Fluke RSE30 User manual

RSE30/RSE60/RSE30H/RSE60H
Thermal Camera
Users Manual
March 2022 (English)
© 2022 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The
warranty period is two years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90
days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not
apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected,
contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will
operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on
non-defective media. Fluke does not warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no
authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is
purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the
right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted
for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement
of a defective product which is returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information,
then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB
Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer,
transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination,
alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the
product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs
and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer
transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY
CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of
incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any
provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such
holding will not affect the validity or enforceability of any other provision.
11/99
Fluke Corporation
Fluke Beijing Service Center
P.O. Box 9090
Rm101, 1/F.,Tong Heng Tower
Everett, WA 98206-9090
No. 4 Hua Yuan Road Hai Dian
U.S.A.
District, Beijing 100088, P.R.C.

i
Contents
Title Page
Introduction ...................................................................................................................................................1
Contact Fluke................................................................................................................................................1
Safety Information.........................................................................................................................................1
Warnings and Cautions..........................................................................................................................1
Conventions...........................................................................................................................................2
Product Familiarization .................................................................................................................................2
Standard Packaging...............................................................................................................................2
Product Features ...................................................................................................................................3
Operation ......................................................................................................................................................4
Connect to a PC or the Ethernet............................................................................................................5
IP Address .............................................................................................................................................5
Fluke SmartView IR Software .......................................................................................................................6
Optional lens .................................................................................................................................................7
Maintenance .................................................................................................................................................8
To Clean the Case .................................................................................................................................8
Lens Care ..............................................................................................................................................8
Specifications................................................................................................................................................9
General Specifications ...........................................................................................................................9
Detailed Specifications.........................................................................................................................10
Dimensions .................................................................................................................................................12
Size......................................................................................................................................................12
Interface Definition ......................................................................................................................................14


1
Introduction
The RSE30、RSE60、RSE30H and RSE60H Thermal Camera (the Product or Cameral) are
stationary, infrared imaging cameras for use in many applications, which include equipment
troubleshooting, electricity, preventive and predictive maintenance, building diagnostics, and research
and development.
The Cameras can stream live infrared video to a PC that has Fluke SmartView IR installed. The Fluke
SmartView IR is the standard professional thermal image analysis software which can be used for
professional analysis and reporting of thermal images and fully-radiometric thermal videos.
Contact Fluke
Fluke Corporation operates worldwide. For local contact information, go to our website:
www.fluke.com (English) or cn.fluke.com (Chinese)
To register your product, view, print, or download the latest manual or manual supplement, go to our
website.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
Safety Information
Warnings and Cautions
A Warning identifies hazardous conditions and procedures that are dangerous to the user. A Caution
identifies conditions and procedures that can cause damage to the Product or the equipment under
test.
General Safety Information is in the printed Safety Information document that ships with the Product
and at www.fluke.com (English) or cn.fluke.com (Chinese). More specific safety information is listed
where applicable.

RSE30/RSE60/RSE30H/RSE60H
Users Manual
2
Caution
Storage and/or continual operation of the Camera in extreme ambient
temperature conditions can result in temporary interruption of operation. If this
occurs, let the Camera stabilize (cool down or warm up) before you resume
operation.
Conventions
For keys, buttons, menus, options, fields, and components mentioned in this Manual:
Bold fonts are generally used to indicate printed words or names of keys/buttons on the Product’s
panel or body.
"Bold fonts within quotation marks" are generally used to indicate the content or options displayed
on the Product’s screen.
Fonts in blue generally refer to hyperlinks, including links to the Internet and cross-references within
this Manual. Click the link to go to the targeted content.
For readability purposes, list items are generally not enclosed in double quotes, because they are
easy to be identified to be the content on screen and panel by context.
Product Familiarization
The manual explains features for multiple models. As different models have different features, some
of the information in this manual may not be applicable to your product. Use Table 2 to understand
the features of your Camera.
Standard Packaging
To prevent damage during shipment, the Product is shipped in a specially designed package. Please
check the Product carefully and inform the carrier of any damage.
When unpacking the Product, please check the standard equipment listed in Table 1 and other
ordered parts listed on the packing list. If there is any shortage of parts, please inform the nearest
Fluke Technical Service Center or the Service Center in the place of purchase.
If you need to reship the Product, use the original package. If the original package is not available,
order a new package from Fluke according to the Product’s model.
Figure 1 and Table 1 list the standard equipment that comes with the Product. For optional lenses,
see Optional lens.

Thermal Camera
Product Familiarization
3
Figure 1. Standard equipment
Table 1.Standard equipment
Item Description Quantity Item Description Quantity
A Thermal Camera (standard
lens)
1 F Allen wrench 1
B Lens cap (removable) 1 G Tripod adapter block 1
C Power adapter 1 H Mounting screw, M2X5 4
D Power connector 1
I
Documents including each
of Safety Sheet, Quick
Reference Guide, Quality
Certificate and Warranty
Card.
1
E Ethernet cable, 3 m
1
Product Features
A summary of product features is listed in Figure 2 and Table 2.

RSE30/RSE60/RSE30H/RSE60H
Users Manual
4
Figure 2. Product features
Table 2.Product features
Item Description Item Description
A Top mounting holes F Power input port
B Infrared lens G Functional earth
C Interface for RS-485 communication, relay
and optocoupler H LED indicator
D LAN communication interface I Tripod/accessory mounting holes
E Reset button
Operation
The Camera and the Fluke SmartView IR software need a network connection to work properly. Set
up your network without interference from other systems. SmartView IR is a data-intensive
application. Use of other data-intensive applications (audio or video stream) on the PC or in the same
network system can cause loss of data.
Note
All thermal cameras need sufficient warm-up time for accurate temperature
measurements and best image quality. Warm-up time can vary by model and
environmental conditions. Wait a minimum of 30 minutes for the most accurate
temperature measurement. When you move the camera between environments with
large differences in ambient temperature, allow for additional adjustment time.
LAN ( PoE)
4
3
5
678
9
2
1

Thermal Camera
Operation
5
Connect to a PC or the Ethernet
1. Stabilize the Product either on a flat surface or a tripod.
2. Connect one end of the Ethernet cable to the Ethernet jack on a PC or a switch, connect the other
end of the Ethernet cable to the LAN interface on the end of the Camera (Din Figure 2).
3. Connect the AC plug of the power adapter to the power outlet and connect one end of the power
adapter to the power input port on the end of the Product (Fin Figure 2). The LED indicator lights
green indicating the power on status.
4. Warm-Up the Product, then remove the lens cover. Follow the instructions in section IP Address
and run the Fluke SmartView IR software.
Figure 3.Connect to a PC or the Ethernet
IP Address
To connect the Camera to your PC:
1. Connect the Camera to your PC or the network as described in section Connect to a PC or the
Ethernet.
2. Set the local IP address of the server to be in the same network segment as the Camera.

RSE30/RSE60/RSE30H/RSE60H
Users Manual
6
3. Open the IPConfig software and search for the Camera’s IP address. The Camera's IP address is
192.168.1.100.
4. Start the Fluke SmartView IR software and connect to the Camera using the IP address
192.168.1.100.
5. For the next steps, please see the Fluke SmartView IR software’s Users Manual.
Note
The default IP address of the Product is 192.168.1.100, and when you use the Reset
button to reset the Product, the default IP address is restored. Do not set servers or
other PCs and network devices to this IP address. To change the IP address of the
Product, see the instruction manual for the IPConfig software.
Fluke SmartView IR Software
The Fluke SmartView IR software can be used with the Camera and contains functions for analyzing
images, organizing data and information and generating professional reports.
Use the SmartView IR software to:
•stream radiometric videos
•capture fully-radiometric videos or imagers
•analyze images
•plot data trends
•export data
•customize reports
To download and install the SmartView IR Software.
1. On the PC, go to: www.fluke.com/smartviewIR.
2. Download the SmartView IR software to the PC according to the instructions on the Product page.
3. On the PC, follow the instructions to install SmartView IR software. (Administrator privileges are
required for the installation.)
For details on remote viewing and control of the Product connected to the SmartView IR software, see
the instructions for the software.

Thermal Camera
Optional lens
7
Optional lens
Lens Name
Lens Parameters
Standard Lens Wide-Angle Lens Telephoto Lens
RSE30
Field of View (FOV) 25° x 18.7° 50° x 37.5° 12° x 8.9°
Spatial Resolution (IFOV) 1.13 mrad 2.07 mrad 0.57 mrad
Minimum Focus Distance 0.3 m 0.3 m 1 m
Focal Length 15 mm 8.2 mm 30 mm
RSE60
Field of View (FOV) 25° x 18.7° 50° x 37.5° 12° x 8.9°
Spatial Resolution (IFOV) 0.68 mrad 1.31 mrad 0.34 mrad
Minimum Focus Distance 0.3 m 0.3 m 1 m
Focal Length 25 mm 13 mm 50 mm
RSE30H
Field of View (FOV) 25° x 18.7° 50° x 37.5° 12° x 8.9°
Spatial Resolution (IFOV) 1.13 mrad 2.32 mrad 0.53 mrad
Minimum Focus Distance 0.5 m 0.5 m 1.5 m
Focal Length 15 mm 7.34 mm 32.2 mm
RSE60H
Field of View (FOV) 25° x 18.7° 50° x 37.5° 12° x 8.9°
Spatial Resolution (IFOV) 0.67 mrad 1.39 mrad 0.32 mrad
Minimum Focus Distance 0.5 m 0.7 m 5 m
Focal Length 25.3 mm 12.2 mm 53.9 mm
Note: The product is shipped with standard lens, optional lens is add-on installation method, and the
temperature measurement will only be guaranteed for the optional lens.

RSE30/RSE60/RSE30H/RSE60H
Users Manual
8
Maintenance
There are no parts requiring for users to repair and maintain inside the Product, and no special
maintenance is needed. It is only necessary to clean and maintain the lens regularly.
To Clean the Case
Clean the case with a damp cloth and a weak soap solution. Do not use abrasives, isopropyl alcohol,
or solvents to clean the case or lens.
�Caution
To prevent damage to the case, do not get the alcohol on the case.
Lens Care
�Caution
To prevent damage to the infrared lens:
•Carefully clean the infrared lens. The lens has a delicate anti-reflective
coating.
•Do not clean the lens too vigorously because this can damage the anti-
reflective coating.
To clean the lens:
1. Use a pressurized can of air or a dry nitrogen-ion gun, if available, to blow off the particulates from
the lens surface.
2. Soak a lint-free cloth in a commercial lens cleaning liquid that contains alcohol, ethyl alcohol, or
isopropyl alcohol.
3. Squeeze the cloth to remove excess liquid.
4. Wipe the lens surface in one circular motion and discard the cloth.
5. If needed, repeat with a new lint-free cloth.

Thermal Camera
Specifications
9
Specifications
General Specifications
RSE30 RSE60 RSE30H RSE60H
Temperature
Operating -10 °C - 50 °C
Storage -40 °C - 70 °C
Altitude
Operating 2 000 m
Storage 12 000 m
Relative Humidity <90 % RH
Power
Power supply 12 V/24 V, PoE
Power consumption
(Typical)
3 W 4 W 3 W 4 W
Safety IEC 61010-1: Pollution degree II
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Industry Electromagnetic Environment, CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency
energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly
connected to a low-voltage power supply network that supplies buildings used for domestic purposes.
There may be potential difficulties in ensuring electromagnetic compatibility in other environments due
to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide
adequate protection to radio reception in such environments.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connec
ted to
a test object.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller
or user should take notice of it. This equipment i
s intended for use in business environments and not to
be used in homes.
Size (H x W x L) 142.25 mm x 71 mm x 70 mm
(Standard lens, without base)
157.25 mm x 80 mm
x 79 mm
(Standard lens,
without base)
164.6mm x 80 mm x
79 mm
(Standard lens,
without base)
Weight 706g
(Standard Lens)
718g
(Standard Lens)
713g
(Standard Lens)
993g
(Standard Lens)
Mounting Bottom and top mounting supported
Tripod mounting through adapter: 2 x 1/4-UNC-20 standard tripod mounting holes
IP Rating IEC 60529: IP40

RSE30/RSE60/RSE30H/RSE60H
Users Manual
10
Detailed Specifications
RSE30 RSE60 RSE30H RSE60H
Temperature Measurements
Temperature
Range
-20 °C - 650 °C -20 °C - 650 °C
-20 °C - 2000 °C -20 °C - 2000 °C
Temperature Measurement Range
Subrange 1 -20°C to 150 °C -20 °C to 150 °C -20 °C to 150 °C -20 °C to 150 °C
Subrange 2 0 °C to 650 °C 0 °C to 650 °C 0 °C to 650 °C 0 °C to 650 °C
Subrange 3 300 °C to 2000 °C 300 °C to 2000 °C
Temperature
Accuracy*
Operating temperature:15℃~35℃, ±2 °C or ±2 % of rdg, whichever is greater
-10 °C ~15 °C or 35 °C ~50 °C, ±4 °C or ±4 % of rdg, whichever is greater
Infrared Resolution 384 × 288 640 × 480 384 × 288 640 × 480
Detector Type Focal Plane Array FPA, Uncooled Microthermal
Detector Frame Rate
60 Hz
Thermal Sensitivity
(NETD)**
<50 mk <30 mk <50 mk <30 mk
Pixel Spacing 17 μm
Infrared Spectral
Band
7.5 μm to 14 μm
Field of View (FOV) See Optional lens
Spatial Resolution
(IFOV)
See Optional lens
Minimum Focus
Distance
See Optional lens
Lens Focal Length See Optional lens
Focus System Auto (in SmartView IR)
Global Temperature
Measurement
Correction
Emissivity (0.01 to 1.00), Reflected Temperature (Background Temperature),
Transmittance, Atmospheric Temperature, Relative Humidity, Target Distance
Analysis Software SmartView IR
Color Palettes 10 color palettes, for example Ironbow, black-white, rainbow, and more
the palettes can be inverted
Video Stream
Compression
Standard
H.264

Thermal Camera
Specifications
11
RSE30 RSE60 RSE30H RSE60H
Video Main stream
Pixel: 384 x 288
Frequency: 30 Hz
Bandwidth: 1.8 Mb
Sub stream
Pixel: 384 x 288
Frequency: 30 Hz
Bandwidth: 100 kb
Main stream
Pixel: 640 x 480
Frequency: 30 Hz
Bandwidth: 2.5 Mb
Sub stream
Pixel: 320 x 240
Frequency: 30 Hz
Bandwidth: 100 kb
Main stream
Pixel: 384 x 288
Frequency: 30 Hz
Bandwidth: 1.8 Mb
Sub stream
Pixel: 384 x 288
Frequency: 30 Hz
Bandwidth: 100 kb
Main stream
Pixel: 640 x 480
Frequency: 30 Hz
Bandwidth: 2.5 Mb
Sub stream
Pixel: 320 x 240
Frequency: 30 Hz
Bandwidth: 100 kb
Fully-Radiometric
Streaming
30 Hz 25 Hz 30 Hz 25 Hz
Pan-Tilt Control Support Pelco-D protocol
Temperature
Measurement Area
Support 5 temperature measurement points, 10 temperature measurement lines, 10
temperature measurement areas, support Modbus output (the Modbus output is
mutually exclusive with the Pan-Tilt control)
Ethernet Type 10M/100M/1000M, adaptive
Network Protocols IPv4, UDP, TCP, RTSP, RTCP, RTP
Concurrent Access 10 channels for main stream and sub stream, 1 channel for fully-radiometric
Access standard ONVIF
Network Interface RJ45, with status indicator
Alarm Input/Output 1 relay output: load capacity: 24 V, 1.5 A
1 optocoupled output: output capacity: 3.3 to 24 V, 35mA maximum output current
1 channel optocoupled input: input capability: 3.3 to 24 V, 5mA-to-15mA input current
Serial Port 1 RS-485
* Nominal measurement distance. RSE30/RSE60 is at 1 meter, RSE30H/RSE60H is at 2 meters.
** Best possible

Thermal Camera
Dimensions
13
Side view
Rear view
Figure 4. Product dimensions

RSE30/RSE60/RSE30H/RSE60H
Users Manual
14
Table 3.Product dimensions
a b c d e f g h i
RSE30/60 142.25 28.00 56.75 16.00 14.00 63.75 70.00 78.00 71.00
RSE30H 157.25 28.00 61.25 16.00 14.00 68.25 79.00 87 80.00
RSE60H 164.00 28.00 68.60 16.00 14.00 75.60 79.00 87.00 80.00
Note: The unit is mm.
Interface Definition
Figure 5. Product interfaces
Power
LAN (PoE)Reset
DC12V\24V
RS485
D+ D- + -
RelayOut In GND
+ -
1
2
3
4
5
6

Thermal Camera
Interface Definition
15
Table 4.Product interface definition
Item Name Description
a LAN interface RJ45 socket. Gigabit Ethernet port. Power over Ethernet (PoE) supported.
b
Communication
interface
connector
Communication socket.
RS485 communication interface, relay input, optocoupler input/output and
signal ground included. See table below.
Interface Pin Description
RS485
D+
Data terminal
D-
Data terminal
Relay + Positive relay pole 3.3 V to
24 V, 1.5 A
-
Negative relay pole
Optocoupler
Out
Optocoupler output. 3.3 V to
24 V, 35 mA
In
Optocoupler input, 3.3 V to
24 V, 5 mA to 15 mA
Signal ground GND Signal grounding
c Power indicator
d Functional earth
e Power interface
DC12/24 V.
+: Connect to the positive pole of the power supply
-: Connect to the negative pole of the power supply
f Reset button Restore factory settings. IP address is reset to 192.168.1.100
Note
:
Please refer to the SDK documents for detailed operations.

RSE30/RSE60/RSE30H/RSE60H
Users Manual
16
This manual suits for next models
3
Table of contents
Other Fluke Thermal Camera manuals

Fluke
Fluke Ti105 User manual

Fluke
Fluke Ti27 Instruction manual

Fluke
Fluke Ti20 User manual

Fluke
Fluke Ti100 User manual

Fluke
Fluke TiS10 User manual

Fluke
Fluke Ti40FT-20 User manual

Fluke
Fluke ThermoView TV30 Series User manual

Fluke
Fluke Ti9 Instruction manual

Fluke
Fluke Ti480 User manual

Fluke
Fluke TiX520 User manual

Fluke
Fluke Ti40FT-20 User manual

Fluke
Fluke Ti300 User manual

Fluke
Fluke Ti20 User manual

Fluke
Fluke Ti50FT-20 User manual

Fluke
Fluke Ti32 Instruction manual

Fluke
Fluke Professional Ti300 PRO User manual

Fluke
Fluke tix640 User manual

Fluke
Fluke FlexCam Ti40 User manual

Fluke
Fluke TiR105 User manual

Fluke
Fluke TiR125 Configuration guide