DITEC FACIL Series User manual

Ditec FACIL
Swing gates automation
(translation of the original instructions)
Technical Manual
IP2132EN•2023-05-03
www.ditecautomations.com
Last version of this manual

24
IP2132EN
This symbol indicates useful information for the correct operation of the product.
This symbol indicates instructions or notes relating to safety which require special attention.
Legend
Index
General safety precautions .......................................................................................................................... 25
Declaration of incorporation of partly completed machinery .................................................................................. 26
UK Declaration of Conformity .......................................................................................................................... 27
1. Technical data .............................................................................................................................................. 28
1.1 Operating instructions ................................................................................................................................. 29
1.2 Machinery Directive ................................................................................................................................ 29
2. Standard installation .......................................................................................................................... 30
3. Dimensions .............................................................................................................................................. 31
4. Installation .............................................................................................................................................. 32
4.1 Preliminary checks ................................................................................................................................. 32
4.2 Bracket fastening ................................................................................................................................. 33
4.3 Gearmotor installation ................................................................................................................................. 34
4.4 Limit switch installation and adjustment (optional) ....................................................................................... 35
5. Electrical connections .......................................................................................................................... 36
6. Routine maintenance plan .......................................................................................................................... 37
Operating instructions .............................................................................................................................................. 38
Manual release instructions ................................................................................................................................ 40

25
IP2132EN
General safety precautions
This installation manual is intended for qualified personnel only • Installation, electrical connec-
tions and adjustments must be performed by qualified personnel, in accordance with Good Working
Methods and in compliance with the current regulations • Read the instructions carefully before
installing the product. Wrong installation could be dangerous • Before installing the product, make
sure it is in perfect condition.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment
or left within reach of children, as they are a potential source of danger • Do not install the
product in explosive areas and atmospheres: the presence of inflammable gas or fumes represents
a serious safety hazard • Make sure that the temperature range indicated in the technical speci-
fications is compatible with the installation site • Before installing the motorization device, make
sure that the existing structure, as well as all the support and guide elements, are up to standards
in terms of strength and stability. Verify the stability and smooth mobility of the guided part, and
make sure that no risks of fall or derailment subsist. Make all the necessary structural modifica-
tions to create safety clearance and to guard or isolate all the crushing, shearing, trapping and
general hazardous areas • The motorization device manufacturer is not responsible for failure to
observe Good Working Methods when building the frames to be motorized, or for any deformation
during use • The safety devices (photocells, safety edges, emergency stops, etc.) must be installed
taking into account the applicable laws and directives, Good Working Methods, installation prem-
ises, system operating logic and the forces developed by the motorized door or gate • The safety
devices must protect against crushing, cutting, trapping and general danger areas of the motorized
door or gate. Display the signs required by law to identify hazardous areas • Each installation must
bear a visible indication of the data identifying the motorized door or gate • Before connecting the
power supply, make sure the plate data correspond to those of the mains power supply. An om-
nipolar disconnection switch with a contact opening distance of at least 3 mm must be fitted on
the mains supply. Check that there is an adequate residual current circuit breaker and a suitable
overcurrent cutout upstream of the electrical installation in accordance with Good Working Meth-
ods and with the laws in force • When requested, connect the motorized door or gate to an effec-
tive earthing system that complies with the current safety standards • Before commissioning the
installation to the end user, make sure that the automation is adequately adjusted in order to
satisfy all the functional and safety requirements, and that all the command, safety, and manual
release devices operate correctly.
During maintenance and repair operations, cut off the power supply before opening the
cover to access the electrical parts • The protection cover of the operator must be removed
by qualified personnel only.
The electronic parts must be handled using earthed antistatic conductive arms. The manu-
facturer of the motorization declines all responsibility if component parts not compatible with
safe and correct operation are fitted • Only use original spare parts for repairing or replacing
products • The installer must supply all information concerning the automatic, manual and emer-
gency operation of the motorized door or gate, and must provide the user with the operation and
safety instructions
ATTENTION! Important safety instructions.Please follow these instructions carefully.
Failure to observe the information given in this manual may lead to severe personal injury or
damage to the equipment.Keep these instructions for future reference.
This manual and those for any accessories can be downloaded from www.ditecautomations.com

26
IP2132EN
Declaration of incorporation of partly completed machinery
(Directive 2006/42/EC, Annex II-B)
We,
ASSA ABLOY Entrance Systems AB
Lodjursgatan 10
SE-261 44 Landskrona
Sweden,
declare, under our sole responsibility, that the type of equipment with the name:
Ditec FACIL Automation for swing gates
complies with the following directives and their amendments:
2006/42/EC Machinery Directive (MD), regarding the following essential health and safety requirements:
1.1.2, 1.1.3, 1.2.1, 1.2.2, 1.2.3, 1.2.4.2, 1.2.6, 1.3.9, 1.4.3, 1.7.2, 1.7.3, 1.7.4, 1.7.4.1, 1.7.4.2.
2014/30/EU Electromagnetic Compatibility Directive (EMCD)
2014/35/EU Radio Equipment Directive (RED)
2011/65/EU Restriction of Hazardous Substances (RoHS 2)
2015/863/EU Restriction of Hazardous Substances (RoHS Amendment 2)
Harmonised European standards which have been applied:
EN 61000-6-3:2007 + A1:2011 + AC:2012
EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021
Other standards or technical specifications which have been applied:
IEC 60335-1:2010 + C1:2010 + C2:2011 + A2:2013 + C1:2014 + A2:2016 + C1:2016
EN 12453:2017
The manufacturing process guarantees that the equipment complies with the technical documentation.
Responsible for the technical documentation:
Matteo Fino
BSP Ind channel & Gate Automation
Ditec S.p.A.
Largo U. Boccioni, 1
21040 Origgio (VA)
Italy
Signed on behalf of ASSA ABLOY Entrance Systems AB by:
Place Date Signature Position
Origgio 2023-05-03 Matteo Fino Head of Ind channel & Gate Automation
© ASSA ABLOY, All rights reserved

27
IP2132EN
UK Declaration of Conformity
We:
ASSA ABLOY Entrance Systems AB
Lodjursgatan 10
SE-261 44 Landskrona
Sweden
Declare under our sole responsibility that the types of equipment with names:
Ditec FACIL Automation for swing gates
complies with the following directives and their amendments:
• Supply of Machinery (Safety) Regulations 2016
• Electromagnetic Compatibility Regulations 2016
• Radio Equipment Regulations 2017
• The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equip-
ment Regulations 2012 (RoHS)
Harmonized European standards that have been applied:
EN 61000-6-3:2007 + A1:2011 + AC:2012
EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021
Other standards or technical specifications that have been applied:
IEC 60335-1:2010 + C1:2010 + C2:2011 + A2:2013 + C1:2014 + A2:2016 + C1:2016
EN 12453:2017
The manufacturing process ensures the compliance of the equipment with the technical file.
Responsible for technical file:
Matteo Fino
BSP Ind channel & Gate Automation
Ditec S.p.A.
Largo U. Boccioni, 1
21040 Origgio (VA)
Italy
Signed for and on behalf of ASSA ABLOY Entrance Systems AB by:
Place Date Signature Position
Origgio 2023-05-03 Matteo Fino Head of Ind channel & Gate Automation
© ASSA ABLOY, All rights reserved

28
IP2132EN
1. Technical data
FACIL3H FACIL3EH
Power supply 24 V 230 V~ 50/60 Hz
Absorption 6 A 0,6 A
Torque 200 Nm
Opening time 12÷32 s / 90°
Maximum weight 300 kg
Leaf width (max) 2,3 m
Max. opening 110°
Service class 3 - FREQUENT
(tested up to 150.000 cycles)
Intermittence S2= 30 min (T= 25°C)
S3= 50% (T= 25°C)
Cycles / hour *45 (T= 25°C)
Continuous cycles ** 41 (T= 25°C)
Operating temperature (T) (with NIO enabled)
-20°C +55°C -35°C +55°C
Degree of protection IP54
Control panel coupled to FACIL3EH or LCU40H LCU30H incorporated
Applications
m = leaf width
kg = leaf weight
500
400
300
200
100
[m]
[kg]
12345
*Indicative cycles consider a time per opening/closing maneuver of 20 sec and pause
time of 20 sec. Full cycle time of 80 sec.
** Indicative cycles consider a time per opening/closing maneuver of 20 sec and pause
time of 2 sec. Full cycle time of 44 sec.

29
IP2132EN
1.1 Operating instructions
Use: FREQUENT (for vehicle or pedestrian for single-family or multi-family with frequent use).
- Performance characteristics are to be understood as referring to the recommended weight (ap-
prox. 2/3 of maximum permissible weight). A reduction in performance is to be expected when
the access is made to operate at the maximum permissible weight.
- Service class, running times, and the number of consecutive cycles are to be taken as merely
indicative having been statistically determined under average operating conditions, and are
therefore not necessarily applicable to specific conditions of use. During given time spans
product performance characteristics will be such as not to require any special maintenance.
- The actual performance characteristics of each automatic access may be affected by independent
variables such as friction, balancing and environmental factors, all of which may substantially
alter the performance characteristics of the automatic access or curtail its working life or parts
thereof (including the automatic devices themselves). When setting up, specific local conditions
must be duly borne in mind and the installation adapted accordingly for ensuring maximum
durability and trouble-free operation.
1.2 Machinery Directive
Pursuant to Machinery Directive (2006/42/EC) the installer who motorizes a door or gate has the
same obligations as the manufacturer of machinery and as such must:
- prepare the technical file which must contain the documents indicated in Annex V of the Ma-
chinery Directive;
(The technical file must be kept and placed at the disposal of competent national authorities for
at least ten years from the date of manufacture of the motorized door);
- draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery Direc-
tive and deliver it to the customer;
- affix the EC marking on the motorized door in accordance with point 1.7.3 of Annex I of the
Machinery Directive.

30
IP2132EN
2. Standard installation
Ref. Code Description Cable
A
Connector block (not supplied).
Connect the power supply to an approved omnipolar switch with an opening distance
of the contacts of at least 3mm (not supplied).
The connection to the mains must be made via an independent channel, separated
from the connections to command and safety devices.
1FACIL3H Gearmotor 2 x 1,5 mm²
FACIL3EH Gearmotor and control panel incorporated 3G x 1.5 mm²
2LCU30H-HJ Control panel 3G x 1.5 mm²
3ZEN Transmitter /
4
AXK4 Digital combination wireless keypad /
AXK5M
AXK5N
AXK5NM
AXK5NI
Wall-mounted key-operated selector switch with European cylinder
Semi-recessed key-operated selector switch with European cylinder
Wall-mounted key-operated selector switch without cylinder
Semi-recessed key-operated selector switch without cylinder
4 x 0.5 mm²
AXR7 RFID reader unit 5 x 0.5 mm²
5
LIN2
LIN2B
AXP2
LAB4
Photocells 4 x 0.5 mm²
6LAB9 Magnetic loop 2 x 1,5 mm²
7
FLM
FL24
Flash clignotant 2 x 1 mm²
Antenna (integrated in the flashing light) coax cable RG-58
(50 Ω)
A
1
1
2
7
4
5
5
3
5
6
5

31
IP2132EN
3. Dimensions
333
188
285
285

32
IP2132EN
4. Installation
The given operating and performance features can only be guaranteed with the use of DITEC ac-
cessories and safety devices.
Unless otherwise specified, all measurements are expressed in mm.
4.1 Preliminary checks
Check that the structure is sufficiently rugged and that the hinge pivots are properly lubricated.
Provide an opening and closing stop.
Check the installation measurements
αA (mm)
120 130 140 150 160 170 180 190 200
B
(mm)
090° 90° 95° 95° 100° 100° 105° 105° 110°
50 90° 90° 95° 95° 95° 95° 95° 95° 95°
100 90° 90° 90° 90° 90° 90° 90° 90° /
150 90° 90° 90° 90° 90° 90° 90° / /
200 90°90°90°90°90°////
77 B
α
400 A
min
200

33
IP2132EN
4.2 Bracket fastening
- Securely fix the fastening plate [8] to the gate pillar and the arm retention bracket [13] to the
leaf as indicated in figure.
44 65
7611,5
Ø 8,5
43
31
400
Ø 8,5 100
160
A
13
8

34
IP2132EN
9
BOXFC1
LCU30H
8
4.3 Gearmotor installation
- Remove the lid [7] and fit the gearmotor [9] to the fastening plate [8] as indicated in figure.
- Release the gearmotor (see use instructions).
- Fix the articulated arms and the arm retention bracket [10] as indicated in figure.
-The arm articulations must be lubricated and the screws sufficiently tightened so that they do
not impede the movement of the arms.
-Adjust the open and closed position by means of limit screws [11] and [12].
12
11
10
(optional)
(integrated)
7

35
IP2132EN
4.4 Limit switch installation and adjustment (optional)
- Connect the limit switch wire fastons to the microswitches. Arrange the limit switch wires neatly
inside the microswitch box [1] and route the wire out through the appropriate opening.
- Fit the two cams [3] on to the cam ring without tightening the screws.
- Install the cam ring on the driving shaft and screw down screw [4] without tightening.
- Secure the microswitch box [1] to the geared motor.
- (Fig. 2-3) With gate closed, manually rotate the cam ring [2] so as to have the closing micros-
witch pressed down and the opening microswitch released. Firmly secure the cam ring in this
position by means of screw [4].
WARNING: check that between the geared motor and the limit switch cams there is a gap of at
least 1 mm.
- (Fig. 2-3) With gate open, check that the opening microswitch is pressed down.
NOTE: if the opening microswitch is not pressed down, move the cam on to hole [A].
- Upon setting being completed, tighten the cam screws.
- Connect limit switches as shown in fig. 2 (for motors opening clockwise) or in fig. 3 (for motors
opening anticlockwise).
A
2
4 3
1
CLOSING OPENING
32
31
33
31
33
CLOSING
SWITCH
OPENING
SWITCH
CLOSING
SWITCH
OPENING
SWITCH
32
CLOSING OPENING
OPENING
SWITCH
CLOSING
SWITCH
OPENING
SWITCH
CLOSING
SWITCH
33
31
32
33
31
32
Fig. 1
Fig. 2 Fig. 3

36
IP2132EN
36 35 34 33 32 31 +-LP - +LK 1520 0168
JR1
24 V~
C
O
M
UPDOWN
TRF
ENTER
ESC
BATTERY
CHARGER
(SBU)
BAT
F
U
S
E
F1
T
rasformatore
M2 M1
LN
Passo-passo
Apertura parziale
Antenna
Lampeggiante
Elettroserratura
SCHEDA AD INNESTO
AUX
-
+
Uscita 24 V
Arresto di sicurezza
Sicurezza in chiusura
24 V 24 V
Alimentazione
230 V~
50 / 60 Hz
BOXFC1
R
X
R
A
D
I
O
ZENRS
ZENPRS
5. Electrical connections
electronic panel LCU30H-HJ
To reverse the rotation direction reverse the polarity of the motor phases.
NOTE: the electrical wiring and the start-up of the gearmotors are shown in the control
panel installation manuals.
Before connecting the power supply, make sure that the data on the plate correspond to the elec-
tricity distribution network data. Provide an omnipolar switch/disconnector on the power network
with a contact opening distance of 3 mm or more. Check that there is a suitable residual-current
device and surge protector upstream of the electrical system. Use an H05RN-F 3G1.5 electrical
cable and connect it to terminals L (brown) and N (blue) inside the automation system. Connect
the earth cable (yellow/green) to the earth terminal.
Secure the cable by means of the cable clamp and only unsheathe it at the terminal.
Connections to the electrical distribution network and any other low-voltage conductors (230 V), in
the section outside the automation system, must be made with corrugated pipes that are independ-
ent and separate from the path of connections to the control and safety devices (SELV = Safety Extra
Low Voltage). Make sure there are no sharp edges that could damage the power cord.
ATTENTION: always observe L-N polarity when connecting to the mains.
Ensure that the mains connection cables, any other low-voltage cables (230 V), and safety
extra-low voltage safety accessory connection cables in the portion located inside the prod-
uct are kept well separated from the gear motor body.
PLUG-IN BOARD
Flashing light
Electric lock
Step-by-step
Partial opening
24V output
Safety stop
Transformer
Closing safety device
respect L-N
polarity
Power supply
230 V~
50/60 Hz
For the correct assembly of the limit switches, see the relative technical documentation BOXFC1 - IP1596:
https://www.ditecautomations.com/global/market-documents/QR/Multilanguages/ACCESSORIES/
GA/Ditec_BOXFC1_technical-manual_IP1596.pdf

37
IP2132EN
https://www.ditecautomations.com/global/market-documents/QR/Multilanguages/LCU30H/DitecLCU30H.pdf
For complete control panel instructions see manual LCU30H-HJ - IP2251:
For complete control panel instructions see manual LCU40H-HJ - IP2246:
https://www.ditecautomations.com/global/market-documents/QR/Multilanguages/LCU40H/DitecLCU40H.pdf

38
IP2132EN
NOTE: For spare parts, see the spares price list.
Only use original spare parts for repairing or replacing products.
The installer must supply all information concerning the automatic, manual and emergency
operation of the motorised door or gate, and must provide the user with the operating
instructions.
The installer must prepare and keep a maintenance record showing all the routine and
extraordinary maintenance work carried out.
6. Routine maintenance plan
Perform the following operations and checks every 6 months according to intensity of use of the
automation.
Without 230 V~ power supply and batteries if present:
- Clean and lubricate the gate’s rotation pins and hinges with neutral grease.
- Check the resistance of the fixing points.
- Check the electrical wiring is in good condition.
Reconnect the 230 V~ power supply and batteries if present:
- Check the power adjustment.
- Check that all commands and safety functions are operating correctly (photocells).
- Check that the release system is working correctly.
- Check that the batteries are working correctly (in continuity), by switching off the power supply
and performing several manoeuvres. Once performed, turn on the 230 V~ power supply again.

39
IP2132EN
Operating instructions
General safety precautions
for the user
ATTENTION! Important safety
instructions • Please follow these
instructions carefully • Failure to
observe the information given in
this manual may lead to severe
personal injury or damage to the
equipment • Keep these instruc-
tions for future reference.
WARNING! Disconnect power supply before any cleaning or mainte-
nance operation • This manual and those for any accessories can be
downloaded from www.ditecautomations.com
These precautions are an integral and essential part of the product and
must be supplied to the user. Read them carefully since they contain
important information on safe installation, use and maintenance. These
instructions must be kept and forwarded to all possible future users of
the system • This product must be used only for the specific purpose for
which it was designed. Any other use is to be considered improper and
therefore dangerous. The manufacturer cannot be held responsible for
any damage caused by improper, incorrect or unreasonable use • Avoid
operating in the proximity of the hinges or moving mechanical parts.
Do not enter within the operating range of the motorized door or gate
while it is moving. Do not obstruct the motion of the motorized door or
gate, as this may cause a dangerous situation • Lock and release the
door or gate wings only when the motor is switched off. Do not enter
within the action range of the door or gate wing(s) • In case of opera-
tion in “hold-to-run” (“dead man”)
mode, the corresponding command
devices must be located so to have
direct and complete view of the door
or gate during the maneuvers, away
from any moving parts, at a minimum
DETACH AND DELIVER TO THE CUSTOMER

40
IP2132EN
height of 1.5 m, and out of reach of the public • The motorized door
or gate may be used by children over the age of 8 and by people with
reduced physical, sensorial or mental abilities, or lack of experience
or knowledge, as long
as they are properly supervised or have been instructed in the safe use
of the device and the relative hazards • Children must be supervised
to make sure they do not play with the device, nor play or remain in the
area of action of the motorized door or gate. Keep remote controls and/
or any other command devices out of the reach of children, to avoid any
accidental activation of the motorized door or gate • Cleaning and main-
tenance work intended to be done by the end user must not be carried
out by children unless they are supervised. In the event of a product
fault or malfunction, turn off the power supply switch. Do not attempt
to repair or intervene directly.
Any repair or technical intervention must be carried out by qualified
personnel. Failure to comply with the above may cause a dangerous
situation • To ensure that the system works efficiently and correctly,
the manufacturer’s indications must be complied with and only quali-
fied personnel must perform routine maintenance on the motorized
door or gate. In particular, regular checks are recommended in
order to verify that the safety devices are operating correctly • All
installation,maintenance and repair work must be documented and
made available to the user.
DETACH AND DELIVER TO THE CUSTOMER

41
IP2132EN
For any problems and/or information, contact the Technical Service.
Manual release instructions
In the event of a fault or a power failure, introduce the key, turn it clockwise and fully open the
hatch. Manually open the gate.
To lock the gate again, close the hatch, turn the key anticlockwise and remove the key
NOTE: to turn off the automation the power supply and batteries (if present) must be disconnected.
WARNING: when the hatch is closed but the key is still horizontal, the release microswitch is open
and all manoeuvres are prevented.
WARNING: the door wing block and release operations must be performed with the
motor idle.
DETACH AND DELIVER TO THE CUSTOMER
1
2
3

IP2132EN
ASSA ABLOY Entrance Systems AB
Lodjursgatan 10
SE-261 44, Landskrona
Sweden
© ASSA ABLOY
All the rights concerning this material are the exclusive property of ASSA ABLOY Entrance Systems AB. Although
the contents of this publication have been drawn up with the greatest care, ASSA ABLOY Entrance Systems AB
cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication.
We reserve the right to make changes without prior notice.
Copying, scanning or changing in any way is expressly forbidden unless authorised in writing by ASSA ABLOY
Entrance Systems AB.
The crossed-out wheelie bin symbol indicates that the product should be disposed of separately from
normal household waste. The product should be recycled in accordance with local environmental regula-
tions for waste disposal. By separating a product marked with this symbol from household waste, you will
help reduce the volume of waste sent to incinerators or land-fill and minimise any potential negative impact on
human health and the environment.
This manual suits for next models
2
Table of contents
Other DITEC Gate Opener manuals

DITEC
DITEC DAB305 Manual

DITEC
DITEC CROSS18 User manual

DITEC
DITEC OBBI User manual

DITEC
DITEC PWR25H User manual

DITEC
DITEC TRAFFIC C User guide

DITEC
DITEC GLOBE IP1839 Manual

DITEC
DITEC ENTREMATIC SMART RESET User guide

DITEC
DITEC OBBI3BH User manual

DITEC
DITEC TRAFFIC C User guide

DITEC
DITEC CUBIC6 Manual
Popular Gate Opener manuals by other brands

Nice
Nice LFAB4000 Instructions and warnings for installation and use

CAME
CAME BX708RGS installation manual

CENTURION SYSTEMS
CENTURION SYSTEMS V Series Setup guide

GFA
GFA ELEKTROMAT KE 20.24-40,00 installation instructions

TMT Automation
TMT Automation CB236 manual

Roger Technology
Roger Technology B70/2ML quick start