DANLERS CESRA PIR DSIP Quick start guide

Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products
Please call for more information or a free catalogue, or visit our website.
This product conforms to BS EN 60669-2-1 and BS EN 55015.
Please ensure the most recent edition of the appropriate local wiring regulations are observed
and suitable protection is provided e.g. a 10 amp circuit breaker and voltage surge protection.
Please ensure that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Precautions and Warranty
PIR occupancy switch with DSI dimming
CESRA PIR DSIP
DANLERS passive infra-red occupancy (absence detection) switches
with closed loop control (CESRA PIR DSIP) can be used to control high
frequency DSI dimmable ballasts.
These PIR switches incorporate a passive infra-red quad sensor to detect
movement of a warm body within their detection zone (diagram A) and a
photocell to monitor the ambient light level.
CESRA PIR DSIP can be mounted directly onto solid ceilings or onto
a range of different mounting boxes
Functions
When entering a zone of detection a momentary wall switch must be pressed
to send a signal to the PIR to switch the lights ON at maximum and start
the closed loop control to maintain the preset lux level value (LUX) between
30 and 1000 lux (default value 1000 lux). See diagram C.
NO BACKGROUND ILLUMINANCE RUN ON TIME SET: If no further
movement is detected the lights will switch OFF after the set PIR hold timer
(TIME) has expired. This time lag can be set via the TIME adjuster to 10
seconds, 20s, 40s, 80s, 2m30s, 5m, 10m, 20m or 40 minutes (default value
10 seconds). See diagram B. Alternatively, the momentary switch can be
pressed for more than 2 seconds to switch the lights OFF.
BACKGROUND ILLUMINANCE RUN ON TIME SET:If no further movement
is detected the lights will FADE to minimum after the set PIR hold timer
(TIME) has expired OR if the momentary wall switch is pressed for more
than 2 seconds. The lights will then stay at minimum until the background
hold timer (RUN ON) has expired. The RUN ON time can be set via the
RUN ON adjuster to 0, 1, 2, 5, 10, 15, 20, 30 minutes or innite (default
value is 0). See diagram C.
If the momentary wall switch is pressed for less than 2 seconds while
the background hold timer is counting down, the lights will switch ON at
maximum and start the closed loop control to maintain the set lux level value.
Loading
These PIR switches can switch up to:
6 amps (1500W) of dimmable uorescent lamps.
2 amps (500W) of CFL, LED Drivers and LED lamps and ttings.
CESRA PIR DSIP
has an integral
DSI Power Supply Unit suitable for
use with up to 12 DSI ballasts, assuming each ballast has a constant
current output of 1mA.
17/08/16 INS267 CESRA PIR DSIP
Variants
CEFL PIR DSIP: PIR occupancy switch (presence detection) with DSI
daylight linked dimming (does not require a momentary (retractive wall
switch).
Troubleshooting
The load will not switch on:
• The moving body is not emitting more IR than the background.
(Person wearing insulating clothing in a warm environment)
• Person is too far from the PIR switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing).
Installation procedure
1. Please read these notes carefully before commencing work.
In case of doubt please consult a qualied electrician.
2. POSITIONING: The CESRA PIR DSIP should be installed to achieve
correct coverage of the area, see diagram A.
Avoid locating this product
where it is exposed to drafty conditions (exposed lobbies, open ceiling
voids or near fans) or near heat sources.
3. Make sure the power is isolated from the circuit.
The PIR should be connected as shown in diagram D:
SL Switched Line out
L Live in
N Neutral in
DA - DSI control line (Polarity independant)
DA + DSI control line (Polarity independant)
SW1Switch input
5. Knockout or drill the appropriate holes on the mounting plate for attaching
the plate to the ceiling or back box (if applicable). Feed cables through
the appropriate (side or rear) entry hole (see diagram E). Screw the back
mounting plate to the ceiling or back box via the mounting holes. Wire the
cables into the sensor head block terminal. Push the sensor head onto the
mounting plate and align the side clips with the slots on the sensor heads.
Start-up mode
When the PIR is powered up, it will switch on the load for 1 minute, the load
will then switch off and the PIR will enter its Operating Mode.
Time / Run-on / Lux set up
The LUX adjuster spindle on the side of the PIR is used to regulate the automatic
daylight linked dimming function lux level (see diagram C opposite). This should
be adjusted in situ by rotating the LUX adjuster slowly anticlockwise (+ to -)
so that the desired level of brightness is achieved under the luminarie(s) being
controlled.
Once the correct level is achieved and there has been no further adjustment to
the LUX spindle,
CESR PIR DSIP
will go through a 30 second delay before the
automatic closed loop control will start.
CESR PIR DSIP incorporates a xed 20 second fade rate from maximum to
the set back level.
Sensitivity
CESR PIR DSIP incorporates a sensitivity adjuster, labelled ‘SENS’, to reduce
the range of detection from 100% to 50% in 9 steps
(see diagram B opposite).
L
N
DSI
Ballast
CEFLA PIR DSIP
DSI Control Lines
DSI
Ballast
Optional
other load
230 VAC
SL
L
N
Mains
rated
retractive
wall switch
or rocker
wall switch
(toggled)
SW1
CESRA PIR DSIP
up to 5m
up to 7m
Strong detection zone
i.e. person moving arm
or walking towards PIR
Secondary detection zone
i.e. person walking
perpendicular to PIR
For optimum coverage
recommended mounting
height: 2.4 to 5m
D: Wiring diagram, CESRA PIR DSIP controlling several DSI dimmable ballasts
RUN ON
minmax
LUX
minmax
Typical settings
INFINITE
30m
20m
15m
10m
5m
0s
1m
2m
C: Adjusting LUX and RUN-ON
TIME
minmax
SENS
minmax
Typical settings
40m
20m
10m
5m
2.5m
80s
10s
20s
40s
50%
100%
B: Adjusting SENSITIVITY and TIME
A: Detection diagram
Knock out mounting
holes or pre-drill
pilot holes.
For cable entry
from above -
knock out central
mounting hole
For side entry -
knock out side
mounting hole
from mounting
plate and device
Connect wires to
terminal block on
the device
Join device to
mounting plate via
mounting clips
E: Mounting plate xing

Other DANLERS Switch manuals

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS BMEXPIR Quick start guide

DANLERS

DANLERS BMEXPIR Quick start guide

DANLERS EZ CESR Quick start guide

DANLERS

DANLERS EZ CESR Quick start guide

DANLERS WAPIR Quick start guide

DANLERS

DANLERS WAPIR Quick start guide

DANLERS TLSW 10 ILM Quick start guide

DANLERS

DANLERS TLSW 10 ILM Quick start guide

DANLERS CZ HB ND Quick start guide

DANLERS

DANLERS CZ HB ND Quick start guide

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS CESF PIR IP66 Quick start guide

DANLERS

DANLERS CESF PIR IP66 Quick start guide

DANLERS CZ CEFL Quick start guide

DANLERS

DANLERS CZ CEFL Quick start guide

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS WACE RFS Quick start guide

DANLERS

DANLERS WACE RFS Quick start guide

DANLERS BMPIR10M Quick start guide

DANLERS

DANLERS BMPIR10M Quick start guide

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS CESRAPIRSD Quick start guide

DANLERS

DANLERS CESRAPIRSD Quick start guide

DANLERS CESPLL10VDC Quick start guide

DANLERS

DANLERS CESPLL10VDC Quick start guide

DANLERS TLSW A20 Quick start guide

DANLERS

DANLERS TLSW A20 Quick start guide

DANLERS COPIR IP66 User manual

DANLERS

DANLERS COPIR IP66 User manual

DANLERS DUSW Quick start guide

DANLERS

DANLERS DUSW Quick start guide

DANLERS CESF PIR Quick start guide

DANLERS

DANLERS CESF PIR Quick start guide

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS CESFPIRSV Quick start guide

DANLERS

DANLERS CESFPIRSV Quick start guide

Popular Switch manuals by other brands

Dymec DY-H8080XR user manual

Dymec

Dymec DY-H8080XR user manual

MikroTik CCR1009-7G-1C-PC quick start guide

MikroTik

MikroTik CCR1009-7G-1C-PC quick start guide

Longshine LCS-GS9420-A user manual

Longshine

Longshine LCS-GS9420-A user manual

MRV Communications OptiSwitch-100 Installation and user guide

MRV Communications

MRV Communications OptiSwitch-100 Installation and user guide

ATEN CS52D user guide

ATEN

ATEN CS52D user guide

H3C S6800-2C-FC Installation, quick start

H3C

H3C S6800-2C-FC Installation, quick start

Impact Acoustics 3-Play user manual

Impact Acoustics

Impact Acoustics 3-Play user manual

Ekinex EK-TM1-TP user manual

Ekinex

Ekinex EK-TM1-TP user manual

Dell PowerEdge 180AS Cable Routing guide

Dell

Dell PowerEdge 180AS Cable Routing guide

Belkin OmniView F1DP104Aea user manual

Belkin

Belkin OmniView F1DP104Aea user manual

Wise P980 Series manual

Wise

Wise P980 Series manual

Cisco NMD-36-ESW= Product support bulletin

Cisco

Cisco NMD-36-ESW= Product support bulletin

roco Z21 switch DECODER manual

roco

roco Z21 switch DECODER manual

3Com 3CRWX120695A Command reference

3Com

3Com 3CRWX120695A Command reference

EVA Logik WF31 quick start guide

EVA Logik

EVA Logik WF31 quick start guide

Digitus DN-95140 user manual

Digitus

Digitus DN-95140 user manual

Vetus MPE1KB user manual

Vetus

Vetus MPE1KB user manual

Milltronics LevelGenie instruction manual

Milltronics

Milltronics LevelGenie instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.