manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DANLERS
  6. •
  7. Switch
  8. •
  9. DANLERS ControlZAPP CZ CEFL 10VDC Quick start guide

DANLERS ControlZAPP CZ CEFL 10VDC Quick start guide

Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products
Please call for more information or a free catalogue, or visit our website.
This product conforms to BS EN 60669-2-1, BS EN 55015 and BS EN 60730.
Please ensure the most recent edition of the appropriate local wiring regulations are observed
and suitable protection is provided (protected with the appropriate MCB) 1kV over voltage.
Please ensure that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Precautions and Warranty
08/09/16 INS010 CZ CEFL 10VDC
Variants
DANLERS design and manufacture other ControlZAPP CZCEFLP variants, coded
by the following order codes:
CZ CEFL Suitable for mains switching
CZ CEFL VF Suitable for mains switching, Volt Free contacts
CZ CEFL 10VDCVF Suitable for 1-10VDC ballasts, Volt Free contacts
CZ CEFL DALI Suitable for DALI ballasts
CZ CEFL DALIVF Suitable for DALI ballasts, Volt Free contacts
Troubleshooting
The load will not switch on:
•TheLUXsettingasspeciedbytheControlZAPPAppissettoolowandis
inhibiting the switch.
• The moving body is not emitting more IR than the background.
(Person wearing insulating clothing in a warm environment)
• Person is too far from the PIR switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing).
• The control unit battery is not engaged (ON).
Switch RED dip switch next to the telejack connector on the control
unit to the DOWN position.
The load switches on when nobody is present:
• Heater causing infra-red variations in a small cold room.
Resite the CZ CEFL 10VDC control away from heater.
• Please contact DANLERS for further technical support.
 ControlZAPPCeilingushmountedswitches
CZ CEFL 10VDC
ControlZAPPceilingushmountedmultifunctionaldevicescanbeushmounted
into suspended and plasterboard ceilings (diagram A).
ControlZAPP devices incorporate a passive infra-red quad sensor to detect
movement of a warm body within their detection zone (diagram B) and a photocell
to monitor the ambient light level.
ALLadjustmentsaremadeviaafreelydownloadableControlZAPPApp
availablefromtheDANLERSwebsite.
If CZ CEFL 10VDC is set as PIR with LUX input, upon detecting movement, if
the ambient light is dark enough, the ControlZAPP device will turn the load ON.
The ambient threshold can be set to between approximately 30 lux to 1000 lux
andinnitelux(photocellinactive)viathe‘RespondtoDaylight’settingsonthe
ControlZAPP App.
If no more movement is detected within a pre-selected time as determined by the
ControlZAPPApp,thentheControlZAPPdevicewillturntheloadoff.This‘Time
OffTimeout’ortimelagcanbesetviatheControlZAPPAppadjusterbetween
10sec and 23hrs 59min 59sec.
Loading
CZ CEFL 10VDC is suitable for switching and dimming 1-10VDC ballasts.
CZ CEFL 10VDC can control up to 20mA, eg. 20 ballasts at 1mA (varies according
to make and model of ballasts).
CZ CEFL 10VDC can also switch up to:
• 10 amps (3000W) of resistive loads
• 6amps(1500W)uorescentlamps,highfrequencyorswitchstart,
incandescent or mains halogen lamps (recommended with integral safety fuse)
• 3 amps (750W) of electronic or wire wound transformers.
• 2 amps (500W) of low energy lamps: CFL, LED, 2D etc.
• 1 amp (250W) of fans or most metal halide lamps.
Start-upmodeandDefaultsettings
When the CZ CEFL 10VDC is powered up, it will take 1 minute for the circuitry to
stabilise(detectionLEDashing)andensuretheoutputisoff,theCZCEFL10VDC
will then enter its Default Operating Mode.
PleaseNote: When in the Default Operating Mode the CZ CEFL 10VDC is set up
as an occupancy switch with a 20 minute turn OFF timeout (time lag) and photocell
disabled.
Installation procedure
1. Please read these notes carefully before commencing work. In case of doubt
pleaseconsultaqualiedelectrician.Ensurewiresandcablesaresecurelyheld
within the connection terminals.
 IMPORTANT:TheCZCEFL10VDCControlUnitclockbatterymustbe
engaged(ON)priortoinstallationbyswitchingtheREDdipswitch(see
diagramD)totheDOWNposition.
2. POSITIONING: The CZ CEFL 10VDC switch should be installed to achieve
correct coverage of the area, see diagram B.
If the photocell override facility
(enabled via ControlZAPP app) is required, the switch must be located above
anareawheredaylightcangivegreaterilluminationthanthearticiallight.Avoid
locating this product where it is exposed to drafty conditions (exposed lobbies,
open ceiling voids or near fans) or near heat sources. To cover large areas PIRs
should be spaced in a 5 metre grid formation.
3. Disconnect the ControlZAPP device from the circuit before performing insulation
testing of the wiring circuit.
4. Do not connect on a circuit with large inductive loads, as induced spikes may
cause false triggering or damage the device.
5. CZ CEFL 10VDC must be connected to its ControlZAPP Power Supply via the
ControlZAPP communication cable provided, for wiring see diagram C.
NOTE: The use of non ControlZAPP connectors may damage the CZ CEFL
10VDC device and will invalidate the warranty.
Settingsandcalibration
NOTE:ALLsettingsareadjustedbyControlZAPPAppasspeciedinthe
ControlZAPPAppUserGuide (downloadable from the DANLERS website)
including: MODE settings, SCHEDULER settings and photocell settings and
intelligent photocell calibration procedure.
MODE settings include: Detect Movement (enable or disable), Sensitivity, Short
Visit Mode (with timer), Turn ON automatically (Presence detection or Absence
detection), Turn OFF timeout (from10sec to 23hrs 59min 59sec), Respond to
Daylight (enabled or disabled) the calibration process must be run for the intelligent
photocell to work. Delay before ON or Delay before OFF timers, Scene Recall (ON
or OFF).
SCHEDULER settings include:
DAY TYPES(deningtimesforeachofthedifferentModestooccur).
WEEKLY SCHEDULE(deningwhichDayTypesareassignedtodifferentdaysof
the week).
EXCEPTIONS(deningexceptionstotheschedulesuchasholidays).
VIEW ON CALENDAR (overview of schedule).
L
N
100 - 260VAC
50/60Hz
CZ CEFL 10VDC
+
ballast
-
control lines
NSL
+
_
Optional
other load
+
ballast
-
+
ballast
-
A:Mountingdiagram
B:Detectiondiagram
up to 5m
up to 7m
Strong detection zone
i.e. person moving arm
or walking towards PIR Secondary detection
zone i.e. person
walking perpendicular
to PIR
For optimum coverage
recommended
mounting height: 2.4 to 5m
C:Wiringdiagram
D:Connectordiagram
SL
L
L
N
Telejack connector Control Unit
Power Supply
Red dip switch (MUST be
switched DOWN (towards lens)
to engage clock battery ON)
IMPORTANT
+
-
CEILING VOID
(At least 78mm deep)
75mm circular hole
cut for PIR switch

Other DANLERS Switch manuals

DANLERS CESFPIRSV Quick start guide

DANLERS

DANLERS CESFPIRSV Quick start guide

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS BMPIR10M Quick start guide

DANLERS

DANLERS BMPIR10M Quick start guide

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS CZ CEFL Quick start guide

DANLERS

DANLERS CZ CEFL Quick start guide

DANLERS WAPIR Quick start guide

DANLERS

DANLERS WAPIR Quick start guide

DANLERS TLSW HB Quick start guide

DANLERS

DANLERS TLSW HB Quick start guide

DANLERS TWSW Quick start guide

DANLERS

DANLERS TWSW Quick start guide

DANLERS COPIR IP66 User manual

DANLERS

DANLERS COPIR IP66 User manual

DANLERS GRTLA MK Quick start guide

DANLERS

DANLERS GRTLA MK Quick start guide

DANLERS CESRAPIRSD Quick start guide

DANLERS

DANLERS CESRAPIRSD Quick start guide

DANLERS BMEXPIR Quick start guide

DANLERS

DANLERS BMEXPIR Quick start guide

DANLERS ControlZAPP CZ CEFL DALI Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL DALI Quick start guide

DANLERS CEFL PIR LR Quick start guide

DANLERS

DANLERS CEFL PIR LR Quick start guide

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS DUSW Quick start guide

DANLERS

DANLERS DUSW Quick start guide

DANLERS CEFL PIR Quick start guide

DANLERS

DANLERS CEFL PIR Quick start guide

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS CESF PIR IP66 Quick start guide

DANLERS

DANLERS CESF PIR IP66 Quick start guide

DANLERS CEPH NO Quick start guide

DANLERS

DANLERS CEPH NO Quick start guide

DANLERS CEFLAPIR Quick start guide

DANLERS

DANLERS CEFLAPIR Quick start guide

DANLERS GRTL MK Quick start guide

DANLERS

DANLERS GRTL MK Quick start guide

Popular Switch manuals by other brands

TP-Link JetStream TL-SL3452 reference guide

TP-Link

TP-Link JetStream TL-SL3452 reference guide

SIIG 1394 Quick installation guide

SIIG

SIIG 1394 Quick installation guide

BABBITT LS8500 owner's manual

BABBITT

BABBITT LS8500 owner's manual

Milestone pro MP-SU21T-KVM user manual

Milestone pro

Milestone pro MP-SU21T-KVM user manual

Omron E3JM - manual

Omron

Omron E3JM - manual

Omron ER5018 datasheet

Omron

Omron ER5018 datasheet

RJM ARTS-201B user manual

RJM

RJM ARTS-201B user manual

schmersal AZ 15 ZO operating instructions

schmersal

schmersal AZ 15 ZO operating instructions

IOGear GCS1792 installation guide

IOGear

IOGear GCS1792 installation guide

Cross Technologies 2582-122 instruction manual

Cross Technologies

Cross Technologies 2582-122 instruction manual

D-Link xStack DGS-3120-48PC Hardware installation guide

D-Link

D-Link xStack DGS-3120-48PC Hardware installation guide

Hubbell Reversing Drum Controller 58-GJ2 Replacement parts

Hubbell

Hubbell Reversing Drum Controller 58-GJ2 Replacement parts

GarrettCom Magnum 6K8-Series Hardware installation and user's guide

GarrettCom

GarrettCom Magnum 6K8-Series Hardware installation and user's guide

Siemens 3RV1991-1BA0 operating instructions

Siemens

Siemens 3RV1991-1BA0 operating instructions

Lenovo Flex System FC5022 Product guide

Lenovo

Lenovo Flex System FC5022 Product guide

Exsys EX-1112HMS manual

Exsys

Exsys EX-1112HMS manual

DigiGrid S user guide

DigiGrid

DigiGrid S user guide

SignaMax C-300 Series quick start guide

SignaMax

SignaMax C-300 Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.