manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Leviton
  6. •
  7. Accessories
  8. •
  9. Leviton Decora ODS06 Operation manual

Leviton Decora ODS06 Operation manual

PRODUCT DATA
ODS06
Leviton Mfg. Co., Inc. Lighting & Energy Solutions
201 N. Service Rd. Melville, NY 11747-3138 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com/les
© 2014 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
ODS06
Decora®Wall Switch PIR
Occupancy Sensor
BASIC OPERATION
The Leviton ODS06 Decora®Wall Switch
Occupancy Sensor uses Passive Infrared (PIR)
detection technology to monitor a room for
occupancy through a segmented Fresnel lens.
This specialized lens divides the field-of-view
into sensor zones. When a person passes into
or out of a sensor zone, the sensor detects
motion and switches the lights ON. The lights
will remain ON as long as there is an occupant
moving through the sensor zones.
A delayed-OFF time adjustment prevents the
lights from switching OFF when the space is
occupied. In order to keep the lights ON, a
person must pass through a sensor zone at
least once during the selected delayed-OFF
time interval. An LED indicator blinks each time
the unit detects activity in the sensor zones.
When the space being monitored by the sensor
is unoccupied for the length of time chosen as
the delayed-OFF interval, the sensor will turn
the lights OFF.
APPLICATIONS
The ODS06 PIR Occupancy Sensor is used to
provide automatic lighting control for energy
savings and convenience in a variety of com-
mercial applications including:
• Small offices
• Conference rooms
• Lounges
The ODS06 can be used for automatic switch-
ing of LED, incandescent lamps and fluores-
cent and low-voltage lighting with electronic
or magnetic ballasts. The unit also features
a manual override switch that can be used
to keep lights OFF while an area is occupied,
which may be desired in conference rooms and
other areas during slide or film presentations.
The unit installs in place of a single-pole wall
switch and fits in a standard wall box. The unit
requires a ground connection.
• Specifically designed to meet the
commercial needs of LED load requirements
• Industry exclusive High Inrush Stability
(H.I.S.) circuitry for extended durability
• Industry exclusive dual PIR sensors provide
optimum sensitivity and expanded occu-
pancy detection
PRODUCT DATA
ODS06
FEATURES
•Fits in standard wallbox and replaces single-pole
wall switch. Gangable with other units.
•Low-profile design eliminates obtrusive appear-
ance. Elegant Decora wallplates complement
any interior for sleek aesthetics; uses Decora
wallplates and coordinates with Leviton’s popu-
lar line of Decora wiring devices.
•180° field-of-view provides approximately 1600
square feet (149 square meters) of coverage
suitable for small offices, conference rooms,
lounges and a variety of commercial areas.
•Convenient pushbutton provides manual-ON/
OFF light switching at any time.
• Two dual element PIR sensors used to widen
detection range.
• Vandal resistant PIR lens.
• Patented Blinders - horizontal field-of-view may
be adjusted between 180° and 180° of arc by
using integral blinders located on either side of
the lens. No masking tape required.
•Manual-ON/Auto-OFF mode for installations
where manual-ON switching is required but
auto-OFF switching is still desired for CA Title 24
energy savings.
•To comply with CA Title 24, red LED indicator
light flashes when sensor detects motion to
verify detection is active.
• Time Delay adjustment for delayed-OFF time
settings of 30 seconds (for walking test), 10
minutes, 20 minutes, and 30 minutes. Allows
customized adjustments to maximize energy
savings.
• Vacancy confirmation - when the time out
expires and the lights turn OFF a 30 second
vacancy confirmation exists to turn the lights
back ON.
• Presentation Mode feature for slide or film pre-
sentations allows push buttons to turn lights
OFF and keep them OFF while the room is occu-
pied.
•One unit can be used for 120-230-277V lighting.
Compatible with LED drivers and electronic and
magnetic ballasts.
• No neutral design is optimal for retrofit applica-
tions.
ODS06
Field-of-View (in feet)
TOP VIEW
SIDE VIEW
15
0
0
15
15
30
30
40
40
4
Minor Motion, IR
Major Motion, IR
5
030
FIELD-OF-VIEW
The ODS06 provides a 180° field-of-view with a
maximum coverage area of approximately 1600
square feet (149 square meters). The maximum
sensing distance in front of the sensor is 30 feet
(3square meters), and at each side is 30 feet. A
“minor motion” zone detects relatively small body
movements and allows the lights to stay ON even
though a person may not be moving or walking
around the room. The remainder of the field-of-
view, the “major motion” zone, exhibits a lesser
degree of sensitivity and requires larger move-
ments.
ODS06
Leviton Mfg. Co., Inc. Lighting & Energy Solutions
201 N. Service Rd. Melville, NY 11747-3138 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com/les
© 2014 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
ODS06 Wall Switch Occupancy Sensor Wiring
Diagram, Single Location Control
ODS06 Wall Switch Occupancy Sensor Wiring
Diagram, Multi-Location Control
Hot (Black)
Load
ODS06
Black
Green
Ground
Blue
Line
120-130-277VAC,
50/60Hz
Neutral (White)
Black
White
Note: Ground must be connected
WIRING DIAGRAM
DIMENSIONAL DIAGRAMS
1.75”
(44.4 mm)
1.30”
(33.0 mm)
2.61”
(66.3 mm)
4.06”
(103.2 mm)
0.48”
(12.6 mm)
1.35”
(34.4 mm)
2.60”
(66.2 mm)
BLINDERS
RANGE
TIME LIGHT
12
3
4 7
10
4 7
10
Mounting Yoke
Vandal Resistant
PIR Lens
Patented
Blinders
LED Window and
Light Sensor
Push Button
Control Panel,
Cover Removed
Hot (Black)
Load
ODS06
Black
Green
Ground
Blue
Blue
Green
Ground
Line
120-230-277VAC,
50/60Hz
Neutral (White)
Black White
Black
Note: Ground must be connected
PRODUCT DATA
Leviton Mfg. Co., Inc. Lighting & Energy Solutions
201 N. Service Rd. Melville, NY 11747-3138 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com/les
Leviton Manufacturing of Canada, Ltd.
165 Hymus Boulevard, Pointe Claire, Quebec H9R1E9 • Telephone: 1-800-469-7890 • FAX: 1-800-563-1853
Leviton S. de R.L. de C.V.
Lago Tana 43, Mexico DF, Mexico CP 11290 • Tel. (+52) 55-5082-1040 • FAX (+52) 5386-1797 • www.leviton.com.mx
Visit our Website at: www.leviton.com/les
© 2014 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
ODS06
ELECTRICAL
Line Voltage 120-230-277 VAC
Operational
Frequency
50/60Hz
Wire
Designation
Line - Black, Load - Blue,
Ground - Green
No neutral required
Load Rating Fluorescent: 800VA @ 120V
1500VA @ 277V
Incandescent: 600W @ 120V
Motor: 1/4 HP @ 120V
ENVIRONMENTAL
Operating
Temperature
Range
32°F to 122°F (0°C to 50°C)
Storage
Temperature
Range
14°F to 185°F (-10°C to 85°C)
Relative
Humidity
20% to 90% non-condensing
OTHER
Listings cULus, CA Title 24 compliant,
Complies with FCC Regulations,
NOM Certified
Warranty Limited Five-Year Warranty
To indicate color, add suffix to the end of the catalog number
White (-W) , Ivory (-I)
ORDERING INFORMATION
CAT. NO. DESCRIPTION
ODS06-INx Decora PIR Wall Switch Occupancy
Sensor, NAFTA compliant
ODS06-IDx Decora PIR Wall Switch Occupancy
Sensor
G-8534B/F14-aa
INSTALLATION
The ODS06 may replace a single-pole wall switch
mounted in a standard wallbox. The unit must be
properly grounded in order to operate. The unit’s
integral blinders may be used to restrict the field-
of-view to prevent unwanted detection of hallway
traffic. It should be positioned at least 6 feet away
from HVAC registers. Note that whenever the unit
is powered up, it will take approximately one min-
ute to begin normal operation.

Other Leviton Accessories manuals

Leviton OSFHS-IxW User manual

Leviton

Leviton OSFHS-IxW User manual

Leviton OSC05-M0W User manual

Leviton

Leviton OSC05-M0W User manual

Leviton DECORA ODS0D-TDW User manual

Leviton

Leviton DECORA ODS0D-TDW User manual

Leviton OSC04-R User manual

Leviton

Leviton OSC04-R User manual

Leviton GreenMax OSR05-IC Series User manual

Leviton

Leviton GreenMax OSR05-IC Series User manual

Leviton DECORA ODS10-IDI User manual

Leviton

Leviton DECORA ODS10-IDI User manual

Leviton ODC10-MDW User manual

Leviton

Leviton ODC10-MDW User manual

Leviton ODS15-I1 User manual

Leviton

Leviton ODS15-I1 User manual

Leviton OSS10-IDx User manual

Leviton

Leviton OSS10-IDx User manual

Leviton DOD05 User manual

Leviton

Leviton DOD05 User manual

Leviton OFDUZ User manual

Leviton

Leviton OFDUZ User manual

Leviton ODC15-IDW User manual

Leviton

Leviton ODC15-IDW User manual

Leviton ZW15R User manual

Leviton

Leviton ZW15R User manual

Leviton renu RER15 User manual

Leviton

Leviton renu RER15 User manual

Leviton ODP10-I1W User manual

Leviton

Leviton ODP10-I1W User manual

Leviton OSW12-M0W User manual

Leviton

Leviton OSW12-M0W User manual

Leviton Intellect ZL00J-T02 User manual

Leviton

Leviton Intellect ZL00J-T02 User manual

Leviton ODS15-ID User manual

Leviton

Leviton ODS15-ID User manual

Leviton 31A00-8 User manual

Leviton

Leviton 31A00-8 User manual

Leviton OSW12-MNW User manual

Leviton

Leviton OSW12-MNW User manual

Leviton D4200 User manual

Leviton

Leviton D4200 User manual

Leviton ODSOD-ID Owner's manual

Leviton

Leviton ODSOD-ID Owner's manual

Leviton OSC20-MOW User manual

Leviton

Leviton OSC20-MOW User manual

Leviton ACENTI User manual

Leviton

Leviton ACENTI User manual

Popular Accessories manuals by other brands

Apogee Instruments SQ-422X owner's manual

Apogee Instruments

Apogee Instruments SQ-422X owner's manual

Palram FERIA 3x3.05m/10 instructions

Palram

Palram FERIA 3x3.05m/10 instructions

NTI ENVIROMUX-STSP-7 installation manual

NTI

NTI ENVIROMUX-STSP-7 installation manual

Dimplex DCEVP5BW instruction manual

Dimplex

Dimplex DCEVP5BW instruction manual

LG M160 quick start guide

LG

LG M160 quick start guide

Arrow verical Vishay TSSP60 Series manual

Arrow

Arrow verical Vishay TSSP60 Series manual

Turbo E9Trb Use and maintenance instructions

Turbo

Turbo E9Trb Use and maintenance instructions

Direct Supply Attendant owner's manual

Direct Supply

Direct Supply Attendant owner's manual

Orion Atlas Pro AZ/EQ-G GoTo Mount instruction manual

Orion

Orion Atlas Pro AZ/EQ-G GoTo Mount instruction manual

Keyscaper KPBK6K product manual

Keyscaper

Keyscaper KPBK6K product manual

SOMFY animeo installation guide

SOMFY

SOMFY animeo installation guide

Kemo Electronic B192 quick start guide

Kemo Electronic

Kemo Electronic B192 quick start guide

Roland DUO-CAPTURE EX owner's manual

Roland

Roland DUO-CAPTURE EX owner's manual

bca FLOAT instructions

bca

bca FLOAT instructions

Audiophile Systems Audiophile 192 user guide

Audiophile Systems

Audiophile Systems Audiophile 192 user guide

Froggit DP30 manual

Froggit

Froggit DP30 manual

Garland ECO parts list

Garland

Garland ECO parts list

Turnils Ibiza Installation

Turnils

Turnils Ibiza Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.