Tetra®LED Control Module
(GECLPS5-2)
GE
Lighting
Installation Guide
imagination at work
24
Volt
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before
servicing or installing product.
• Properly ground Tetra®power supply.
RISK OF FIRE
• Use only Tetra®supply wire to make connection from
Tetra®power supply to Tetra®LED strip.
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82 mm2)
• Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
• N’utilisez que le l d’approvisionnement Tetra®pour faire la connexion entre
l’alimentation Tetra®et la bande DEL Tetra®.
• N’utilisez que des ls approuvés pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82 mm2).
• Respectez tous les codes locaux.
CAUTION/ATTENTION
RISK OF INJURY
• While performing installations described, gloves, safety glasses
or goggles should be worn.
RISQUE DE BLESSURE
• Lors de l’exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
Prepare Electrical Wiring
Electrical Requirements
• Limited to use in dry and damp locations.
• The grounding and bonding of the LED Driver shall be done in
accordance with National Electric Code (NEC) Article 600.
• Follow all National Electric Codes (NEC) and local codes.
• These products are only suitable for connection to a circuit
from a Class 2 power source. These products have not been
evaluated for use when connected to a power source that does
not comply with Class 2 voltage and energy limited supplies.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must
accept any interference received, including interference that
may cause undesired operation.
Note: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
This Class [A] RFLD complies with the Canadian standard
ICES-003. Ce DEFR de la classe [A] est conforme à la NMB-003
du Canada.
LED Control Module Features
• LED Control Module for GECLPS5 and GECLPS6 retrot.
• UL: Class 2 input.
Remove Existing Lighting Equipment
Electrical Connections
Turn off power and remove panel from the channel
letter.
1Remove the existing GECLPS5. Do not remove existing
channel letters and wiring.
NOTE: Follow all federal and local regulations when
disposing of existing LED drivers.
2
Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure that the
branch circuit supplying the existing LED power supply will be within the voltage ratings of the new LED power supply, and have a
current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).
If removal of the existing lighting equipment (see Step 2 in this section) eliminates the disconnect switch, as required by applicable local,
state, or country electrical codes; a new disconnect switch must be installed. If required, the disconnect switch shall be installed by
qualied personnel, in accordance with applicable local, state, and country electrical codes.
Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in all holes
0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an
aluminum or zinc coated steel patch with rivets and sealant.
=
GECLPS5
GECLPS5-2GEPS24-100-XX
Two GECLPS5-2 and two 24VDC, 100W, Class 2 Tetra
LED Drivers will be required to replace each GECLPS5 or
up to four GECLPS6 LED drivers.
NOTE: Mount the LED driver and LED control module
within the sign or other enclosure.
If installing multiple LED control modules or LED drivers in
the same compartment, keep them at least 2” (50.8mm)
apart end to end and 4” (101.6mm) apart along the sides.
NOTE: All drivers except GEPS24-180U must be installed
in a raceway or be provided with a GEPSJB60 LED driver
extended enclosure.
3 4
4”
2”
LED driver LED driver
LED driver
LED driver
Components
1
2
3
UL certied 22-14 AWG (0.33-2.08 mm2) wire connectors or
22-18 AWG (0.33-0.82 mm2) inline/IDC connectors.
Tetra®24 Volt Power Supply.
Tetra® LED Control Module.
1 2 3
GECLPS5-2GEPS24-100-XX
123456
123456
8
9
The following chart indicates the Tetra Strip load that can be placed on the Power Supply based on the character code on the LED and the dip switch
setting chosen. For example, when the Tetra Strip is marked with the character code EB5, the “5” on the dip switch can be set to the ON position to
achieve neon-equivalent performance. At
this setting, the GECLPS5-2 power supply
can support up to 64 ft. (19m) of the 6
LED per foot Tetra Strip. If you change the
dipswitch setting and ip #4 switch to the
ON position, the power supply can support
up to 80 ft. (24m) of Tetra Strip. The footage
guidelines vary based on the type of Tetra
Strip being used. The charts below provide
the total footage requirements for each Tetra
Strip type. To determine the footage for each
power supply bank, divide the total footage
by four.
CAUTION: Avoid setting the dip switch to the
ON position with any setting not listed in
the chart unless stated otherwise (i.e. Border
Tube Installation). If these requirements are
not followed, the Tetra Strip and Power
Supply warranty will be void.
1234 5 6
123456
123456
Dip Switch Setting Chart for Tetra Strip
Chart Assumes
LED Code of
“XX5”
Dip
Switch
Setting
GECLPS5 Retrot GECLPS6 Retrot
Notes
6 LEDs/ft.
(20/m) 5 LEDs/ft.
(16/m) 6 LEDs/ft.
(20/m) 5 LEDs/ft.
(16/m)
Matches
Bin Code
64 ft.
(19.0m)
80 ft.
(24.4m)
16 ft.
(3.6m)
20 ft.
(6.1m)
Recommended
for Optimal
Performance
-1 80 ft.
(24.4m)
96 ft.
(29.3m)
20 ft.
(6.1m)
24 ft.
(7.3m)
Intensity of the
Tetra Strip will
be reduced by
approximately
10% to 20%
+1 48 ft.
(14.6m)
64 ft.
(19.0m)
12 ft.
(3.6m)
16 ft.
(3.6m)
Intensity of the
Tetra Strip will
be increased by
approximately
10% to 20%
With power off, set the correct dip switch according to the Dip Switch Setting Chart (see below for detailed explanation).
NOTE: For proper operation, verify that only one switch is set to the “ON” position.
Replace the dip switch cover and perform a quick test by turning the system on to ensure the channel letter LEDs are lit.
Dip Switch Settings
Wire AC line to LED driver(s) in
accordance with the applicable
local, state, and country electrical
codes. Connect black to black
or brown, white to white or blue,
and green to green using 18 AWG
(0.82mm2) wire connectors.
5Connect the red stripe wire (+)
of the LED control module to the
red wire (+) of the power supply.
Connect the white wire (-) of the
LED control module to the black or
blue wire (-) of the power supply.
Connect each LED control module
output lead pair to each Tetra LED
module supply lead pair using
UL certied wire connectors. Cap
each unused output lead with a UL
certied wire connector.
6 7
AC line
Black to black
or brown
LED driver LED control module
Green to
green
White to white
or blue
Red (+) Red stripe (+)
To LED modules
Cap unused leads
Inline connector
White (-)Black or blue (-)
LG4
Character Code
of Tetra® Strip Dip Switch
Setting
XX1 1
XX2 2
XX3 3
XX4 4
XX5 5
XX6 6
WARNING: Do not connect outputs
in series or parallel.
Specications
Performance Data Min Typical Max
Input Voltage (VDC) 23 24 25
Input Current (A) - - 3
Output Voltage (VDC) 3.1 - 3.8
Output Current (ADC) - - 4.0
Output Power (W) - - 30.4
Environmental Operating Temperature Range -40°C +25°C +55°C*
Environmental Humidity (non-condensing) 0% - 95%
Environmental Storage Temperature Range -40°C - +85°C
Dimensions 9.5 in. x 1.7 in. x 1.2 in. (241 mm x 43.2 mm x 30.5 mm)
* Maximum case temperature is 85°C
NOTE: Always use dip switch 6 for
Tetra Power White Strip.
NOTE: Power off the LED control
module when setting the dip
switches.
NOTE: Do not connect outputs in
series or parallel.
NOTE: When installing power supply,
connect to the appropriate sized
building breaker or disconnect device for line and neutral connections, in accordance with local, state or country regulations.
NOTE: The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code
(NEC) Article 600.
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
Conforms to the following standards:
1234 5 6
Dip Switch Setting Chart for Tetra Power White Strip
Dip
Switch
Setting
GECLPS5 GECLPS6
Notes
2 LEDs/ft.
(6 LEDs/m) 3 LEDs/ft.
(9 LEDs/m) 2 LEDs/ft.
(6 LEDs/m) 3 LEDs/ft.
(9 LEDs/m)
Dip Switch
6
28 ft.
(8.5m)
20 ft.
(6.1m)
7 ft.
(2.1m)
4.5 ft.
(1.4m)
No bank may
exceed 14
modules
www.gelighting.com
GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to
change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting is a business of the General Electric Company. © 2016 GE.
SIGN164 (Rev 11/15/16)
GE2026-2818

Other GE Control Unit manuals

GE Intellix BMT 330 User manual

GE

GE Intellix BMT 330 User manual

GE WH18X28174 Configuration guide

GE

GE WH18X28174 Configuration guide

GE ATS7310 Assembly instructions

GE

GE ATS7310 Assembly instructions

GE TLE Scalable 150 User manual

GE

GE TLE Scalable 150 User manual

GE 22158 User manual

GE

GE 22158 User manual

GE IC3645SR4T405CT1 User manual

GE

GE IC3645SR4T405CT1 User manual

GE ATS7200 User manual

GE

GE ATS7200 User manual

GE Ziton ZP3-ECU User manual

GE

GE Ziton ZP3-ECU User manual

GE L60 User manual

GE

GE L60 User manual

GE IC3645SR4W746N5 User manual

GE

GE IC3645SR4W746N5 User manual

GE WIU-4 User manual

GE

GE WIU-4 User manual

GE B90 User manual

GE

GE B90 User manual

GE Masoneilan 77-6 User manual

GE

GE Masoneilan 77-6 User manual

GE S-500 Series User manual

GE

GE S-500 Series User manual

GE EX2100 User manual

GE

GE EX2100 User manual

GE ReliaGear LV MCC User manual

GE

GE ReliaGear LV MCC User manual

GE CR194 User manual

GE

GE CR194 User manual

GE NX-1710E - Single Door Control Module Installation and operation manual

GE

GE NX-1710E - Single Door Control Module Installation and operation manual

GE C-800 Series User manual

GE

GE C-800 Series User manual

GE EntelliGuard TU User manual

GE

GE EntelliGuard TU User manual

GE Dialog User manual

GE

GE Dialog User manual

GE MiCOM P40 Agile User manual

GE

GE MiCOM P40 Agile User manual

GE VersaMax IC200ALG630 User manual

GE

GE VersaMax IC200ALG630 User manual

GE MM3 User manual

GE

GE MM3 User manual

Popular Control Unit manuals by other brands

Interlogix SuperBus 2000 PIV installation instructions

Interlogix

Interlogix SuperBus 2000 PIV installation instructions

MOTKA MK-200 user manual

MOTKA

MOTKA MK-200 user manual

KONTRONIK POWERJAZZ Operation manual

KONTRONIK

KONTRONIK POWERJAZZ Operation manual

Jung 2072 TSM operating instructions

Jung

Jung 2072 TSM operating instructions

Mitsubishi Electric MELSEC iQ-R Series user manual

Mitsubishi Electric

Mitsubishi Electric MELSEC iQ-R Series user manual

oventrop Regufloor HN Installation and operating instructions

oventrop

oventrop Regufloor HN Installation and operating instructions

Kemper 360 Installation instruction

Kemper

Kemper 360 Installation instruction

Bryant 580J 04-30 Controls, Start-Up, Operation and Troubleshooting

Bryant

Bryant 580J 04-30 Controls, Start-Up, Operation and Troubleshooting

Puls YR80.242 installation manual

Puls

Puls YR80.242 installation manual

Bosch ISP-EMIL-120 installation manual

Bosch

Bosch ISP-EMIL-120 installation manual

Wistron NeWeb DHUK-SY22 user manual

Wistron NeWeb

Wistron NeWeb DHUK-SY22 user manual

CEBEK I-210 quick start guide

CEBEK

CEBEK I-210 quick start guide

urmet domus BiBus II ED. 1072 manual

urmet domus

urmet domus BiBus II ED. 1072 manual

Omega DMD1080 user guide

Omega

Omega DMD1080 user guide

SEA SLIDE NEW MAG instruction manual

SEA

SEA SLIDE NEW MAG instruction manual

Von Duprin DE5300 Special instructions

Von Duprin

Von Duprin DE5300 Special instructions

Maxsys PC4204CX installation instructions

Maxsys

Maxsys PC4204CX installation instructions

Current Technology ISM Series Installation, operation and maintenance manual

Current Technology

Current Technology ISM Series Installation, operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.