Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products
Please call for more information or a free catalogue, or visit our website.
This product conforms to BS EN 60669-2-1, BS EN 55015 and BS EN 60730.
Please ensure the most recent edition of the appropriate local wiring regulations are observed
and suitable protection is provided (protected with the appropriate MCB) 1kV over voltage.
Please ensure that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Precautions and Warranty
08/09/16 INS010 CZ CEFL 10VDC
Variants
DANLERS design and manufacture other ControlZAPP CZCEFLP variants, coded
by the following order codes:
CZ CEFL Suitable for mains switching
CZ CEFL VF Suitable for mains switching, Volt Free contacts
CZ CEFL 10VDCVF Suitable for 1-10VDC ballasts, Volt Free contacts
CZ CEFL DALI Suitable for DALI ballasts
CZ CEFL DALIVF Suitable for DALI ballasts, Volt Free contacts
Troubleshooting
The load will not switch on:
•TheLUXsettingasspeciedbytheControlZAPPAppissettoolowandis
inhibiting the switch.
• The moving body is not emitting more IR than the background.
(Person wearing insulating clothing in a warm environment)
• Person is too far from the PIR switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing).
• The control unit battery is not engaged (ON).
Switch RED dip switch next to the telejack connector on the control
unit to the DOWN position.
The load switches on when nobody is present:
• Heater causing infra-red variations in a small cold room.
Resite the CZ CEFL 10VDC control away from heater.
• Please contact DANLERS for further technical support.
 ControlZAPPCeilingushmountedswitches
CZ CEFL 10VDC
ControlZAPPceilingushmountedmultifunctionaldevicescanbeushmounted
into suspended and plasterboard ceilings (diagram A).
ControlZAPP devices incorporate a passive infra-red quad sensor to detect
movement of a warm body within their detection zone (diagram B) and a photocell
to monitor the ambient light level.
ALLadjustmentsaremadeviaafreelydownloadableControlZAPPApp
availablefromtheDANLERSwebsite.
If CZ CEFL 10VDC is set as PIR with LUX input, upon detecting movement, if
the ambient light is dark enough, the ControlZAPP device will turn the load ON.
The ambient threshold can be set to between approximately 30 lux to 1000 lux
andinnitelux(photocellinactive)viathe‘RespondtoDaylight’settingsonthe
ControlZAPP App.
If no more movement is detected within a pre-selected time as determined by the
ControlZAPPApp,thentheControlZAPPdevicewillturntheloadoff.This‘Time
OffTimeout’ortimelagcanbesetviatheControlZAPPAppadjusterbetween
10sec and 23hrs 59min 59sec.
Loading
CZ CEFL 10VDC is suitable for switching and dimming 1-10VDC ballasts.
CZ CEFL 10VDC can control up to 20mA, eg. 20 ballasts at 1mA (varies according
to make and model of ballasts).
CZ CEFL 10VDC can also switch up to:
• 10 amps (3000W) of resistive loads
• 6amps(1500W)uorescentlamps,highfrequencyorswitchstart,
incandescent or mains halogen lamps (recommended with integral safety fuse)
• 3 amps (750W) of electronic or wire wound transformers.
• 2 amps (500W) of low energy lamps: CFL, LED, 2D etc.
• 1 amp (250W) of fans or most metal halide lamps.
Start-upmodeandDefaultsettings
When the CZ CEFL 10VDC is powered up, it will take 1 minute for the circuitry to
stabilise(detectionLEDashing)andensuretheoutputisoff,theCZCEFL10VDC
will then enter its Default Operating Mode.
PleaseNote: When in the Default Operating Mode the CZ CEFL 10VDC is set up
as an occupancy switch with a 20 minute turn OFF timeout (time lag) and photocell
disabled.
Installation procedure
1. Please read these notes carefully before commencing work. In case of doubt
pleaseconsultaqualiedelectrician.Ensurewiresandcablesaresecurelyheld
within the connection terminals.
 IMPORTANT:TheCZCEFL10VDCControlUnitclockbatterymustbe
engaged(ON)priortoinstallationbyswitchingtheREDdipswitch(see
diagramD)totheDOWNposition.
2. POSITIONING: The CZ CEFL 10VDC switch should be installed to achieve
correct coverage of the area, see diagram B.
If the photocell override facility
(enabled via ControlZAPP app) is required, the switch must be located above
anareawheredaylightcangivegreaterilluminationthanthearticiallight.Avoid
locating this product where it is exposed to drafty conditions (exposed lobbies,
open ceiling voids or near fans) or near heat sources. To cover large areas PIRs
should be spaced in a 5 metre grid formation.
3. Disconnect the ControlZAPP device from the circuit before performing insulation
testing of the wiring circuit.
4. Do not connect on a circuit with large inductive loads, as induced spikes may
cause false triggering or damage the device.
5. CZ CEFL 10VDC must be connected to its ControlZAPP Power Supply via the
ControlZAPP communication cable provided, for wiring see diagram C.
NOTE: The use of non ControlZAPP connectors may damage the CZ CEFL
10VDC device and will invalidate the warranty.
Settingsandcalibration
NOTE:ALLsettingsareadjustedbyControlZAPPAppasspeciedinthe
ControlZAPPAppUserGuide (downloadable from the DANLERS website)
including: MODE settings, SCHEDULER settings and photocell settings and
intelligent photocell calibration procedure.
MODE settings include: Detect Movement (enable or disable), Sensitivity, Short
Visit Mode (with timer), Turn ON automatically (Presence detection or Absence
detection), Turn OFF timeout (from10sec to 23hrs 59min 59sec), Respond to
Daylight (enabled or disabled) the calibration process must be run for the intelligent
photocell to work. Delay before ON or Delay before OFF timers, Scene Recall (ON
or OFF).
SCHEDULER settings include:
DAY TYPES(deningtimesforeachofthedifferentModestooccur).
WEEKLY SCHEDULE(deningwhichDayTypesareassignedtodifferentdaysof
the week).
EXCEPTIONS(deningexceptionstotheschedulesuchasholidays).
VIEW ON CALENDAR (overview of schedule).
L
N
100 - 260VAC
50/60Hz
CZ CEFL 10VDC
+
ballast
-
control lines
NSL
+
_
Optional
other load
+
ballast
-
+
ballast
-
A:Mountingdiagram
B:Detectiondiagram
up to 5m
up to 7m
Strong detection zone
i.e. person moving arm
or walking towards PIR Secondary detection
zone i.e. person
walking perpendicular
to PIR
For optimum coverage
recommended
mounting height: 2.4 to 5m
C:Wiringdiagram
D:Connectordiagram
SL
L
L
N
Telejack connector Control Unit
Power Supply
Red dip switch (MUST be
switched DOWN (towards lens)
to engage clock battery ON)
IMPORTANT
+
-
CEILING VOID
(At least 78mm deep)
75mm circular hole
cut for PIR switch

Other DANLERS Switch manuals

DANLERS CEPH NO Quick start guide

DANLERS

DANLERS CEPH NO Quick start guide

DANLERS CESFPIRSV Quick start guide

DANLERS

DANLERS CESFPIRSV Quick start guide

DANLERS TWSW Quick start guide

DANLERS

DANLERS TWSW Quick start guide

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS TLSW 10 ILM Quick start guide

DANLERS

DANLERS TLSW 10 ILM Quick start guide

DANLERS CZ HB ND Quick start guide

DANLERS

DANLERS CZ HB ND Quick start guide

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS WACE RFS Quick start guide

DANLERS

DANLERS WACE RFS Quick start guide

DANLERS TLSW HB Quick start guide

DANLERS

DANLERS TLSW HB Quick start guide

DANLERS TLSW HB Quick start guide

DANLERS

DANLERS TLSW HB Quick start guide

DANLERS CESF PIR Quick start guide

DANLERS

DANLERS CESF PIR Quick start guide

DANLERS BMPIR10M Quick start guide

DANLERS

DANLERS BMPIR10M Quick start guide

DANLERS CEFL PIR Quick start guide

DANLERS

DANLERS CEFL PIR Quick start guide

DANLERS GRTLA MK Quick start guide

DANLERS

DANLERS GRTLA MK Quick start guide

DANLERS GRTL MK Quick start guide

DANLERS

DANLERS GRTL MK Quick start guide

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS TLSW A20 Quick start guide

DANLERS

DANLERS TLSW A20 Quick start guide

DANLERS COPIR IP66 User manual

DANLERS

DANLERS COPIR IP66 User manual

DANLERS WAPIR Quick start guide

DANLERS

DANLERS WAPIR Quick start guide

DANLERS CEFLAPIR Quick start guide

DANLERS

DANLERS CEFLAPIR Quick start guide

DANLERS BMEXPIR Quick start guide

DANLERS

DANLERS BMEXPIR Quick start guide

DANLERS DUSW Quick start guide

DANLERS

DANLERS DUSW Quick start guide

DANLERS GRTLA MK User manual

DANLERS

DANLERS GRTLA MK User manual

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS

DANLERS CEFLA PIR DSIP Quick start guide

Popular Switch manuals by other brands

Smart Node Touch Switches TS.2S NL Product Guidance

Smart Node

Smart Node Touch Switches TS.2S NL Product Guidance

Tinysine LazyBone TOSR-10B user manual

Tinysine

Tinysine LazyBone TOSR-10B user manual

ADTRAN DDM+ H2TU-C Job aid

ADTRAN

ADTRAN DDM+ H2TU-C Job aid

WEIGL ProCommander Wiring diagram

WEIGL

WEIGL ProCommander Wiring diagram

Hawking HKS112AU user guide

Hawking

Hawking HKS112AU user guide

PureTools PT-SW-HD3 user manual

PureTools

PureTools PT-SW-HD3 user manual

Broadcast Tools DMS-III Installation and operation manual

Broadcast Tools

Broadcast Tools DMS-III Installation and operation manual

Baumer CleverLevel LFFS-1 Series operating instructions

Baumer

Baumer CleverLevel LFFS-1 Series operating instructions

Brocade Communications Systems FESX624HF installation guide

Brocade Communications Systems

Brocade Communications Systems FESX624HF installation guide

WyreStorm Digital Integrity Network HD instruction manual

WyreStorm Digital Integrity

WyreStorm Digital Integrity Network HD instruction manual

EtherWAN EX26262F Series installation guide

EtherWAN

EtherWAN EX26262F Series installation guide

Altusen ALTUSEN KH2508 Quick start quide

Altusen

Altusen ALTUSEN KH2508 Quick start quide

Milesight LoRaWAN WS50 Series user guide

Milesight

Milesight LoRaWAN WS50 Series user guide

HP 5300 Reviewer's guide

HP

HP 5300 Reviewer's guide

Ubiquiti UniFi USW-Pro-48-POE quick start guide

Ubiquiti

Ubiquiti UniFi USW-Pro-48-POE quick start guide

Homematic IP HmIP-PSM-2 operating manual

Homematic IP

Homematic IP HmIP-PSM-2 operating manual

Profi-pumpe AC23A operating instructions

Profi-pumpe

Profi-pumpe AC23A operating instructions

Cisco 11506 - CSS Content Services Switch datasheet

Cisco

Cisco 11506 - CSS Content Services Switch datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.