www.moteck.com
3
WIRE CONNECTION
For ID10 actuator, connection rule of power wires varies according to different types and gear ratio(s).
Please follow the instructions below.
Definition
GND
Red
Black
Wire color
Blue
Comments
Voltage input range: 3.5 ~ 20VVin
White
Hall effect sensor resolution: 20ppi, 1.27mm/pulse (0.787pulses/mm)
High= 10.8V (±0.6V)
Low= GND
Hall signal data:
Signal
wires
Hall outputYellow
● With single Hall effect sensor positioning feedback
● Standard (without Limit switch nor positioning feedback)
Gear ratio: 5:1, 10:1, 20:1
Gear ratio: 30:1, 40:1
Red
Black
Wire color CommentsDefinition
Red
Black
Wire color CommentsDefinition
● With Limit switches
Red
Black
Wire color CommentsDefinition
Connect red wire to “Vdc +” & black wire to “Vdc -“ of DC power to
extend the actuator. Switch the polarity of DC input to retract it.
DC Power
Power
wires
Connect red wire to “Vdc -” & black wire to “Vdc +“ of DC power to
extend the actuator. Switch the polarity of DC input to retract it.
DC Power
Power
wires
Connect red wire to “Vdc +” & black wire to “Vdc -“ of DC power to
extend the actuator. Switch the polarity of DC input to retract it.
DC Power
Power
wires
DC Power
Power
wires
Connect red wire to “Vdc +” & black wire to “Vdc -“ of DC power to
extend the actuator. Switch the polarity of DC input to retract it.
Hall
Low
High