01
Please read and understand the manufacturer's instructions for each component or part of the complete system. Manufacturer's instructions
must be followed for proper use, care, and maintenance of this product. These instructions must be retained and be kept available for the user's
reference at all times. Alterations or misuse of this product, or failure to follow instructions, may result in serious injury or death.
Note: The user is advised to keep this user instructions document for the life of the product.
1. INTRODUCTION: The Edge Single point anchor is classed as a Personnel Protective Equipment (PPE) by the European PPE
Regulation (EU)2016/425 and has been shown to comply with this Regulation through the Harmonized European Standard EN
795:2012 type A.
This Anchor is designed to minimize the risk of/provide protection against the danger of falling from heights. However, always remember
that no item of PPE can provide full protection and care must always be taken while carrying out the risk related activity.
2. PERFORMANCE AND LIMITATIONS OF USE:
The Anchor has been tested in accordance with EN 795:2012 type A and has achieved the following performance levels-
EN 795:2012 Type A test
General Requirements
for Anchor devices
(Clause 4.2)
Static Strength
(Clause 4.4.1.3)
Dynamic Strength &
Integrity Test
(Clause 4.4.1.2)
Corrosion Resistance
(Clause 4.7)
(PASS)
No sharp edges (PASS).
Sustained a force of 12 kN for 3 minutes (PASS).
When tested with rigid steel mass of 100 kg, the test mass held after test with the
device remaining stable throughout. (PASS)
Anchor Holds an increased load of 300kg for 3 min following dynamic test.
No corrosion evident after 48 hours of salt spray testing. (PASS)
Result/Comment
4. INSTRUCTIONS FOR USAGE :
Single Point Anchor is to be used for anchorage in a fall arrest system.
This anchor can be fixed to walls, ceilings, roof tops or steel structures present
in the working environment.
For fixing to steel structures, drill one hole of dia 12.5mm in the steel
structure (pass through) and bolt the anchor on to it by using one M 12
steel nut bolts. Ensure that the nut & bolt is tightened enough & not loose.
For fixing to walls, ceiling and roof tops, fix only on ones made up of
concrete and known to have compression strength of at least 3000 PSI.
Use one M12 chemical fastener to be fixed in the drill made in to the
concrete structure as per specification stated by the chemical fastener
manufacture.
The Anchor can be fixed so that the load impact is in any of the directions
shown in the adjacent figure:-
Ÿ
Ÿ
3. INSPECTION:
inspection, doubts are raised about the safety of the system or a component, these should be replaced either by the manufacturer or a
competent person.
Visually inspect the system before each use to enusre that it is in a serviceable condition and is operating correctly. If during