HVTest HTYX-III User manual

1
Dear Client
Thank you for Purchasing our HTYX-III Phase Shifter. Please read the
manual in detail prior to first use, which will help you use the equipment
skillfully.
Our aim is to improve and perfect the company's products
continually, so there may be slight differences between your
purchase equipment and its instruction manual. You can find
the changes in the appendix. Sorry for the inconvenience. If
you have further questions, welcome to contact with our service
department.
The input/output terminals and the test column may bring
voltage, when you plug/draw the test wire or power outlet, they
will cause electric spark. PLEASE CAUTION RISK OF
ELECTRICAL SHOCK!
Company Address:
T4,No. 41, High-tech 2 Road,East Lake High-tech Development Zone,Wuhan
Sales Hotline: 86-27- 87457960
After Service Hotline:86-27- 87459656
Fax: 86-27- 87803129
E-mail: [email protected]
Website: www.hvtest.cc

2
SERIOUS COMMITMENT
All products of our company carry one year limited warranty from the date
of shipment. If any such product proves defective during this warranty period
we will maintain it for free. Meanwhile we implement lifetime service. Except
otherwise agreed by contract.
SAFETY REQUIREMENTS
Please read the following safety precautions carefully to avoid body injury
and prevent the product or other relevant subassembly to damage. In order to
avoid possible danger, this product can only be used within the prescribed
scope.
Only qualified technician can carry out maintenance or repair work.
--To avoid fire and personal injury:
Use Proper Power Cord
Only use the power wire supplied by the product or meet the specification
of this produce.
Connect and Disconnect Correctly
When the test wire is connected to the live terminal, please do not
connect or disconnect the test wire.
Grounding
The product is grounded through the power wire; besides, the ground
pole of the shell must be grounded. To prevent electric shock, the grounding
conductor must be connected to the ground.

3
Make sure the product has been grounded correctly before connecting
with the input/output port.
Pay Attention to the Ratings of All Terminals
To prevent the fire hazard or electric shock, please be care of all ratings
and labels/marks of this product. Before connecting, please read the
instruction manual to acquire information about the ratings.
Do Not Operate without Covers
Do not operate this product when covers or panels removed.
Use Proper Fuse
Only use the fuse with type and rating specified for the product.
Avoid Touching Bare Circuit and Charged Metal
Do not touch the bare connection points and parts of energized
equipment.
Do Not Operate with Suspicious Failures
If you encounter operating failure, do not continue. Please contact with
our maintenance staff.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in Explosive Atmospheres.
Ensure Product Surfaces Clean and Dry.

4
-Security Terms
Warning: indicates that death or severe personal injury may result if proper
precautions are not taken
Caution: indicates that property damage may result if proper precautions
are not taken.

5
Contents
Ⅰ.OUTLINE.................................................................................................6
Ⅱ. APPLICATION AND APPLIED SCOPE...........................................6
Ⅲ. MAIN TECHNOLOGY INDICATORS............................................... 7
Ⅳ.FUNDAMENTAL THEORY..................................................................8
Ⅴ.HOW TO USE........................................................................................ 8
Ⅵ.NOTES.................................................................................................. 11
Ⅶ.MAINTENANCE.................................................................................. 12
Ⅷ.TRANSPORT AND STORAGE........................................................ 13

6
Ⅰ.OUTLINE
Phase shifter is a new generation of portable electrical equipment which
is composed by transformer phase shifter, digital phase display, digital voltage
and current display, output voltage adjustment, fine-tune of phase shift and
power source modules and so on, this product combine the technology of
transformer phase shifter and digital measurement, with the advantages of
high precision for phase adjustment ,accurate and intuitive readings,
adjustable output voltage. The structure of this machine is solid and reliable,
sealed, and easy to carry or to use in the field and on site.
Ⅱ. APPLICATION AND APPLIED SCOPE
Phase shifter can reach any point of the lead or lag phase shift from 0 to
360 degrees.
The phase shifter transformer has three phases and three core
columns,with Y0 wiring way. Each phase has four equilateral windings, whith
are cross-connected with different angles to form a hexagon connected to the
diagonals. The hexagon has tewlve files, and each file has 30 degrees.Thus
we can do synchronous adjustment of three phases. The fine tune bases on
three coaxial autotransformers and capacitors, and the output phase in the
range of 0 to 360 can be adjusted simultaneousely to ensure the balance
output of three phases.

7
The phase shifter has the characteristics of easy operation, small size,
low noise and good output waveform, whith is able to meet the test and
calibration for high AC power and phase of single or three phases, phase and
other, and can also be used among test device of meter.
Ⅲ. MAIN TECHNOLOGY INDICATORS
1.Input voltage:Three-phase four-wire 3×380(220)V 50Hz
2.Output Voltage:Three-phase four-wire 3×(0~380) / (0~220),Three and a
half figures display, accuracy: 1.0grade
Output current: AC 0-20A Three and a half figures display, accuracy:
1.0grade
3.Maximum output capacity 3×300VA
4.Rough tune of three phase: 0° ~ 360°, 30° to phase shift of each step
5.fine tune for three phase: -3° ~ 18°, 12° ~ 33°, four figures display, accuracy:
0.5grade
6. Voltage fluctuation: rough tune ≤ 1.5%, fine tune ≤ 2.0%
7.Waveform distortion: distortion of input waveform ≤ distortion of output
waveform
8.Increasing of temperature:<60 ℃
9. Insulation resistance: ≥ 22MΩ
10.Pressure test: 1.5kV/min
11.Environment: temperature -10℃~ 40℃, humidity<80%

8
12.Size: 480×360×230mm
13.Weight: about 35kg
*When doing the rough tune adjustment clockwisely to decreasing phase
shift, please exchange the sequence of any input three phase.
Ⅳ.FUNDAMENTAL THEORY
This phase shifter is designed amd maded by the theory of transformer
phase shift,and the fundamental theory is explained in the block diagram:
Ⅴ.HOW TO USE
(1)The panel diagrame and description of digital three-phase phase shifter
Panel:

9
A1. Phase shift display, Four figures display 0° ~ 360° phase angle.
A2. Load current display of output V phase, three and a half figures display.
A3. Voltage display of between output U, W phase, three and a half figures
display.
A4. Rough tune button,phase shift by the surface scale.
A5. Reset button of phase display. Press the key to display the phase angle.
A6. Latch button of phase display.With no change of phase, we can press the
key to lock the number.
A7. Power switch, this key can be pressed to put on or cut off the whole
internal power supply.
A8. Switch for the choice of output function. When it is turned to voltage
function, the machine gives the output of voltages of U,V,M phases which are
corresponding to the phase shift of input A,B,C source; and when turned to

10
current function, the machine gives the output of AC current range from 0~20
A, witch lead to the phase shift of iuput B source.
A9. Fine tune selection switch, choice of two range: -3°~18°, 12°~33°.
A10. Adjustment button of output voltage, and the outputs of U,V,W phase are
adjusted simultaneousely by this button.The voltage display gives the voltage
of U,W phase range from 0~380V.
A11. Fine tune button, combined with A9 it can achieve the function of phase
shift in 30°.
B1.Binding columns of input three phases and four wires.
B2.Ground column of the chassis.
B3.F1, F2, F3 buttons are respectively corresponding to the insurance block of
C, B, A phases.
B4. Binding columns of output three phases and four wires.
B5. F4, F5, F6 buttons are respectively corresponding to the insurance block
of W, V, U phases.
B6. Binding column of output current.
(2) How to use
1. Check B3, B5 of the panel to insure the fuse is intact.
2. Cut off the power button and turn the the output voltage button A10 to the
lowest,then connect the input source of three phases and four wires A, B, C, O
on the panel B1.
3. Connect the neccesary load for output voltage of U, V, W, N phases on the

11
panel B3. the load power can not exceed the maximum output power of the
machine.
4. Close the external blade, and turn on the machine power switch A7, the
displays of A1, A2, A3 also should be light.
5. Adjust the output voltage button A10 to the designed value after power on
for half a minute.Get the output voltage from U, V, M, N phases, among witch
A3 dispalys the voltage of U, W phases, A2 displays the load current of V
phase.
6. Adjust the rough tune button to the approximate designed phase shift angle,
then adjust the fine tune button A11 with the selection switch A9(when the
switch is up, adjust A11 clockwisely for one loop and the phase shift is 15° ;
when the switch is down, adjust A11 Counterclockwisely for one loop and the
phase shift is 15°).After adjustting A4 button,turn the selection swith A9 to the
top and turn the button A11 clockwisely, then the display of phase shift
increases.One scale of rough tune includes fine tune range from 0°~30°, and
the A1 displays the phase shift angle with the reset button A5.After adjusted to
the designed angle,press latch button A6 to lock the number of A1.Also, Press
A5 again to get a new phase shift angle.
Ⅵ.NOTES
1. It is not allowed to connect the output point N to input zero line.
2.The machine is on the work with strong power, so it is necessary that ground

12
column of the chassis to be grounded.
3.The maximum current of the fuse is 5A and as the short circuit and overload
protection it is necessary to comply the provision.
4. Minus the number of A2, A3 witch is get from the situation as output is zero
to resist the environment interference.
5. After turning on the power, if without any display, Cut off the power.firstly,
check the insurance and then check the external input of three phases and
four wires. If still with no display, please contact us.
6. The warranty of the product is one year. Among the warranty period it is
free to repair the machine because of quality and technical problems and we
provide preferential services caused by careless handling.
Ⅶ.MAINTENANCE
1. Verify the availability of the equipment
Observe the appearance of the instrument before use. After turning on
the power check the instrument display is showing completely or not. If the
instrument is not used for long time it is should also check whether the Binding
columns of output part are corroded or aging. Clear up before use timely.
Refer to "How to use" chapter when using it.
2. Equipment maintenance
After test, clear the wires connected among columns, then cut off the
power and disconnect the power plug , cover the chassis cover finally place

13
the equipment indoors in dry, clean, non-corrosive gas environment.
3. The way of replacing the fuse
The fuse and the power plug is connected so turn off the power before
replacing, then set aside the fuse box with a small flathead screwdriver.
Ⅷ.TRANSPORT AND STORAGE
■Transport
we recommend use our packing boxes and cushioning materials, in order
to avoid unnecessary damage during transit, and causing unnecessary losses
to you.
It is not allowed stacking emission without wooden box during transit. The
maximum packing stacking layers is tow with our box.
During transit, make sure the panel is up.
■Storage
Store the equipment indoors in dry, clean, non-corrosive gas environment.
It is not allowed stacking emission without wooden box
Place pad in the bottom of the equipment in order to prevent equipment
from moisture.
During transit, make sure the panel is up.
Table of contents
Other HVTest Test Equipment manuals

HVTest
HVTest HTJS-V User manual

HVTest
HVTest HTJY-80S User manual

HVTest
HVTest HT2672 User manual

HVTest
HVTest HTRG-H User manual

HVTest
HVTest HT2533 User manual

HVTest
HVTest HTYB-3H User manual

HVTest
HVTest HTZZ-S10A User manual

HVTest
HVTest TAG-8000 User manual

HVTest
HVTest HT2571B User manual

HVTest
HVTest HTZZ-1A User manual

HVTest
HVTest HTFZ-HI User manual

HVTest
HVTest HTZZ-2A User manual

HVTest
HVTest HTYSZ-H User manual

HVTest
HVTest HT2670 User manual

HVTest
HVTest HT5600 User manual

HVTest
HVTest HT2671 User manual

HVTest
HVTest HTFZ-III User manual

HVTest
HVTest HTJS-M User manual

HVTest
HVTest HTYZL-H User manual

HVTest
HVTest ETCR2000 User manual