Control device LEDOTRON
Order No. : 2290 00
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Control unit
(2) Frame
(3) Central plate
(4) Control button
(5) Screw terminals
3 Function
Intended use
- Switching and dimming of Ledotron lamps
- Switching incandescent lamps
- Installation in appliance box according to DIN 49073
Product characteristics
- Ledotron is a digital communication standard for switching and dimming lamps
- Electronic short-circuit protection with permanent switch-off after 100 milliseconds
- Electronic over-temperature protection
- Changeover switch possible in combination with two dimmers
1/4
32577822 14.07.2014
Control device LEDOTRON
10499280 I01
iOnly limited function, or no function at all, will be possible if non-Ledotron lamps are
connected. No device defects or hazards arise.
4 Operation
Switch light
oPress the control button.
Adjust the brightness
Light is switched on.
oTurn the control button in the clockwise direction.
The light gets brighter up to maximum brightness.
oTurn the control button in the anti-clockwise direction.
Light gets darker to minimum brightness.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Connecting and mounting the control unit.
Figure 2: Connection diagram
iConnect 600 Watt HV LED lamps or compact fluorescent lamps at most per 16 ampere
circuit breaker.
oConnect control unit (1) and lamp (6) according to connection diagram (Figure 2).
oInstall the control unit in the appliance box.
oAttach the frame and the central plate.
oAttach the control button.
32577822 10499280 I01 14.07.2014 2/4
Control device LEDOTRON
Connection in changeover switch
iNo changeover switch possible with two control units.
Figure 3: Changeover switch
oConnect the control unit (1), changeover switch (7) and lamp (6) according to the
connection diagram (Figure 3).
6 Appendix
6.1 Technical data
Rated voltage AC 230 V ~
Mains frequency 50 / 60 Hz
Ambient temperature +5 ... +35 °C
Contact type µ
Connected load
Ledotron lamps 3 ... 200 W
Incandescent lamps 60 ... 210 W
Number of Ledotron lamps 1 ... 25
Connection
single stranded 0.5 ... 2.5 mm²
finely stranded without conductor sleeve 0.34 ... 4 mm²
Finely stranded with conductor sleeve 0.14 ... 2.5 mm²
Total length power cable max. 100 m
This icon identifies all devices in the Ledotron system.
6.2 Troubleshooting
Control unit does not switch on.
Incorrect load connected.
Connect a Ledotron lamp or an incandescent lamp.
The control unit switches the load off and cannot be switched on again.
Short-circuit protection has tripped.
Eliminate short-circuit.
When the short circuit has been eliminated, switch the control unit back on by pressing the
control knob twice.
32577822 10499280 I01 14.07.2014 3/4
Control device LEDOTRON
iShort-circuit protection is not based on a conventional fuse, no metallic separation of the
operational current.
Overheating protection has tripped.
Disconnect the control unit from the mains supply. Let the control unit cool down for
approx. 15 minutes.
Check the installation situation.
Reduce the connected load.
Switch circuit breakers and control unit on again.
6.3 Accessories
Information regarding suitable Ledotron lamps can be found on our website.
6.4 Warranty
The warranty is provided in accordance with statutory requirements via the specialist trade.
Please submit or send faulty devices postage paid together with an error description to your
responsible salesperson (specialist trade/installation company/electrical specialist trade). They
will forward the devices to the Gira Service Center.
Gira
Giersiepen GmbH & Co. KG
Elektro-Installations-
Systeme
Industriegebiet Mermbach
Dahlienstraße
42477 Radevormwald
Postfach 12 20
42461 Radevormwald
Deutschland
Tel +49(0)21 95 - 602-0
Fax +49(0)21 95 - 602-191
www.gira.de
[email protected]
32577822 10499280 I01 14.07.2014 4/4
Control device LEDOTRON

This manual suits for next models

1

Other Gira Control Unit manuals

Gira Dual 2347 00 User manual

Gira

Gira Dual 2347 00 User manual

Gira 0644 Series User manual

Gira

Gira 0644 Series User manual

Gira System 3000 User manual

Gira

Gira System 3000 User manual

Gira System 3000 User manual

Gira

Gira System 3000 User manual

Gira 1283 00 User manual

Gira

Gira 1283 00 User manual

Gira 1019 00 User manual

Gira

Gira 1019 00 User manual

Gira eNet User manual

Gira

Gira eNet User manual

Gira System 106 Fingerprint Module 5551 User manual

Gira

Gira System 106 Fingerprint Module 5551 User manual

Gira 5204 00 User manual

Gira

Gira 5204 00 User manual

Gira 5201 00 User manual

Gira

Gira 5201 00 User manual

Gira 1345 26 User manual

Gira

Gira 1345 26 User manual

Gira 5567 000 User manual

Gira

Gira 5567 000 User manual

Gira System 3000 User manual

Gira

Gira System 3000 User manual

Gira DALI  5422 00 User manual

Gira

Gira DALI 5422 00 User manual

Popular Control Unit manuals by other brands

schmersal SLB 400-C operating instructions

schmersal

schmersal SLB 400-C operating instructions

Nordost SORT FÜT instruction manual

Nordost

Nordost SORT FÜT instruction manual

Videx Vandal Resistant 4000 Series manual

Videx

Videx Vandal Resistant 4000 Series manual

Test Equipment Depot Skutch CK-2 quick start guide

Test Equipment Depot

Test Equipment Depot Skutch CK-2 quick start guide

Hanwha Vision SPA-D2000 quick guide

Hanwha Vision

Hanwha Vision SPA-D2000 quick guide

Viessmann Vivotronic 050 HK1S Installation and service instructions

Viessmann

Viessmann Vivotronic 050 HK1S Installation and service instructions

GRASS VALLEY KAMELEON Series instruction manual

GRASS VALLEY

GRASS VALLEY KAMELEON Series instruction manual

ASIX AX58200 user guide

ASIX

ASIX AX58200 user guide

DMP Electronics 734INT Installation and programming guide

DMP Electronics

DMP Electronics 734INT Installation and programming guide

Armstrong DRV40 manual

Armstrong

Armstrong DRV40 manual

Emerson PACSystems RX3i quick start guide

Emerson

Emerson PACSystems RX3i quick start guide

Blonder tongue DAP Series instruction manual

Blonder tongue

Blonder tongue DAP Series instruction manual

CALEFFI ThermoBloc 281 Series manual

CALEFFI

CALEFFI ThermoBloc 281 Series manual

Johnson Controls UL Listed GS-20 Series manual

Johnson Controls

Johnson Controls UL Listed GS-20 Series manual

Espa ESAL Base user guide

Espa

Espa ESAL Base user guide

TQ MBa6ULxL user manual

TQ

TQ MBa6ULxL user manual

Aritech ATS7200 quick start guide

Aritech

Aritech ATS7200 quick start guide

Huawei ME906V user manual

Huawei

Huawei ME906V user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.