With Limit Switch (LT) type
Gear ratio: 5:1 / 10:1 / 20:1 / 30:1 / 40:1
Power wire
Red & White: Extend
Red & Black: Retract
Ground
-When Red & White are connected to AC power,
the actuator will extend; When Red & Black are
connected to AC power, the actuator will retract.
© 2019 Moteck. Printed in Taiwan. The contents of this publication are the copyright of the publisher and may not be copied or even extracted unless prior written
permission is authorized.
SAFETY DECLARATION
This appliance cannot be used by children or persons with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction.
M1-IND-I-0003-2.0
YW
B
W
B
Y
Actuator extends
GND
Data
VCC
POT wire
-White, Yellow & Blue are positioning signal wires.
-The resistance between Blue and White wire
increases when extending, and decreases
when retracting.
153
203
254
457
305
102
610
Stroke (mm)
0.3 ~ 8.7K
0.3 ~ 9.2K
0.3 ~ 7.4K
0.3 ~ 9.4K
0.3 ~ 8.8K
0.3 ~ 8.1K
0.3 ~ 9.9K
Resistance (±0.3KΩ)
The POT value vs. stroke as shown in the table:
POT wire