GE ACT17CWA User manual

Table of Contents
Parts and Functions
Interface Display ....................................1
Icons .............................................2
Dip Switch .........................................4
Operation
Mode Key .........................................6
Fan Key ...............................................6
Temperature Adjustment Keys .........................7
Special Function
Special Function Selection ............................8
Installer Settings
Adjust ECO Parameters .............................10
Child Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Lock Settings......................................11
Fahrenheit / Celsius ................................11
Temperature Compensation ..........................12
Forced Defrost/Cooling/Heating .......................12
Error Checks ......................................13
Mode Restriction ..................................14
Mode Combination Settings ..........................15
Wiring Instruction...................................15
Wired Controller
Installation and Operation Manual
ACT17CWA
• Please read this manual before use
• Please keep this manual for future reference. 49-5000395 Rev. 5
GEA 08-21

SUB
MAIN
Full Display
1
Parts and Functions
Interface Display

/
2
Room temperature display
(dip switch SW1-2 on).
Set temperature display
Filter
HRV (Heat Reclaim Ventilation), if HRV
function is set, it will display this icon
Error icon displays detected fault
ECO mode on
Central/lock when connected to a central
controller
UP/DOWN louver swing
LEFT/RIGHT louver swing
Child lock on
Parts and Functions
Icons

MAIN / SUB Main / Subordinate wired
controller
Quiet Fan Speed
(some models)
Low Fan Speed
Medium Fan Speed
High Fan Speed
Turbo Fan Speed
(some models)
Auto Fan speed is indicated by the display automatically
stepping from low to high repeatedly.
Auto Mode
Cooling Mode
Heating Mode
Fan Mode
3
Parts And Functions

4
'LS VZLWFK GH¿QLWLRQ
Dip Switch SW1
Dip Switch
SW1 ON OFF Default
Sw1-1 Subordinate wired
controller Main wired controller OFF
Sw1-2 Room temperature
display on Room temperature
GLVSOD\Rႇ OFF
Sw1-3
Room temperature
collected from indoor unit
Room temperature
collected from controller OFF
Sw1-4 6\VWHPUHPDLQVRႇDIWHU
power loss Auto restart after power
loss OFF
Sw1-5 Old protocol (models
developed before Aug.
2013) New protocol OFF
Sw1-6 Backlight always on
Backlight 15 second auto
time out
OFF
Sw1-7 Reserved Reserved OFF
Sw1-8 Reserved Reserved OFF

5
Dip Switch SW2
Initialization
:KHQWKHPLQLVSOLWV\VWHPLVSRZHUHGRQZLOOÀDVKEH-
tween the Room Temperature display and the Set Temperature
display until communication is established with the indoor unit.
Press to power ON or power OFF the control. A tone
will be heard with every button press or when a command is
UHFHLYHGE\DUHPRWHFRQWURO,IDFRQÀLFWLQJFRPPDQGLVUH-
ceived, then the tone will sound 3 times.
Audible Alert
Dip Switch
SW2 ON OFF Default
Sw2-1 Mode Lock Normal OFF
Sw2-2 1REXWWRQFRQ¿UPDWLRQWRQH7RQHZLOO
still sound when command is sent by
wireless remote. Tone on OFF
Sw2-3 Reserved Reserved OFF
Sw2-4 Reserved Reserved OFF

Quiet Fan Speed
(some models)
Low Fan Speed
Medium Fan Speed
High Fan Speed
Turbo Fan Speed
(some models)
6
Mode key:
•
Each press of the MODE button will change the operating mode from
$XWR±&RRO±+HDW±)DQ±'U\'HKXPLGL¿FDWLRQ±$XWR«
• Each mode has its initial default fan speed.
Mode Key / Fan Key
Mode Fan speed Temperature
Auto Auto 76°F
Cool High 76°F
Heat Auto 76°F
Fan Low No temperature display
'U\'HKXPLGL¿FDWLRQ Auto 76°F
Initial
State
Fan Key:
Each press of the FAN button will change the fan speed from
Auto – Quiet (some models) – Low – Medium – High – Turbo
VRPHPRGHOV±$XWR«

7
Temperature Adjustment Keys: /
• Press the TEMP+ or TEMP- keys to change the temperature
by 1°F increments.
• The temperature set point range forAuto, Cooling, Heating
DQG'U\'HKXPLGL¿FDWLRQLV)a),I(&2LVRQ
then temperature range will change per the ECO setting
parameters).
• The temperature is set independently underAuto, Cooling,
Heating and Dehumidify modes. Once the temperature is set
in each mode the setting will be saved for that mode.
• In fan mode, Temp +/- keys do not work.
Temperature

8
Special Function Selection:
With the control powered on, press and hold the TEMP+ for
5 seconds to enter the special function menu. All the special
function icons will display. Use the TEMP+ and TEMP- buttons
to move between icons. Use FAN button to select function.
Function Selection

9
Function Selection
50

10
Adjust ECO Parameters:
• Cooling: Power on the unit. Adjust set temperature to
86°F. Press and hold FAN and TEMP+ for 5 seconds. The
minimum allowable set temperature will be displayed in the
top right corner. Use TEMP+/- to change the parameter,
then press FAN save. The default minimum temperature is
73°F.
• Heating: Power on the unit. Adjust set temperature 60°F.
Press and hold FAN and TEMP- for 5 seconds. The
maximum allowable set temperature will be displayed in the
top right corner. Press TEMP+/- to change the parameter,
then press FAN to save. The default maximum temperature
is 79°F.
'U\'HKXPLGL¿FDWLRQ(&2SDUDPHWHUVDUHWKHVDPHDV
Cooling.
Child Lock:
• Press and hold TEMP+ and TEMP- for 5 seconds to
activate/deactivate the Child Lock function. When the Child
Lock function is active, will appear.
Installer Settings

11
Central/Lock Function: /
Function is active only when system has a central control, such
as the YCZ-A004. This setting is activated only by the central
Control.
Fahrenheit Setting and Display:
• Fahrenheit to Celsius: Adjust set temperature to lowest
VHWWLQJ)ZKHQ(&2LVRႇ3UHVVDQGKROG7(03IRU
15 seconds. During the 15 second count the display will
beep once at 5 seconds and display error codes. Then after
another 5 seconds, the display will beep once again and
display 00, after 5 more seconds the display will change to
Celsius.
• Celsius to Fahrenheit: Adjust set temperature to highest
VHWWLQJ&ZKHQ(FRLVRႇ3UHVVDQGKROG7(03IRU
seconds. During the 15 second count, the display will beep
once at 5 seconds and enter Special Functions menu. Then
after another 5 seconds, the display will show 00, after 5
more seconds the display will change to Fahrenheit.
Central Control 2Q2ႇIXQFWLRQRQO\DYDLODEOH
Central Lock No functions available.
Lock Settings / Fahrenheit Setting

12
Set Temperature Compensation:
:LWKWKHGLVSOD\RႇSUHVVDQGKROGWKH)$1EXWWRQIRUVHFRQGV
The display will then show 0 (default) or current compensation set-
ting. Use TEMP+/- buttons to adjust the compensation. Compensa-
tion can be set in 1° increments
+/- 8°F (0.5°C increments up to +/-4°C).
• Temperature compensation changes the ambient temperature
reading. If the system is sensing the ambient temperature at 72°F
and the compensation is set to -2° then the system will use 70°F in
its operation to heat or cool.
Forced Defrost:
• Set to Heating mode, high fan, and 86°F (30°C), or highest
temperature if ECO is on. Press TEMP+ 6 times within 5 seconds.
7KUHHWRQHVZLOOFRQ¿UPWKDWWKHXQLWLVLQIRUFHGGHIURVWPRGH
Forced Cooling:
• Set mode to Cool. Tap ON/OFF. Tap any button, except ON/OFF,
to light the display. Press and hold ON/OFF for 5 seconds. LL will
GLVSOD\DQGWKHFRQWUROZLOOEHHSWZLFH7RH[LWWXUQRႇFRQWURODQG
turn it on again.
Forced Heating:
• Set mode to Heat. Tap ON/OFF. Tap any button, except ON/OFF,
to light the display. Press and hold ON/OFF for 5 seconds. HH will
GLVSOD\DQGWKHFRQWUROZLOOEHHSWZLFH7RH[LWWXUQRႇFRQWURODQG
turn it on again.
Temperature Compensation

13
How to check error:
• If there is an error, will display.
• Check error: Press and hold TEMP- button for 5 seconds.
The error history will appear in the top right corner. The
current error will appear in the middle of the screen. If there
is no error, “--” will display.
Error Checks

14
Mode Restriction Function:
• When SW2-1 is on, the system mode lock is on. This will
lock the mode to Heat, Cool, Dry or Fan. No button press
can change mode. All other control functions are available
VXFKDVIDQVSHHGVHWWHPSHUDWXUHDQGRQRႇ
• Mode can still be changed with a wireless control, another
wired control, or a central control.
• When setting mode lock, have control set to desired mode.
Set dipswitch SW2-1 to ON. Disconnect and reconnect
system power.
Checking Parameters (only applies to some models):
• Press and hold TEMP+ for 10 seconds to check the
parameters. The parameters will appear in the middle of the
screen to show indoor address (00-15), Letters will appear
after decimal display (AbCdEF). The detailed parameters will
VKRZRQWKHWRSULJKWFRUQHU6HHWDEOHIRUGH¿QLWLRQV
• If the control is connected to multiple indoor units, each
indoor unit can be viewed by pressing the FAN button. Then
use TEMP+/- to switch between connected indoor units.
Mode Restriction

A BC
A BC
15
:LWKWKHFRQWURORႇ
press and hold the MODE
button for 10 seconds.
Use the FAN button to
change available modes of
operation. 4 is default.
Mode Combination Setting
A: One control on one indoor
Indoor 1
Wired controller
Polar wire
Wired controller
Wired Controller Wiring Instruction
Wiring Connections
1.&DVVHWWH$%«$/«09$%«09$/«
'XFWHG$'«$0«09$'«09$+«
059:DOO0RXQW09$:«
2 Non-MRV Wall mount (AW...)
Indoor PCB board
Wired controller
LED3/R
SW1
CN4
CN3
CN5 CN1
A BC AB C
CN2
1 2 3 4
LED1/R
LED2/G
WK-B
LED4/G
A B C
Display Description Value
A Indoor sensor - Ambient (Tai) Temperature °F (°C)
b Indoor sensor - Vapor (Tc1) Temperature °F (°C)
C Indoor sensor - Liquid (Tc2 Temperature °F (°C)
d Indoor EEV position Half of actual position
E Indoor unit address Shown in hexadecimal
F Indoor unit central address Shown in hexadecimal
Parameter Inquiry:
Mode Combination Setting:

16
A BC
Indoor 2
Wired controller
A BC A BC
A BC
Indoor 1
Wired controller
A BC A BC
Indoor N
Wired controller
Indoor 15
Wired controller
Indoor 16
(main unit)
Wired controller
Control wiring of wired
controller, polar.
Wired controller
B: One Controller for up to 16 indoor
&DVVHWWH$%«$/«09$%«09$/«
'XFWHG$'«$0«09$'«09$+«
059:DOO0RXQW09$:«
A BC
Indoor 2
Wired controller
A BC A BC
A BC
Indoor 1
Wired controller
A BC A BC
Indoor N
Wired controller
Indoor 15
Wired controller
Indoor 16
(main unit)
Wired controller
Control wiring of wired
controller, polar.
Wired controller
'XFWHG$0$0«
• Addressing Indoor Units
• Each indoor unit must hvae a unique
address.
• &RPSDFW&DVVHWWH$%«XVH6:B
• /DUJH&DVVHWWH$/«XVH6:B
• 6OLP'XFW$'«XVH6:B
• +LJK6WDWLF'XFW$0«XVH6:B
• +LJK6WDWLF'XFW$0«$0«XVH
6:B
• $OO059LQGRRU09«XVH6:B
Dipswitch position Dipswitch position
Unit # 1 2 3 4 Unit # 1 2 3 4
5678 56 7 8
0* Rႇ Rႇ Rႇ Rႇ 8on Rႇ Rႇ Rႇ
1Rႇ Rႇ Rႇ on 9on Rႇ Rႇ on
2Rႇ Rႇ on Rႇ 10 on Rႇ on Rႇ
3Rႇ Rႇ on on 11 on Rႇ on on
4Rႇ on Rႇ Rႇ 12 on on Rႇ Rႇ
5Rႇ on Rႇ on 13 on on Rႇ on
6Rႇ on on Rႇ 14 on on on Rႇ
7Rႇ on on on 15 on on on on
* Unit 0 is connected directly to the control and is main

17
3. Non-MRV Wall Mount (AW...)
Wiring Connections
SW1
Wiredcontroller
Unit0 ... ...
(mainunit)
Unit1 Unit 15
ABC AB BB
CCC
AAABC
ABC
SW1 SW1
HighWall
WK-B
7KH¿UVWKLJKZDOOLQGRRUXQLWWR
connect with WK-B is considered as
main unit 0.
(2) Remove the jumpers on CN3 and
CN4.
(3) The wired control must connect to CN1
of the WK-B main unit (unit 0).
(4) Connect the CN2 on the main unit
(unit 0) to the next WK-B subordinate
unit (unit 1) CN1 or CN2. Only the
main unit (unit 0) must use CN1 for
the control. All others may use CN1 or
CN2. See Picture 2.2.
(5) Set the dipswitch address of the WK-B
adapter. The adapters ship with all
VZLWFKHVRႇPDLQ
C:
Two controllers on one indoor
Notice: For wired controller connection and warranty details, please
follow the corresponding indoor unit installation instructions.
LED3/R LED4/G
ABCABC
Wired controller Wired controller
Polar wire
SW1
CN4
CN3
CN5 CN1
A BC A BC
CN2
1 2 3 4
LED1/R
LED2/G
WK-B
Indoor PCB board
1RQ059:DOO0RXQW$:«&DVVHWWH$%«$/«09$%«09$/«
'XFWHG$'«$0«09$'«09$+«
059:DOO0RXQW09$:«
A BC
A BC
A BC
Indoor 1
Wired controller
Polar wire
Wired controller
Polar wire
Wired controller
Dipswitch position Dipswitch position
Unit # 1 2 3 4 Unit # 1 2 3 4
0* Rႇ Rႇ Rႇ Rႇ 8on Rႇ Rႇ Rႇ
1Rႇ Rႇ Rႇ on 9on Rႇ Rႇ on
2Rႇ Rႇ on Rႇ 10 on Rႇ on Rႇ
3Rႇ Rႇ on on 11 on Rႇ on on
4Rႇ on Rႇ Rႇ 12 on on Rႇ Rႇ
5Rႇ on Rႇ on 13 on on Rႇ on
6Rႇ on on Rႇ 14 on on on Rႇ
7Rႇ on on on 15 on on on on
* Unit 0 is connected directly to the control and is main

18
C
B
A
red
yellow
white
Wired Controller Wiring Instruction
Communication Wiring
*Ground only one end of the shielded cable
Wiring Diagrams
Communication wiring length (m/ft) Wire Size
< 100m/328ft 0.3mm2x3-core shielded wire
(22AWG,3wire)
PIW DQG PIW 0.5mm2x3-core shielded wire
(20AWG,3wire)
PIW DQG PIW 0.75mm2x3-core shielded
wire (18AWG,3wire)
PIW DQG PIW 1.25mm2x3-core shielded wire
(16AWG,3wire)
PIW DQG PIW 2mm2x3-core shielded wire
(14AWG,3wire)

19
2. Secure the back panel to the
wall using screws.
3. Connect the control
wires.
4. Attach the control to the
back panel by aligning the
bottom tabs and then press-
ing the top edge.
Wired Controller Wiring Instruction
Installation Diagrams
1. To take the front panel and back
panel apart, slide the front panel
up and press down on the back
panel.
Other manuals for ACT17CWA
1
Table of contents
Other GE Controllers manuals

GE
GE PACSystems* RX3i User manual

GE
GE ASTAT XL Series User guide

GE
GE VAT2000 Series User manual

GE
GE ProTrip User manual

GE
GE b30 Use and care manual

GE
GE Masoneilan 4700E User manual

GE
GE PACSystems* RX3i User manual

GE
GE PACSystems* RX3i User guide

GE
GE ASTAT XT QT 0008U Series User manual

GE
GE PACSystems RX7i User manual
Popular Controllers manuals by other brands

Muller Elektronik
Muller Elektronik SPRAYER-Controller Orchard/Vineyard MIDI 3.0 operating instructions

Verasys
Verasys LC-VAC3000-0 quick start guide

Utilitech
Utilitech XSDP-45168 manual

Abus
Abus WINTECTO One Fitting and operating instructions

Danfoss
Danfoss VLT AutomationDrive FC 300 Design guide

Global American Inc.
Global American Inc. 3308220 user manual