Specifications
ALE
Automatic-Feed Soldering Control Unit
With Solder Wire Perforation
for wire ø0.8mm:
Ref. ALE-908UVA - 100V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
Ref. ALE-108UVA -120V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
Ref. ALE-208UVA - 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire ø1.0mm:
Ref. ALE-910UVA - 100V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
Ref. ALE-110UVA -120V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
Ref. ALE-210UVA - 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire ø1.2mm.
Ref. ALE-212UVA - 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire ø1.6mm:
Ref. ALE-216UVA - 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
Without Solder Wire Perforation
for wire ø0.4mm:
Ref. ALE-204UA - 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire ø0.5mm:
Ref. ALE-205UA - 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire ø0.8mm:
Ref. ALE-208UA - 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire ø1.0mm:
Ref. ALE-110UA -120V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
- Output Peak Power: 130 W / 23.5 V
- Selectabe Temperature Range: 90 - 450 °C / 190 - 840 °F
- Idle Temp. Stability (still air): ±1.5ºC / ±3ºF (Meets and exceed IPC J-STD-001)
- Temp. Accuracy: ±3% (Using reference cartridge)
- Temp. Adjustment: ±50ºC / ±90ºF (Through station menu settings)
- Connections: USB-A Uptade and files import-export
USB-B Software PC
RJ12 Fume extractor connection
- Equipontencial bonding: Optional connection to EPA
- Tip to Ground Voltage/Resistance: <2 mV RMS / <2 ohms
Meets and exceed
ANSI/ESD S20.20-2014 / IPC J-STD-001F
- Ambient Operating Temp: 10 - 50 ºC / 50 - 122 ºF
18