jbc HDU User manual

HDU
Heavy Duty Control Unit
INSTRUCTION MANUAL

2
Manual ............................ 1 unit
Ref. 0028871
HDU Control Unit ......... 1 unit
Features
USB-A connector
2,8” Color TFT screen
Tilt the display
for easy reading
Power Cord .................... 1 unit
Ref. 0024077 (100V)
0023717 (120V)
0024080 (230V)
Packing List
The following items are included:
This manual corresponds to the following references:
HDE-9UD (100V)
HDE-1UD (120V)
HDE-2UD (230V)
Main Switch
To Tools

3
Connections
HDU Control Unit
RJ12 connector for
Robot or Smart Fume
Extractors
USB-B
connector
Equipotential
connection
Power Socket
Compatibility
Select the equipment that best suit your soldering or desoldering needs.
Control
Unit Tool Stand Cartridge
Range MNE-A FSE-A P-005
HDU
T470
HDS
C470
T470S
T470Z
T470F
HT470* HDTS
T470-N* * DNS
* It works with two HDU Control Units in order to manage the cartridges individually
** The MNE Nitrogen Flow Regulator is required.
Tool*
see compatibility
table below
Stand*
see compatibility
table below
Module* / Pedal*
see compatibility
table below
* not included, sold separately
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

380ºC
Port
1
Power
45%
Temp. Levels
T470
250 380 400
17:14
350ºC
Port
1
Power
45%
Temp. Levels
T470
250 350 400
17:14
380ºC
Port
1
Power
45%
Temp. Levels
T470
250 380 400
17:14
350ºC
Port
1
Power
45%
Temp. Levels
250 350
17:14
T245
380
Menu Options
Station
Information
Power
Indicator
Tool
in use
DDE Work Screen
Status Bar
The DDE offers an intuitive user interface which provides quick access to station parameters.
Default PIN: 0105
Change
Port
Displayed if
Temperature
Levels are
Activated
Station Tools Counters
ResetLanguagePeripherals
Set the station
parameters
Set the tool
parameters
Consult / modify the
links of the peripherals
connected to the
station with the port
they are connected to.
Display the hours
worked in each cycle
It is possible to
choose the language
from a list.
Allows you to carry
out an overall station
reset restoring all the
parameters to their
default values.
Station troubleshooting available on the product page at www.jbctools.com
Troubleshooting
4
Power
indicator
Tool
in Use
Work Screen
Status Bar
The HDE offers an intuitive user interface which provides quick access to station parameters.
Default PIN: 0105
Displayed if
temperature
levels are
activated

5
JBC Net
Export graphics
Insert a USB flash drive into the
USB-A connector to save your
soldering process in csv format.
Profiles
Advanced Functionalities
It provides detailed graphics of tip temperature and power delivery in real time during
solder joint formation for analysis purposes. This helps you decide how to adjust your
process or which tip to use to obtain the best quality soldering.
Graphics
Get greater quality and control in your production.
Manage your whole soldering process remotely in real time.
For more information see www.jbctools.com/webmanager.html.
Designed to avoid thermal shock when soldering Ceramic Chip components like
MLCC, this new and unique feature allows controlling the heating ramp up rate of the
tool to gradually increase the temperature of the component through all the phases of
the soldering process. Up to 25 fully configurable soldering profiles can be stored.
USB flash drive is connected.
Station is controlled by a PC.
Station is controlled by a robot.
System notifications
Station software update.
Press INFO to start the process.
Warning.
Press INFO for failure description.
Error.
Press INFO for failure description,
the type of error and how to proceed.
The following icons will be displayed on the screen’s status bar.
Station update
Download the JBC Update File from
www.jbctools.com/software.html
Insert the USB flash drive with the
file downloaded to the station.
Files
Update
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

JBC
Manager
Software
6
Soldering Net
Remotely manage and monitor as many stations as your Windows PC can handle.
Functions:
- Set all the station parameters from your PC.
- Organize groups of stations and set all their parameters at the same time.
- Store specific configurations for later uses.
- Analyze the soldering graphics of the stations on
your PC and export them.
1. Download the JBC Software Manager and the user manual from jbcnet.solutions
2. Connect the stations via USB-B connector and the PC will automatically detect them.
3. The notification will be displayed on the station.
any JBC
station
USB Hub
350ºC
Port
3
Power
45%
Selected 350º
+
C245-003
MENU
17:14 ?
Port
3
Port
3
Sleep
Tool in the stand
Actual Temp. 180ºC
Delay to hibernation: 29:30
MENU
17:14
?
3
Port
Hibernation
Actual Temp. 25ºC
MENU
17:14
?
OK
350 ºC
Port
1
Power
45%
Temp. Levels
T245
250 350 380
17:14
OK
350 ºC
Port
1
Power
45%
Temp. Levels
T245
250 350 380
17:14
OK
350 ºC
Port
1
Power
45%
Temp. Levels
T245
250 350 380
17:14
Operation
The JBC Most Efficient Soldering System
Our revolutionary technology is able to recover tip temperature extremely quickly. It means the user
can work at a lower temperature and improve the quality of soldering. The tip temperature is further
reduced thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip.
3. Hibernation1. Work 2. Sleep
When the tool is lifted from
the stand the tip will heat up
to the selected temperature.
When the tool is in the stand,
the temperature falls to the
preset Sleep temperature.
After longer periods of
inactivity, the power is cut off
and the tool cools down to
room temperature.
Long period
in the stand
Tools Menu:
· Adjust temperature limits and
cartridge.
· Set temperature levels.
Tools Menu:
· Set Sleep temperature.
· Set Sleep delay.
(from 0 to 9 min or no Sleep)
Tools Menu:
· Set Hibernation delay.
(from 0 to 60 min or no
hibernation)

Sleep
Port
1
Tool in the stand
17:14
Actual Temp. 180ºC
T470
Delay to hibernation: 29:30
Port
1
Actual Temp. 25ºC
17:14
T470
Hibernation
350ºC
Port
1
Power
45%
Temp. Levels
T470
250 350
17:14
400
7
Tools Menu:
· Set Sleep temperature
· Set Sleep delay
(from 0 to 9 min or no Sleep)
Tools Menu:
· Set Hibernation delay
(from 0 to 60 min or no
hibernation)
Tools Menu:
· Set temperature limits
· Select temperature levels
350ºC
Port
3
Power
45%
Selected 350º
+
C245-003
MENU
17:14 ?
Port
3
Port
3
Sleep
Tool in the stand
Actual Temp. 180ºC
Delay to hibernation: 29:30
MENU
17:14
?
3
Port
Hibernation
Actual Temp. 25ºC
MENU
17:14
?
OK
350 ºC
Port
1
Power
45%
Temp. Levels
T245
250 350 380
17:14
OK
350 ºC
Port
1
Power
45%
Temp. Levels
T245
250 350 380
17:14
OK
350 ºC
Port
1
Power
45%
Temp. Levels
T245
250 350 380
17:14
Operation
The JBC Most Efficient Soldering System
Our revolutionary technology is able to recover tip temperature extremely quickly. It means the user
can work at a lower temperature and improve the quality of soldering. The tip temperature is further
reduced thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip.
3. Hibernation1. Work 2. Sleep
When the tool is lifted from
the stand the tip will heat up
to the selected temperature.
When the tool is in the stand,
the temperature falls to the
preset Sleep temperature.
After longer periods of
inactivity, the power is cut off
and the tool cools down to
room temperature.
Long period
in the stand
Tools Menu:
· Adjust temperature limits and
cartridge.
· Set temperature levels.
Tools Menu:
· Set Sleep temperature.
· Set Sleep delay.
(from 0 to 9 min or no Sleep)
Tools Menu:
· Set Hibernation delay.
(from 0 to 60 min or no
hibernation)
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

OK
350 ºC
Port
1
Power
45%
Temp. Levels
T245
250 350 380
17:14
OK
350 ºC
Port
1
Power
45%
Temp. Levels
T245
250 350 380
17:14
Clean
periodically
8
Maintenance
Before carrying out maintenance or storage, always allow the equipment to cool.
- Clean the station screen with a glass cleaner
or a damp cloth.
1. Pull off the fuse holder and remove the
fuse. If necessary use a tool to lever it off.
2. Press the new fuse into the fuse holder
and replace it in the station.
- Use a damp cloth to clean the casing and the
tool. Alcohol can only be used to clean the
metal parts.
- Periodically check that the metal parts of the
tool and stand are clean so that the station
can detect the tool status.
- Maintain tip surface clean and tinned prior to
storage in order to avoid tip oxidation. Rusty
and dirty surfaces reduce heat transfer to the
solder joint.
- Periodically check all cables and tubes.
- Replace a blown fuse as follows:
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
Fuse holder Fuse holder
Fuse

9
Safety
- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Be sure that it is properly grounded before
use. When unplugging it, hold the plug, not the wire.
- Do not work on electrically live parts.
- The tool should be placed in the stand when not in use in order to activate the sleep mode. The
soldering tip or nozzle, the metal part of the tool and the stand may still be hot even when the station
is turned off. Handle with care, including when adjusting the stand position.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Avoid flux coming into contact with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working
to avoid personal harm.
- Utmost care must be taken with liquid tin waste which can cause burns.
- This appliance can be used by children over the age of eight and also persons with reduced physical,
sensory or mental capabilities or lack of experience provided that they have been given adequate
supervision or instruction concerning use of the appliance and understand the hazards involved.
Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.
It is imperative to follow safety guidelines to prevent electric
shock, injury, fire or explosion.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

10
Notes

11
Specifications
HDU
Heavy Duty Control Unit
Ref. HDE-9UD 100V 50/60Hz. Input fuse: 4A. Output: 42V.
Ref. HDE-1UD 120V 50/60Hz. Input fuse: 4A. Output: 42V.
Ref. HDE-2UD 230V 50/60Hz. Input fuse: 2A. Output: 42V.
- Output Peak Power: 250W
- Temperature Range: 90 - 500 °C / 190 - 932 °F
- Idle Temp. Stability (still air): ±1.5 ºC / ±3 ºF (Meets and exceed IPC J-STD-001F)
- Temp accuracy: ±3% (using reference cartridge)
- Temp adjustment: ±50ºC / ±90ºF Through station menu setting
- Tip to Ground Voltage/Resistance:Meets and exceed
ANSI/ESD S20.20-2014 IPC J-STD-001F
- Ambient Operating Temp.: 10 - 50 ºC / 50 - 122 ºF
- Connections: USB-A / USB-B / Peripherals connectors
RJ12 connector for Robot or for Fume Extractor
- Control Unit Dimensions: 232 x 148 x 120 mm / 9.13 x 5.83 x 4.72 in
- Total Net Weight: 2.63 kg / 5.79 lb
- Total Package Dimensions/Weight: 258 x 328 x 208 mm / 3.72 kg
(L x W x H) 10.16 x 12.91 x 8.19 in / 8.21 lb
Complies with CE standards.
ESD safe.
Notes
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must
be collected and returned to an authorized recycling facility.
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/
within 30 days of purchase.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
0028871-0322
Other manuals for HDU
1
This manual suits for next models
3
Table of contents
Other jbc Control Unit manuals
Popular Control Unit manuals by other brands

Circor
Circor D Series his document is the property of Circor Flow Technologies India Pvt Limited should not copiINSTALLATI

PCB Piezotronics
PCB Piezotronics 070M69 Installation and operating manual

Trenz Electronic
Trenz Electronic TE0712 35-2I9 Series Schematics

Dusun
Dusun DSM-102-IPEX user manual

Siemens
Siemens SZE-4X installation instructions

Reliance electric
Reliance electric MD65 instruction manual