GEM eSyStep 639 AE Series User manual

GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
Motorized diaphragm valve
Operating instructions
EN
TYPE EL
CLASS I
AUGUST 2021
further information
webcode: GW-639

All rights including copyrights or industrial property rights are expressly reserved.
Keep the document for future reference.
© GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG
09.05.2022
www.gemu-group.com2 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)

Contents
1 General information ............................................. 4
1.1 Information .................................................... 4
1.2 Symbols used ................................................ 4
1.3 LED symbols .................................................. 4
1.4 Definition of terms ........................................ 4
1.5 Warning notes ............................................... 4
2 Safety information ............................................... 5
3 Product description ............................................. 5
4 GEMÜ CONEXO .................................................... 6
5 Correct use .......................................................... 6
6 Order data ........................................................... 8
7 Technical data ..................................................... 11
7.8 Behaviour in the event of an error ................ 17
8 Dimensions .......................................................... 18
9 Manufacturer's information .................................. 30
9.1 Delivery .......................................................... 30
9.2 Packaging ...................................................... 30
9.3 Transport ....................................................... 30
9.4 Storage ........................................................... 30
10 Installation in piping ............................................ 30
10.1 Preparing for installation .............................. 30
10.2 Installation position ....................................... 30
10.3 Installation with clamp connections ............ 31
10.4 Installation with butt weld spigots ............... 31
10.5 Installation with threaded sockets ............... 31
10.6 Installation with threaded spigots ................ 31
11 Electrical connection ........................................... 32
12 Specific data IO-Link (pin 6) ................................. 36
12.1 Operation on IO-Link ..................................... 36
12.2 Process data .................................................. 39
12.3 Parameter overview ...................................... 40
12.4 Parameter ...................................................... 44
12.5 Events ............................................................ 58
13 Operation ............................................................. 61
13.1 Initialization ................................................... 61
13.2 Manual override ............................................. 61
14 Inspection and maintenance ................................ 62
15 Troubleshooting .................................................. 65
16 Removal from piping ............................................ 67
17 Disposal .............................................................. 67
18 Returns ................................................................ 67
19 Declaration of Incorporation according to
2006/42/EC (Machinery Directive) ....................... 68
20 Declaration of conformity according to 2014/68/
EU (Pressure Equipment Directive) ...................... 69
21 Declaration of conformity according to 2014/30/
EU (EMC Directive) ............................................... 70
GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
www.gemu-group.com 3 / 71

www.gemu-group.com4 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
1 General information
1 General information
1.1 Information
- The descriptions and instructions apply to the standard ver-
sions. For special versions not described in this document
the basic information contained herein applies in combina-
tion with any additional special documentation.
- Correct installation, operation, maintenance and repair work
ensure faultless operation of the product.
- Should there be any doubts or misunderstandings, the Ger-
man version is the authoritative document.
- Contact us at the address on the last page for staff training
information.
1.2 Symbols used
The following symbols are used in this document:
Symbol Meaning
Tasks to be performed
Response(s) to tasks
– Lists
1.3 LED symbols
The following LED symbols are used in the documentation:
Symbol LED conditions
Off
Lit (on)
Flashing
1.4 Definition of terms
Working medium
The medium that flows through the GEMÜ product.
Diaphragm size
Uniform seat size of GEMÜ diaphragm valves for different
nominal sizes.
1.5 Warning notes
Wherever possible, warning notes are organised according to
the following scheme:
SIGNAL WORD
Type and source of the danger
Possible
symbol for the
specific
danger
Possible consequences of non-observance.
Measures for avoiding danger.
Warning notes are always marked with a signal word and
sometimes also with a symbol for the specific danger.
The following signal words and danger levels are used:
DANGER
Imminent danger!
▶Non-observance can cause death or
severe injury.
WARNING
Potentially dangerous situation!
▶Non-observance can cause death or
severe injury.
CAUTION
Potentially dangerous situation!
▶Non-observance can cause moderate
to light injury.
NOTICE
Potentially dangerous situation!
▶Non-observance can cause damage to
property.
The following symbols for the specific dangers can be used
within a warning note:
Symbol Meaning
Danger of explosion
Corrosive chemicals
Hot plant components!

www.gemu-group.com 5 / 71 GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
2 Safety information
The safety information in this document refers only to an indi-
vidual product. Potentially dangerous conditions can arise in
combination with other plant components, which need to be
considered on the basis of a risk analysis. The operator is re-
sponsible for the production of the risk analysis and for com-
pliance with the resulting precautionary measures and re-
gional safety regulations.
The document contains fundamental safety information that
must be observed during commissioning, operation and main-
tenance. Non-compliance with these instructions may cause:
- Personal hazard due to electrical, mechanical and chemical
effects.
- Hazard to nearby equipment.
- Failure of important functions.
- Hazard to the environment due to the leakage of dangerous
materials.
The safety information does not take into account:
- Unexpected incidents and events, which may occur during
installation, operation and maintenance.
- Local safety regulations which must be adhered to by the
operator and by any additional installation personnel.
Prior to commissioning:
1. Transport and store the product correctly.
2. Do not paint the bolts and plastic parts of the product.
3. Carry out installation and commissioning using trained
personnel.
4. Provide adequate training for installation and operating
personnel.
5. Ensure that the contents of the document have been fully
understood by the responsible personnel.
6. Define the areas of responsibility.
7. Observe the safety data sheets.
8. Observe the safety regulations for the media used.
During operation:
9. Keep this document available at the place of use.
10. Observe the safety information.
11. Operate the product in accordance with this document.
12. Operate the product in accordance with the specifications.
13. Maintain the product correctly.
14. Do not carry out any maintenance work and repairs not de-
scribed in this document without consulting the manufac-
turer first.
In cases of uncertainty:
15. Consult the nearest GEMÜ sales office.
3 Product description
3.1 Construction
1
6
5
3
2
4
7
Item Name Materials
1 Optical position indic-
ator
PA 12
2 Manual override
3 Actuator top with LED
display
Polyamide, 50% glass
fibre
4 Actuator base Polyamide, 50% glass
fibre
5 Electrical connection
6 Diaphragm NBR, FKM, CR, EPDM,
PTFE/EPDM
7 Valve body 1.4408, 1.4435, 1.4539
3 Product description

www.gemu-group.com6 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
4 GEMÜ CONEXO
3.2 LED displays
3.2.1 Status LEDs
LED Colour Function
Standard Inversed 1)
Power/fault green green Operating indica-
tion/
communication
status
red red
Open orange green Process valve in
OPEN position
Error red red Error
Closed green orange Process valve in
CLOSED position
1) Inversed representation of the OPEN and CLOSED LEDs, ad-
justable via IO-Link
3.2.2 LED conditions
Status
process
valve
Power/
fault
Open Error Closed
OPEN posi-
tion
CLOSED po-
sition
Position un-
known
Initialization
Open and Closed flash
alternately
LED conditions
lit (on) flashes off
3.3 Description
The GEMÜ 639 is a motorized 2/2-way diaphragm valve. The
eSyStep electric actuator is available as ON/OFF or with integ-
rated positioner. An integral optical and electrical position in-
dicator is standard. The self-locking actuator holds its posi-
tion in a stable manner when idle and in the event of power
supply failure.
3.4 Function
The product controls or regulates (depending on version) a
flowing medium by being closed or opened by a motorized ac-
tuator.
The product is equipped as standard with a mechanical posi-
tion indicator as well as an electrical position and status indic-
ator.
4 GEMÜ CONEXO
Order without CONEXO
If you have ordered the product without CONEXO functionality,
the RFID chip is used for traceability in the production process
and quality assurance. Expansion to include the CONEXO
functionality at a later date must be coordinated with GEMÜ.
Order with CONEXO
GEMÜ CONEXO must be ordered separately with the ordering
option "CONEXO" (see order data).
For electronic identification purposes, each replaceable com-
ponent contained in the product is equipped with an RFID chip
(1). Where you can find the RFID chip differs from product to
product.
1
1
1
Actuator RFID chip Diaphragm RFID
chip
Valve body RFID
chip
The CONEXO pen helps read out information stored in these
RFID chips. The CONEXO app or CONEXO portal is required to
view this information.
5 Correct use
DANGER
Danger of explosion
▶Risk of death or severe injury.
●Do not use the product in potentially
explosive zones.

www.gemu-group.com 7 / 71 GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
WARNING
Improper use of the product
▶Risk of severe injury or death.
▶Manufacturer liability and guarantee will be void.
●Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The product is designed for installation in piping systems and
for controlling a working medium.
The product is not intended for use in potentially explosive
areas.
●Use the product in accordance with the technical data.
5 Correct use

6 Order data
The order data provide an overview of standard configurations.
Please check the availability before ordering. Other configurations available on request.
Order codes
Note: The PTFE/EPDM diaphragm (code 5M) is
not available in diaphragm size 10.
1 Type Code
Diaphragm valve, electrically operated,
eSyStep
639
2 DN Code
DN 4 4
DN 6 6
DN 8 8
DN 10 10
DN 15 15
DN 20 20
DN 25 25
DN 32 32
DN 40 40
3 Body configuration Code
Tank bottom valve body B
Body configuration code B: Dimensions and designs on
request
2/2-way body D
T body T
Body configuration code T: For dimensions, see T
Valves brochure
4 Connection type Code
Spigot
Spigot DIN 0
Spigot EN 10357 series B,
formerly DIN 11850 series 1
16
Spigot EN 10357 series A (formerly DIN 11850 series
2)/DIN 11866 series A
17
Spigot DIN 11850 series 3 18
Spigot JIS-G 3447 35
Spigot JIS-G 3459 schedule 10s 36
Spigot SMS 3008 37
Spigot BS 4825, part 1 55
Spigot ASME BPE / DIN 11866 series C 59
Spigot ISO 1127/EN 10357 series C/DIN 11866 series B 60
Spigot ANSI/ASME B36.19M schedule 10s 63
Spigot ANSI/ASME B36.19M schedule 5s 64
Spigot ANSI/ASME B36.19M schedule 40s 65
Threaded connection
Threaded socket DIN ISO 228 1
Threaded socket NPT 31
Threaded spigot DIN 11851 6
Cone spigot and union nut DIN 11851 6K
4 Connection type Code
Flange
Flange EN 1092, PN 16, form B,
face-to-face dimension FTF EN 558 series 1, ISO 5752,
basic series 1,
length only for body configuration D
8
Flange ANSI Class 150 RF,
face-to-face dimension FTF MSS SP-88,
length only for body configuration D
38
Flange ANSI Class 125/150 RF,
face-to-face dimension FTF EN 558 series 1, ISO 5752,
basic series 1,
length only for body configuration D
39
Clamp
Clamp ASME BPE,
face-to-face dimension FTF ASME BPE,
length only for body configuration D
80
Clamp DIN 32676 series B,
face-to-face dimension FTF EN 558 series 7,
length only for body configuration D
82
Clamp ASME BPE,
face-to-face dimension FTF EN 558 series 7,
length only for body configuration D
88
Clamp DIN 32676 series A,
face-to-face dimension FTF acc. to EN 558 series 7,
length only for body configuration D
8A
Clamp ISO 2852/SMS 3017,
face-to-face dimension FTF EN 558 series 7,
length only for body configuration D
8E
Clamp DIN 32676 series C,
face-to-face dimension FTF ASME BPE,
length only for body configuration D
8P
Clamp DIN 32676 series C,
face-to-face dimension FTF EN 558 series 7,
length only for body configuration D
8T
5 Valve body material Code
Cast iron material
EN-GJL-250 (GG 25) 8
SG iron material
EN-GJS-400-18-LT (GGG 40.3),
PFA lined
17
EN-GJS-400-18-LT (GGG 40.3),
PP lined
18
EN-GJS-400-18-LT (GGG 40.3),
hard rubber lined
83
EN-GJS-400-18-LT (GGG 40.3) 90
Investment casting material
1.4408, investment casting 37
1.4408, PFA lined 39
1.4435, investment casting C3
Forged material
1.4435 (F316L), forged body 40
6 Order data
www.gemu-group.com8 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)

5 Valve body material Code
1.4435 (BN2), forged body, Δ Fe < 0.5% 42
1.4539, forged body F4
Brass
CW614N, CW617N (brass) 12
6 Diaphragm material Code
Elastomer
NBR 2
FKM 4
CR 8
EPDM 13
EPDM 17
EPDM 19
EPDM 29
EPDM 36
PTFE
PTFE/EPDM one-piece 54
PTFE/EPDM two-piece 5M
Note: The PTFE/EPDM diaphragm (code 5M) is
available from diaphragm size 25.
7 Voltage/Frequency Code
24 V DC C1
8 Control module Code
OPEN/CLOSE control, additional end position indicators AE
OPEN/CLOSE control, additional end position indicators,
configured for emergency power supply module (NC)
A5
OPEN/CLOSE control, additional end position indicators,
configured for emergency power supply module (NO)
A6
9 Surface Code
Ra ≤ 6.3 μm (250 μin.) for media wetted surfaces,
mechanically polished internal
1500
Ra ≤ 0.8 µm (30 µin.) for media wetted surfaces,
in accordance with DIN 11866 H3,
mechanically polished internal
1502
Ra ≤ 0.8 µm (30 µin.) for media wetted surfaces,
in accordance with DIN 11866 HE3,
electropolished internal/external
1503
Ra ≤ 0.6 μm (25 μin.) for media wetted surfaces,
mechanically polished internal
1507
Ra ≤ 0.6 µm (25 µin.) for media wetted surfaces,
electropolished internal/external
1508
Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces,
in accordance with DIN 11866 H4,
mechanically polished internal
1536
Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces,
in accordance with DIN 11866 HE4,
electropolished internal/external
1537
Ra ≤ 0.25 μm (10 µin.) for media wetted surfaces *),
in accordance with DIN 11866 HE5,
electropolished internal/external,
*) for inner pipe diameters < 6 mm, in the spigot Ra ≤
0.38 μm
1516
9 Surface Code
Ra ≤ 0.25 μm (10 µin.) for media wetted surfaces *),
in accordance with DIN 11866 H5,
mechanically polished internal,
*) for inner pipe diameters < 6 mm, in the spigot Ra ≤
0.38 μm
1527
Ra max. 0.51 µm (20 µin.) for media wetted surfaces,
in accordance with ASME BPE SF1,
mechanically polished internal
SF1
Ra max. 0.64 µm (25 µin.) for media wetted surfaces,
in accordance with ASME BPE SF2,
mechanically polished internal
SF2
Ra max. 0.76 µm (30 µin.) for media wetted surfaces,
in accordance with ASME BPE SF3,
mechanically polished internal
SF3
Ra max. 0.38 µm (15 µin.) for media wetted surfaces,
in accordance with ASME BPE SF4,
electropolished internal/external
SF4
Ra max. 0.51 µm (20 µin.) for media wetted surfaces,
in accordance with ASME BPE SF5,
electropolished internal/external
SF5
Ra max. 0.64 µm (25 µin.) for media wetted surfaces,
in accordance with ASME BPE SF6,
electropolished internal/external
SF6
10 Actuator version Code
Actuator size 0 0A
Actuator size 0
diaphragm size 8
0B
Actuator size 1 1A
11 Special version Code
Without
Special version for oxygen,
maximum medium temperature: 60°C
S
12 CONEXO Code
Without
Integrated RFID chip for electronic identification and
traceability
C
6 Order data
www.gemu-group.com 9 / 71 GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)

Order example
Ordering option Code Description
1 Type 639 Diaphragm valve, motorized,
eSyStep
2 DN 15 DN 15
3 Body configuration D 2/2-way body
4 Connection type 60 Spigot ISO 1127/EN 10357 series C/DIN 11866 series B
5 Valve body material 40 1.4435 (F316L), forged body
6 Diaphragm material 54 PTFE/EPDM one-piece
7 Voltage/Frequency C1 24 V DC
8 Control module AE Open/close control with additional
end position feedback
9 Surface 1503 Ra ≤ 0.8 µm (30 µin.) for media wetted surfaces,
in accordance with DIN 11866 HE3,
electropolished internal/external
10 Actuator version 0A Actuator size 0
11 Special version Without
12 CONEXO C Integrated RFID chip for electronic identification and traceability
6 Order data
www.gemu-group.com10 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)

7 Technical data
7.1 Medium
Working medium: Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and
chemical properties of the body and diaphragm material.
For special oxygen version (code S):only gaseous oxygen
7.2 Temperature
Media temperature: Diaphragm material Standard Special version
for oxygen
NBR (Code 2) -10 — 100 °C -
FKM (Code 4) -10 — 90 °C -
CR (Code 8) -10 — 100 °C -
EPDM (Code 13) -10 — 100 °C 0 — 60 °C
EPDM (Code 17) -10 — 100 °C -
EPDM (Code 19) -10 — 100 °C -
EPDM (Code 29) -10 — 100 °C -
EPDM (Code 36) -10 — 100 °C -
PTFE/EPDM (Code 54) -10 — 100 °C -
PTFE/EPDM (Code 5M) -10 — 100 °C -
Sterilization temperature: EPDM (Code 13) max. 150 °C, max. 60 min per cycle
EPDM (Code 17) max. 150 °C, max. 180 min per cycle
EPDM (Code 19) max. 150 °C, max. 180 min per cycle
EPDM (Code 36) max. 150 °C, max. 60 min per cycle
PTFE/EPDM (Code 54) max. 150 °C, permanent temperature per cycle
PTFE/EPDM (Code 5M) max. 150 °C, permanent temperature per cycle
The sterilization temperature is only valid for steam (saturated steam) or superheated water.
If the sterilization temperatures listed above are applied to the EPDM diaphragms for longer periods of time, the
service life of the diaphragms will be reduced. In these cases, maintenance cycles must be adapted accord-
ingly.
PTFE diaphragms can also be used as moisture barriers; however, this will reduce their service life. This also ap-
plies to PTFE diaphragms exposed to high temperature fluctuations. The maintenance cycles must be adapted
accordingly. GEMÜ 555 and 505 globe valves are particularly suitable for use in the area of steam generation
and distribution. The following valve arrangement for interfaces between steam pipes and process pipes has
proven itself over time: A globe valve for shutting off steam pipes and a diaphragm valve as an interface to the
process pipes.
Steam input
Steam distribution Sterile process
Process pipe
Ambient temperature: 0 — 60 °C
GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
www.gemu-group.com 11 / 71
7 Technical data

7.3 Pressure
Operating pressure: MG DN Actuator
version
Diaphragm material
Elastomer PTFE
Forged
material
Cast material
with and without
lining
8 4 - 15 0B 0 - 10 0 - 10 0 - 6
10 10 - 20 0A 0 - 10 0 - 10 0 - 6
25 15 - 25 1A 0 - 8 0 - 8 0 - 6
40 32 - 40 1A 0 - 8 0 - 4 0 - 4
MG = diaphragm size
All pressures are gauge pressures. Operating pressure values were determined with static operat-
ing pressure applied on one side of a closed valve. Sealing at the valve seat and atmospheric seal-
ing is ensured for the given values.
Information on operating pressures applied on both sides and for high purity media on request.
Pressure rating: PN 16
Leakage rate: Leakage rate A to P11/P12 EN 12266-1
Kv values: MG DN Connection type
0 16 17 18 37 59 60 1
8 4 0.5-------
6- - 1.1 - - - 1.2 -
8- - 1.3 - - 0.6 2.2 -
10 - 2.1 2.1 2.1 - 1.3 - -
15 - - - - - 2.0 - -
10 10 - 2.4 2.4 2.4 - 2.2 3.3 -
12 -------3.2
15 3.3 3.8 3.8 3.8 - 2.2 4.0 3.4
20 - - - - - 3.8 - -
25 15 4.1 4.7 4.7 4.7 - - 7.4 6.5
20 6.3 7.0 7.0 7.0 - 4.4 13.2 10.0
25 13.9 15.0 15.0 15.0 12.6 12.2 16.2 14.0
40 32 25.3 27.0 27.0 27.0 26.2 - 30.0 26.0
40 29.3 30.9 30.9 30.9 30.2 29.5 32.8 33.0
MG = diaphragm size, Kv values in m³/h
Kv values determined in accordance with DIN EN 60534 standard, inlet pressure 5 bar, Δp 1 bar, stainless steel
valve body and soft elastomer diaphragm. The Kv values for other product configurations (e.g. other diaphragm
or body materials) may differ. In general, all diaphragms are subject to the influences of pressure, temperature,
the process and their tightening torques. Therefore the Kv values may exceed the tolerance limits of the stand-
ard.
The Kv value curve (Kv value dependent on valve stroke) can vary depending on the diaphragm material and dur-
ation of use.
www.gemu-group.com12 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
7 Technical data

Kv values: MG DN SG iron 40.3 GG 25 PFA / PP Hard rubber
25 15 8.0 7.0 5.0 6.0
20 11.5 14.0 9.0 11.0
25 11.5 20.0 13.0 15.0
40 32 28.0 36.0 23.0 29.0
40 28.0 40.0 26.0 32.0
MG = diaphragm size, Kv values in m³/h
Kv values determined in accordance with DIN EN 60534, inlet pressure 5 bar, Δp 1 bar, with connection flange
EN 1092 length EN 558 series 1 (or threaded socket DIN ISO 228 for body material GGG40.3) and soft elastomer
diaphragm. The Kv values for other product configurations (e.g. other diaphragm or body materials) may differ.
In general, all diaphragms are subject to the influences of pressure, temperature, the process and their tighten-
ing torques. Therefore the Kv values may exceed the tolerance limits of the standard.
The Kv value curve (Kv value dependent on valve stroke) can vary depending on the diaphragm material and dur-
ation of use.
7.4 Product compliance
Machinery Directive: 2006/42/EC
Pressure Equipment Dir-
ective:
2014/68/EU
Food: Regulation (EC) No. 1935/2006
Regulation (EC) No. 10/2011*
FDA*
USP* Class VI
* depending on version and/or operating parameters
EMC Directive: 2014/30/EU
Technical standards used:
Interference emission DIN EN 61000-6-4 (07/2011)
DIN EN 61326-1 (industry) (07/2013)
Interference emission class: Class A
Interference emission group: Group 1
Interference resistance DIN EN 61000-6-2 (03/2006)
DIN EN 61326-1 (industry) (07/2013)
GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
www.gemu-group.com 13 / 71
7 Technical data

7.5 Mechanical data
Protection class: IP 65 acc. to EN 60529
Actuating speed: Max. 3 mm/s
Weight: Actuator
Actuator size 0 (code 0A / 0B) 0.95 kg
Actuator size 1 (code 1A) 1.88 kg
Body
Connection type
code
0, 16,
17, 18,
35, 36,
37, 55,
59, 60,
63, 64,
65
1 1 1, 31 31 6, 6K 8, 38, 39 80, 82,
88, 8A,
8E, 8P,
8T
Valve body Spigot Threaded
socket
Threade
d
spigot
Flange Clamp
Material code 12 37 90 37
MG DN
8 4 0.09-------
60.09-------
80.09 - 0.09 - - - - 0.15
10 0.09 - - - - 0.21 - 0.18
15 0.09 - - - - - - 0.18
10 10 0.30 - - - - 0.33 - 0.30
12 - 0.17 0.17 - - - - -
15 0.30 0.26 0.26 - - 0.35 - 0.43
20 0.30 - - - - - - 0.43
25 15 0.62 - 0.32 0.50 0.32 0.71 1.85 0.75
20 0.58 - 0.34 0.60 0.34 0.78 2.35 0.71
25 0.55 - 0.39 0.90 0.39 0.79 2.85 0.63
40 32 1.45 - 0.88 1.40 0.88 1.66 4.90 1.62
40 1.32 - 0.93 1.90 0.93 1.62 5.65 1.50
MG = diaphragm size, weight in kg
Mechanical environ-
mental conditions:
Class 4M8 acc. to EN 60721-3-4:1998
Vibration: 5g acc. to IEC 60068-2-6 Test Fc
Shock: 25g acc. to 60068-2-27 Test Ea
www.gemu-group.com14 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
7 Technical data

7.6 Duty cycle and service life
Duty cycle: Control module Open/Close control (code AE, A5, A6)
Duty cycle with full valve lift and playing time 10 minutes.
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80
Duty cycle [%]
Ambient temperature [°C]
Diaphragm valve DN 4 - 20 (code 0A / 0B)
Diaphragm valve DN 15 - 25 (code 1A)
Diaphragm valve DN 32 - 40 (code 1A)
NOTICE
▶The specified characteristics and values apply to the factory setting.
▶With reduced forces, higher duty cycles and/or higher ambient temperatures are possible. At higher force settings the duty
cycle and/or ambient temperature is reduced.
▶IO-Link: Index 0x90 - Subindex 2 - Force
GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
www.gemu-group.com 15 / 71
7 Technical data

7.7 Electrical data
Supply voltage Uv: 24 V DC ± 10%
Rating: Actuator size 0 (code 0A, 0B) 20 W
Actuator size 1 (code 1A) 60 W
Operation: Stepper motor, self-locking
Reverse battery protec-
tion:
Yes
7.7.1 Digital input signals
Inputs: Function selectable via IO-Link (see table Overview of available functions – Input and output sig-
nals)
Input voltage: 24 V DC
Logic level "1": > 15.3 V DC
Logic level "0": < 5.8 V DC
Input current: typically < 0.5 mA
7.7.2 Digital output signals
Outputs: Function selectable via IO-Link (see table Overview of available functions – Input and output sig-
nals)
Type of contact: Push-Pull
Switching voltage: Power supply Uv
Switching current: ≤ 140 mA
Short-circuit proof: Yes
7.7.3 Communication
Interface: IO-Link
Function: Parameterization/process data
Transmission rate: 38400 baud
Frame type in Operate: 2.5 (eSyStep ON/OFF, code AE, A5, A6)
Min. cycle time: 2.3 ms (eSyStep ON/OFF, code AE, A5, A6)
Vendor-ID: 401
Device-ID: 1906701 (eSyStep ON/OFF, code AE, A5, A6)
Product-ID: eSyStep On/Off (code AE, A5, A6)
ISDU support: Yes
SIO operation: Yes
IO-Link specification: V1.1
IODD files can be downloaded via https://ioddfinder.io-link.com/ or www.gemu-group.com.
www.gemu-group.com16 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
7 Technical data

7.8 Behaviour in the event of an error
Function: In the event of an error the valve moves to the error position.
Notes: Moving to the error position is only possible with full power supply. This behaviour is not a
safety position. The valve must be operated with a GEMÜ 1571 emergency power supply module
(see accessories) to ensure the function in case of voltage loss.
Error position: Closed, open or hold (adjustable via IO-Link).
GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
www.gemu-group.com 17 / 71
7 Technical data

8 Dimensions
8.1 Actuator dimensions
B2
B1
A
A1
B
CT*
MG DN Actuator
version
A A1 A2 B B1 B2
8 4 - 15 0B 222.5 58.0 33.2 59.4 81.0 133.5
10 10 - 20 0A 237.0 72.5 33.2 59.4 81.0 133.5
25 15 - 25 1A 306.0 124.0 32.5 70.0 82.0 150.0
40 32 - 40 1A 304.0 122.0 32.5 70.0 82.0 150.0
Dimensions in mm
MG = diaphragm size
* CT = A + H1 (see body dimensions)
www.gemu-group.com18 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
8 Dimensions

8.2 Body dimensions
8.2.1 Spigot DIN/EN/ISO (code 0, 16, 17, 18, 60)
L
c
ød
s
H1
Connection type spigot DIN/EN/ISO (code 0, 16, 17, 18, 60) 1), forged material (code 40, 42, F4) 2)
MG DN NPS c (min) ød H1 L s
Connection type Connection type
0 16 17 18 60 0 16 17 18 60
8 4 - 20.0 6.0 - - - - 8.5 72.0 1.0 - - - -
6 - 20.0 - - 8.0 - 10.2 8.5 72.0 - - 1.0 - 1.6
8 1/4" 20.0 - - 10.0 - 13.5 8.5 72.0 - - 1.0 - 1.6
10 3/8" 20.0 - 12.0 13.0 14.0 - 8.5 72.0 - 1.0 1.5 2.0 -
10 10 3/8" 25.0 - 12.0 13.0 14.0 17.2 12.5 108.0 - 1.0 1.5 2.0 1.6
15 1/2" 25.0 18.0 18.0 19.0 20.0 21.3 12.5 108.0 1.5 1.0 1.5 2.0 1.6
25 15 1/2" 25.0 18.0 18.0 19.0 20.0 21.3 19.0 120.0 1.5 1.0 1.5 2.0 1.6
20 3/4" 25.0 22.0 22.0 23.0 24.0 26.9 19.0 120.0 1.5 1.0 1.5 2.0 1.6
25 1" 25.0 28.0 28.0 29.0 30.0 33.7 19.0 120.0 1.5 1.0 1.5 2.0 2.0
40 32 1¼" 25.0 34.0 34.0 35.0 36.0 42.4 26.0 153.0 1.5 1.0 1.5 2.0 2.0
40 1½" 25.0 40.0 40.0 41.0 42.0 48.3 26.0 153.0 1.5 1.0 1.5 2.0 2.0
Connection type spigot DIN/EN/ISO (code 0, 17, 60), investment casting material (code C3)
MG DN NPS c (min) ød H1 L s
Connection type Connection type
0 17 60 0 17 60
8 4 - 20.0 6.0 - - 8.5 72.0 1.0 - -
6 - 20.0 - 8.0 - 8.5 72.0 - 1.0 -
8 1/4" 20.0 - 10.0 13.5 8.5 72.0 - 1.0 1.6
10 3/8" 20.0 - 13.0 - 8.5 72.0 - 1.5 -
10 10 3/8" 25.0 - 13.0 17.2 12.5 108.0 - 1.5 1.6
15 1/2" 25.0 - 19.0 21.3 12.5 108.0 - 1.5 1.6
25 15 1/2" 25.0 - 19.0 21.3 13.0 120.0 - 1.5 1.6
20 3/4" 25.0 - 23.0 26.9 16.0 120.0 - 1.5 1.6
25 1" 25.0 - 29.0 33.7 19.0 120.0 - 1.5 2.0
40 32 1¼" 25.0 - 35.0 42.4 24.0 153.0 - 1.5 2.0
GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
www.gemu-group.com 19 / 71
8 Dimensions

MG DN NPS c (min) ød H1 L s
Connection type Connection type
0 17 60 0 17 60
40 1½" 25.0 - 41.0 48.3 26.0 153.0 - 1.5 2.0
Dimensions in mm
MG = diaphragm size
1) Connection type
Code 0: Spigot DIN
Code 16: Spigot EN 10357 series B, formerly DIN 11850 series 1
Code 17: Spigot EN 10357 series A (formerly DIN 11850 series 2)/DIN 11866 series A
Code 18: Spigot DIN 11850 series 3
Code 60: Spigot ISO 1127/EN 10357 series C/DIN 11866 series B
2) Valve body material
Code 40: 1.4435 (F316L), forged body
Code 42: 1.4435 (BN2), forged body, Δ Fe < 0.5%
Code F4: 1.4539, forged body
www.gemu-group.com20 / 71GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
8 Dimensions
Table of contents
Other GEM Control Unit manuals

GEM
GEM 543 eSyStep User manual

GEM
GEM 740 Assembly instructions

GEM
GEM 332 Assembly instructions

GEM
GEM N086 User guide

GEM
GEM 205 Assembly instructions

GEM
GEM 539 eSyDrive User manual

GEM
GEM R690 Assembly instructions

GEM
GEM R693 Assembly instructions

GEM
GEM 649 eSyDrive User manual

GEM
GEM 650TL User manual
Popular Control Unit manuals by other brands

Sigalarm
Sigalarm GENERATION 5 WIRELESS Installation and operation manual

Trenz Electronic
Trenz Electronic TEF1001 Schematics

Siemens
Siemens SIMATIC NET IE/AS-INTERFACE LINK PN IO manual

Blue Bamboo
Blue Bamboo H50 installation guide

WOMIX
WOMIX MIX M 3-20 Mounting and operating instruction

Xerox
Xerox 4151 Printer Reference