60-ACTR installation instructions

Jaykal

Jaykal JLS68103-G60-ACTR installation instructions

Intermatic Malibu LZ6 instructions

Intermatic

Intermatic Malibu LZ6 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.