INSTALLATION
WARNINGS & CAUTIONS:
• TOBEINSTALLEDAND/ORUSEDINACCORDANCEWITHELECTRICALCODESANDREGULATIONS.
• INSTALLATIONOFCAT.NOS.51120-1AND51120-3SPDDEVICESINABRANCHCIRCUITMUSTBEDONEBYANELECTRICIAN.
• READALLINSTRUCTIONSBEFOREINSTALLING.
• CAT.NOS.51120-1AND51120-3SPDDEVICESMUSTBEINSTALLEDONALINETHATISSERVEDBYDISCONNECTMEANS,SUCHAS20-AMPCIRCUITBREAKERSOR20-AMP
FUSEDDISCONNECTSWITCHES.
• SPDMAYNOTSURVIVESUSTAINEDOVERVOLTAGES.
• USETHISDEVICEONLY WITH COPPER OR COPPER CLAD WIRE.
FEATURES:
• UL1449Listed-Type2SPD
• IEEEC62.41-1991categoryA&Bcombinationwavesuppression
• Solid-statesemiconductorSPDcircuitryforeachphase
• Eachphaseindependentlyfused
• GreenLEDdiagnosticindicatorforeachphase
• NEMA1metalenclosure
• Pre-punchedstandardknockouts
• Interiorplasticcircuitenclosureforaddedsafety
• Flushmountingenclosure
ForsuperiorlocalSPDprotection,useLevitonSurgeSuppressionOutletstoprotectagainstinternally-generatedtransientsbetweenthebranchpanelandthepointofuse.
DESCRIPTION:
Leviton’sCatalogNos.51120-1(120/240V,single-phaseversion)andthe51120-3(120/208V,3-phaseversion)BranchPanelMountedSPDdeviceshavebeendesignedtoprotect
residentialandsmallcommercialestablishmentsfromhighvoltagetransients.ThestandardJ-Boxmetalenclosurewithpre-punchedstandardsizeknockoutssimpliesush
mountingintypicalframeconstructionenvironments,andprovidesconvenientconnectionmeanstoexistingbranchpanels.
TO INSTALL:
System Voltage Requirements
1. Measurepanelvoltage,L-N,todeterminethesystemvoltage.SystemvoltagemustnotexceedthespeciedmaximumcontinuousRMSvoltageontheSPDdevicelabel.
Location and Mounting
1. LocatetheSPDdeviceascloseaspossibletothebranchcircuitbreakerpanel.ConnectionleadlengthbetweentheSPDdeviceandcircuitbreakerboxshouldbeminimalfor
bestprotection.ThelocationshouldalsopermitgoodvisibilityoftheSPDdevice’sdiagnosticlights.
2. Removethecircuitbreakerpanelcoveranddeterminethebreaker-panelwiringentrypointrelativetochosenlocationoftheSPDdevice.
NOTE:SincethecircuitbreakerpanelandtheSPDunithaveoverlappingcovers,installationshouldallowatleastoneinchofclearancefromtheedgeofthecircuitbreaker
panelcover.
3. Forsurface-mountcircuitbreakerpanels,theSPDdevicemaybeconnectedusingrigidconduittoanyconduitknockouthole.
4. Fornon-surfacemountinstallations,securetheSPDtothesupportstudinthewallbycuttinga6x6-inchmountinghole.
5. RemoveSPD’scoverandconnect3/4-inchexibleorrigidconduitbetweencircuitbreakerboxandtheSPD.
6. PlacetheSPDdeviceintothe6x6-inchmountingholeandsecureittotheexposedstuds.
Wiring Connections
TheSPDdeviceterminalblockaccepts4AWG–12AWGCOPPERWIREONLY.ForwirerangeSolidorStranded12AWGto10AWGuseTorque25in-lbs.For8AWGStranded
wireuse30in-lbs.ForStranded6AWG–4AWGuse35in-lbs.
1.
WARNING:TOAVOIDFIRE,SHOCKORDEATH,TURN OFF POWERATCIRCUITBREAKERORFUSEANDTESTTHATPOWERISOFFBEFOREWIRING!
2. Connectwireleadstoterminalblock:BLACKtoPHASES,WHITEtoNEUTRALandGREENtoGROUND.SeeFigures 1through4onreverseside.
CAUTION:Ifplasticconduitisused,Greengroundwiremustbeconnectedtogroundlug,andGreenwireinsideenclosuremustalsobeconnectedtogroundlug.Failuretodo
somayresultinreorshock.SeeFig. 1,Fig. 2,Fig. 3andFig. 4onreversesideforinstallationdiagrams.
3. ThreadtheSPDdevice’swireleadsthroughtheconduittocircuitbreakerinterior.
4. SecuretheSPDcoverwiththescrewsremovedpreviously.
5. Selectcircuitbreakersascloseaspossibletoeachserviceentrancelug.Twenty-Amp(20A)circuitbreakersarerecommended,andmayshareSPDdeviceandbranchcircuit
leads.ThebreakersprovideadditionalfailureprotectionaswellasaSPDconnectionandservicingdisconnect.
NOTE:DonotconnectSPDleadsdirectlytoserviceentrancelugs.Thismayresultinre,shockordeath.
6. Leadlengthsshouldbeasshortaspossible.ConnecttheBLACKleadstoeachPHASEthroughtheselectedcircuitbreakers.ConnecttheWHITEleadtoNEUTRALascloseas
possibletoNEUTRALentranceservicelug.
NOTE: Avoidlongloopsanddonotcoilextraleadwire.
7. Replacethecircuitbreakerpanelcover.Installationiscomplete.
Power ON
1. Restorepowertocircuitbreakerpanel.ThegreendiagnosticlightsontheSPDdeviceshouldturnON.
2. Ifduringnormaloperationadiagnosticlightshutsoff,haveanelectriciandetermineifphasepowerisapplied.Ifpowerispresent,thenatransientsurgehasexceededtheSPD
device’srating.Theunitshouldbereplacedand/orupgradedassoonaspossible.
BRANCH PANEL MOUNTED SURGE PROTECTIVE DEVICE (SPD)
Cat. Nos. 51120-1&51120-3
DI-000-51120-00E
©2010LevitonMfg.Co.,Inc. DI-000-51120-00E
120 V
120 V
240 V
120/240 V
1
Ø
51120-1
L1
N
L2
Suitable for use on a circuit capable of delivering no more than 10,000
rms symmetrical amperes, 120 volts maximum when protected by a 20
ampere circuit breaker rated 120 volts minimum. The interrupting rating of
the fuse or circuit breaker shall not be less than the available fault current.
FIGURE 1 - SINGLE-PHASE INSTALLATION
Suitable for use on a circuit capable of delivering no more than 10,000
rms symmetrical amperes, 120 volts maximum when protected by a 20
ampere circuit breaker rated 120 volts minimum. The interrupting rating of
the fuse or circuit breaker shall not be less than the available fault current.
208 V
208 V
120 V
120 V
120 V
208 V
L3
L2
L1
N120/208 V
3
Ø
51120-3
FIGURE 2 - THREE-PHASE INSTALLATION
G
L1
L2
N
20
20
20
20
40
20
20
20
20
40
Flexible Conduit
to J-Box
Circuit Breaker Panel
(Cover Removed)
51120-1
FIGURE 3 - SINGLE-PHASE WIRING
Flexible Conduit
to J-Box
Circuit Breaker Panel
(Cover Removed)
51120-3
G
L1
L2
L3
N
20
20
20
20
40
20
20
20
20
40
FIGURE 4 - THREE-PHASE WIRING
LIMITED LIFETIME WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benet of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under
normal and proper use during the lifetime of the product. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if the product is returned prepaid, with proof of
purchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, N.Y. 11747.Thiswarrantyexcludesand
there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including
merchantabilityandtnessforaparticularpurpose.Levitonisnotliableforincidental,indirect,special,orconsequentialdamages,includingwithoutlimitation,damageto,orlossofuseof,anyequipment,
lost sales or prots or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
ARTWORK PRINT SPECIFICATIONS
PART NUMBER REV DESCRIPTION
Line Screen:
Angle:
Resolution:
Offset Flexo
Other
Body Material:
Bindery
Thickness:
Trim
Perfect Bind
Die cut Saddle Stitch
Drill
Fold
The information in this document is the exclusive PROPRIETARY property of LEVITON MANUFACTURING COMPANY, INC. It is disclosed
with the understanding that acceptance or review by the recipient constitues an undertaking by the recipient. (1) to hold this information in strict
confidence, and (2) not to disclose, duplicate, copy, modify or use the information for any pupose other than that for which disclosed.
© 2010 Leviton Mfg. Co., Inc.
Unpublished, All Rights Reserved
PlantApprovals:
PN-ARN: Pilot Rev:ECO Number:
Artwork Release Date:
Artwork Print Specification Sheet Rev A06.eps
PMCQA
Artist:
Notes:
Other
Cust Other
S & A
Mktg Eng
FOR LEVITON USE ONLY
SPECIFICATIONS :
PROCESS :
MANUAL INTERIORS / BINDERY / FOLD SCHEME :
COMMENTS :
For manuals - designates cover specifications
Dimensions:
Material:
Thickness:
Finish:
:
Spot
CMYK
1:
4:
3:
2:
Color(s): over
1:
4:
3:
2:
Fonts:
Spot
CMYK
1:
4:
3:
2:
Color(s): over
1:
4:
3:
2:
Fonts:
CI0054-3154
H Sanchez
Black Helvetica
1 1
FOLD SCHEME / BINDERY DIAGRAM
Fold Line
Die Cut Punch/Drill Hole
Part No.
DI-000-51120-00E
01 C. Clemente
C. Corona
J. Rhinestine T. Pulsonetti
10/13/10
11" x 8.5"
20 lb.
Offset
Instruction sheet
8.5"
11"
Part No. 8.5"
5.5"
FINAL
V. Lonigro

This manual suits for next models

1

Other Leviton Surge Protector manuals

Leviton 57000-M3S User manual

Leviton

Leviton 57000-M3S User manual

Leviton 51110-PTC User manual

Leviton

Leviton 51110-PTC User manual

Leviton 3880-DIN User manual

Leviton

Leviton 3880-DIN User manual

Leviton 3812 User manual

Leviton

Leviton 3812 User manual

Leviton 52412-DS3 User manual

Leviton

Leviton 52412-DS3 User manual

Leviton 5280 User manual

Leviton

Leviton 5280 User manual

Leviton 51005-WM User manual

Leviton

Leviton 51005-WM User manual

Leviton R Series User manual

Leviton

Leviton R Series User manual

Leviton 3862-CON User manual

Leviton

Leviton 3862-CON User manual

Leviton 37120-7 User manual

Leviton

Leviton 37120-7 User manual

Leviton 5480-IG User manual

Leviton

Leviton 5480-IG User manual

Leviton SmartlockPro GSIA2 User manual

Leviton

Leviton SmartlockPro GSIA2 User manual

Leviton 51015-WM User manual

Leviton

Leviton 51015-WM User manual

Leviton 32120-DY3 User manual

Leviton

Leviton 32120-DY3 User manual

Leviton 37120-7 User manual

Leviton

Leviton 37120-7 User manual

Leviton 57000 Series User manual

Leviton

Leviton 57000 Series User manual

Leviton 3803-MOD User manual

Leviton

Leviton 3803-MOD User manual

Leviton 51020-WMT User manual

Leviton

Leviton 51020-WMT User manual

Leviton 51120-3R User manual

Leviton

Leviton 51120-3R User manual

Leviton 51005-WM User manual

Leviton

Leviton 51005-WM User manual

Leviton 5480 User manual

Leviton

Leviton 5480 User manual

Leviton 55240-ASA User manual

Leviton

Leviton 55240-ASA User manual

Leviton 47120-7 User manual

Leviton

Leviton 47120-7 User manual

Leviton 37120-7 User manual

Leviton

Leviton 37120-7 User manual

Popular Surge Protector manuals by other brands

Asco 400 Series Installation & operation manual

Asco

Asco 400 Series Installation & operation manual

Transtector I2R SPV1000 3-40 installation guide

Transtector

Transtector I2R SPV1000 3-40 installation guide

Atexor Slam Instructions for safe use

Atexor

Atexor Slam Instructions for safe use

Chenzhu GS8567-EX user manual

Chenzhu

Chenzhu GS8567-EX user manual

Eaton SPC Series installation instructions

Eaton

Eaton SPC Series installation instructions

CyberPower 1220RMS Specification sheet

CyberPower

CyberPower 1220RMS Specification sheet

Emerson 500 Series Installation, operation and maintenance manual

Emerson

Emerson 500 Series Installation, operation and maintenance manual

Black Lion Audio PG-P Type C owner's manual

Black Lion Audio

Black Lion Audio PG-P Type C owner's manual

Philips SPP4069A/17 user manual

Philips

Philips SPP4069A/17 user manual

Projoy Electric PESP-1000 instructions

Projoy Electric

Projoy Electric PESP-1000 instructions

CyberPower B615 user manual

CyberPower

CyberPower B615 user manual

Sanus Elements ELM203 instructions

Sanus Elements

Sanus Elements ELM203 instructions

Acoustic Research ARHT10 user guide

Acoustic Research

Acoustic Research ARHT10 user guide

ATOMI Power Pad user manual

ATOMI

ATOMI Power Pad user manual

Chenzhu CZLB-160/440 Series user manual

Chenzhu

Chenzhu CZLB-160/440 Series user manual

ZUUM SP6PH user manual

ZUUM

ZUUM SP6PH user manual

Joslyn JSP series Installation, operation and maintenance guide

Joslyn

Joslyn JSP series Installation, operation and maintenance guide

Shopify EVP-3PH quick guide

Shopify

Shopify EVP-3PH quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.