Cam's Screw
Note 1 : To avoid damaging the plastic gears under the
Limit Cam, please hold Upper & Lower Limit CAM
when you tighten or loosen the cam's screw .
LIMIT SWITCH
Caution:
Make sure no rotating of the inner tube while the motor is running.
RESET LIMIT
The most extended position is defined by the “Upper Limit Cam”, and the most retracted position
is defined by the “Lower Limit Cam” as well. Please set the limit positions just follow the rules below,
if necessary.
Step 1. If the actuator has been installed, uninstall it first and then remove the gearbox cover.
Step 2. Connect the power wire to correct DC power and let the actuator starts retracting till the
switch of lower limit is pressed by Cam, then the motor stops immediately. Now you can turn
the inner tube in clockwise or counter-clockwise direction to the demanded position. Then,
the lower limit is set.
Step3. Let the actuator extends to the position you want, and adjust the “Upper Limit Cam” to press
the upper limit switch directly, then the demanded stroke is done after you lock the Cam’s
screw.
BW
YW
B
Y
The resistance range is variable, according to the travel length, and stroke as below:
NOTE
This appliance cannot be used by children or persons with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
POT WIRING
POTENTIOMETER
WIRE CONNECTION FOR SENSORS
Reed Sensor Connection: Hall Sensor Connection:
Upper Limit cam
Lower Limit cam
Red
Black
Upper Limit cam
Lower Limit cam
Red
Black
Motor(-)
Motor(+)
Reed Sensor
Motor(-)
Motor(+)+SignalG
c 2014 Moteck. Printed in Taiwan. The contents of this publication are the copyright of the publisher and may not be copied or
even extracted unless prior written permission is authorized.
1F-1,No.79,Sec.1,Xintai5thRd.,XizhiDist.,
NewTaipeiCity22101,Taiwan(R.O.C.) E-mail:sales@moteck.com.tw
http://www.moteck.com.tw
TEL:+886-2-2698-1220
AX:+886-2-2698-1324
M1-IND-2-I-002-141121A
F
Value of Potentiometer
100 0.3-8.0 K
The Ohm value between blue and white wire
Tolerance: 0.3 K
150
200 0.3-8.5 K
0.3-9.1 K
300
457 0.3-8.6 K
0.3-9.2 K
610
900 0.3-9.8 K
0.3-9.2 K
Stroke(mm)
Resistance
Limit Switch
Cam