KOKEN LM-109FA User manual

Female
Catheterizationand
EnemaSimulator
(Strap-ontype)
LM-109FA
InstructionManual
ThankyouforpurchasingtheFemaleCatheterizationandEnemaSimulator(Strap-ontype).
Pleasereadthisinstructionmanualcarefullytoensurecorrectuseoftheproduct,
andstoreitinasafeplaceforeasyaccess.
KOKENCO.,LTD.
1-4-14Koraku,Bunkyo-ku,Tokyo112-0004JAPAN
URL:http://www.kokenmpc.co.jp
E-mail:[email protected]
©2018-2020KOKENCO.,LTD.C-1-1033-1-01-01

10000

1
Handling and Safety Precautions
These precautions should be strictly observed in order to ensure safe,
long-term use of the product.
The following precautions should be observed particularly strictly:
1. Thissimulatorismadetohavethesamefeelasthatofalivingbody.Unduehandlingmaycause
breakageofthesimulator.
2. Thismodelhasadistinctiveodorresultingfromthematerialsitismadefromhoweverisnot
harmfultothebodyorindicateanyproblemwithquality.Thisdistinctiveodorwillweakenover
time.Theproductisalsocoatedinbabypowderatthetimeofmanufactureandthesmellof
babypowdermayremainontheproduct.
3. Whenyoupracticecleaningordisinfectingofthepubicarea,pleaseusewater.Useofalcohol
maycausebreakageofthesimulator.
Useofcoloreddisinfectantliquidmaycausepigmenttobefixedtothesimulatorsothatthe
pigmentcannotberemoved.
4. Asforthelubricant,pleaseuseK-Ytmlubricatingjelly.PleasedonotuseK-Y®gel,asitmay
increasetheinsertionresistanceofthecatheter.
5. Pleasedonotuseoilylubricant(oliveoiletc.),alcohollubricant,andlubricantcontainingorganic
solvent.Thesemaycausebreakageofthesimulator.
6. Pleaseusecathetersof14Frand16Fr.
7. Pleasecheckthestateofthecatheterbeforeinsertingthecatheter.Pleasedonotuseacatheter
thatisdegradedordeformed.Suchacatheterisdiculttoinsert.
8.Wheninsertingthecatheter,pleaseapplythelubricanteachtime.
9. Ifitisdiculttoinsertthecatheter,pleaseincreasetheamountofthelubricanttobeapplied
oruseanothercatheter(firmsiliconecatheterorcatheterwiththinnerbaloonpartetc).The
simulatormaybreakifsuchacatheterisforcedtobeinserted.
10.Whenindwellingthecatheter,pleaseinflatetheballoonafterinsertingthecatheterapartfrom
theballoonendportionbyadistanceequaltoorgreaterthan4cm.Indwellingofthecatheter
inanintermediateofthevalvecausesthevalveandthecathetertobebroken.Pleaseprovidea
markeronthecatheterbeforecommencingtrainingtoensurethatthecathetertipisinsertedby
adistanceequaltoorgreaterthan4cmbeforeinflatingtheballoon.
4cm
Marker

2
11.Afteruse,pleasewashthesimulatorandthecatheterwellwithwater.Ifthelubricantdries
andhardens,itmayinterferewiththeuseofthesimulator.
12.Pleasecheckthestateofthevalveateveryuse.Ifthevalveisbroken,itmaycausealeakage
ofwater.
13.Oilcomponentsmaycomeoutofthegenitalskin.Afteruse,pleasedonotkeepthegenital
skinattachedtothesimulator.Pleasewrapitincookingpaper,gauze,etc.,putitintoan
attachedreclosablepolybag,andkeepit.Foradetailedstoragemethod,pleaserefertothe
washingandstoragemethodsonpage15.
14.Applycommerciallyavailablebabypowdertoreducefrictionifyoumindstickinessofthe
genitalskinorafteritiswashedwithwaterfollowinguse.
15.Thegenitalskinmaydeformovertime.Pleasecheckthestateofthegenitalskineverythree
yearsafterpurchase.Ifanydeformationthatcouldaffectthefunctionofthesimulatoris
found,considerreplacingitwithanewone.
16.Youmayobserveairbubblesordarkerareasinthegenitalskin.Thesewereformedduring
production;however,theydonotaectthestrengthofthegenitalskinbecauseitismadeof
amaterialresistanttotearing.
17.Pleasedonotplaceobjectsonthesimulator.Otherwise,thesimulatormaybedeformed.
18.Pleasedonotkeepthesimulatorincontactwithprintedmatter.Print,suchasletters,may
transfertothesimulatorandbexedthere.
19.Whenstoringthesimulator,pleaseselectaplacethatisnotsubjecttodirectsunlightand
ultravioletrays.
20.Thisproductisintendedforuseinstandardoperatingenvironments.Donotuseitinheavy
industrialsettings.
21.Thismodelusesurethanefoamforsomeofitsparts,andmaybesusceptibletodamagefrom
peststhatareattractedtourethanefoam(suchasinsectsintheantfamily).
Whenstoringthismodel,ensurethatthoroughmeasuresaretakentopreventpestdamage
beforestoring.Thecompanywillnotbeinvolvedwithorheldliableforpestdamagethat
occursduringstorage.
1.Thecontentsofthisinstructionmanualaresubjecttochangewithoutnotice.
2.Thisinstructionmanualmaynotbereproducedinpartorinitsentiretywithoutpermission.
3.Pleasecontactthemanufacturerintheeventthatanyerrorsoromissionsarefoundinthecontentsof
thisinstructionmanual.
4.Thisproductshouldbeusedonlyasdescribedinthisinstructionmanual.Inparticular,theproduct
shouldnotbeusedinanywaythatcontravenestheprecautionsnotedintheinstructionmanual.

3
Table of Contents
1. Outline and Features
2. Components and Conguration
3. Handling Method
4. Washing and Storage Methods
5. Specications
6. Replacement Parts (Sold Separately)

4
1. Outline and Features
Outline
Thesimulatorcanbemountedonahumanbodyoradollsothataseriesoftechniquesregarding
catheterizationandenemacanbepracticed.Thefeelofthelabiaandresistanceofthecatheterto
itsinsertionarecloselysimilartothatofalivingbody.Ifacatheterizationcatheterisappropriately
inserted,urine(water)flowsout.
Features
・Thesimulatorisofanactualsizebywhichacatheterizationandglycerineenemaforanadult
femalecanbepracticed.
・Sincethesimulatorisofastrap-ontype,itcanbemountedonahumanbodyoramodeldoll
sothatthepracticecanbeperformed.
・Bymountingthesimulatoronahumanbody,thefeelingofapatientcanbesimulated.
Also,bymountingthesimulatoronasimulationpatient,techniquescanbepracticedwhile
communicatingwiththesimulationpatient.
・Sincesoftandstretchablematerialsareusedforthepubicarea,theappearanceandfeelare
realistictogivepresencewhenpracticing.
・Aseriesoftechniquesofcatheterizationsuchasdisinfectingofapubicarea,andinsertingand
removingofacathetercanbepracticed.
・Cleaningtechniquescanbeperformed.
・Theattachedglycerineenematorcanbeinsertedthroughtheanustotherectum.Thisenables
thepracticefortheglycerineenema.

5
2. Components and Con guration
1. FemaleUrethralpart
2. FemaleGenitalskin
3. BladderValve(Male/Female)
4. O-ring
5. Strap-ontypeframe(withbelt)
6. Femalestrap-ontypebladdertube
7. Strap-ontyperectumconnectingconnector
8. Bagforirrigator
9. Tubeforirrigator
10.Draintube
11. Glycerineenemator
Storagebag
Instructionsmanual(thispamphlet)

6
3. Handling Method
3-1AssemblingofSimulator
1. Pleaseconnectthebagforirrigatortothefemalestrap-ontypebladdertube,andputwater
intothebagforirrigator.Pleaseopenaclamp,llthefemalestrap-ontypebladdertube
withwater,closetheclamp,andattachthebladdervalvetothebagforirrigator.
2.Pleaseinsertthefemalestrap-ontypebladdertubeintothestrap-ontypeframe.

7
3.PleaseinserttheO-ringintotheconnectorofthefemaleurethralpart.
4. Pleaseconnectthefemaleurethralpartandthefemalestrap-ontypebladdertubewhile
adjustingtheirpositionssothatthefemaleurethralpartisxedintheopeningofthe
strap-ontypeframe.
5.Pleaseinsertthestrap-ontyperectumconnectingconnectorintothestrap-ontypeframe.

8
6.Pleaseconnectthestrap-ontyperectumconnectingconnectortothedraintube.
7. Pleaseputtheanalportionofthefemalegenitalskinonthestrap-ontyperectum
connectingconnector.Aftertheconnectorisinserteddeepintotheanalportion,pleaset
andxthepositionofthefemalegenitalskintothestrap-ontypeframe.
8.Pleaseinserttheprojectionofthefemaleurethralpartintotheurethralcanallocatedonthe
reversesideofthefemalegenitalskinsothattheprojectioniscovered.Thenxthefemale
urethralpartandthefemalegenitalskinwithhookandloopfasteners.
9.Pleaseattachandxthepositionofthefemalegenitalskintothestrap-ontypeframe.
Projectionofthefemaleurethralpart

9
3-2WearingMethod
1.Pleaseremovethefrontbeltandrearbeltfromthewaistbelt.
2.Pleasewearthewaistbeltandadjusttheadjusteraccordingtowaistsize.
3.Pleasepasstherearbeltthroughthewaistbelt,andtandxthepositionofthepubicarea
withhookandloopfasteners.
Waistbelt
Frontbelt
Rearbelt

10
4. Pleasepassthefrontbeltthroughthewaistbelt,andxitwithhookandloopfastenerssuch
thatthebeltsdonotcomeloose.
5.Whenperforminganenematechnique,pleaseremovethefrontbeltonce,tthepositionof
theanustothebody,andadjustthelengthoftherearbeltrst.
theanustothebody,andadjustthelengthoftherearbeltrst.
Positionofthemodel
duringenema
Pleaseadjustthepositionoftheanusonthepersonwho(orthedollthat)has
putonthismodeltothepositionoftheanusofthemodel.
Pleaseadjustthepositionoftheurethralcanalonthepersonwho(orthedoll
that)hasputonthismodeltothepositionoftheurethralcanalofthemodel.
Positionofthemodel
duringcatheterization

11
3-3InsertionofCatheterizationCatheter
1.Pleaseopentheclampforirrigatortubeandcheckwhetherornotthewaterleaksfromthe
simulator.
*Whenpracticingthecleaningordisinfectingofthepubicarea,pleaseusewaterinsteadof
disinfectionliquid.
2.Pleaseapplylubricantonthedistalendofthecatheterforabout4to5cmandinsertthe
catheter.
*Ifitisdiculttoinsertthecatheter,pleasecheckthetechniquesandinsertitagain.Inthis
case,pleaseremovemoisturefromthecatheterandincreasetheamountofthelubricant
tobeapplied.Also,pleaseconsiderusingothertypesofcatheters(rmsiliconecatheteror
catheterwiththinnerbaloonpartetc).Thesimulatormaybebrokenifhecatheterisforced
tobeinserted.
*Ifitisdiculttoinsertthecatheter,pleaseusewatermixedwithasmallamount
(approx5%)ofsurfactant(neutraldetergent)asurine.
*Iftheinsertionofthecatheterisrepeatedapluralityoftimes,watermayaccumulateinthe
urethralcanal.
3. Pleasechecktheoutflowoftheurine(water).Ifurinedoesnotflowout,checkthefollowing:
-Whetherthecatheterpassesthroughthevalve;
-Whethertheclampforirrigatortubeisopen;and
-Theamountofwaterinthebagforirrigatorisreducedtoasmallamount.
4.Whenindwellingthecatheter,pleaseinflatetheballoonafterinsertingthecatheterapart
fromtheballoonendportionbyadistanceequaltoorgreaterthan4cm.Indwellingofthe
catheterinanintermediateofthevalvecausesthevalveandthecathetertobebroken.Please
provideamarkeronthecatheterbeforecommencingtrainingtoensurethatthecathetertip
isinsertedbyadistanceequaltoorgreaterthan4cmbeforeinflatingtheballoon.
4cm
Marker

12
5.Oncethecatheterisinserted,pleaseremovethemoisturefromitswettip,applythelubricant
eachtime,andtheninsertthecatheter.Ifthelubricantisappliedwherewaterremains,the
lubricantslideseasilyoofthecatheter.Thismakesitdiculttoinsertthecatheter.
3-4Enema
1. Pleaseprepareabucketetc.underadeskorabedandputthedistalendofthedraintubeinit.
2.Pleasetandxthepositionoftheanusofthestrap-ontypeframetothebody,andadjustthe
lengthofthebelt.
PleaserefertothepositionofthemodelduringenemaasshownintheFigureinSection3-2(5)
onpage10.
3.Pleaseapplylubricanttothedistalendofaglycerineenemator,insertitintotheanus,andpour
enemaliquid(water)intoit.Atthistime,pleaselowerthedistalendofthedraintubetoa
positionbelowtheanus.Otherwise,theenemaliquid(water)mayflowbackwardandstain
clothing.
3-5Removal
1. Pleaseclosetheclampofthebagforirrigator.
2.Pleaseremovethebeltsandthestrap-ontypeframe,andthenremovethedraintubefrom
thestrap-ontyperectumconnectingconnector.
*Pleasepayattentiontotheoutflowofthewater.

13
3.Pleaseremovethefemalegenitalskinfromthestrap-ontypeframewiththefemale
urethralpart,thefemalestrap-ontypebladdertube,andthestrap-ontyperectum
connectingconnectorconnected.Atthistime,pleaseremoveslowlywhileholdingthearea
ofthehookandloopfastenersothatitdoesnotpeelofromthefemalegenitalskin.
4.Pleaseremovethestrap-ontyperectumconnectingconnectorfromthefemalegenitalskin.
5.Pleaseremovethefemaleurethralpartfromthefemalegenitalskin.
Atthistime,pleaseremoveslowlywhileholdingtheareaofthehookandloopfastenerso
thatitdoesnotpeelofromthefemalegenitalskin.

14
6.Pleaseremovetheconnectorforconnectingthefemaleurethralpartandthefemalestrap-on
typebladdertube.
*Atthistime,pleasepayattentiontoalossoftheO-ring.
7. Pleaseremovethebladdervalvefromthefemalestrap-ontypebladdertube,anddrainthe
waterinthetube.
8.Pleasewashthefemaleurethralpart,thebladdervalve,thefemalestrap-ontypebladder
tube,thefemalegenitalskin,andthestrap-ontyperectumconnectingconnectorwellwith
waterafteruse.

15
4. Washing and Storage Methods
1. Pleaseflushthelubricantthathasadheredtothefemaleurethralpart,thebladdervalve,the
femalestrap-ontypebladdertube,etc.wellwithwater.Ifthelubricantdriesandhardens,it
mayinterferewiththeuseofthesimulator.
2.Pleaseremovemoisturewell,drythesimulatorandthenputitintoastoragebag.
3. Oilcomponentsmaycomeoutofthefemalegenitalskin.Afterusingthesimulator,pleasedo
notkeepthefemalegenitalskinattachedtothemainbody.Pleasewrapitincooking
paper,gauze,etc.,putitintoanattachedreclosablepolybag,andkeepittherein.Pleasewrap
thefemalegenitalskingentlysuchthatwrinklesarenotgeneratedonit.
4.Pleaseapplybabypowderthatiscommerciallyavailable,ifyoumindstickinessofthe
femalegenitalskin.
5. Asforstainsonthesimulator,pleaseuseneutraldetergentthatiswatereddownandwipe
othestainswithwetgauzeetc.
*Pleasedonotusesolventssuchasthinnerandbenzene.

16
5. Specications
6. Replacement Parts (Sold Separately)
Length Width Height Weight
MainBody
StorageBag
Approx.23cm Approx.13cm Approx.11cm Approx.0.6kg
Approx.21cm Approx.47cm Approx.24cm
Productname
Bagforirrigator(3pcs/set) LM-025J
Tubeforirrigator(3pcs/set) LM-025H
Productname ProductNo.
FemaleGenitalskin LM-109FB
BladderValve(Male/Female)(3pcs/set) LM-109V
Glycerineenemator(withcap/5pcs) LM-0686
Table of contents
Other KOKEN Science Education Product manuals

KOKEN
KOKEN LM-017 User manual

KOKEN
KOKEN Maternity Model Type II User manual

KOKEN
KOKEN LM030 User manual

KOKEN
KOKEN LM-110 User manual

KOKEN
KOKEN LM-068 User manual

KOKEN
KOKEN LM-101D User manual

KOKEN
KOKEN LM-104 User manual

KOKEN
KOKEN Western Features Baby User manual

KOKEN
KOKEN LM-113A User manual

KOKEN
KOKEN LM-101K User manual
Popular Science Education Product manuals by other brands

PASCO
PASCO EM-3536 instruction manual

National Instruments
National Instruments NI ELVIS quick start guide

3D Molecular Designs
3D Molecular Designs ENZYMES IN ACTION KIT 12-Group Set manual

Green Science
Green Science Solar Science manual

Thames & Kosmos
Thames & Kosmos Electronics Experiment manual

Life form
Life form LF01040U instruction manual