manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MULTISPAN
  6. •
  7. Temperature Controllers
  8. •
  9. MULTISPAN TC-49 User manual

MULTISPAN TC-49 User manual

Other MULTISPAN Temperature Controllers manuals

MULTISPAN UTC-423 User manual

MULTISPAN

MULTISPAN UTC-423 User manual

MULTISPAN TC-29P User manual

MULTISPAN

MULTISPAN TC-29P User manual

MULTISPAN UTC-421P User manual

MULTISPAN

MULTISPAN UTC-421P User manual

MULTISPAN UTC-1202 User manual

MULTISPAN

MULTISPAN UTC-1202 User manual

MULTISPAN UTC-2202 User manual

MULTISPAN

MULTISPAN UTC-2202 User manual

MULTISPAN UTC-121G User manual

MULTISPAN

MULTISPAN UTC-121G User manual

MULTISPAN UTC-4202G User manual

MULTISPAN

MULTISPAN UTC-4202G User manual

MULTISPAN UTC-4201A User manual

MULTISPAN

MULTISPAN UTC-4201A User manual

MULTISPAN UTC-221P User manual

MULTISPAN

MULTISPAN UTC-221P User manual

MULTISPAN UTC-122 User manual

MULTISPAN

MULTISPAN UTC-122 User manual

MULTISPAN UTC-221G User manual

MULTISPAN

MULTISPAN UTC-221G User manual

MULTISPAN TC-19 User manual

MULTISPAN

MULTISPAN TC-19 User manual

MULTISPAN UTC-121P User manual

MULTISPAN

MULTISPAN UTC-121P User manual

MULTISPAN UTC-1202G User manual

MULTISPAN

MULTISPAN UTC-1202G User manual

MULTISPAN PTC-4202A-M1 User manual

MULTISPAN

MULTISPAN PTC-4202A-M1 User manual

MULTISPAN UTC-222 User manual

MULTISPAN

MULTISPAN UTC-222 User manual

MULTISPAN PTC-1202A User manual

MULTISPAN

MULTISPAN PTC-1202A User manual

MULTISPAN TC-49 User manual

MULTISPAN

MULTISPAN TC-49 User manual

MULTISPAN UTC-320 User manual

MULTISPAN

MULTISPAN UTC-320 User manual

MULTISPAN UTC-121P User manual

MULTISPAN

MULTISPAN UTC-121P User manual

MULTISPAN UTC-4203 User manual

MULTISPAN

MULTISPAN UTC-4203 User manual

MULTISPAN TC-49 User manual

MULTISPAN

MULTISPAN TC-49 User manual

MULTISPAN TC-442 User manual

MULTISPAN

MULTISPAN TC-442 User manual

MULTISPAN UTC-121P User manual

MULTISPAN

MULTISPAN UTC-121P User manual

Popular Temperature Controllers manuals by other brands

Brookfield TC Series Operator's manual

Brookfield

Brookfield TC Series Operator's manual

Nibe HPAC 45 Installer manual

Nibe

Nibe HPAC 45 Installer manual

Auber TD100 instruction manual

Auber

Auber TD100 instruction manual

IntelliSense INTELLITEMP T-1000 installation instructions

IntelliSense

IntelliSense INTELLITEMP T-1000 installation instructions

Swegon LUNAd MB Instructions for use

Swegon

Swegon LUNAd MB Instructions for use

Lucky Reptile Thermo Control II Operation instructions

Lucky Reptile

Lucky Reptile Thermo Control II Operation instructions

SMC Networks Thermo-con INR-244-639 Operation manual

SMC Networks

SMC Networks Thermo-con INR-244-639 Operation manual

SENSORMETRIX Argon 100 manual

SENSORMETRIX

SENSORMETRIX Argon 100 manual

Fuji Electric PXE4 instruction manual

Fuji Electric

Fuji Electric PXE4 instruction manual

Yuyao gongyi XMT-808 series Operation manual

Yuyao gongyi

Yuyao gongyi XMT-808 series Operation manual

eltherm Ex-TC It Series operating instructions

eltherm

eltherm Ex-TC It Series operating instructions

Selec TC544C user guide

Selec

Selec TC544C user guide

P.W. KEY rt-208gt operating manual

P.W. KEY

P.W. KEY rt-208gt operating manual

Omron C200H-TV Series Operation manual

Omron

Omron C200H-TV Series Operation manual

BH Thermal BriskONE owner's manual

BH Thermal

BH Thermal BriskONE owner's manual

West Control Solutions KS 45 Operation Notes

West Control Solutions

West Control Solutions KS 45 Operation Notes

Opt Lasers TEC-8A-24V-PID-HC operating manual

Opt Lasers

Opt Lasers TEC-8A-24V-PID-HC operating manual

Vaillant VR 92/3 Operating and installation instructions

Vaillant

Vaillant VR 92/3 Operating and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

TC-49
www.multispanindia.com
Page - 2
All safety related codifications, symbols and instructions that appear in this operating manual
or on the equipment must be strictly followed to ensure the safety of the operating personnel as
well as the instrument.
If all the equipment is not handled in a manner specified by the manufacturer, it might impair the
protection provided by the equipment .
Product improvement and upgrade is a constant procedure. So for more updated operating information and support,
Please contact our helpline : +91-9978991474/76/82 or Email at [email protected] Ver: 05-2017
=> Read complete instructions prior to installation and operation of the unit.
WARNING : Risk of electric shock.
3) Cable used for connection to power source, must have a cross section of 1mm or greater. These wires
should have insulations capacity made of at least 1.5kV.
2) To reduce electro magnetic interference, use wire with adequate rating and twists of the same of
equal size shall be made with shortest connection.
4) When extending the thermocouple lead wires, always use thermocouple compensation wires for wiring
for the RTD type, use a wiring material with a small lead resistance (5Ω max per line)and no resistance
differentials among three wires should be present.
1) To prevent the risk of electric shock power supply to the equipment must be kept OFF while doing the
wiring arrangement. Do not touch the terminals while power is being supplied.
5) A better anti-noise effect can be expected by using standard power supply cable for
the instrument.
1) This equipment, being built-in-type, normally becomes a part of main control panel and such in case the
terminals do not remain accessible to the end user after installation and internal wiring.
2) Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product
or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.
3) Circuit breaker or mains switch must be installed between power source and supply terminal to
facilitate power ‘ON’ or ‘OFF’ function. However this mains switch or circuit breaker must be
installed at convenient place normally accessible to the operator.
4) Use and store the instrument within the specified ambient temperature and humidity ranges as
mentioned in this manual.
Warning Guidelines
Installation Guidelines
Mechanical Installation
Maintenance
Safety Precautions
1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source,
caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals.
1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.
2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any
other cleaning agent.
3) Fusible resistor must not be replaced by operator.
2
A
B
C
D
EF
MODEL A
50mm 50mm 45mm 45mm 3mm 70mm
BC
D E
F
DIMENSIONS
68mm - 2.68 inches
60mm - 2.36 inches
1 2 3
C
°
TC 49
!
100
270V AC
~
50/60 HZ
4VA
3
4
5
1
2
~
L
N
SSR
+
-
7
6
-
7
6
8
9
10
11
12
+
-
T/C
NC
C
R1
NO
www.multispanindia.com
Page - 1
TC-49
2) If Sensor is not Connected, Display will show “OPN” message.
3) To Show set point, press Key.
Note:
4) Auto out time is 15 sec without saving.
5) Every time the instument is turn on,following pattern will be displayed.
Technical SpecificationTechnical Specification
POWER ON
Display for 3 sec
display for 2 sec, according to the input
sensor programmed.
display for 2 sec, according to the control
action programmed.
Process Value
8 88
t c J
T P
3 0
3 Digit 7 seg 0.56”,White LED Display
J type: 0 to 600°C
K type: 0 to 999°C
TP/ ON-OFF (selectable)
Output
Power Supply
Operating
Temperature
Relative
Humidity
100 to 270V AC,50/60 Hz, Approx 4VA
0°C To 55°C
Up to 95% RH Non Condensing
Model
Display
Size (mm)
Panel Cutout
Input
Temperature
Range
Control Action
48 (H) X 48 (W) X 70 (D) mm
45 X 45 mm
TC-49
J TYPE , K TYPE (selectable)
1Relay, 1C/O Contact,10A, 230V AC
S.S.R, 12V DC approx, 10mA DC.
SETSET
Connection Diagram
OPERATING MANUAL
TEMPERATURE CONTROLLER
TC-49
1 2 3
Protection
Level
(As per request)
IP-65 (Front side) As per IS/IEC 60529 : 2001
1) If Sensor Connection is reverse, Display will show “SRE” message.
°C
TC 49
MadeinIndia
www.multispanindia.com
www.multispanindia.com
Page - 4
P A s Password Message
IF TP SELECTED IF ON-OFF SELECTED
p B
0 0 4
C T
0 1 2
M R
0 0 0
Proportional
Band
Cycle Time
Manual Reset
3 7
TO ENTER CONTROL
PARAMETER
SETTING, ENTER “37”
SET
SET
SET
Press key
to Save & Exit
Press key
to Save & Exit
Press key
to Save & Exit
ON-OFF TP
P A S
0 7 3
I N P
J
C T R
Password Message
Input ( J,K)
T P
O N F
TO ENTER BASIC
CONFIGURATION
SETTING, ENTER “73”
Control Action
www.multispanindia.com
Page - 3
1) Press + Or Key to set the set point.
2) Press Key to go next parameter.
3) Release the Key, to save the set point.
SET
SET
SET
SET
Press Key to go next parameter.
SETSET
SET
Hysteresis
H Y S
0 0 3
TC-49 TC-49
Basic Configuration Control Parameter
Key Operation
Off-set correction -10°C to 10°C
CT 4 To 30
Hysteresis 1°C to 10°C
MR -10°C to 10°C
PB
Sr.
1
2
3
4
5
1 To 15
Parameter Range for J, K
h
SET
Press key
to Save & Exit
O F S
O 0 0
OFF-SET
(Range: -10°C to 10°C)
0 0 0
* Ask to company person
P A 5
Password Message
OffSet Point Setting
SET
Press key For 4 Sec
2 0 0
On releasing SET key will store
the latest set value & display
shows process value.
5 0 Process Value
Press Key
SETSET
Set Point Setting
Press + Or Key to set the set point.
SETSET