Base Setup
Use the navigation key to proceed to the final step.
• To save and apply the new Base Station settings select
Save and press to confirm.
Configure the Raw Data Logging
• Navigate to the Setting icon in the main menu
• Following into Tools > Raw Data Logging
-In Raw Data Logging follow into Setup/Start
Logging
-In Set up logging (1), enter in the appropriate
height, and use the correct Measure format.
-In Set up logging (2), enter in the any unique Point
ID, set the Interval as: 1s, set Method as: Manual
Stop, At power Cycle: Resume
-In Set up logging (3), Split files: No
• Upon hitting right arrow after set up logging 3), logging
will commence.
Exit Raw Data Logging and make sure “Exit – Continue
Logging” is entered
Main Display
Screen
In the main display screen verify the following:
The Position Icon
-This icon means the receiver is correctly setup as
a base.
The Radio Icon:
-Although there is no physical radio involved, but
the icon shows that the P1 port 1) is streaming
correction out.
Lastly, make sure the receiver is tracking with enough
satellites in an open area free of canopy/obstructions) in
order to achieve an optimal position.