jbc DDE-C User manual

INSTRUCTION MANUAL
Two-Tool Control Unit
Ref. DDE-C
www.jbctools.com

Packing List
The following items should be included:
Features
Two-Tool
Control Unit .................... 1 unit
Ref. DDE-1C (120V)
DDE-2C(230V)
DDE-9C(100V)
Power Cord ..................... 1 unit
Ref. 0010569 (230V)
0013671 (100/120V)
Manual ...............................1 unit
Ref. 0019248
USB-A connector
2,8” Color TFT screen
Tilt the display
for easy reading
Two-Tool Control Unit
Ref. DDE-C
2
www.jbctools.com

Connections
Work simultaneously with
up to 2 tools and 1 module
+ 1 pedal for each tool
(Peripherals).
Peripherals
Stand
DDE Control Unit
RJ12 connector
for Robot system
USB-B
connector
Equipotential
connection
Power Socket
Compatibility
* The MNE Nitrogen Flow Regulator is required.
**If you need to connect the MS, MV, MN or FS modules, an adapter is required (Ref. IM2496).
Select the equipment that best suit your soldering or desoldering needs.
Basic working system Peripherals**
Control
Unit Stand Tool Cartridge
Range
MSE-A /
MVE-A MNE-A FSE-A P-005
DDE-C
AD-SD
T210-A C210
T245-A C245
T470 -A C245
DN-SE
T210-NA* C210
T245-NA*
C245
T470 -NA*
AP-SD AP250-A C250
PA-SD PA120-A C120
HT-SD HT420-A C420
DS-SD DS360-A C360
DR-SD DR560-A C560
www.jbctools.com
3

350ºC
Port
2
Power
45%
T245
17:14
Selected 350ºC
Port
2
T245
17:14
Sleep
Tool in the stand
Actual Temp. 180ºC
Delay to hibernation: 29:30 Port
2
T245
17:14
Hibernation
Actual Temp. 25ºC
3. Hibernation
Operation
The JBC Exclusive Heating System
Our revolutionary technology is able to recover tip temperature extremely quickly. It means the user
can work at a lower temperature and improve the quality of soldering. The tip temperature is further
reduced thanks to the Sleep and Hibernation modes which increase the tip life by 5.
1. Work 2. Sleep
When the tool is lifted from the
stand the tip will heat up to the
selected temperature.
When the tool is in the stand,
the temperature falls to the
preset sleep temperature.
After longer periods of
inactivity, the power is cut off
and the tool cools down to
room temperature.
Tools Menu:
· Set temperature limits
· Select temperature levels
Tools Menu:
· Set Sleep temperature
· Set Sleep delay
(from 0 to 9 min or no Sleep)
Tools Menu:
· Set Hibernation delay
(from 0 to 60 min or no
hibernation)
Long time
in the stand
4

350ºC
Port
2
Power
45%
Temp. Levels
T245
250 350 380
17:14
USB flash drive is connected.
Station is controlled by a PC.
Station is controlled by a robot.
Station software update.
Press INFO to start the process.
Warning.
Press INFO for failure description.
Error. Press INFO for failure description,
the type of error and how to proceed.
System notifications (Status Bar)
Menu Options
Station
Information
Power
indicator
Tool
in use
Work Screen
Status bar
The DDE offers an intuitive user interface which provides quick access to station parameters.
Original PIN: 0105
Change
port
Displayed if
temperature
levels are
activated
Station Tools Counters
ResetGraphicsPeripherals
Press INFO for each parameter description.
www.jbctools.com
5

Port 1 - T245
450
400
350
300
250
150
100
50
200
Power Temp
17:14
By pressing Graphics in the main MENU, temperature and power figures in real
time are displayed for each port. This helps you decide which tip to use to obtain
the best quality solder joints.
Process analysis
Export graphics
Insert a USB flash drive into the USB-A connector
to save your soldering process in csv format.
Graphics
Temperature
Power (%)
See other
port graphic
6

Soldering Net
Remotely manage and monitor as many stations as your PC can handle.
Functions:
- Set all the station parameters from your PC.
- Organize groups of stations and set all their parameters at the same time.
- Store specific configurations for later uses.
- Analyze the soldering graphics of the stations on your PC and export them.
1. Download the JBC Manager software and the user manual from
www.jbctools.com/manager.html
2. Connect the stations via USB-B connector and the PC will automatically detect them.
3. The notification will be displayed on the station.
any JBC
station
USB Hub
JBC
Manager
software
www.jbctools.com
7

1. Connect the tool to the station port by means of the CHB-A Converter.
2. Connect your Robot system to the Robot connector (RJ12) of the station.
DB9-RJ12 Adapater available only if necessary (Ref: 0013772).
3. Enable the Robot option in the station settings and the notification will be displayed:
4. Set your Robot’s commands according to the Robot Communication Protocol, available on the
website www.jbctools.com/jbcsoftware-menu-115.html
Manage and monitor the station using a Robotic system.
Working with Robots
Update the station software
1. Download the JBC Update File from
www.jbctools.com/software.html and save
it on a USB flash drive. Preferably one with no
other files.
JBC
Update File
2. Insert the USB flash drive to the station.
The icon is diplayed while updating.
Control
Unit
Robot CHB-A
Converter
Ref. CHB-A
RS-232
connection
8

Clean periodically
Maintenance
Before carrying out maintenance or storage, always allow the equipment to cool.
- Clean the station screen with a glass cleaner or a damp cloth.
- Use a damp cloth to clean the casing and the
tool. Alcohol can only be used to clean the
metal parts.
- Periodically check that the metal parts of the
tool and stand are clean so that the station
can detect the tool status.
- Maintain tip surface clean and tinned prior to
storage in order to avoid tip oxidation.
Rusty and dirty surfaces reduce heat transfer
to the solder joint.
- Periodically check all cables and tubes.
Fuse holder
Fuse holder
Fuse
1. Pull off the fuse holder and remove the
fuse. If necessary use a tool to lever it off.
2. Press the new fuse into the fuse holder
and replace it in the station.
- Replace a blown fuse as follows:
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
www.jbctools.com
9

It is imperative to follow safety guidelines to prevent electric
shock, injury, fire or explosion.
- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Be sure that it is properly grounded
before use. When unplugging it, hold the plug, not the wire.
- Do not work on electrically live parts.
- The tool should be placed in the stand when not in use in order to activate the sleep mode.
The soldering tip, the metal part of the tool and the stand may still be hot even when the station
is turned off. Handle with care, including when adjusting the stand position.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Avoid the contact of flux with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when
working to avoid personal harm.
- Utmost care must be taken with liquid tin waste which can cause burns.
- This appliance can be used by children over the age of eight and also persons with reduced
physical, sensory or mental capabilities or lack of experience provided that they have been given
adequate supervision or instruction concerning use of the appliance and understand the hazards
involved. Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.
Safety
10

产品中有害物质的名称及含量
有害物质含量表
部件名称
有害物质
铅(Pb) 汞(Hg) 镉(Cd) 六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
烙铁头 O O O O O O
手柄 O O O O O O
电源线 O O O O O O
主机 O O O O O O
电源插座 O O O O O O
保险丝 O O O O O O
主开关 O O O O O O
电位连接 X O O O O O
变压器 O O O O O O
线路板 X O O O O O
O 表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572 规定的限量要求以下。
X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572 规定的限量要求。
www.jbctools.com
11

Exploded View
12

www.jbctools.com
13

Notes
14

www.jbctools.com
15

This product should not be thrown in the garbage.
In accordance with the European directive 2002/96/EC, electronic equipment at the end of their life
must be collected and returned to an authorized recycling facility.
Manual in other languages available on our website
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
Register your warranty within 30 days of purchase
in www.jbctools.com/productregistration
0 0 19 248 - 1117
Specifications
DDE-1C120V 50/60Hz. Input fuse: 4A. Output: 23,5V.
DDE-2C230V 50/60Hz. Input fuse: 2A. Output: 23,5V.
DDE-9C100V 50/60Hz. Input fuse: 5A. Output: 23,5V.
- Weight: 3,815 kg (8.41 lb)
- Dimensions: 148 x 120 x 232 mm (5.8 x 4.7 x 9.1 in)
- Output Peak Power: 150W per tool
- Temperature Range: 90 - 450 °C (190 - 840 °F) (±5%)
- Idle Temp. Stability (still air): ±1.5 ºC / ±3 ºF
- Tip to ground resistance: <2 ohms
- Tip to ground voltage: <2mV RMS
- Ambient operating temp: 10 - 40 ºC (50 - 104 ºF)
- Connections USB-A / USB-B / Peripherals connectors
RJ12 connector for Robot
Complies with CE standards.
ESD protected.
www.jbctools.com
This manual suits for next models
3
Table of contents
Other jbc Control Unit manuals