emaux FSF350-6W User manual

INSTALLATION
WARNING
By-passes filter for circulating water to pool
Used after backwash to flush dirt from valve
Cleaning Filter by reversing the flow
By-passes filter, used for vacuuming to waste or lowering water level
CLOSED Shuts off all flow to filter or pool
RECIRCULATE
WASTE
RINSE
BACKWASH
FILTER
Valve Position
Normal Filtration and Vacuuming
Function
VALVE REPLACEMENT PARTS
FILTER & PUMP COMBO
Installation & Operating Instruction
FSF350-6W / FSF400-6W / FSF450-6W
FSF500-6W / FSF650-6W
1-4
4-4
17 18 19 20 21
13
14
15
16
6
12
1
2
3
4
5
7
8
9
10
11
17
18
19
22
21
23
24
25
26
* Install filtration system including pump,filter tank and multiport valve.
* The filter system should be installed as close as possibie to the swimming pool and preferably at a
level of 0.50 metres below the surface of the water in the swimming pool. Make sure there is
drainage available at the place where the filter is to be installed.
* PUMP
1) Only qualified,licensed personnel should install pump and wiring.
2) Electrical Contractors Please Note:All 220 volt 50Hz pump must be wired to the main power supply
trough an approved and correctly rated contractor.
3) Allow for gate valve in suction piping.
4) Pump suction and discharge connections have moulded in thread stops,do not try to screw pipe in
beyond these stops.
* FILTER TANK and MULTIPORT VALVE
1) Loading the sand media.Filter sand media is loaded through the top opening of the filter.
a) Loosen the plastic clamps from tank neck.
b) Cap internal pipe with plastic cap to prevent sand from entering it.
c) We recommend filling tank approximately 1/2 way with water to provide a cushion effect when the
filter sand is poured in. This helps protect the under-drain laterals from excessive shock.
d) Carefully pour in correct amount and grade of filter sand.Be sure center pipe remains centered in
opening. Sand surface should be leveled and should come to about the middle of the filter
tank.Remove plastic cap from internal pipe.
2) Assemble filter control valve to filter tank.
a) Insert filter control valve(with O'ring in place)into the tank neck,taking care that the center pipe slips
into the hole in the bottom of the valve.
b) Place two plastic clamps around valve flange and tank neck and tighten just enough so that the valve
mayBe rotated on tank for final positioning.
c) Carefully screw pressure gauge(with O'ring in place)into tapped hole in valve body.Do not over-
tighten.
d) Connect pump to control valve opening marked PUMP with hose.After connections are
made,tighten clamps with screwdrive,tapping around clamp with screwdrive handle to help seat
valve flange clamp.
3) Make return to pool pipe connection to control valve opening marked RETURN and complete other
necessary plumbing connections,suction lines to pump,waste,etc.
4) To prevent water leakage,be sure all pipe connections are tight.
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM
(e.g., CLAMP, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND
BECOME PRESSURIZED . PRESSURIZED AIR CAN CAUSE THE LID OR VALVE TO BE BLOWN OFF
WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE.
TURN PUMP OFF BEFORE CHANGING VALVE POSITION.
TO PREVENT DAMAGE TO THE PUMP AND FOR PROPER OPERATION OF THE SYSTEM.CLEAN
PUMP STRAINER AND SKIMMER BASKETS REGULARLY.
DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE PUMP IS RUNNING.
!
!
!
!
Item
Part No.
Descrip tion
Qty
1
0101300 3
Handle(B ig)
1
2
0301800 8
Pin for Han dle
1
3
0118100 1
Washer fo r Handle
1
4
8928010 7
M6×30 Scr ew with Nut for Stan dard Lid
6
5
0101300 4
1.5"Top Mount Valv e Standard Lid (Black)
1
6
0201100 2
O-Ring for 1.5" Va lve Lid
1
7
0118100 2
Washer fo r Spring
1
8
0301400 1
Spring fo r 1.5" Top Mount Valve
1
9
0201102 2
O-Ring for 1.5" Va lve Rotor
2
10
0102100 1
1.5" Valve Rot or
1
11
0231100 2
Spider Ga sket
1
12
0101300 7
1.5"Top Mount Valv e Bottom Body Clam p(black)
1
13
0101301 1
1.5" Diffuse r
1
14
0201100 1
O-Ring for Di ffuser
1
15
0101301 2
1.5"Top Mount Valv e Over Drain Diffu ser
1
16
0201113 4
O-Ring
1
17
0202001 3
O-Ring for 1.5"Co nnector
3
18
0101301 5
1.5"Connect or (black)
3
19
0201100 3
O-Ring for 1.5"Un ion
3
20
0117115 3
1.5"Union (A/E)
2
21
0101301 7
1.5"Union Nut ( black)
3
22
0104100 2
1.5"Union Wit h Sight Glass (short)
1
23
0117202 6
1.5"Union Wit h Sight Glass Hold er
1
24
0111104 8
Connect or for pressure gauge/st opper
1
0201113 9
O-ring
1
25
8902170 3
Drain Plu g with O-ring
1
26
0601102 9
Oil Press ure Gauge With O-rin g (40Psi)
1
EMFS16031401

Parts of FSF350-6W
INSTALL/START-UP OF FILTRATION
2-4
3-4
PRIMING PUMP
1 Be sure correct amount of filter media sand is in tank and that all connections have been made and are secure.
2 Depress control valve handle and rotate to BACKWASH position. (To prevent damage to control valve seal,
always depress handle before turning.)
3 Prime and start pump. Never tun pump dry! Running pump dry may damage seals,causing leakage and
flooding! Fill pump with water before starting motor. (be sure all suction and return lines are open), allowing the
filter tank to fill with water. Once water is flowing out of the waste line, run the pump for at least 1 minute. The initial
back-washing of the filter is recommended to remove any impurities or fine sand particles in the sand media.
4 Turn pump off and set valve to RINSE position. Start pump and operate until water in sight glass is clear, about 1/2 to
1 minute. Turn pump off and set valve to FILTER position and restart pump.The filter is now operating in the normal
filter mode, filtering dirt particles from the pool water.
5 Adjust pool suction and return valves to achieve desired flow. Check system and filter for water leaks and tighten
connections, bolts, nuts, as required.
6 Note the initial pressure gauge reading when the filter is clean. (It will vary from pool to pool depending upon the
pump and general piping system.) As the filter removes dirt and impurities from the pool water, the
accumulation in the filter will cause the pressure to rise and flow to diminish. When the pressure gauge reading is
1.5 bar, higher than the initial "clean" pressure you noted, it is time to backwash the filter (see BACKWASH under
filter and control valve functions).
NOTE: During initial clean-up of the pool water it may be necessary to backwash frequently due to the unusually
heavy initial dirt load in the water.
)
)
)
)
)
)
Release all air from filter and piping system.
In a flooded suction system (water source higher than pump), pump will prime itself when suction and
discharge valves are opened.
If pump is not in a flooded suction system, unscrew and remove trap cover; fill trap and pump with water.
Clean and inspect Ring; re-install on trap cover.
Replace trap cover on trap; turn clockwise to tighten cover.
NOTICE: Tighten trap cover by hand only .Pump should prime now. Priming time will depend on vertical
length of suction lift and horizontal length of suction piping.
Key No.
Part No.
Description
QTY
1*
88280105
1.5" Top Mount Valve (Black/ White colour)
1
2*
89280101
1.5" Unionwith Sight Glass and O-Ring (Black/ White colour)
1
3
06011029
Maximum 40PSI Indication, Stainless Steel Casing
1
3
01111048
Connector for Pressure Gauge/Stopper
1
4*
89280102
1.5" Union Set with O-Ring (Black/ White colour)
1
5
89030204
Hose Adaptor with O-Ring
1
6
02011026
Sleeve for Hose
2
7
89032002
FSF350-6W Plastic Hose with Nut
1
8
01013049
Hose Adaptor with Nut
1
9
02011104
O-Ring for 1.5" Union
1
10
88022402
FSF350-6W Pump (SS033)
1
11
89032001
Pump Assembly Screw
2
12
01111056
FSP/F350-4-6W Combo Base
1
13
89010107
Water Drain Set
1
14
89010106
V350 Lateral Assembly with Center Pipe
1
15
89010115
V350 Filter tank
1
16
02011134
O-Ring for Filter Neck
1
17
01271010
Clamp Lock
2
18
01181052
Fastener for Filter base
4
19
89010119
M6*50 Screws With Nut
2
Parts of FSF400-6W / FSF450-6W / FSF500-6W / FSF-650-6W
Notes: 1* 88280105B is 1.5" Top Mount Valve in Black colour
1* 88280105W is 1.5" Top Mount Valve in White colour
2* 89280101B is 1.5" Union with Sight Glass and O-Ring in Black colour
2* 89280101W is 1.5" Union with Sight Glass and O-Ring in White colour
4* 89280102B is 1.5" Union Set with O-Ring in Black colour
4* 89280102W is 1.5" Union Set with O-Ring in White colour
KeyNo.
Part No.
Description
QTY
1*
88280105
1.5" Top Mount Valve (Black/ White Colour)
1
2*
89280101
1.5" Union with Sight Glass and O-Ring (Black/ White Colour)
1
3
01111048
Connector for Pressure Gauge/Stopper
1
4*
89280102
1.5" Union Set with O-Ring (Black/ White Colour)
1
5
89032102
1.5" Bulkhaed Fitting with O-Ring
1
6
06011029
Maximum 40PSI Indication, Stainless Steel Casing
1
7
89032103
FSF400-6W Plastic Hose with Nut
1
7
89032201
FSF450-6W Plastic Hose with Nut
1
7
89032301
FSF500-6W Plastic Hose with Nut
1
7
89032401
FSF650-6W Plastic Hose with Nut
1
8
02011104
O-Ring for 1.5" Union
1
9
88022403
Pump 0.50hp, 220V/50Hz, Single Phase
1
9
88022404
Pump 0.75hp, 220V/50Hz, Single Phase
1
9
88021705
Pump 1.00hp, 220V/50Hz, Single Phase
1
9
88021707
Pump 1.50hp, 220V/50Hz, Single Phase
1
10
89032001
Pump Assembly Screw
2
11
01181052
Fastener for Filter Base
4
12
89010107
Water Drain Set
1
13
01111053
FSP/F400-6W - FSP/F650-6W Combo Base
1
14
01172007
Laterals(115mm)
8
14
01172008
Laterals (126mm)
8
15
89010116
V400 Lateral Assembly with Center Pipe
1
15
89010105
V450 Lateral Assembly with Center Pipe
1
15
89010104
V500 Lateral Assembly with Center Pipe
1
15
89010103
V650 Lateral Assembly with Center Pipe
1
16
89010113
V400 Filter tank
1
16
89010112
V450Filter Tank
1
16
89010111
V500 Filter tank
1
16
89010110
V650 Filter tank
1
17
02011134
O-Ring for Filter Neck
1
18
01271010
Clamp Lock
2
19
89010119
M6*50 Screws With Nut
2
Notes: 1* 88280105B is 1.5" Top Mount Valve in Black Colour
1* 88280105W is 1.5" Top Mount Valve in White Colour
2* 89280101B is 1.5" Union with Sight Glass and O-Ring in Black Colour
2* 89280101W is 1.5" Union with Sight Glass and O-Ring in White Colour
4* 88280102B is 1.5" Union Set wirh O-ring in Black Colour
4* 88280102W is 1.5" Union Set wirh O-ring in White Colour
This manual suits for next models
4
Other emaux Lighting Equipment manuals

emaux
emaux SP500 User manual

emaux
emaux S700B User manual

emaux
emaux LED-P100 series Manual

emaux
emaux V900 User manual

emaux
emaux FOS-UV-5T User manual

emaux
emaux S700R User manual

emaux
emaux CE306A User manual

emaux
emaux S900 User manual

emaux
emaux FSP350-4W User manual

emaux
emaux E-Lumen X Series User manual
Popular Lighting Equipment manuals by other brands

Commercial Electric
Commercial Electric 56574141 Use and care guide

American DJ
American DJ TRI PHASE User instruction

Oypla
Oypla HOME 3395 user manual

thomann
thomann STAIRVILLE LED Vintage Bowl 50 RGBA user manual

AQUAMAXX
AQUAMAXX Aqua CC II quick start guide

ELUSIVE WILDLIFE
ELUSIVE WILDLIFE Blind Sider-X2 manual