10 Technical Information
Service Manual
Outdoor
Unit
Outdoor Unit Model GWH24QE-K6DNA1E/O GWH24QE-K6DNA1E/O
Outdoor Unit Product Code CB419W15701 CB419W15700
Compressor Manufacturer ZHUHAI LANDA COMPRESSOR
CO., LTD
ZHUHAI LANDA COMPRESSOR
CO., LTD
Compressor Model QXFS-D25zX090H QXFS-D25zX090H
Compressor Oil FW68DA FW68DA
Compressor Type Rotary Rotary
Compressor LRA. A 24 24
Compressor RLA A 11.7 11.7
Compressor Power Input W 2420 2420
Compressor Overload Protector HPC115/95U1/KSD115ºC HPC115/95U1/KSD115ºC
Throttling Method Electron expansion valve Electron expansion valve
Set Temperature Range ºC 16~30 16~30
Cooling Operation Ambient Temperature
Range ºC -15~43 -15~43
Heating Operation Ambient Temperature
Range ºC -15~24 -22~24
Condenser Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube
Condenser Pipe Diameter mm Φ7 Φ7
Condenser Rows-n Gap mm 2-1.4 2-1.4
Condenser Coil Length (LXDXW) mm 935X38.1X660 935X38.1X660
Fan Motor Speed rpm 800 800
Fan Motor Power Output W 60 60
Fan Motor RLA A 0.58 0.58
Fan Motor Capacitor μF / /
Outdoor Unit Air Flow Volume m3/h 3200 3200
Fan Type Axial-ow Axial-ow
Fan Diameter mm Ф520 Ф520
Defrosting Method Automatic Defrosting Automatic Defrosting
Climate Type T1 T1
Isolation I I
Moisture Protection IPX4 IPX4
Permissible Excessive Operating Pressure
for the Discharge Side MPa 4.3 4.3
Permissible Excessive Operating Pressure
for the Suction Side MPa 2.5 2.5
Sound Pressure Level (H/M/L) dB (A) 57/-/- 57/-/-
Sound Power Level (H/M/L) dB (A) 67/-/- 67/-/-
Dimension(WXHXD) mm 963X700X396 963X700X396
Dimension of Carton Box (LXWXH) mm 1026X455X735 1026X455X735
Dimension of Package(LXWXH) mm 1029X458X750 1029X458X750
Net Weight kg 53.5 53.5
Gross Weight kg 58 58
Refrigerant R32 R32
Refrigerant Charge kg 1.7 1.7
Connection
Pipe
Connection Pipe Length m 5 5
Connection Pipe Gas Additional Charge g/m 50 50
Outer Diameter Liquid Pipe mm Ф6 Ф6
Outer Diameter Gas Pipe mm Ф16 Ф16
Max Distance Height m 10 10
Max Distance Length m 20 20
Note: The connection pipe applies metric diameter.
The above data is subject to change without notice. Please refer to the nameplate of the unit.