5
Installation
ART 7W/G2+ MONITOR
Installation terminals (K)
For ease of installation, the installation terminals are removable and supplied in a separate bag. Once the
terminals are wired, place them in position.
BUS BUS, : communications bus (non-polarised).
24V, : local power input.GND
SA GND, : auxiliary call repeater output (maximum 50mA/12V).
HZ HZ, : apartment front door button input:
Note: ART 7W/G2+ monitor 'V.01 + No. 6539 and V.02' or later: Connect
only on the master monitor. The signal received is then transmitted to the
slave monitors in the same apartment through the BUS.
Configuration switches ( )J
Avoid dusty or smoky environments or locations near sources of heat.
For proper installation, use the template supplied with the product.
1. Position the top of the template at a height of 1.65m.
2. If you are going to use an embedding box to pass the wiring through, make sure that it is in line with the holes
corresponding to the box model chosen and fix the connector. If you prefer to fix the connector directly to the
wall, make four 6mm holes at the points indicated (A), insert the wall plugs supplied and screw in the connector.
3. Pass the installation wires through the middle hole and connect them to the removable terminals as shown in the
wiring diagrams. Before connecting the removable terminals to the monitor, configure the switch as indicated
below.
4. Connect the removable terminals to the monitor and place the monitor in front of the connector, making sure the
fixings line up. Move the monitor downwards to secure it.
ART MONITOR7W/G2+
Note: HZ push button function mode (ART 7W/G2+ monitor "V.0 or later):5" When HZ push button is pressed will
be call tone and activate the output of auxiliary call repeater with standby monitor, call process, communication
process (HZ tone with lower audio level), intercom process and "Do not disturb" mode. Important: Up to monitors/6
apartments with push button "HZ" activated at the same time (with system and monitors in standby).
Building / Villa (Nexa Door Panel)
Switches 6 and 7: These define whether the monitor is master or slave. Each apartment must have one master
monitor, and only one.
Master Slave 1 Slave 2 Slave 3
Switch 8: This activates the end-of-line resistance in the ON position.Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
ART7W/G2+ monitor with V.06 and previous (addresses 1 to 32):
Switches 1 to 5: Sets the monitor address (addresses to 3 ).1 2
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
123
ON
4 5 6 7 81 2 3
ON
4 5 6 7 8123
ON
4 5 6 7 81 2 3
ON
4 5 6 7 8
1 2 3
ON
Example: 0 + 0+4+0+16 = 20
Switch number: 12345
Val ON:1 2 4 8 16ue when
Table of values
4 5 678
Important: Apartment 1 (Dip1 to ON & Dip2-Dip5 to OFF)
ART 7W/G2+ monitor .with V.04 and later
Important: Apartment 32 (Dip1 - Dip5 to OFF)
ART7W/G2+ monitor with V.07 and next (addresses 1 to 128):
Switches to 71 : 1 2 ).to 1 8Sets the monitor address (addresses
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
Switch 8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable
ends. Deactivate it only in intermediate monitors.
To define whether the monitor is master or slave:
To define whether the monitor is master or slave (see special codes page to 22).20 Each apartment must have one
master monitor, and only one.
Important: Apartment 1 (Dip1 to ON & Dip2-Dip7 to OFF)
Important: Apartment 128 (Dip1 - Dip7 to OFF).
Switch number 6 7: 1 2 3 4 5
: 1 2 4 8 16Value when ON 32 64
Table of values
123
ON
E mpl : 0+ 0+4+0+16+ = 20xa e 0+0
4 5 6 7 8
SA
GND
HZ
HZ
BUS
BUS
24V
GND
ON
1 2 3 4 5 6 7 8