3
Follow these steps to install the convergence meter;
1. Attach the turnbuckle assembly to the convergence meter by screwing in the left-hand
threaded portion. Use thread locking cement and tighten the lock nut. Set the turnbuckle
such that about 10-12 mm (0.5") of thread is inside from each end.
2. Measure the total distance from anchor eyebolt to anchor eyebolt, inside to inside at the
points where they will touch the convergence meter eyehooks.
3. Check and confirm the convergence meter length against the length shown in the table
below. (The measurement is made from inside the eyehooks, at the point where they touch
the anchor eyebolts, to the end of the Swagelok fitting. To calculate the rod length that will
be needed, subtract the convergence meter length from the anchor eyebolt to anchor
eyebolt distance, now add 30mm (1.2”) to account for the distance the rod penetrates the
Swagelok fittings, This is the nominal rod length that will be required.
Range: 12 mm
0.50
inches
25 mm
1 inch 50 mm
2 inches 100 mm
4 inches 150 mm
6 inches
Convergence Meter
Length including
Swagelok eyehook
assembly:
710 mm
28"
710 mm
28"
865 mm
34"
1195 mm
47"
1615 mm
63.5"
4. Next, the connecting rods must be assembled. This is achieved using the Swagelok
fittings supplied with the instrument and the appropriate wrenches. Appendix C details
additional fitting assembly instructions.
Connect the first length of connecting rod to the sensor using the Swagelok fitting. Push
the rod into the fitting until it hits the stop. Tighten the nut 1½ turns, holding the body with
one wrench while tightening the nut with the other. Connect the second and successive
rods using the Swagelok fittings as described above.
5. Connect the Swagelok eyehook to one end of the rods and the convergence meter to the
other.
6. Hook the eyehook end into the installed eyebolt first.
7. Now, hook the convergence meter into the other eyebolt. It should go in without having to
extend the convergence meter spring. Remember that if the spring is extended beyond
the range of the transducer the transducer could be damaged.
8. Connect the readout box. To set the transducer to mid-range, rotate the turnbuckle until a
reading of approximately 5500 digits is obtained. To use the total range in convergence,
set the meter at 8000. To use the total range in extension, set the meter at 2500.
9. Tighten the locknuts on the turnbuckle. The installation is now complete.
10. To remove the system, loosen the turnbuckle all the way and then remove the
convergence meter. Disconnect the Swagelok fittings on the rods and disassemble the
rods to a manageable length. If the rod string needs to be lengthened (or shortened) for
the next installation, cut off the ferrules and reinstall new ferrules for the next installation.