“ (Medium)” setting may need to be selected.
Water tooHOT Increase water flow by adjusting knob“E” clockwise.
“ (Medium)” setting may need to be selected.
Increase pressure to water supply e.g. fully open service valve or stopcock.
Check hose is not kinkedrestricting the water flow and clean handset.
Water tooCOLD Check power is on by LED indicator beingilluminated.
Decrease water flow by adjusting knob “E” anti-clockwise.
“(High)” settingmay need to be selected.
Select inner or outer only handset spray pattern.
Spray pattern poor Clean the shower handset.
Water takes longer
to heat up Thermal cut-out has operated after previoususe and the LED indicatorhas gone out
(automatically resets when unit cools down).
“(High)” settingmay need to be selected.
Water goes cold
while using
shower
Check LED indicator is illuminated.
Check water pressure has not fallen sofar as to let pressure switch cut out,
e.g. Another tap drawingwater off.
Raise position of shower handset.
Broken parts Please contact our spares department on 0870 9000 420 (UK only).
Water continues to
flow when button
“D” pressed to stop
This is normal.
The shower includes a shutdown feature that means the water will continue to flow
for up to7 secondsafter “ (stop)” has been selected.
PROFESSIONAL SERVICE
If the previous “Self Help” checks fail to restore the performance, you should seek professional help.
The person who installedthe shower is probably the best one to investigate and correct it andis certainly the
person to contact if you have had a problem in the guarantee period.
The following additional checklist is provided forthe benefit of the qualified service person.
WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR
BEFORE REMOVING THE COVER TO MAKE CHECKS
Water tooHOT Water flow restrictedby blockage in filterof solenoid valve. Replace solenoid valve.
Water tooCOLD Check circuit through thermal cut-out and/or through pressure switch microswitches.
A schematic wiring diagram is available fromour technical advisory service.
Check each element circuit and check tightness of electrical connections.
No control over
water flow Check control knob is correctly engaged onto the stabiliser valve drive gear.
Undo headworks of stabiliser valve.
Check stabiliser is inplace and remove any debrisin valve then re-assemble.
Water discharges
from pressure
relief valve
Check for cause of high pressure and remove it.
Blockage on outlet e.g. blocked shower handset.
Replace the pressure relief disc (not coveredby guarantee).
Water does not
flow when button
“A B C” is pressed.
Ensure that the flying lead from the PCB is connected to the FrontCover.
Check circuit through solenoid coil and/or through pressure switch microswitches.
Possible PCB fault.If defective then replace. Power supply not reaching shower.
WHAT TO DO IF THINGS GO WRONG (1)