European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com Tel: +44 (0)208 743 8880
www.e2s.com Fax: +44 (0)208 740 4200
Document No. D190-00-011-IS-SC Issue: 5 24-04-19 Sheet 1 of 7
INSTRUCTION & SERVICE MANUAL
D1xS1 & D1xS2 RADIAL ALARM HORNS
For Use In Hazardous Locations - Gas
1) Introduction
The D1xS1 & D1xS2 range are UL Classified alarm horns
which produce a loud warning signal in a hazardous area.
Sixty-Four first stage alarm sounds can be selected by internal
switches and each one can be externally changed to a second,
third or fourth stage alarm sound. The alarm horn may be used
for Gas applications in Class I Division 1 & 2 as well as Class
I Zone 1 & 2. The D1xS1 variants are also ATEx / IECEx
certified and can be used for gas applications in Zones 1 & 2.
D1xC1 & D1xC2 combined alarm horn & strobe units and
D1xL1 & D1xL2 Loudspeakers are also available as well as
variants for Explosive Dust Atmospheres.
2) Cautions and Warnings
CAUTION
TO REDUCE THE RISK OF IGNITION OF HAZARDOUS
ATMOSPHERES:
DISCONNECT FROM SUPPLY BEFORE OPENING.
KEEP TIGHTLY CLOSED WHEN IN OPERATION.
WARNING
FIT SEALING FITTING IN CONDUIT RUNS WITHIN 18
INCHES FROM ENCLOSURE.
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS
PRESENT
DO NOT OPEN WHEN ENERGISED
POTENTIAL ELECTROSTATIC CHARGING HAZARD -
CLEAN ONLY WITH A DAMP CLOTH
ATTENTION
POUR REDUIRE LE RISQUE D’INFLAMMATION DES
ATMOSPHÈRES DANGEREUSES:
COUPER L 'ALIMENTATION AVANT OUVERTURE.
CONSERVER FERMÉ PENDANT LE FONCIONNEMENT.
AVERTISSEMENT
CONDUITS DOIVENT ÊTRE SCELLÉS EN MOINS DE 18
POUCES.
NE PAS OUVRIR UN PRESENCE D’ATMOSPHERE
EXPLOSIVE
NE PAS OUVRIR ENERGIE
DANGER POTENTIEL CHARGE ÉLECTROSTATIQUE -
NETTOYER UNIQUEMENT AVEC UN CHIFFON HUMIDE
3) Ratings and Markings
The D1xS1 and D1xS2 Alarm Horns comply with the following
standards for hazardous locations:
UL 1203
CSA C22.2 NO. 30-M1986
The D1xS1 and D1xS2 Alarm Horns also comply with the
following standards for signaling equipment:
UL464
CSA C22.2 NO. 205-12
3.1 Class / Division Ratings for US & Canada
Class I Div 1 ABCD T6 Ta -40°C to +70°C
Installation must be carried out in compliance with the National
Electric Code / Canadian Electric Code
3.2 Class / Zone ratings US & Canada
Class I Zone 1 IIC T6 Ta -40°C to +70°C
Installation must be carried out in compliance with the National
Electric Code / Canadian Electric Code
3.3 Fire Alarm Rating
The following models are approved for use as audible signal
appliances for fire alarm use –public mode and produce a
sound pressure level above 75dB(A) at 10 feet:
D1xS1-DC024 / D1xS2-DC024
For public mode fire alarm use the temporal pattern tone No.
12 as per the tone table provided in these instructions must be
selected. For Fire Alarm use, units must be supplied 18-30Vdc.
3.4 Ambient Temperature Range:
D1xS1-DC024 / D1xS2-DC024 / D1xS2-AC230:
-40ºC to +70ºC
D1xS1-AC230:
-40ºC to +70ºC for 110-120Vac 50/60Hz
-40ºC to +55ºC for 120-240Vac 50/60Hz
3.5 Ingress Protection Ratings
The product is rated for ingress protection as follows:
IP rating per EN60529: IP66
Type rating per UL50E / NEMA250: 4 / 4X / 3R / 13
3.6 Electrical Ratings per UL Listing
Model No.
Nom.
Voltage
Nom. rms
current2
Voltage
Range
Max. rms
current3
D1xS1-DC024
24Vdc
217mA
10-30Vdc1
270mA @
18Vdc
D1xS1-AC230
115Vac 60Hz
230Vac 50Hz
77mA
53mA
110-240Vac
50/60Hz
82mA @
110Vac 60Hz
D1xS2-DC024
24Vdc
924mA
10-30Vdc1
1217mA @
18Vdc
D1xS2-AC230
115Vac 60Hz
230Vac 50Hz
268mA
159mA
110-240Vac
50/60Hz
293mA @
110Vac 60Hz
The D1xS1 & D1xS2 alarm horns are
classified by UL as Audible Signaling
Appliances for General Signaling and
Public Mode Fire Alarm use in Hazardous
Locations
__________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com Tel: +44 (0)208 743 8880
www.e2s.com Fax: +44 (0)208 740 4200
Document No. D190-00-011-IS-SC Issue: 5 24-04-19 Sheet 2 of 7
1) 18-30Vdc for Fire Alarm Use
2) Nom. rms current draw at nom. voltage and worst case tone
3) Max. rms current draw at worst case voltage and tone
3.7 Surge Current for Fire Alarm use per UL Listing
Part No.
Voltage
Peak Surge
Current
RMS surge
Current
D1xS1-DC024
30Vdc
8.36A @
1.44ms
966mA
D1xS2-DC024
30Vdc
9.92A @
1.02ms
1.09A
Surge current given at worst case voltage and tone
3.8 ATEX / IECEx certification
The D1xS1 Alarm Horns comply with the following standards
for hazardous locations:
EN60079-0:2018/ IEC60079-0: ed. 7.0 (2017)
EN60079-1:2014 / IEC60079-1: ed. 7.0 (2014-06)
The D1xS1 Alarm Horns are rated as follows:
Ex db IIC T5 Gb Ta -40°C to +75°C
Ex db IIC T6 Gb Ta -40°C to +70°C
Model No.: D1xS1
Input Voltage: DC Units 24V
AC Units 115V or 230V
Certificate No. DEMKO 19 ATEX 2141X
IECEx ULD 19.0008X
The units can be installed in locations with the following
conditions:
Area Classification Gas:
Zone 1
Explosive gas air mixture likely to occur in
normal operation.
Zone 2
Explosive gas air mixture not likely to occur
in normal operation, and if it does, it will
only exist for a short time.
Gas Groupings:
Group IIA
Propane
Group IIB
Ethylene
Group IIC
Hydrogen and Acetylene
Temperature Classification:
T1
450ºC
T2
300ºC
T3
200ºC
T4
135ºC
T5
100ºC
T6
85ºC
Equipment Category: 2G
Equipment Protection Level: Gb, Gc
Ambient Temperature Range: -40°C to +75°C
Installation must be carried out in compliance with the latest
issue of the following standards:
EN60079-14 / IEC60079-14: Explosive atmospheres -
Electrical installations design, selection and erection
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres -
Classification of areas. Explosive gas atmospheres
4) Installation
4.1 Safe Installation Requirements
The product must only be installed by suitably qualified
personnel in accordance with the latest issues of the relevant
standards.
The installation of the units must also be in accordance with
the NEC / CEC and any local regulations and should only be
carried out by a competent electrical engineer who has the
necessary training.
4.2 Specific Conditions of Use
To maintain the ingress protection rating and mode of
protection, the cable entries must be fitted with suitably rated
cable entry and/or blanking devices during installation. If
conduit is used for installation, seal conduit within 18 inches
from the enclosure.
If entries are fitted with adaptors they must be suitably rated for
the application. Fitting of blanking elements into adaptors is not
permitted.
If a high IP (Ingress Protection) rating is required then a
suitable sealing washer or O-ring must be fitted under any
cable gland or blanking device with metric threads.
Only the explosionproof cover is to be used for access to the
enclosure for installation, service and maintenance.
Connections are to be made into the terminal blocks using
solid or stranded wire, sizes 0.5-2.5mm2/ AWG 20-14. Wire
insulation needs to be stripped 6-7mm. Wires may be fitted
securely with crimped ferrules. Terminal screws need to be
tightened down with a tightening torque of 0.4 Nm / 3.5 Lb-in.
Earthing connections should be made to the Internal Earth
terminal in the explosionproof chamber or the external earth
stud.
Check that the ‘O’ ring seal is in place before replacing the
explosionproof cover.
If temperature exceeds 70°C at entry or 80°C at branching
point use suitable rated cable and cable glands:
Max. ambient temperature
75ºC
Req. Cable / Cable Gland
Rating: (D1xS1DC024 Only)
85ºC
0518
II 2G
Epsilon x
Equipment Group and
Category:
CE Marking
Notified Body No.
__________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com Tel: +44 (0)208 743 8880
www.e2s.com Fax: +44 (0)208 740 4200
Document No. D190-00-011-IS-SC Issue: 5 24-04-19 Sheet 3 of 7
External Earth
Assembly
4.3 Mounting
Fig. 1 Fixing locations.
The D1x Alarm Horn may be secured to any flat surface using
the three 7mm fixing holes. The enclosure provides IP66
protection and is suitable for installation in exterior locations
providing the cable entry is sealed.
4.4 Installation procedure
a. Secure the D1x alarm horn to a flat surface via the three
7mm fixing holes in the mounting bracket.
b. Remove the explosionproof cover of the alarm horn by
unscrewing it, taking care not to damage the
explosionproof threads in the process (Refer to section
5).
c. Fit an M20/NPT suitably rated cable gland or conduit
entry into the hole in the enclosure and connect the field
wiring to the appropriate alarm horn terminals as shown
in fig. 6 (AC) or fig 8. (DC). The power supply terminals
are duplicated so that units may be connected in
parallel. An end of line monitoring resistor may be fitted
to DC units only (see section 12). If the second and
third M20/NPT entries are not used, suitably rated
stopping plugs must always be fitted.
d. Replace the explosionproof cover of the loudspeaker,
taking care not to damage the explosionproof threads.
Tighten fully.
4.5 Hornless Variants
The D1x Sounder is also available as a variant with no horn
fitted in the factory. The Horn threaded nose portion has a
fitment thread of 1-3/8” – 18 UNF (to BS1580 or ANSI B1.1).
The customer is responsible for sourcing and correctly fitting a
suitable horn that meets all of the relevant safety
requirements.
5) Access to the Explosionproof Enclosure
In order to connect the electrical supply cables to the alarm
horn it is necessary to remove the explosionproof cover to gain
access to the explosionproof chamber. This can be achieved
by unscrewing the explosionproof cover (counter-clockwise),
taking extreme care not to damage the explosionproof threads
in the process.
Fig. 2 Accessing the
Explosionproof Enclosure.
On completion of the cable wiring installation the
explosionproof threads should be inspected to ensure that they
are clean and that they have not been damaged during
installation. Also check that the ‘O’ ring seal is in place, on the
thread diameter in contact with the flat face of the
explosionproof cover. When replacing the explosionproof cover
ensure that it is tightened fully.
6) Volume Control
The output level of the D1x alarm horn can be set by adjusting
the volume control potentiometer (see Fig 3). For maximum
output, set the potentiometer fully clockwise.
D1xS2AC / D1xS2DC / D1xS1DC / D1xS1AC
Fig. 3 Location of field controls
7) Tone Selection
The D1xS1 & D1xS2 units have 64 different tones that can be
selected independently for the first and second stage alarms.
The tones are selected by operation of the tone setting DIP
switches 1 & 2 (see Fig. 3) on the PCB. The alarm horns can
also be switched to sound the third and fourth stage alarm
tones. The tone table (Table 1) shows the switch positions for
the 64 tones on first and second stages and which tones are
available for the third and fourth stages dependent on the
Stage 1 DIP switch setting.
8) Stage Switching Polarity (DC Units Only)
The D1xS2 and D1xS1 DC alarm horns have the facility to use
either +ve or –ve switching to change the tone to the second,
third and fourth stages. For –ve switching connect the two
headers on the pcb to the left-hand (marked –ve) and centre
pins. For +ve switching connect the headers to the right hand
(marked +ve) and the centre pins. (Refer to Fig. 4)
Fig. 4 Stage Switching Polarity
Flameproof
cover
Stopping plug
(Appropriate
cable glands to
be customer
supplied)
Positive
Switching
Activated
Negative
Switching
Activated
Volume Control
Potentiometer
Stage 2
Stage 1
Tone
Selection
Dip
Switches
External Earth
Internal
Earth
Volume Control
Potentiometer
External Earth
__________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com Tel: +44 (0)208 743 8880
www.e2s.com Fax: +44 (0)208 740 4200
Document No. D190-00-011-IS-SC Issue: 5 24-04-19 Sheet 4 of 7
9) AC Wiring
9.1 Wiring Diagrams
Fig 5a. D1xS1AC Simplified Block Diagram
Fig 5b. D1xS2AC Simplified Block Diagram
9.2 Units First Stage Tones
Stage one (S1) operation: Simply connect the supply voltage to
the L and N supply terminals, (see fig. 6).
9.3 AC Units Second, Third and Fourth Stage Tone
Selection
To select the second, third and fourth stage tones on the D1x
AC alarm horns.
Stage two (S2) operation: Power L and N, link the Common-C
(D1xS2) or the Live-L (D1xS1) and S2 terminal.
Stage three (S3) operation: Power L and N, link the Common-
C (D1xS2) or the Live-L (D1xS1) and S3 terminals.
Stage four (S4) operation: Power L and N, link the Common-C
(D1xS2) or the Live-L (D1xS1) and both the S2 and S3
terminals.
D1xS1AC Terminals D1xS2AC Terminals
Fig. 6 AC Terminals
10) DC Wiring
10.1 Wiring Diagrams
Fig. 7a DC Simplified Block Diagram (negative
switching)
Fig. 7b DC Simplified Block Diagram (positive
switching
10.2 Units First Stage Tones
Stage one (S1) operation: Simply connect the supply voltage to
the + and - supply terminals, (see fig. 8).
10.3 DC Units Second, Third and Fourth Stage Tone
Selection
For units set up for –ve switching (default setting):
Stage two (S2) operation: Power +ve and –ve, link a -ve supply
line to the S2 terminal. Dip switch 2 alters stage 2 tone.
Stage three (S3) operation: Power +ve and –ve, link a -ve
supply line to the S3 terminal. Dip switch 1 alters stage 3 tone.
Stage four (S4) operation: Power +ve and –ve, link a -ve
supply line to both the S2 & S3 terminals. Dip switch 1 alters
stage 4 tone.
For units set up for +ve switching (refer to 9.1):
Stage two (S2) operation: Power +ve and –ve, link a +ve
supply line to the S2 terminal. Dip switch 2 alters stage 2 tone.
Stage three (S3) operation: Power +ve and –ve, link a +ve
supply line to the S3 terminal. Dip switch 1 alters stage 3 tone.
Stage four (S4) operation: Power +ve and –ve, link a +ve
supply line to both the S2 & S3 terminals. Dip switch 1 alters
stage 4 tone.
Fig. 8 DC Terminals
STAGE 4 = S2 + S3
(Customer Supplied switches)
L L N N E E S2 S3
L L N N E C S2 S3
STAGE 4 = S2 + S3
(Customer Supplied switches)
STAGE 4 = S2 + S3
(Customer Supplied switches)
STAGE 4 = S2 + S3
(Customer Supplied switches)
+ + - - S2 S3
__________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH [email protected] Tel: +44 (0)208 743 8880
www.e2s.com Fax: +44 (0)208 740 4200
Document No. D190-00-011-IS-SC Issue: 5 24-04-19 Sheet 5 of 7
11) Earthing
The unit has both a primary internal and secondary external
earth fixing point.
Internal earth connections should be made to the internal Earth
terminal (see Fig. 3 and 4. It should be fitted to the internal
earth point using a ring crimp terminal to secure the earth
conductor.
In addition, external earth connections can be made to the M5
earth stud (see Fig. 2), using a ring crimp terminal to secure
the earth conductor to the earth stud. The external earth crimp
ring should be located between the two M5 plain washers
provided and securely locked down with the M5 spring washer
and M5 nut.
The earth conductor should be at least equal in size and rating
to the incoming power conductors but at least a minimum of
0.82mm2/ 18AWG in size.
12) End Of Line Monitoring (DC Units Only)
On D1xS1DC & D1xS2DC units, dc reverse line monitoring can
be used if required. All DC alarm horns have a blocking diode
fitted in their supply input lines. An end of line monitoring diode
or an end of line monitoring resistor can be connected across
the +ve and –ve terminals. If an end of line resistor is used it
must have a minimum resistance value of 3k3 ohms and a
minimum power rating of 0.5 watts or a minimum resistance
value of 500 ohms and a minimum power rating of 2 watts.
The resistor must be connected directly across the +ve and -ve
terminals as shown in the following drawing. The resistor leads
should be kept as short as possible.
Fig. 9 End Of Line Resistor Placement
13) Maintenance, Repair and Overhaul
Maintenance, repair and overhaul of the equipment should only
be carried out by suitably qualified personnel in accordance
with the current relevant standards and regulations.
Units must not be opened while an explosive atmosphere is
present.
If opening the unit during maintenance operations a clean
environment must be maintained and any dust layer removed
prior to opening the unit.
The threaded flamepath joints are not intended to be repaired.
End of Line Resistor
__________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com Tel: +44 (0)208 743 8880
www.e2s.com Fax: +44 (0)208 740 4200
Document No. D190-00-011-IS-SC Issue: 5 24-04-19 Sheet 6 of 7
1600Hz
1400Hz 1s
0.5s
Tone Selection –To select the required first stage tone set the tone Set DIP switch 1 (6 way DIP see Fig 3) to the required tone setting shown in the table below. The
table also shows the second stage tone can be set independently with the Stage 2 DIP switch to select the required tone. The 3rd and 4th stage tones are available if more
than two tone output stages are required, they are set/linked via the first stage tone selection.
Stage 1
Set DIP
Switch 1
Tone No
Tone Description
Tone Visual
Stage 1 & 2 DIP
Switch Settings
1 2 3 4 5 6
Stage 2
Set DIP
Switch 2
Tone (S2)
Stage 3
Set DIP
Switch 1
Tone (S3)
Stage 4
Set DIP
Switch 1
Tone
(S2 + S3)
1
1000Hz PFEER Toxic Gas
0 0 0 0 0 0
1
2
44
2
1200/500Hz @ 1Hz DIN /
PFEER P.T.A.P.
1 0 0 0 0 0
2
3
44
3
1000Hz @ 0.5Hz(1s on, 1s
off) PFEER Gen. Alarm
0 1 0 0 0 0
3
2
44
4
1.4KHz-1.6KHz 1s, 1.6KHz-
1.4KHz 0.5s NF C 48-265
1 1 0 0 0 0
4
24
1
5
544Hz(100mS)/440Hz
(400mS) NF S 32-001
0 0 1 0 0 0
5
19
1
6
1500/500Hz - (0.5s on , 0.5s
off) x3 + 1s gap AS4428
1 0 1 0 0 0
6
44
1
7
500-1500Hz Sweeping 2
sec on 1 sec off AS4428
0 1 1 0 0 0
7
44
1
8
500/1200Hz @ 0.26Hz(3.3s
on, 0.5s off) Netherlands -
NEN 2575
1 1 1 0 0 0
8
24
35
9
1000Hz (1s on, 1s off)x7 +
(7s on, 1s off) IMO Code 1a
0 0 0 1 0 0
9
34
1
10
1000Hz (1s on, 1s off)x7 +
(7s on, 1s off) IMO Code 1a
1 0 0 1 0 0
10
34
1
11
420Hz(0.5s on, 0.5s off)x3 +
1s gap ISO 8201 Temporal
Pattern
0 1 0 1 0 0
11
1
8
12
1000Hz(0.5s on, 0.5s off)x3
+ 1s gap ISO 8201
Temporal Pattern
1 1 0 1 0 0
12
1
8
13
422/775Hz - (0.85 on, 0.5
off) x3 + 1s gap NFPA -
Temporal Coded
0 0 1 1 0 0
13
1
8
14
1000/2000Hz @ 1Hz
Singapore
1 0 1 1 0 0
14
3
35
15
300Hz Continuous
0 1 1 1 0 0
15
24
35
16
440Hz Continuous
1 1 1 1 0 0
16
24
35
17
470Hz Continuous
0 0 0 0 1 0
17
24
35
18
500Hz Continuous IMO
code 2 (Low)
1 0 0 0 1 0
18
24
35
19
554Hz Continuous
0 1 0 0 1 0
19
24
35
20
660Hz Continuous
1 1 0 0 1 0
20
24
35
21
800Hz IMO code 2 (High)
0 0 1 0 1 0
21
24
35
22
1200Hz Continuous
1 0 1 0 1 0
22
24
35
23
2000Hz Continuous
0 1 1 0 1 0
23
3
35
24
2400Hz Continuous
1 1 1 0 1 0
24
20
35
25
440 @0.83Hz (50
cycles/minute) Intermittent
0 0 0 1 1 0
25
44
8
26
470 @0.9Hz - 1.1s
Intermittent
1 0 0 1 1 0
26
44
8
27
470Hz @5Hz - (5
cycles/second) Intermittent
0 1 0 1 1 0
27
44
8
28
544Hz @ 1.14Hz - 0.875s
Intermittent
1 1 0 1 1 0
28
24
8
29
655Hz @ 0.875Hz
Intermittent
0 0 1 1 1 0
29
44
8
30
660Hz @0.28Hz - 1.8sec
on, 1.8sec off Intermittent
1 0 1 1 1 0
30
24
8
31
660Hz @3.34Hz - 150mS
on, 150mS off Intermittent
0 1 1 1 1 0
31
24
8
1000Hz
1000Hz 1s
1s
544Hz
440Hz
0.1s
0.4s
1500Hz
500Hz 0.5s 0.5s 1.5s
0.5s 0.5s 0.5s
1500Hz
500Hz 2s 1s
1200Hz
500Hz 3.3s 0.5s
1s 1s 1s 7s
7s
1s 1s 1s 1s 1s 1s 1s
1000Hz 1s 1s 1s 1s
0.5s
0.5s
0.5s
1.5s
420Hz 0.5s
0.5s
1000Hz 0.5s
0.5s
0.5s
0.5s
0.5s
1.5s
775Hz
422Hz 0.85s 0.5s 0.85s 0.5s 0.85s 1.5s
2000Hz
1000Hz 1s
300Hz
440Hz
470Hz
500Hz
554Hz
660Hz
800Hz
1200Hz
2000Hz
2400Hz
440Hz 0.6s
0.6s
470Hz 0.55s
0.55s
470Hz 0.1s
0.1s
470Hz 0.43s
0.44s
655Hz 0.57s
0.57s
660Hz 1.8s
1.8s
660Hz 0.15s
0.15s
500Hz
1s
1200Hz
__________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH [email protected] Tel: +44 (0)208 743 8880
www.e2s.com Fax: +44 (0)208 740 4200
Document No. D190-00-011-IS-SC Issue: 5 24-04-19 Sheet 7 of 7
32
745Hz @ 1Hz Intermittent
1 1 1 1 1 0
32
24
8
33
800Hz - 0.25sec on, 1 sec
off Intermittent
0 0 0 0 0 1
33
24
8
34
800Hz @ 2Hz IMO code 3.a
(High) Intermittent
1 0 0 0 0 1
34
24
8
35
1000Hz @ 1Hz Intermittent
0 1 0 0 0 1
35
24
8
36
2400Hz @ 1Hz Intermittent
1 1 0 0 0 1
36
24
8
37
2900Hz @ 5Hz Intermittent
0 0 1 0 0 1
37
24
8
38
363/518Hz @ 1Hz
Alternating
1 0 1 0 0 1
38
8
19
39
450/500Hz @ 2Hz
Alternating
0 1 1 0 0 1
39
8
19
40
554/440Hz @ 1Hz
Alternating
1 1 1 0 0 1
40
24
19
41
554/440Hz @ 0.625Hz
Alternating
0 0 0 1 0 1
41
8
19
42
561/760Hz @0.83Hz (50
cycles/minute) Alternating
1 0 0 1 0 1
42
8
19
43
780/600Hz @ 0.96Hz
Alternating
0 1 0 1 0 1
43
8
19
44
800/1000Hz @ 2Hz
Alternating
1 1 0 1 0 1
44
24
19
45
970/800Hz @ 2Hz
Alternating
0 0 1 1 0 1
45
8
19
46
800/1000Hz @ 0.875Hz
Alternating
1 0 1 1 0 1
46
24
19
47
2400/2900Hz @ 2Hz
Alternating
0 1 1 1 0 1
47
24
19
48
500/1200Hz @ 0.3Hz
Sweeping
1 1 1 1 0 1
48
24
12
49
560/1055Hz @ 0.18Hz
Sweeping
0 0 0 0 1 1
49
24
12
50
560/1055Hz @ 3.3Hz
Sweeping
1 0 0 0 1 1
50
24
12
51
600/1250Hz @ 0.125Hz
Sweeping
0 1 0 0 1 1
51
24
12
52
660/1200Hz @ 1Hz
Sweeping
1 1 0 0 1 1
52
24
12
53
800/1000Hz @ 1Hz
Sweeping
0 0 1 0 1 1
53
24
12
54
800/1000Hz @ 7Hz
Sweeping
1 0 1 0 1 1
54
24
12
55
800/1000Hz @ 50Hz
Sweeping
0 1 1 0 1 1
55
24
12
56
2400/2900Hz @ 7Hz
Sweeping
1 1 1 0 1 1
56
24
12
57
2400/2900Hz @ 1Hz
Sweeping
0 0 0 1 1 1
57
24
12
58
2400/2900Hz @ 50Hz
Sweeping
1 0 0 1 1 1
58
24
12
59
2500/3000Hz @ 2Hz
Sweeping
0 1 0 1 1 1
59
24
12
60
2500/3000Hz @ 7.7Hz
Sweeping
1 1 0 1 1 1
60
24
12
61
800Hz Motor Siren
0 0 1 1 1 1
61
24
12
62
1200Hz Motor Siren
1 0 1 1 1 1
62
24
12
63
2400Hz Motor Siren
0 1 1 1 1 1
63
24
12
64
Simulated Bell
1 1 1 1 1 1
64
21
12
745Hz 0.5s
0.5s
800Hz 0.25s
1s
800Hz 0.25s
0.25s
1000Hz 0.5s
0.5s
2400Hz 0.5s
0.5s
2900Hz 0.1s
0.1s
1250Hz
600Hz 8s
1450Hz 0.25s
0.69ms
1200Hz
500Hz 3.34s
1055Hz
560Hz 5.47s
1055Hz
560Hz 0.3s
1200Hz
660Hz 1s
1000Hz
800Hz 1s
1000Hz
800Hz 0.14s
1000Hz
800Hz 0.02s
2900Hz
2400Hz 0.14s
2900Hz
2400Hz 1s
2900Hz
2400Hz 0.02s
3000Hz
2500Hz 0.5s
3000Hz
2500Hz 0.13s
800Hz
1.6s
1200Hz
2s
2400Hz
1.7s
363Hz
518Hz 0.5s 0.5s
500Hz 0.25s 0.25s
450Hz
554Hz 0.5s 0.5s
440Hz
554Hz 0.8s 0.8s
440Hz
760Hz 0.6s 0.6s
561Hz
780Hz 0.52s 0.52s
600Hz
1000Hz 0.25s 0.25s
800Hz
970Hz 0.25s 0.25s
800Hz
2900Hz 0.25s 0.25s
2400Hz
1000Hz 0.57s 0.57s
800Hz

Other manuals for D1xS1 Series

1

This manual suits for next models

5

Other E2S Security System manuals

E2S D105AX User manual

E2S

E2S D105AX User manual

E2S D1 B2LD2 Series User manual

E2S

E2S D1 B2LD2 Series User manual

E2S D1xC2 Series User manual

E2S

E2S D1xC2 Series User manual

E2S GNExCP6B-PT User manual

E2S

E2S GNExCP6B-PT User manual

E2S GNExB2X05 Series User manual

E2S

E2S GNExB2X05 Series User manual

E2S D1xS2 Series User manual

E2S

E2S D1xS2 Series User manual

E2S BExCBL2-L2D-P User manual

E2S

E2S BExCBL2-L2D-P User manual

E2S BExS120D User manual

E2S

E2S BExS120D User manual

E2S SPECTRA H100 B User manual

E2S

E2S SPECTRA H100 B User manual

E2S D2xC2LD2 Series User manual

E2S

E2S D2xC2LD2 Series User manual

E2S BExBG21D-P User manual

E2S

E2S BExBG21D-P User manual

E2S STExB2LD2 User manual

E2S

E2S STExB2LD2 User manual

E2S HA121 User manual

E2S

E2S HA121 User manual

E2S WP6-BG User manual

E2S

E2S WP6-BG User manual

E2S GNExCP6B-PB User manual

E2S

E2S GNExCP6B-PB User manual

E2S AlertAlight DL105X User manual

E2S

E2S AlertAlight DL105X User manual

E2S D2xB1X05 Series User manual

E2S

E2S D2xB1X05 Series User manual

E2S D2xB1XH1 User manual

E2S

E2S D2xB1XH1 User manual

E2S STExCP8-BG-D User manual

E2S

E2S STExCP8-BG-D User manual

E2S BExBG10D-P User manual

E2S

E2S BExBG10D-P User manual

E2S SONFL1H-HO Series User manual

E2S

E2S SONFL1H-HO Series User manual

E2S D1xC3 User manual

E2S

E2S D1xC3 User manual

E2S GNExCP7-BG-S User manual

E2S

E2S GNExCP7-BG-S User manual

E2S D1 B2X05 Series User manual

E2S

E2S D1 B2X05 Series User manual

Popular Security System manuals by other brands

Ei Electronics Ei600 Series instruction manual

Ei Electronics

Ei Electronics Ei600 Series instruction manual

Integra BCR-S Mini G2 installation manual

Integra

Integra BCR-S Mini G2 installation manual

STL VIBE S-VLF instruction manual

STL

STL VIBE S-VLF instruction manual

AKO 52041 instructions

AKO

AKO 52041 instructions

Vimar BY-ALARM PLUS Installer manual

Vimar

Vimar BY-ALARM PLUS Installer manual

Sharp YL-SU100M Operation manual

Sharp

Sharp YL-SU100M Operation manual

Intermatic SP440B supplementary guide

Intermatic

Intermatic SP440B supplementary guide

Assa Abloy Yale Smart Living SR-1100 manual

Assa Abloy

Assa Abloy Yale Smart Living SR-1100 manual

Zeta Alarm Systems Prem1er Quatro installation manual

Zeta Alarm Systems

Zeta Alarm Systems Prem1er Quatro installation manual

dallmeier PANOMERA W8 Commissioning

dallmeier

dallmeier PANOMERA W8 Commissioning

Radionics D7212 Installation and troubleshooting quick reference

Radionics

Radionics D7212 Installation and troubleshooting quick reference

Siemens PCA2005-A1 Technical manual

Siemens

Siemens PCA2005-A1 Technical manual

Vesta BOGP-3-G2 user manual

Vesta

Vesta BOGP-3-G2 user manual

Tyco DSC PG9938 installation instructions

Tyco

Tyco DSC PG9938 installation instructions

Honeywell Friedland GlobalGuard operating manual

Honeywell

Honeywell Friedland GlobalGuard operating manual

ADE Optima user manual

ADE

ADE Optima user manual

Safety Angel Water Immersion Alarm manual

Safety Angel

Safety Angel Water Immersion Alarm manual

Ritron QuickTalk RQT-150 owner's manual

Ritron

Ritron QuickTalk RQT-150 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.