GEM 565 User manual

GEMÜ 565
Pneumatically operated control valve
Operating instructions
EN
further information
webcode: GW-565

All rights including copyrights or industrial property rights are expressly reserved.
Keep the document for future reference.
© GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG
22.05.2023
www.gemu-group.com2 / 20GEMÜ 565

Contents
1 General information ............................................. 4
1.1 Information .................................................... 4
1.2 Symbols used ................................................ 4
1.3 Definition of terms ........................................ 4
1.4 Warning notes ............................................... 4
2 Safety information ............................................... 5
3 Product description ............................................. 5
3.1 Construction .................................................. 5
3.2 Description ..................................................... 5
3.3 Function ......................................................... 5
3.4 Product label ................................................. 5
5 Order data ........................................................... 7
6 Technical data ..................................................... 9
7 Dimensions .......................................................... 11
7.1 Overall dimensions ........................................ 11
7.2 Body dimensions ........................................... 12
7.3 Valve body mounting .................................... 12
8 Manufacturer's information .................................. 13
8.1 Delivery .......................................................... 13
8.2 Packaging ...................................................... 13
8.3 Transport ....................................................... 13
8.4 Storage ........................................................... 13
9 Installation in piping ............................................ 13
9.1 Preparing for installation .............................. 13
9.2 Installation position ....................................... 14
9.3 Installation with threaded sockets ............... 14
9.4 Installation with union ends .......................... 14
9.5 After the installation ...................................... 14
10 Pneumatic connections ....................................... 15
10.1 Control function ............................................. 15
10.2 Connecting the control medium ................... 15
11 Mounting, connecting and setting the positioner .. 15
12 Commissioning .................................................... 15
13 Operation ............................................................. 15
13.1 Control function 1 .......................................... 15
14 Troubleshooting .................................................. 16
15 Inspection and maintenance ................................ 17
15.1 Fitting/removing spare parts ........................ 17
15.2 Spare parts .................................................... 17
15.2.1 Replacing the isolating diaphragm . 17
16 Removal from piping ............................................ 18
17 Disposal .............................................................. 18
18 Returns ................................................................ 18
19 Declaration of Incorporation according to the EC
Machinery Directive 2006/42/EC, Annex II, 1.B .... 19
GEMÜ 565www.gemu-group.com 3 / 20

www.gemu-group.com4 / 20GEMÜ 565
1 General information
1 General information
1.1 Information
- The descriptions and instructions apply to the standard ver-
sions. For special versions not described in this document
the basic information contained herein applies in combina-
tion with any additional special documentation.
- Correct installation, operation, maintenance and repair work
ensure faultless operation of the product.
- Should there be any doubts or misunderstandings, the Ger-
man version is the authoritative document.
- Contact us at the address on the last page for staff training
information.
1.2 Symbols used
The following symbols are used in this document:
Symbol Meaning
Tasks to be performed
Response(s) to tasks
– Lists
1.3 Definition of terms
Working medium
The medium that flows through the GEMÜ product.
Control function
The possible actuation functions of the GEMÜ product.
Control medium
The medium whose increasing or decreasing pressure causes
the GEMÜ product to be actuated and operated.
1.4 Warning notes
Wherever possible, warning notes are organised according to
the following scheme:
SIGNAL WORD
Type and source of the danger
Possible
symbol for the
specific
danger
Possible consequences of non-
observance.
Measures for avoiding danger.
Warning notes are always marked with a signal word and
sometimes also with a symbol for the specific danger.
The following signal words and danger levels are used:
DANGER
Imminent danger!
▶Non-observance can cause death or
severe injury.
WARNING
Potentially dangerous situation!
▶Non-observance can cause death or
severe injury.
CAUTION
Potentially dangerous situation!
▶Non-observance can cause moderate
to light injury.
NOTICE
Potentially dangerous situation!
▶Non-observance can cause damage to
property.
The following symbols for the specific dangers can be used
within a warning note:
Symbol Meaning
Danger - corrosive materials
Danger - hot surfaces

www.gemu-group.com 5 / 20 GEMÜ 565
2 Safety information
The safety information in this document refers only to an indi-
vidual product. Potentially dangerous conditions can arise in
combination with other plant components, which need to be
considered on the basis of a risk analysis. The operator is re-
sponsible for the production of the risk analysis and for com-
pliance with the resulting precautionary measures and re-
gional safety regulations.
The document contains fundamental safety information that
must be observed during commissioning, operation and main-
tenance. Non-compliance with these instructions may cause:
- Personal hazard due to electrical, mechanical and chemical
effects.
- Hazard to nearby equipment.
- Failure of important functions.
- Hazard to the environment due to the leakage of dangerous
substances.
The safety information does not take into account:
- Unexpected incidents and events, which may occur during
installation, operation and maintenance.
- Local safety regulations which must be adhered to by the
operator and by any additional installation personnel.
Prior to commissioning:
1. Transport and store the product correctly.
2. Do not paint the bolts and plastic parts of the product.
3. Carry out installation and commissioning using trained
personnel.
4. Provide adequate training for installation and operating
personnel.
5. Ensure that the contents of the document have been fully
understood by the responsible personnel.
6. Define the areas of responsibility.
7. Observe the safety data sheets.
8. Observe the safety regulations for the media used.
During operation:
9. Keep this document available at the place of use.
10. Observe the safety information.
11. Operate the product in accordance with this document.
12. Operate the product in accordance with the specifications.
13. Maintain the product correctly.
14. Do not carry out any maintenance work and repairs not de-
scribed in this document without consulting the manufac-
turer first.
In cases of uncertainty:
15. Consult the nearest GEMÜ sales office.
3 Product description
3.1 Construction
1
2
3
4
Item Name Materials
1 Optical position indic-
ator
2 Piston actuator Stainless steel
3 Control medium con-
nector
4 Valve body PVC-U, grey / regulating
cone PEEK
PVDF / regulating cone
PEEK
Seat seal FKM, EPDM
3.2 Description
The GEMÜ 565 2/2-way globe control valve has a stainless
steel piston actuator and is pneumatically operated. All actu-
ator parts are made from stainless steel (except seals). It is
available with a Normally Closed control function (NC). PVC-U
and PVDF are available as valve body materials. The control
valve can only be operated with an electro-pneumatic posi-
tioner or process controller. Direct or remote mounting of a
positioner (GEMÜ 1434, 1435, 1436) is required.
3.3 Function
The product is designed for use in piping. It can be closed or
opened by a control medium, which is how it controls the
flow.
3.4 Product label
Design in accordance with order data
Device-specific data
Year of manufacture
Item number Traceability number Consecutive number
- XXXXXXXX|YYYY
3 Product description

www.gemu-group.com6 / 20GEMÜ 565
4 Correct use
The month of manufacture is encoded in the traceability num-
ber and can be obtained from GEMÜ. The product was manu-
factured in Germany.
4 Correct use
DANGER
Danger of explosion!
▶Risk of death or severe injury
●Do not use the product in potentially
explosive zones.
WARNING
Improper use of the product!
▶Risk of severe injury or death
▶Manufacturer liability and guarantee will be void
●Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The product is designed for installation in piping systems and
for controlling a working medium.
The product is not intended for use in potentially explosive
areas.
●Use the product in accordance with the technical data.

5 Order data
The order data provide an overview of standard configurations.
Please check the availability before ordering. Other configurations available on request.
Order codes
1 Type Code
Control valve, pneumatically operated 565
2 DN Code
DN 3 3
DN 6 6
DN 10 10
DN 15 15
3 Body configuration Code
2/2-way body D
4 Connection type Code
Threaded socket DIN ISO 228 1
Union end with insert (socket) – DIN 7
5 Valve body material Code
PVC-U, grey / regulating cone PEEK 1
PVDF / regulating cone PEEK 20
6 Seal material Code
FKM 4
EPDM 19
7 Control function Code
Normally closed (NC) 1
8 Actuator version Code
Actuator size 1T2 1T2
Actuator size 1T3 1T3
9 Control characteristic Code
Assignment (see “Kv value diagrams“, page10)
Regulating cone, equal-percentage A
Regulating cone, equal-percentage B
Regulating cone, equal-percentage C
Regulating cone, linear D
Regulating cone, linear E
10 Kv value Code
Assignment (see “Kv value diagrams“, page10)
63 l/h 63
100 l/h 100
160 l/h 160
250 l/h 250
400 l/h 400
630 l/h 630
1000 l/h 1000
1600 l/h 1600
2500 l/h 2500
3300 l/h 3300
Order example
Ordering option Code Description
1 Type 565 Control valve, pneumatically operated
2 DN 6 DN 6
3 Body configuration D 2/2-way body
4 Connection type 1 Threaded socket DIN ISO 228
5 Valve body material 1 PVC-U, grey / regulating cone PEEK
6 Seal material 19 EPDM
7 Control function 1 Normally closed (NC)
8 Actuator version 1T2 Actuator size 1T2
9 Control characteristic B Regulating cone, equal-percentage
10 Kv value 400 400 l/h
5 Order data
www.gemu-group.com 7 / 20 GEMÜ 565

www.gemu-group.com8 / 20GEMÜ 565
5 Order data
In order to configure a complete control valve the pneumatically operated basic valve must be paired with an electro-pneumatic
positioner. The GEMÜ 1434, 1435 and 1436 positioners and process controllers can be used for this purpose.
You will find below two configuration examples of a complete valve.
Configuration example for a GEMÜ 565 control valve with
directly mounted GEMÜ 1434 positioner
GEMÜ type Order key
GEMÜ 565 565 15 D 1 1 19 1T3 A 250
GEMÜ 1434 positioner 1434 000 Z 1 A 14 1 00 01
010
Mounting kit for direct mount-
ing of positioner
1434S01Z0342010
GEMÜ 1219 cable plug M12 1219 000 Z 00 00DG 00M0
M125 A
Configuration example for a GEMÜ 565 control valve with
remotely mounted GEMÜ 1434 positioner
GEMÜ type Order key
GEMÜ 565 565 15 D 1 1 19 1T3 A 250
GEMÜ 1434 positioner 1434 000 Z 1 A 14 1 00 01
010
Travel sensor for remote
mounting
4232 000 Z 14 030 02M0
0000
Mounting kit for remote
mounting
GEMÜ 1219 cable plug M12
4232 S01 Z 292403000
1219 000 Z 00 00DG 00M0
M125 A

6 Technical data
6.1 Medium
Working medium: Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and
chemical properties of the body and seal material.
Control medium: Inert gases
6.2 Temperature
Media temperature: -20 — 80 °C
Observe pressure/temperature diagram
Control medium temper-
ature:
0 — 70 °C
Ambient temperature: -15 — 55 °C
Storage temperature: 0 — 40 °C
6.3 Pressure
Operating pressure: 0 — 6 bar
All pressures are gauge pressures.
Control pressure: 3 to 7 bar
for actuator size 1T2
Pressure/temperature
correlation:
Valve body material Temperature in °C (valve body)
Materials Code -20 -10 ±0 5 10 20 25 30 40 50 60 70 80
PVC-U 1 - - - - 6.0 6.0 6.0 6.0 6.0 3.5 1.5 - -
PVDF 20 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 5.4 4.7
Permissible operating pressure in bar
The pressure rating (PN) depends on the connection code.
Data for extended temperature ranges on request. Please note that the ambient temperature and media temper-
ature generate a combined temperature at the valve body which must not exceed the above values.
Filling volume: 0.031 dm³
Leakage rate: Control valve
Seat seal Standard Test procedure Leakage rate Test medium
FKM, PTFE DIN EN 60534-4 1 VI Air
GEMÜ 565www.gemu-group.com 9 / 20
6 Technical data

Kv values:
160
140
120
100
80
60
40
20
0012345
A
DCB
Control characteristic
DN 3
Stroke [mm]
Kvs value [l/h]
012345
800
700
600
500
400
300
200
100
0
A
D
C
B
E
Control characteristic
DN 6
Stroke [mm]
Kvs value [l/h]
012345
1600
1400
1200
1000
800
600
400
200
0
A
D
B
Control characteristic
DN 10
Stroke [mm]
Kvs value [l/h]
012345
4000
3500
3000
2500
2000
1500
1000
500
0
A
D
B
Control characteristic
DN 15
Stroke [mm]
Kvs value [l/h]
DN Control characteristic (code)
Seat Ø [mm] A B C D E
363.0 100.0 160.0 100.0 -
6250.0 400.0 630.0 250.0 630.0
10 1000.0 1600.0 - 1600.0 -
15 2500.0 3300.0 - 3300.0 -
Kv values in l/h
Tolerance ± 10 %
www.gemu-group.com10 / 20GEMÜ 565
6 Technical data

6.4 Product compliance
Machinery Directive: 2006/42/EC
EAC: TR CU 010/2011
TR CU 004/2011
6.5 Mechanical data
Weight: 1.50 kg
7 Dimensions
7.1 Overall dimensions
70
61
M
16
x1
G 1/4
177
111
99,5
Travel sensor for remote mounting to
positioners or process controllers
Ø 70.0
177.0
111.0
G 1/4
M16x1
Ø 61.0
99.5
Dimensions in mm
GEMÜ 565www.gemu-group.com 11 / 20
7 Dimensions

7.2 Body dimensions
7.2.1 Threaded socket - DIN ISO 228 (code 1)
16
15
G
67
DN (seat) G
3G 3/8
6G 3/8
10 G 3/8
15 G 1/2
Dimensions in mm
7.2.2 Union end with insert (socket) - DIN (code 7)
ød
LB
15
LA
ØD
G
DN G ØD ød LA LB
3G 3/4 35.0 16.0 130.0 164.0
6G 3/4 35.0 16.0 130.0 164.0
10 G 3/4 35.0 16.0 130.0 164.0
15 G 1 43.0 20.0 130.0 168.0
Dimensions in mm
7.3 Valve body mounting
40
M5
Dimensions in mm
www.gemu-group.com12 / 20GEMÜ 565
7 Dimensions

www.gemu-group.com 13 / 20 GEMÜ 565
8 Manufacturer's information
8.1 Delivery
●Check that all parts are present and check for any damage
immediately upon receipt.
The product's performance is tested at the factory. The scope
of delivery is apparent from the dispatch documents and the
design from the order number.
Control
function
Function Condition as supplied
to customer
1 Normally closed (NC) closed
8.2 Packaging
The product is packaged in a cardboard box which can be re-
cycled as paper.
8.3 Transport
1. Only transport the product by suitable means. Do not drop.
Handle carefully.
2. After the installation dispose of transport packaging ma-
terial according to relevant local or national disposal regu-
lations / environmental protection laws.
8.4 Storage
1. Store the product free from dust and moisture in its ori-
ginal packaging.
2. Avoid UV rays and direct sunlight.
3. Do not exceed the maximum storage temperature (see
chapter "Technical data").
4. Do not store solvents, chemicals, acids, fuels or similar
fluids in the same room as GEMÜ products and their spare
parts.
9 Installation in piping
9.1 Preparing for installation
WARNING
The equipment is subject to pressure!
▶Risk of severe injury or death
●Depressurize the plant.
●Completely drain the plant.
WARNING
Corrosive chemicals!
▶Risk of caustic burns
●Wear appropriate protective gear.
●Completely drain the plant.
CAUTION
Hot plant components!
▶Risk of burns
●Only work on plant that has cooled
down.
CAUTION
Leakage
▶Emission of dangerous materials.
●Provide precautionary measures against exceeding the
maximum permitted pressures caused by pressure
surges (water hammer).
CAUTION
Exceeding the maximum permissible pressure.
▶Damage to the product
●Provide precautionary measures against exceeding the
maximum permitted pressures caused by pressure
surges (water hammer).
CAUTION
Use as step.
▶Damage to the product
▶Risk of slipping-off
●Choose the installation location so that the product can-
not be used as a foothold.
●Do not use the product as a step or a foothold.
NOTICE
Suitability of the product!
▶The product must be appropriate for the piping system
operating conditions (medium, medium concentration,
temperature and pressure) and the prevailing ambient
conditions.
9 Installation in piping

www.gemu-group.com14 / 20GEMÜ 565
9 Installation in piping
NOTICE
Tools
▶The tools required for installation and assembly are not
included in the scope of delivery.
●Use appropriate, functional and safe tools.
1. Ensure the product is suitable for the relevant application.
2. Check the technical data of the product and the materials.
3. Keep appropriate tools ready.
4. Wear appropriate protective gear, as specified in the plant
operator's guidelines.
5. Observe appropriate regulations for connections.
6. Have installation work carried out by trained personnel.
7. Shut off plant or plant component.
8. Secure plant or plant component against recommission-
ing.
9. Depressurize the plant or plant component.
10. Completely drain the plant (or plant component) and let it
cool down until the temperature is below the media vapor-
ization temperature and cannot cause scalding.
11. Correctly decontaminate, rinse and ventilate the plant or
plant component.
12. Lay piping so that the product is protected against trans-
verse and bending forces, and also from vibrations and
tension.
13. Only install the product between matching aligned pipes
(see chapters below).
14. Please note the flow direction (see chapter "Flow direc-
tion").
15. Please note the installation position (see chapter "Installa-
tion position").
9.2 Installation position
The installation position of the product is optional.
9.3 Installation with threaded sockets
Fig.1: Threaded socket
NOTICE
Sealing material
▶The sealing material is not included in the scope of deliv-
ery.
●Only use appropriate sealing material.
1. Keep thread sealant ready.
2. Carry out preparations for installation (see chapter "Pre-
paring for installation").
3. Screw the threaded connections into the pipe in accord-
ance with valid standards.
4. Screw the body of the product onto the piping using ap-
propriate thread sealant.
5. Re-attach or reactivate all safety and protective devices.
9.4 Installation with union ends
Fig.2: Union end with insert
NOTICE
▶The solvent cement is not included in the scope of deliv-
ery.
●Only use suitable solvent cement!
1. Carry out preparations for installation (see chapter "Pre-
parations for installation").
2. Depending on the application, comply with the welding
standards and the specifications of the solvent cement
manufacturer for adhesive bonds.
3. Screw the threaded connections into the piping in accord-
ance with valid standards.
4. Unscrew the union nut from the body of the product.
5. Reinsert the O-ring if necessary.
6. Push the union nut over the piping.
7. Connect the insert with the piping by solvent cementing/
welding.
8. Screw the union nut back onto the body of the product.
9. Connect the other side of the body of the product with the
piping in the same way.
10. Reactivate all safety and protective devices.
9.5 After the installation
●Re-attach or reactivate all safety and protective devices.

www.gemu-group.com 15 / 20 GEMÜ 565
10 Pneumatic connections
10.1 Control function
The following control function is available:
Control function 1
Normally closed (NC):
Valve resting position: closed by spring force. Activation of
the actuator (connector 2) opens the valve. When the actuator
is vented, the valve is closed by spring force.
Connector 2
10.2 Connecting the control medium
1. Use suitable connectors.
2. Connect the control medium lines tension-free and
without any bends or knots.
Thread size of the control medium connector: G1/4
Control function Connectors
1 Normally closed (NC) 2: Control medium (open)
For connector 2 see figure above
11 Mounting, connecting and setting the positioner
See positioner operating instructions.
12 Commissioning
WARNING
Corrosive chemicals!
▶Risk of caustic burns
●Wear appropriate protective gear.
●Completely drain the plant.
CAUTION
Leakage
▶Emission of dangerous materials.
●Provide precautionary measures against exceeding the
maximum permitted pressures caused by pressure
surges (water hammer).
CAUTION
Cleaning agent
▶Damage to the GEMÜ product.
●The plant operator is responsible for selecting the clean-
ing material and performing the procedure.
1. Check the tightness and the function of the product (close
and reopen the product).
2. Flush the piping system of new plant and following repair
work (the product must be fully open).
ðHarmful foreign matter has been removed.
ðThe product is ready for use.
3. Commission the product.
4. Commissioning of actuators in accordance with the en-
closed instructions.
13 Operation
The flow direction is indicated by an arrow on an adhesive la-
bel on the valve body:
+60 °C0-6 bar
Operate the product according to the control function (see
also chapter "Pneumatic connections").
13.1 Control function 1
In its resting position, the product is closed by spring force.
1. Activate the actuator via control medium connector 2.
ðThe product opens.
2. Vent the actuator via control medium connector 2.
ðThe product closes.
13 Operation

www.gemu-group.com16 / 20GEMÜ 565
14 Troubleshooting
14 Troubleshooting
Error Error cause Troubleshooting
Control medium escaping from vent and
leak detection hole
Actuator* faulty Check control medium for impurities,
send the product to GEMÜ for repair if ne-
cessary
Working medium escaping from vent and
leak detection hole
Isolating diaphragm* faulty Send the product to GEMÜ for repair
The product does not open or does not
open fully
Control pressure too low (for control
function NC)
Operate the product with the control pres-
sure specified in the datasheet
Control medium not connected Connect control medium
Actuator* faulty Send the product to GEMÜ for repair and
check the control medium for impurities
Positioner faulty Replace positioner
Positioner not connected Connect positioner
The product is leaking downstream (does
not close or does not close fully)
Operating pressure too high Operate the product with operating pres-
sure specified in datasheet
Foreign matter between regulating cone
and seat
Send valve to GEMÜ for repair
Valve body leaking or damaged Send valve to GEMÜ for repair
Regulating cone damaged Send valve to GEMÜ for repair
Actuator defective Send valve to GEMÜ for repair
The product is leaking between actuator
and valve body
Union nut loose Retighten union nut
Isolating diaphragm faulty Send valve to GEMÜ for repair
Valve body / actuator damaged Send valve to GEMÜ for repair
Connection between valve body and pip-
ing leaking
Incorrect installation Check installation of valve body in piping
Threaded connections / unions loose Tighten threaded connections / unions
Sealing material faulty Replace sealing material
Valve body connection to piping is leak-
ing
Gasket faulty Replace gasket
Valve body leaking Valve body leaking or corroded Check valve body for damage, send valve
to GEMÜ for repair if necessary
* see chapter "Spare parts"

www.gemu-group.com 17 / 20 GEMÜ 565
15 Inspection and maintenance
WARNING
The equipment is subject to pressure!
▶Risk of severe injury or death
●Depressurize the plant.
●Completely drain the plant.
CAUTION
Hot plant components!
▶Risk of burns
●Only work on plant that has cooled
down.
The operator must carry out regular visual examination of the
GEMÜ products depending on the operating conditions and
the potential danger in order to prevent leakage and damage.
1. Have servicing and maintenance work performed by
trained personnel.
2. Wear appropriate protective gear as specified in the plant
operator's guidelines.
3. Shut off plant or plant component.
4. Secure the plant or plant component against recommis-
sioning.
5. Depressurize the plant or plant component.
15.1 Fitting/removing spare parts
CAUTION
Do not dismantle the product!
▶Non-observance can cause damage to the product.
●Send the complete product to GEMÜ.
●Observe the chapter "Returns".
NOTICE
The product can only be repaired at GEMÜ.
▶If this procedure is not observed, the purchaser's guaran-
tee rights and the manufacturer's legal liability cease.
This can also lead to a loss of all rights to claim dam-
ages.
●The replacement of spare parts may only be carried out
by GEMÜ (exception: Isolating diaphragm).
●Remove the complete product from the plant using suit-
able means and send it to GEMÜ.
15.2 Spare parts
A
2
Item Designation
A Actuator
2 Isolating diaphragm
15.2.1 Replacing the isolating diaphragm
1. Move the actuator A to the open position.
A
2. Undo union nut 3 of valve body 4.
A
4
3
15 Inspection and maintenance

www.gemu-group.com18 / 20GEMÜ 565
16 Removal from piping
3. Remove valve body 4.
A
4
3
4. Dismantle regulating cone 5, isolating diaphragm 2 and
washer 6 from the valve.
A
2
3
6
5
5. Check parts for potential damage.
6. Replace the isolating diaphragm 2.
7. Reassemble the parts in reverse order (tightening regulat-
ing cone 5, isolating diaphragm 2 and washer 6 until they
are hand tight).
16 Removal from piping
1. Remove in reverse order to installation.
2. Deactivate the control medium.
3. Disconnect the control medium line(s).
4. Disassemble the product. Observe warning notes and
safety information.
17 Disposal
1. Pay attention to adhered residual material and gas diffu-
sion from penetrated media.
2. Dispose of all parts in accordance with the disposal regu-
lations/environmental protection laws.
18 Returns
Legal regulations for the protection of the environment and
personnel require that the completed and signed return deliv-
ery note is included with the dispatch documents. Returned
goods can be processed only when this note is completed. If
no return delivery note is included with the product, GEMÜ
cannot process credits or repair work but will dispose of the
goods at the operator's expense.
1. Clean the product.
2. Request a return delivery note from GEMÜ.
3. Complete the return delivery note.
4. Send the product with a completed return delivery note to
GEMÜ.

www.gemu-group.com 19 / 20 GEMÜ 565
19 Declaration of Incorporation according to the EC Machinery Directive 2006/42/EC, Annex II, 1.B
31 / 32 565
22 Declaration of incorporation
Declaration of Incorporation
according to the EC Machinery Directive 2006/42/EC, Annex II, 1.B
for partly completed machinery
Manufacturer: GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG
Postfach 30
Fritz-Müller-Straße 6-8
D-74653 Ingelfingen-Criesbach
Description and identification of the partly completed machinery:
Make: GEMÜ Globe valve, pneumatically operated
Serial number: from December 29, 2009
Project number: SV-Pneum-2009-12
Commercial name: Type 565
We hereby declare that the following essential requirements of the Machinery Directive 2006/42/EC
have been fulfilled:
1.1.3.; 1.1.5.; 1.1.7.; 1.2.1.; 1.3.; 1.3.2.; 1.3.3.; 1.3.4.; 1.3.7.; 1.3.9.; 1.5.3.; 1.5.5.; 1.5.6.; 1.5.7.; 1.5.8.; 1.5.9.;
1.6.5.; 2.1.1.; 3.2.1.; 3.2.2.; 3.3.2.; 3.4.4.; 3.6.3.1.; 4.1.2.1.; 4.1.2.3.; 4.1.2.4.; 4.1.2.5.; 4.1.2.6. a); 4.1.2.6. b);
4.1.2.6. c); 4.1.2.6. d); 4.1.2.6. e); 4.1.3.; 4.2.1.; 4.2.1.4.; 4.2.2.; 4.2.3.; 4.3.1.; 4.3.2.; 4.3.3.; 4.4.1.; 4.4.2.;
5.3.; 5.4.; 6.1.1.; 6.3.3.; 6.4.1.; 6.4.3.
We also declare that the specific technical documentation has been compiled in accordance with
part B of Annex VII.
We expressly declare that the partly completed machinery complies with the relevant provisions
of the following EC directives:
2006/42/EC:2006-05-17: (Machinery Directive) Directive 2006/42/EC of the European Parliament and of
the Council of 17 May 2006 on machinery, and amending Directive 95/16/EC
(recast) (1)
The manufacturer or his authorised representative undertake to transmit, in response to a reasoned request
by the national authorities, relevant information on the partly completed machinery. This transmission takes
place:
electronically
This does not affect the intellectual property rights!
Important note! The partly completed machinery may be put into service only if it was determined,
where appropriate, that the machinery into which the partly completed machinery is to be instal-
led meets the provisions of this Directive.
Joachim Brien
Head of Technical Department
Ingelfingen-Criesbach, February 2013
19 Declaration of Incorporation according to the EC Machinery Directive 2006/42/EC, Annex II, 1.B

GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG
Fritz-Müller-Straße 6-8, 74653 Ingelfingen-Criesbach, Germany
Phone +49 (0) 7940 1230 · [email protected]
www.gemu-group.com
Subject to alteration
05.2023 | 88866194
Other manuals for 565
1
Table of contents
Other GEM Control Unit manuals
Popular Control Unit manuals by other brands

Nice
Nice MC824HHS Instructions and warnings for installation and use

powersoft
powersoft DigiMod 500 Service manual

Pixelfly
Pixelfly NEX-MC10 quick start guide

ActronAir
ActronAir LC7-2W installation instructions

Siemens
Siemens RUGGEDCOM ROS user guide

Honeywell
Honeywell 010690.02 Mounting and Connection Instructions

KERAFLO
KERAFLO TANKTRONIC installation guide

CTC Union
CTC Union Expansion EnergyFlex Installation and maintenance manual

CAB
CAB CL.FWS operating instructions

Flame
Flame mMCLK manual

NPI
NPI GIA-05X Operating instructions and system description

Emerson
Emerson Keystone K-Lok 360 Series Installation, Operation, Maintenance and Troubleshooting