09/21 MODEL 1001HO PAGE 1 OF 5
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
No. 0510002020 (1)
Model 1001HO
Drinking Fountain
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
LIMITED WARRANTY
HAWS warrants that all of its products are guaranteed against defective material or poor workmanship for
a period of one year from the date of shipment. The foregoing notwithstanding, HAWS warrants certain
specific products or components thereof for an adjusted period. A list of these excepted products and
components and a description of their respective warranty terms may be found here:
www.hawsco.com/warranty. HAWS’liability under this warranty shall be discharged by furnishing without
charge F.O.B. HAWS factory any goods, or part thereof, which shall appear to the Company upon
inspection to be of defective material or not of first-class workmanship, provided that a claim is made in
writing to Company within a reasonable period after receipt of the product. Where claims for defects are
made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS shall
not be liable for the cost of repairs, alterations or replacements, or the labor required to implement them,
or for any expense connected therewith made by the owner or owner’s agents, except upon written
authority from HAWS. HAWS shall not be liable for any damages caused by defective materials or poor
workmanship, except for replacements, as provided above. Buyer agrees that HAWS has made no other
warranties either express or implied in addition to those above stated, except that of title with respect to
any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special,
incidental, or consequential damages claimed to arise under the contract of sale.
Equipment manufactured by HAWS is warranted to function if installation and maintenance instructions
provided are adhered to. The units also must be used for the purpose for which they were intended. Any
HAWS emergency equipment is intended to supplement first-aid treatment. Due to widely varying
conditions, HAWS cannot guarantee that the use of this emergency equipment will prevent serious injury
or the aggravation of existing or prior injuries.
EXCEPT AS EXPRESSLY STATED HEREIN, HAWS HEREBY DISCLAIMS ALL WARRANTIES,
WHETHER EXPRESS OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT
LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. THIS WARRANTY MAY NOT BE MODIFIED OR EXTENDED WITHOUT THE
WRITTEN CONSENT OF HAWS. REMEDIES AND REPLACEMENTS STATED HEREIN ARE
EXCLUSIVE. IN NO EVENT SHALL HAWS BE LIABLE FOR ANY SPECIAL, PUNITIVE,
CONSEQUENTIAL OR INCIDENTAL DAMAGES TO ANY PERSON INCLUDING BUT NOT LIMITED
TO DAMAGES FOR LOSS OF USE OR PROFITS, SUBSTITUTE PRODUCTS OR COSTS, PROPERTY
DAMAGE, OR OTHER MONETARY LOSS.
CAUTION! Prior to making any electrical connections, verify with a voltmeter that power
from the service panel is off.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.

09/21 MODEL 1001HO PAGE 2 OF 5
RECOMMENDED TOOLS: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 3/32” and 5/32 “ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or
open-end wrench.
LOCATION OF UNIT: The Model 1001HO Drinking Fountain is a wheelchair accessible
drinking facility. The height dimensions shown, meet current ADA requirements. When
installing this unit, local, state or federal codes should be adhered to. If height other than
shown is required, then dimensions must be adjusted accordingly.
SUPPLY LINE: The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS: Inlet is 3/8” O.D. push-in type fitting. Waste outlet is 1-1/4” O.D.
tube.
ELECTRICAL CONNECTIONS: Drinking Fountain may be mounted on external wall of
building provided transformer shall be mounted inside the wall and protected from
water per NEC/CEC and local code.
Sensor:
1001HO with 1RKHO.H:100-277VAC x 9VDC, 50-60Hz, 5 Watts.
MAINTENANCE: Periodically clean out the supply line Y-strainer
INSTALLATION PROCEDURE
GENERAL NOTES:
1. For all plastic push-in type fitting connections, only connect NSF-61 copper or
plastic tubing. Stainless steel or glass tubing is not recommended. The
following assembly instructions must be followed to ensure a watertight
connection:
a. Cut tubing square and clean.
b. Mark from end of tube the length of insertion (See table below).
c. Push tube into the fitting until it bottoms out.
d. To remove, depress collet and pull tubing out.
Tube Sizes
O.D.
Tolerance
Insertion Depth
3/8”
±.005”
3/4”
INSTALLATION PROCEDURE…
STEP 1: Thoroughly flush supply line to remove all foreign matter. Connect 1/2” IPS supply
screwdriver-stop (not supplied). Install supply 3/8” O.D. tubing (supplied), between
screwdriver-stop and supplied Y-strainer (Cut tubing to proper length and follow
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297

09/21 MODEL 1001HO PAGE 3 OF 5
general notes for proper connection procedures for push-in type fittings). Connect
3/8”O.D. tube between supplied tee and fountains and solenoid valve outlet(s) (if not
already connected). See installation drawing at the end of this manual for supply
plumbing and wiring details.
STEP 2: Open screwdriver-stop wide open while checking for leaks at all connections. Also,
check waste for leaks.
STEP 3: Model 1001HO: 5867 Valve Pressure Regulator –Adjust bubbler stream height
using the black pressure regulator mounted inside bracket with HO sensor unit, by
loosening the locknut and rotating the knob clockwise to increase flow or
counterclockwise to reduce flow. Tighten the locknut and check flow height. Repeat
these steps until the bubbler flow height is correct.
STEP 4: 1RKHO.H Transformer and Sensor Setup: Refer to the 1RKHO.H manual for
instructions (supplied).
MAINTENANCE
STEP 1: Periodically clean out the supply line Y-strainer.
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1.
Insufficient bubbler flow.
1a.
Check that inlet screwdriver stop valve (not
supplied) is in wide-open position.
b.
Verify minimum 30 psi flowing supply pressure.
c.
Clean Y-Strainer.
d.
Clean screens (inside nozzle body). Unscrew
nozzle insert and very gently activate water
supply to pop out qty. 3 screens (be careful not
to lose screens). Remove any debris clogging
the screen openings and place back into nozzle
body. Reassemble nozzle insert.
For more information about Haws products, see our website: www.hawsco.com
© 2021 Haws®Corporation –All Rights Reserved
HAWS® and other trademarks usedin these materials are the exclusive property of Haws Corporation.

APPROVED
DRAWN
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BYECN NO.
PAGE
DATE
DATE
ECN:
REVISED PER
CHKD
Haws Corporation - All Rights Reserved
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER.
FV
09/28/21
1
0510002020
1001HO
1:1
11
FV
09/30/21
BJM
4 of 5
PARTS BREAKDOWN
5733
2021
FV
BUBBLER HEAD, PCP1
DESCRIPTION
ITEM 1011HO/O2
5705
2
3
4
BP6
5
6700
6
6463
7
6603
8
PBM1000
9
10
0002082253
PANEL, BACK, F/ SATIN SWIRL
PLATE, MOUNTING
STRAINER, WASTE ASSEMBLY
PANEL, ACCESS, SS SATIN
PLATE, BOTTOM, F/1000
DRIVER, NOZZLE, .25 HEX
* DENOTES OPTIONAL PART.
*
*
PARTS BREAKDOWN
1
3
2
A
7
ROTATED 90° INTO VIEW
DETAIL A
BUBBLER HEAD 5705
(TUBING CONNECTS TO
INSERT ASSY)
(OPTIONAL)
FOR REMOVAL
OF NOZZLE
WITH TUBE
0002082253
10
11
12
VRKHO6SENSOR
VRKHO8TRANSFORMER
VRKHO5SOLENOID VALVE
5867PRESSURE REGULATOR
6433Y-STRAINER
9
*
**
** REQUIRED - SOLD SEPARATELY
3
(REF)
**
4
*
5*
11
6
8
12
4
(REF)

1. HOLD ROUGH-IN DIMENSIONS ±1/8" (3.2mm).
2. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL
CODES SHOULD BE ADHERED TO FOR INSTALLATION
DIMENSIONS (LOCATIONS), WASTE AND SUPPLY REQUIREMENTS
OTHER THAN SHOWN.
INSTALLER MUST PROVIDE TRAP FOR PROPER INSTALLATION.
REFER TO 1RKHO.H OPERATION AND MAINTENANCE
INSTRUCTIONS FOR TRANSFORMER AND SENSOR SETUP.
NOTES:
3
4
BP6 BACK PANEL
(OPTIONAL)
TRAP ACCESS PANEL
MODEL 6603
(OPTIONAL)
Ø3/8" SUPPLY TUBING
(SUPPLIED)
SCREW DRIVER STOP
(NOT SHOWN) IS NOT
SUPPLIED
6700 MOUNTING PLATE
(BEHIND FINISH WALL)
MOUNTING BOLTS
(NOT SUPPLIED)
WASTE BEND AND
1-1/4" IPS TRAP
(NOT SUPPLIED)
A
A
1 1/4" OD
WASTE BEND
(SUPPLIED)
6700 MOUNTING PLATE
MUST BE INSTALLED BEFORE FINISH WORK
THIS PLATE IS REQUIRED - SOLD SEPARATELY.
SECTION A-A
ROTATED 90° INTO VIEW
BRACKET MOUNTING
DETAIL
WALL FACE
FLOOR LINE
WALL STUD
WALL FACE
4X 3/8-16 UNC
[359]
ø14 1/8"
[406]
16"
[83]
3 1/4"
[133]
5 1/4"
[76]
3"
[47]
1 27/32"
[76]
3"
[10]
4X ø3/8"
[47]
1 27/32"
[25]
1"
[58]
2 9/32"
[51]
2"
[406]
16"
[457]
18"
[127]
5"
[178]
7"
[729]
28 11/16"
SUPPLY
[714]
28 3/32"
WASTE
[686]
27"
[864]
34"
(TO SPOUT
OUTLET)
[76]
3"
[473]
18 5/8"
[380]
15"
[645]
25 3/8"
11116" [42]
APPROVED:
DRAWN:
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
PAGE
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
CR
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
FV
09/28/21
1
0510002020.D
1001HO
1:1
11
FV
09/30/21
BJM
5 of 5
INSTALLATION
5733
5 of 5
2021
FV
LOCATE AND INSTALL
ELECTRICAL
9VDC SOLENOID VALVE
TRANSFORMER
WITHIN WALL
SENSOR
EYE
4
SUPPLY LINE
SENSOR
FROM SUPPLY
TO
BUBBLER
HEAD
-Vo
+Vo
AC(L)
AC(N)
BLACK WIRE
WHITE WIRE
TRANSFORMER
SENSOR WIRING / SUPPLY PLUMBING
SCHEMATIC
SOLENOID
VALVE
Y-STRAINER
PRESSURE
REGULATOR
(Y-STRAINER NOT SHOWN)
3
100-277VAC-9VDC
TRANSFORMER
AND DC CABLE
(SUPPLIED)
FROM DIRECT
CONTACT WITH WATER
MUST BE PROTECTED
4
Y-STRAINER
(SUPPLIED)
4
9" [228]
REGULATOR
3
Table of contents
Other Haws Outdoor Fountain manuals
Popular Outdoor Fountain manuals by other brands

Kelkay
Kelkay 45000L instructions

Sunnydaze Decor
Sunnydaze Decor DW-35126 Assembly instructions

Angelo Decor
Angelo Decor AD99021 quick start guide

Astonica
Astonica 04-02-00006 instruction manual

Ritchie
Ritchie OmniFount 3 installation instructions

Sunnydaze Decor
Sunnydaze Decor SL0430 Assembly instructions

Xbrand
Xbrand Buddha Fountain quick start guide

Murdock
Murdock A172-SO Series Installation & maintenance instructions

Halsey Taylor
Halsey Taylor 4592FR owner's manual

AquaScape
AquaScape 39000 installation instructions

Campania International
Campania International Bebel FT-362 Assembly instructions

Alpine
Alpine DIG150 quick start guide