17
Monitor • Control • Surveillance
16
Monitor • Control • Surveillance
Acvate when zone open without auto offfeature - Acvate when zone open and deacvate
manually
Zone 1 - 000 Zone 3 - 002 Zone 5 - 004 Zone 7 - 006
Zone 2 - 001 Zone 4 - 003 Zone 6 - 005 Zone 8 - 007
Acvate when zone open with auto offfeature - Acvate when zone open and deacvate when the
auto offme exceed
Zone 1 - 016 Zone 3 - 018 Zone 5 - 020 Zone 7 - 022
Zone 2 - 017 Zone 4 - 019 Zone 6 - 021 Zone 8 - 023
Control mer 1 - The home automaon output will acvate follow control mer 1.
Control mer 2 - The home automaon output will acvate follow control mer 2.
Control mer 1 & 2 - The home automaon output will acvate follow control mer 1 & 2.
Acvate during entry / exit me without auto offfeature - Acvate when system arm deacvate by
manually.
Acvate during entry / exit me with auto offfeature - The home automaon output will pulse 1
second when the system is arm, pulse 2 second when the system is disarm.
Follow zone trigger - Acvate when zone trigger and deacvate when system disarm.
Manual On / Off- It can be turn on or offmanually through keypad, telephone or internet.
Acvate when full arm - It will acvate the system is arm, deacvate when system is disarm.
Acvate when trouble condion exit - Acvate when the panel detect trouble.
Acvate when zone trigger auto offaer me exceed - It will only funcon when the system is arm,
acvate when zone trigger auto offaer me exceed.
Acvate when zone trigger auto offaer disarm - It will only funcon when the system is arm, acvate
when zone trigger auto offaer disarm.
Technical Data
Home Automaon
Zone Open Without Auto OffFeature
Zone Open With Auto OffFeature
Control follow Timer 1
Zone Open with Auto OffFeature during Night Mode
Zone Open without Auto OffFeature during Night Mode
Control follow Timer 2
Control follow Timer 1 & 2
Acvate during away arm without auto offfeature
Acvate during away arm with auto offfeature
Acvate during away arm with auto offfeature during Night Mode
Acvate during away arm without auto offfeature during Night Mode
Acvate follow zone trigger
Manual On/ Off
Acvate follow zone trigger (Pulse signal)
Acvate when trouble condion exist
Acvate when fully arm
Acvate when zone trigger auto offaer me exceed
Acvate when zone trigger auto offaer disarm 107
068
071 - 086
070
069
103
087 - 094
104
105
106
067
066
065
064
016 - 023
048 - 055
032 - 039
000 - 007
Value
Technical Data
Default master code [ 1234 ]
The password must be [ 4 digit ]
Maximum 8 user code and 1 master code
Maximum 4 user phone number
Smart Dialer Operaon Summary
To disarm the system Key in password
Press [ H ] 3 sec
Press [ A ] 3 sec
Press [ * ] [ 4 ] [master code] [zone] [ # ]
Press [ * ] [ 6 ] [master code] [ 0 ]
[new master code 2 time]
Press [ * ] [ 6 ] [master code] [user number]
Press [ * ] [ 6 ] [master code] [user number] [ * ]
Press [ * ] [ 7 ] [master code] [user] [phone number]
Press [ * ] [ 81 ] [zone number]
Press [ * ] [ 91 ] on/o home automation 1
Press [ * ] [ 92 ] on/o home automation 2
Press [ * ] [ 95 ] on all home automation
Press [ * ] [ 96 ] o all home automation
Press [ * ] [ 83 ]
Press [ # ]
Press [ * ] [ 50 ] 1. AC Fail
2. Battery Low
3. Time Fail
4. Date Fail
[new user code 2 time]
Press [ * ] [ 5 ]
To arm in home mode
To arm in away mode
To bypass zone
Display memory
Change master code
Add user code
Deled user code
Set phone number
Display trouble
To turn chime mode on or off
Tesng CMS
Home automaon
To exit
Key
0
1
2
3
# Hang off
Bypass Zone
Home Automaon
Disarm System
Arm System
Status
Keypad Command Summary