Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products
Please call for more information or a free catalogue, or visit our website.
This product conforms to BS EN 60669-2-1, BS EN 55015 and BS EN 60730.
Please ensure the most recent edition of the appropriate local wiring regulations are observed
and suitable protection is provided (protected with the appropriate MCB) 1kV over voltage.
Please ensure that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Precautions and Warranty
08/09/16 INS009 CZ CEFL DALI
Variants
DANLERS design and manufacture other ControlZAPP CZCEFL variants, coded by
the following order codes:
CZ CEFL Suitable for mains switching
CZ CEFL VF Suitable for mains switching, Volt Free contacts
CZ CEFL10VDC Suitable for 1-10VDC ballasts
CZ CEFL10VDC VF Suitable for 1-10VDC ballasts, Volt Free contacts
CZ CEFL DALI VF Suitable for DALI ballasts, Volt Free contacts
Troubleshooting
The load will not switch on:
•TheLUXsettingasspeciedbytheControlZAPPAppissettoolowandis
inhibiting the switch.
• The moving body is not emitting more IR than the background.
(Person wearing insulating clothing in a warm environment)
• Person is too far from the PIR switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing).
• The control unit battery is not engaged (ON).
Switch RED dip switch next to the telejack connector on the control
unit to the DOWN position.
The load switches on when nobody is present:
• Heater causing infra-red variations in a small cold room.
Resite the CZ CEFL DALI control away from heater.
• Please contact DANLERS for further technical support.
 ControlZAPPCeilingushmountedswitches
CZ CEFL DALI
ControlZAPPceilingushpassiveinfra-redswitches(PIR)canbeushmounted
into suspended and plasterboard ceilings (diagram A).
These PIR switches incorporate a passive infra-red quad sensor to detect
movement of a warm body within their detection zone (diagram B) and a photocell
to monitor the ambient light level.
ALLadjustmentsaremadeviaafreelydownloadableControlZAPPApp
availablefromtheDANLERSwebsite.
If CZ CEFL DALI is set as PIR with LUX input, upon detecting movement, if the
ambient light is dark enough, the ControlZAPP device will turn the load ON.
The ambient threshold can be set to between approximately 30 lux to 1000 lux
andinnitelux(photocellinactive)viathe‘RespondtoDaylight’settingsonthe
ControlZAPP App.
If no more movement is detected within a pre-selected time as determined by the
ControlZAPPApp,thentheControlZAPPdevicewillturntheloadoff.This‘Time
OffTimeout’ortimelagcanbesetviatheControlZAPPAppadjusterbetween
10sec and 23hrs 59min 59sec.
Loading
CZ CEFL DALI is suitable for switching and dimming DALI ballasts (broadcast only).
They can control up to 40mA, eg. 20 ballasts at 2mA (varies according to make and
model of ballasts).
CZ CEFL DALI can also switch up to:
• 10 amps (3000W) of resistive loads
• 6amps(1500W)uorescentlamps,highfrequencyorswitchstart,
incandescent or mains halogen lamps (recommended with integral safety fuse)
• 3 amps (750W) of electronic or wire wound transformers.
• 2 amps (500W) of low energy lamps: CFL, LED, 2D etc.
• 1 amp (250W) of fans or most metal halide lamps.
IMPORTANT: To control DALI ballasts you will require a DALI Power Supply Unit.
Please refer to your ballast instructions.
DANLERS DALI Power Supply Unit (order code DBPSU) is rated at 40mA (DALI
standard allows 250mA maximum). The controls interface of a DALI ballast normally
sources at 2mA.
Start-upmodeandDefaultsettings
When the CZ CEFL DALI is powered up, it will take 1 minute for the circuitry to
stabilise(detectionLEDashing)andensuretheoutputisoff,theCZCEFLDALI
will then enter its Default Operating Mode.
PleaseNote: When in the Default Operating Mode the CZ CEFL DALI is set up as
an occupancy switch with a 20 minute turn OFF timeout (time lag) and photocell
disabled.
Installation procedure
1. Please read these notes carefully before commencing work. In case of doubt
pleaseconsultaqualiedelectrician.Ensurewiresandcablesaresecurelyheld
within the connection terminals.
 IMPORTANT:TheCZCEFLDALIControlUnitclockbatterymustbeengaged
(ON)priortoinstallationbyswitchingtheREDdipswitch(seediagramD)to
theDOWNposition.
2. POSITIONING: The CZ CEFL DALI switch should be installed to achieve correct
coverage of the area, see diagram B.
If the photocell override facility (enabled via
ControlZAPP app) is required, the switch must be located above an area where
daylightcangivegreaterilluminationthanthearticiallight.Avoidlocatingthis
product where it is exposed to drafty conditions (exposed lobbies, open ceiling
voids or near fans) or near heat sources. To cover large areas PIRs should be
spaced in a 5 metre grid formation.
3. Disconnect the ControlZAPP device from the circuit before performing insulation
testing of the wiring circuit.
4. Do not connect on a circuit with large inductive loads, as induced spikes may
cause false triggering or damage the device.
5. CZ CEFL DALI must be connected to its ControlZAPP Power Supply via the
ControlZAPP communication cable provided, for wiring see diagram C.
NOTE: The use of non ControlZAPP connectors may damage the CZ CEFL DALI
device and will invalidate the warranty.
Settingsandcalibration
NOTE:ALLsettingsareadjustedbyControlZAPPAppasspeciedinthe
ControlZAPPAppUserGuide (downloadable from the DANLERS website)
including: MODE settings, SCHEDULER settings and photocell settings and
intelligent photocell calibration procedure.
MODE settings include: Detect Movement (enable or disable), Sensitivity, Short
Visit Mode (with timer), Turn ON automatically (Presence detection or Absence
detection), Turn OFF timeout (from10sec to 23hrs 59min 59sec), Respond to
Daylight (enabled or disabled) the calibration process must be run for the intelligent
photocell to work. Delay before ON or Delay before OFF timers, Scene Recall (ON
or OFF).
SCHEDULER settings include:
DAY TYPES(deningtimesforeachofthedifferentModestooccur).
WEEKLY SCHEDULE(deningwhichDayTypesareassignedtodifferentdaysof
the week).
EXCEPTIONS(deningexceptionstotheschedulesuchasholidays).
VIEW ON CALENDAR (overview of schedule).
L
N
DALI Power
Supply Unit*
DALI
Ballast
ControlZAPP device
CZ CEFL DALI
DALI Control Lines
DALI
Ballast
*DANLERS Order code: DBPSU
Optional
other load
100 - 260VAC 50/60Hz
SL
L
N
A:Mountingdiagram
B:Detectiondiagram
up to 5m
up to 7m
Strong detection zone
i.e. person moving arm
or walking towards PIR Secondary detection
zone i.e. person
walking perpendicular
to PIR
For optimum coverage
recommended
mounting height: 2.4 to 5m
C:Wiringdiagram
SL
L
L
N
Telejack connector Control Unit
Power Supply
Red dip switch (MUST be
switched DOWN (towards lens)
to engage clock battery ON)
IMPORTANT
DA
DA
D:Connectordiagram
CEILING VOID
(At least 78mm deep)
75mm circular hole
cut for PIR switch

Other DANLERS Switch manuals

DANLERS TLSW 10 ILM Quick start guide

DANLERS

DANLERS TLSW 10 ILM Quick start guide

DANLERS CEFL PIR LR Quick start guide

DANLERS

DANLERS CEFL PIR LR Quick start guide

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS COPIR IP66 User manual

DANLERS

DANLERS COPIR IP66 User manual

DANLERS GRTLA MK User manual

DANLERS

DANLERS GRTLA MK User manual

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS WAPIR Quick start guide

DANLERS

DANLERS WAPIR Quick start guide

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS CEFL PIR Quick start guide

DANLERS

DANLERS CEFL PIR Quick start guide

DANLERS WACE RFS Quick start guide

DANLERS

DANLERS WACE RFS Quick start guide

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS CESRA PIR DSIP Quick start guide

DANLERS

DANLERS CESRA PIR DSIP Quick start guide

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS CESFPIRSV Quick start guide

DANLERS

DANLERS CESFPIRSV Quick start guide

DANLERS GRTL MK Quick start guide

DANLERS

DANLERS GRTL MK Quick start guide

DANLERS CESRAPIRSD Quick start guide

DANLERS

DANLERS CESRAPIRSD Quick start guide

DANLERS BMEXPIR Quick start guide

DANLERS

DANLERS BMEXPIR Quick start guide

DANLERS DUSW Quick start guide

DANLERS

DANLERS DUSW Quick start guide

DANLERS CEPH NO Quick start guide

DANLERS

DANLERS CEPH NO Quick start guide

DANLERS TWSW Quick start guide

DANLERS

DANLERS TWSW Quick start guide

DANLERS EZ CESR Quick start guide

DANLERS

DANLERS EZ CESR Quick start guide

DANLERS GRTLA MK Quick start guide

DANLERS

DANLERS GRTLA MK Quick start guide

DANLERS CESF PIR Quick start guide

DANLERS

DANLERS CESF PIR Quick start guide

DANLERS CZ CEFL Quick start guide

DANLERS

DANLERS CZ CEFL Quick start guide

Popular Switch manuals by other brands

Hydac EDS 300 user manual

Hydac

Hydac EDS 300 user manual

MDT Technologies KNX AKK-0216.03 operating instructions

MDT Technologies

MDT Technologies KNX AKK-0216.03 operating instructions

SignaMax 065-7727S user guide

SignaMax

SignaMax 065-7727S user guide

ATEN KL9108 user manual

ATEN

ATEN KL9108 user manual

Dell S4810-ON installation guide

Dell

Dell S4810-ON installation guide

Vox Technologies KVM08KD manual

Vox Technologies

Vox Technologies KVM08KD manual

Allied Telesis AT-FS980M/28DP installation guide

Allied Telesis

Allied Telesis AT-FS980M/28DP installation guide

Harman AMX Precis PR Series Hardware reference manual

Harman

Harman AMX Precis PR Series Hardware reference manual

Haydon HAY-EXT120IRHDMI quick start guide

Haydon

Haydon HAY-EXT120IRHDMI quick start guide

StarTech.com 4PORT-8K-HDMI-SWITCH quick start guide

StarTech.com

StarTech.com 4PORT-8K-HDMI-SWITCH quick start guide

EtherWAN EX24000 user guide

EtherWAN

EtherWAN EX24000 user guide

Ubiquiti USW-Flex quick start guide

Ubiquiti

Ubiquiti USW-Flex quick start guide

gofanco USBCMST3VID user guide

gofanco

gofanco USBCMST3VID user guide

Emerson PENBERTHY MGS-314L Series Installation, operation and maintenance instructions

Emerson

Emerson PENBERTHY MGS-314L Series Installation, operation and maintenance instructions

Cisco 3020 - Cisco Catalyst Blade Switch Getting started guide

Cisco

Cisco 3020 - Cisco Catalyst Blade Switch Getting started guide

Emos TF-16 quick guide

Emos

Emos TF-16 quick guide

Lanberg DSP2 Series manual

Lanberg

Lanberg DSP2 Series manual

PRO SIGNAL PSG3450 manual

PRO SIGNAL

PRO SIGNAL PSG3450 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.