manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Icom
  6. •
  7. Cables And Connectors
  8. •
  9. Icom OPC-2275 User manual

Icom OPC-2275 User manual

CONNECTION CABLE
INSTRUCTION MANUAL
Thank you for purchasing this Icom product.
The OPC-2275 CONNECTION CABLE is used to connect a
transceiver to the VE-PG3.
READ ALL INSTRUCTIONS carefully and completely be-
fore using the cable.
CONNECTING THE OPC-2275
CAUTION
• Verify that both the transceiver and the VE-PG3 are turned OFF when connecting or disconnecting the cable.
• Hold the connector body when connecting or disconnecting them.
• Never bend or pinch the cable.
• Never place a heavy object on the cable.
• Never touch the cable with wet hands.
• Always connect the cable correctly. An incorrect connection could damage the VE-PG3 and/or the transceiver.
Set the transceiver channel, volume level, TX output power, and other necessary settings.
(See the transceiver and the VE-PG3 instruction manuals for setting details.)
1
Turn OFF both the transceiver and the VE-PG3. Remove the microphone and external speaker from the transceiver,
and then connect the OPC-2275, as shown below.
2
VE-PG3 (Rear view) Icom’s transceiver
(IC-F5060/IC-F6060 series) (Rear view)
(Front view)
To the external speaker jack
To the microphone connector
LINE2 LINE1
PHONE
•
The [TRX1] and [TRX2] ports (upper slots) accept the OPC-2275 connectors,
however, follow the example to correctly connect the transceiver to ONLY the [TRX1] on the VE-PG3.
ABC
Be sure to insert the
connectors top side up.
Bottom
To p
A
1234
OPC-2275
AABC
To [TRX1] (Upper slots)
Connector
body
Connector
body
Connector
body
When other cables are connected, you can
use needle-nose pliers to carefully insert or
remove connectors.
VE-PG3 (Rear view)VE-PG3 (Rear view)
Needle-nose pliersNeedle-nose pliers NEVER pull the connector by holding the
cable. This will damage the cable.
*If the cable becomes damaged, replace the
connector(s).See “REPLACING THE
CONNECTOR” on the reverse side for
replacement details.
REPLACING THE CONNECTOR
If the cable becomes damaged, replace the connector(s). Make wire connections as described below.
• Spare connectors*1are supplied with the VE-PG3.
*1Manufacturer: DDK. Name: 232D-04S1B-DA5-FA (Equivalent to the OPC-2275 connector.)
The connector has two parts; a black base and a clear insert. DO NOT lock the connector parts before inserting all wires.
Insert the wires into the holes
according to the assigned pin
numbers.
1Press the clear insert down
until it locks in place.
2
Connector
(Supplied with
the VE-PG3)
Connector
(Supplied with
the VE-PG3)
Connector
(Supplied with
the VE-PG3)
The wires for each hole are
assigned by color. See the
illustration below.
OPC-2275
To the transceiver
• Turn OFF the VE-PG3 and the transceiver before connecting or disconnecting the OPC-2275.
• Follow the example to correctly connect the transceiver to [TRX1] on the VE-PG3.
LINE2 LINE1
PHONE
BC
A
1234 1234 1234
A
White
WhiteWhite
Brown
BrownBrown
Yellow
YellowYellow
Gray
GrayGray
Green
GreenGreen
Black
BlackBlack
B
Connector top (Expanded view)
VE-PG3 (Rear view)
VE-PG3 (Rear view)
VE-PG3 (Rear view)
Red
RedRed
Blue
BlueBlue
C
AABC
To [TRX1] (Upper slots)
OPC-2275 connection and wires assignment
RECOMMENDATION
If reconnecting is re-
peated about 30 times,
cut the wires*2 *3near
the connector and re-
place the connector.
*2Remove the cable from the VE-PG3,
before cutting the wires.
*3DO NOT cut the wires too short. Other-
wise it will be difficult to reconnect them
to the VE-PG3.
1234
• After the insert is locked, it is
impossible to release it again.
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the
United Kingdom, Germany, France, Spain, Russia and/or other countries.
A-7044X-1EX
Printed in Japan
© 2012 Icom Inc.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan

Other Icom Cables And Connectors manuals

Icom opc-478uc User manual

Icom

Icom opc-478uc User manual

Icom OPC-2389 User manual

Icom

Icom OPC-2389 User manual

Icom OPC-2274 User manual

Icom

Icom OPC-2274 User manual

Icom opc-478uc User manual

Icom

Icom opc-478uc User manual

Icom OPC-478UC User manual

Icom

Icom OPC-478UC User manual

Icom OPC-2273 User manual

Icom

Icom OPC-2273 User manual

Icom OPC-2350LU User manual

Icom

Icom OPC-2350LU User manual

Icom OPC-2350LU User manual

Icom

Icom OPC-2350LU User manual

Icom OPC-2218 LU User manual

Icom

Icom OPC-2218 LU User manual

Icom OPC- 2218LU User manual

Icom

Icom OPC- 2218LU User manual

Icom OPC-966U-1 User manual

Icom

Icom OPC-966U-1 User manual

Icom OPC-2276 User manual

Icom

Icom OPC-2276 User manual

Icom OPC-2328 User manual

Icom

Icom OPC-2328 User manual

Icom OPC-1122U User manual

Icom

Icom OPC-1122U User manual

Icom OPC-2218LU User manual

Icom

Icom OPC-2218LU User manual

Icom OPC-2350LU User manual

Icom

Icom OPC-2350LU User manual

Popular Cables And Connectors manuals by other brands

WARRKY DH1 Series user guide

WARRKY

WARRKY DH1 Series user guide

Philips SDW5212O Specifications

Philips

Philips SDW5212O Specifications

Philips SWV3601S/10 user manual

Philips

Philips SWV3601S/10 user manual

Winegard CSK-300 quick start guide

Winegard

Winegard CSK-300 quick start guide

Belden FX FUSION SC CONNECTOR installation guide

Belden

Belden FX FUSION SC CONNECTOR installation guide

StarTech.com VS440HDMI user guide

StarTech.com

StarTech.com VS440HDMI user guide

evplug EV20021 quick start guide

evplug

evplug EV20021 quick start guide

Staubli SMK425-L Assembly instructions

Staubli

Staubli SMK425-L Assembly instructions

Kenton THRU-5 operating manual

Kenton

Kenton THRU-5 operating manual

Digitus DS-55314 manual

Digitus

Digitus DS-55314 manual

Marechal Electric MELTRIC CS1000 installation instructions

Marechal Electric

Marechal Electric MELTRIC CS1000 installation instructions

HydRemote Cable System user guide

HydRemote

HydRemote Cable System user guide

Gentec UH0102 user manual

Gentec

Gentec UH0102 user manual

Panasonic CA-LSR01U Installation

Panasonic

Panasonic CA-LSR01U Installation

ADC Triaxial Camera Connectors ProAx Specification sheet

ADC

ADC Triaxial Camera Connectors ProAx Specification sheet

Philips SWV2826W Specifications

Philips

Philips SWV2826W Specifications

CYP CLUX-18W Operation manual

CYP

CYP CLUX-18W Operation manual

Philips SWA5580 Specifications

Philips

Philips SWA5580 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.