manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MULTISPAN
  6. •
  7. Temperature Controllers
  8. •
  9. MULTISPAN UTC-122 User manual

MULTISPAN UTC-122 User manual

All digit segment will be turned ON for 3 sec
Previous or default sensor input will be displayed for 2 sec
Process Value
Set Value
POWER ON







ENT
SET
UTC 122
TUNE
ºC
PV
SV
 

17 8 9
12
1314
10
11
1617181920 15
23456
NC NC
C C
NO NO
TC
+
-
+
-
RELAY-1 RELAY-2
100
250V AC
~
50/60 Hz
4VA
!
LN
O/P
S.S.R RTD
www.multispanindia.com
Page - 1
UTC-122,222
Note:
1) If Sensor Connection is reversed, Display will show “” message.
2) If Sensor is not connected, Display will show  message.
3) Every time the instrument is turned ON, Following pattern will be displayed
J: 0 to 600°C / K: 0 to 1200°C /
PT-100: -99 to 400ºC /PT.1: -99.0 to 400.0°C
PID/ ON-OFF (selectable)
Output
Power Supply
Protection Level
Operating Relative
(As per request)
Temperature Humidity
1st Output for Heating : 1Relay 1C/O,230V AC ,5A Or SSR,12V DC Approx,30mA
2nd Output for Cooling : 1Relay 1C/O,230V AC ,5A
100 to 250V AC, 50 / 60 Hz, Approx 4VA
IP-65(Front side) AS per IS/IEC 60529:2001
0°C To 55°C Up to 95% RH Non Condensing
Model
Display
Size(HXWXD)
Panel Cutout
Input
Temperature
Range
Control Action
UTC 122
96 X 96 X 50 mm
92 X 92 mm 68 X 68 mm
72 X 72 X 85 mm
UPPER:- 4 Digit 7 seg 0.70”,red LED Display
LOWER:- 4 Digit 7 seg 0.50”,green LED Display
UTC 222
J, K, PT-100 (selectable)
Technical Specification
Connection Diagram
OPERATING MANUAL
PID TEMPERATURE CONTROLLER
UTC-121P,221P & 421P
Technical Specification
Connection Diagram
OPERATING MANUAL
UNIVERSAL TEMPERATURE CONTROLLER
UTC-122, 222
TC
+
RTD
-
!
L
N
1
2
3
4
5
6
7
-
+
O/P
S.S.R
RELAY-1
RELAY-2
100
250V AC
~
50/60 Hz
4VA
NC
NO
NO
NC
C
C
8
9
10
11
12
13
14
SET
ENT
UTC 222
R1
R2
TUNE
PV
SV
ºC
 

www.multispanindia.com
Page - 2
Set Value
Set Point 1
Set Point 2
Password Message
Press key for 3 sec to enter
Password
SET
Process Value
Input ( J / K / Pt.1 / Pt100 )
Password Message
. 
K
SET
Press key
ENT
TO ENTER BASIC
CONFIGURATION
SETTING, ENTER “73”
Press key
SET
1) Press key to go parameter setting.
3) Press key to save change in setting
4) Press key for 6 sec to start/stop PID AUTO TUNING
5) Press + key for 3 sec to go to factory setting mode.
SET
ENT
2) Press or key to change value or to select option.
Basic Configuration
Set Point Setting
Key Operation
UTC-122,222












Press key to Save & Exit
ENT
Control Action (PID/ON-OFF)
Relay2 Mode (TP/ON-OFF)
Set2 Mode (Relative/Individual)









Set Point Low Limit
Set Point High Limit




OFF-SET


PID AUTO-TUNING
Press key for 6 sec to start/stop
PID auto-tuning
SET SET
www.multispanindia.com
Page - 3
Password Message
IF PID SELECTED IF ON-OFF SELECTED
SET
TO ENTER CONTROL
PARAMETER
SETTING, ENTER “37”
Control Parameter
Factory Setting
FACTORY SETTING
PARAMETER
IT
CT
OFFSET
PB
DT
MR
HYSTERESIS
VALUES
0300
15 sec
020.0
0075
0°C
0°C
3°C
SR.
2
4
6
1
3
5
7
ENT
ENT
yes : press key to apply factory set
values as shown in table.
nO : press key to escape
from factory setting.

Press + key
for 3 sec
UTC-122,222
PV
SV



 
 







.












Press key to save & exit
ENT
Press key
SET
Manual Reset
Proportional
Band
Integral
Time
Derivative
Time
Cycle Time
PID
Parameters
ON-OFF
Parameters
Hysteresis 1
Cool HYS
Offset -20.0°C to +20.0°C
-20°C to +20°C
CT 4 sec to 99 sec 4 sec to 99 sec
IT
0000 to 9999
0000 to 9999
Hysteresis 0.1°C to 50.0°C
1°C to 50°C
MR -9.0 to +9.0
-9 to +9
DT 0000 to 9999 0000 to 9999
PB
Sr.
1
2
3
4
5
6
7
0000 to 999.9 0000 to 999.9
Parameter Range for PT.1 sensor
Range for J, K, PT100
www.multispanindia.comPage - 4
All safety related codifications, symbols and instructions that appear in this operating manual
or on the equipment must be strictly followed to ensure the safety of the operating personnel as
well as the instrument.
If all the equipment is not handled in a manner specified by the manufacturer, it might impair the
protection provided by the equipment .
Product improvement and upgrade is a constant procedure. So for more updated operating information and support,
Please contact our helpline : +91-9978991474/76/82 or Email at mark[email protected] Ver: 05-2017
=> Read complete instructions prior to installation and operation of the unit.
WARNING : Risk of electric shock.
3) Cable used for connection to power source, must have a cross section of 1mm or greater. These wires
should have insulations capacity made of at least 1.5kV.
2) To reduce electro magnetic interference, use wire with adequate rating and twists of the same of equal size shall
be made with shortest connection.
4) When extending the thermocouple lead wires, always use thermocouple compensation wires for wiring for the RTD
type, use a wiring material with a small lead resistance (5Ω max per line)and no resistance differentials among
three wires should be present.
1) To prevent the risk of electric shock power supply to the equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is being supplied.
5) A better anti-noise effect can be expected by using standard power supply cable for the instrument.
1) This equipment, being built-in-type, normally becomes a part of main control panel and such in case the
terminals do not remain accessible to the end user after installation and internal wiring.
2) Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product
or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.
3) Circuit breaker or mains switch must be installed between power source and supply terminal to
facilitate power ‘ON’ or ‘OFF’ function. However this mains switch or circuit breaker must be
installed at convenient place normally accessible to the operator.
4) Use and store the instrument within the specified ambient temperature and humidity ranges as
mentioned in this manual.
Warning Guidelines
Safety Precautions
Installation Guidelines
Mechanical Installation
Maintenance
1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source,
caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals.
1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.
2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any other cleaning agent.
3) Fusible resistor must not be replaced by operator.
2
UTC-122,222
95mm - 3.75 inches
85mm - 3.34 inches
136mm - 5.35 inches
120mm - 4.72 inches
B
A
F
E
MODEL A
96mm 96mm 92mm 92mm 3mm 50mm
BC
D E
F
DIMENSIONS
MODEL A
72mm 72mm 68mm 68mm 3mm 85mm
BC
D E
F
DIMENSIONS
C
C
D
D
E
F
B
A
ENT
SET
UTC 122
TUNE
ºC
PV
SV



SET
ENT
UTC 222
R1
R2
TUNE
PV
SV
ºC
 


This manual suits for next models

2

Other MULTISPAN Temperature Controllers manuals

MULTISPAN UTC-113P User manual

MULTISPAN

MULTISPAN UTC-113P User manual

MULTISPAN UTC-1202G User manual

MULTISPAN

MULTISPAN UTC-1202G User manual

MULTISPAN UTC-222 User manual

MULTISPAN

MULTISPAN UTC-222 User manual

MULTISPAN TC-221P User manual

MULTISPAN

MULTISPAN TC-221P User manual

MULTISPAN UTC-421P User manual

MULTISPAN

MULTISPAN UTC-421P User manual

MULTISPAN UTC - 413P User manual

MULTISPAN

MULTISPAN UTC - 413P User manual

MULTISPAN UTC-2202 User manual

MULTISPAN

MULTISPAN UTC-2202 User manual

MULTISPAN UTC-2200G User manual

MULTISPAN

MULTISPAN UTC-2200G User manual

MULTISPAN PTC-4202A-M1 User manual

MULTISPAN

MULTISPAN PTC-4202A-M1 User manual

MULTISPAN UTC-121P User manual

MULTISPAN

MULTISPAN UTC-121P User manual

MULTISPAN TC-49P User manual

MULTISPAN

MULTISPAN TC-49P User manual

MULTISPAN TC-442 User manual

MULTISPAN

MULTISPAN TC-442 User manual

MULTISPAN UTC-114 User manual

MULTISPAN

MULTISPAN UTC-114 User manual

MULTISPAN UTC-221P User manual

MULTISPAN

MULTISPAN UTC-221P User manual

MULTISPAN UTC-2202G Instruction sheet

MULTISPAN

MULTISPAN UTC-2202G Instruction sheet

MULTISPAN UTC-214 User manual

MULTISPAN

MULTISPAN UTC-214 User manual

MULTISPAN PTC-1202A User manual

MULTISPAN

MULTISPAN PTC-1202A User manual

MULTISPAN UTC-121P User manual

MULTISPAN

MULTISPAN UTC-121P User manual

MULTISPAN UTC-1202 User manual

MULTISPAN

MULTISPAN UTC-1202 User manual

MULTISPAN TC-19 User manual

MULTISPAN

MULTISPAN TC-19 User manual

MULTISPAN UTC-4201A User manual

MULTISPAN

MULTISPAN UTC-4201A User manual

MULTISPAN MTC-1202 User manual

MULTISPAN

MULTISPAN MTC-1202 User manual

MULTISPAN TC-49 User manual

MULTISPAN

MULTISPAN TC-49 User manual

MULTISPAN TC-443 User manual

MULTISPAN

MULTISPAN TC-443 User manual

Popular Temperature Controllers manuals by other brands

DOTECH FX3DH user manual

DOTECH

DOTECH FX3DH user manual

Lochinvar INS7141 installation instructions

Lochinvar

Lochinvar INS7141 installation instructions

Brink Air Control user manual

Brink

Brink Air Control user manual

Honeywell HCW 82 Installation and operation

Honeywell

Honeywell HCW 82 Installation and operation

ACS TCO manual

ACS

ACS TCO manual

TechGrow Clima Control Plus manual

TechGrow

TechGrow Clima Control Plus manual

Omron E5ZE-8 Communications manual

Omron

Omron E5ZE-8 Communications manual

NexSens TS210 user manual

NexSens

NexSens TS210 user manual

Danfoss ECL Comfort 210 installation guide

Danfoss

Danfoss ECL Comfort 210 installation guide

Danfoss 3060 Installation & user's instructions

Danfoss

Danfoss 3060 Installation & user's instructions

Bosch FR 120 Operating instructions for the user

Bosch

Bosch FR 120 Operating instructions for the user

Xetal YugenFace manual

Xetal

Xetal YugenFace manual

Warner Instruments FireRight LT instruction sheet

Warner Instruments

Warner Instruments FireRight LT instruction sheet

TE Technology TC-24-25 Operation manual

TE Technology

TE Technology TC-24-25 Operation manual

Polyaire Zonemaster Technical manual

Polyaire

Polyaire Zonemaster Technical manual

Tech Controllers EU-292n v3 user manual

Tech Controllers

Tech Controllers EU-292n v3 user manual

Hugo Müller TS 3.10 KNX Series instruction manual

Hugo Müller

Hugo Müller TS 3.10 KNX Series instruction manual

Mastip iB6 user guide

Mastip

Mastip iB6 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.