5
5.
.CONTROL
CONTROL MODE
MODE
motor(PG regulating motor or tapped regulating motor), digital tube and
LED display, Electrical heating signal, Buzzer, Outdoor fan motor, Coil of the
4-way reversing valve, Compressor( or AC contactor).
4.2 Cooling only split unit: Air flow motor (step motor), indoor fan
motor(PG regulating motor or tapped regulating motor),digital tube and LED
display, Buzzer, Outdoor fan motor, Coil of the 4-way reversing valve,
Compressor( or AC contactor).
5. Operation Mode
5.1 Operation mode
Operation mode: Cooling mode, Heat mode, Dry mode, Fan only mode.
5.2 Mode and function combination
These 4 modes contain the combination of the hereinbefore functions,
and run these operations control by remote control also.
5.3 Emergent start
If the appliance under the Stand-by state, all the Operation Mode, Air
volume, Temperature Setting , Forced Cooling function will be restored as
the last time setting when you press on the “ON/OFF” button, but lost the Air
flow direction setting, Delay time of Non-real Time Setting(Low end), and
sleep function.
If the appliance was connected to the power at first time, it would
operate in the smart mode, and set the mode, swing louver angle and the Air
volume when you press the “ON/OFF” button. It will keep in stand-by state
if you press the “ON/OFF” button during the normal operation.
5.4 Other control mode
(1)When the PCB circuit was connected to the power at first time, the
buzzer triggered and beep.
(2)The compressor responded the variation of temperature after the
compressor operated in 3 min, and it will be ceased for 3 min then re-start.
When the operation mode changed or power off, the compressor turned off
immediately. For the other normal operation, the compressor has a 3 min
delay protection. If the compressor Power ON or OFF, the outdoor fan motor
will be ON or OFF correspondingly.
(3)The appliance is ceased for 3 min delay protection when the
auto-restart after blankout.
(4)
The appliance is ceased for 5 sec delay protection to perform the other
operation after it receive the signal of specific operation, but no any delay for
the response.
(5)When the appliance power OFF, the indoor fan motor operated as
below condition:
a.Cooling and Dry mode: After the compressor power off, it will be
operated in 30 sec under the presetting speed then turn off.
b.Fan only mode: it will be stopped immediately after the compressor
power off.
c.Heating mode: After the compressor stopped, the indoor fan motor