Page 1
TC - 49P
Input Types
Resolution
Indication
Accuracy
Input Range
TEMPERATURE CONTROLLER
0 to 600°C J
1°C
±1% of FSD ± 1°C
POWER SUPPLY:
ENVIRONMENT CONDITION:
Display
Heating
Size (mm)
Keys
Panel Cutout
Power
Consuption
(VA Rating)
Relative Humidity
Protection Level
(As per request)
Relay
Output Signal
Supply
Voltage
Operating Temp.
Relay Type
Rating
3 digit, 7 segment, 0.8” RED
1) PID control with Auto Tuning
2) ON-OFF control
48 (H) x 48 (W) x 70 (D) mm
100 to 270V AC, 50-60Hz
0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
1 Nos
12V DC, 30mA DC
(On-Off condition)
1C/O (NO-C-NC)
10A, 230V AC / 28V DC
SET, INC, DEC
45 (H) x 45 (W) mm
4VA @ 230V AC MAX
Relay Output
SSR Drive Output
TECHNICAL SPECIFICATION
MECHANICAL INSTALLATION
TERMINAL CONNECTION
(FSD:- Full Scale Deflection)
OUTPUT SPECIFICATION:
INPUT SPECIFICATION:
DISPLAY AND KEYS:
DIMENSION:
CONTROL METHOD:
6
7
Thermocouple
+
Sensor Input
0 to 999°C K
SSR
+
-
48
70
45
45
3
48
Outline Dimension (mm) Panel Cutout
Dimension (mm)
TC 49P
SET
°
OUT
1
2
3
4
5
NC
C
R1
NO
www.multispanindia.com
6
7
8
9
10
+
-
T/C
!
100
270V AC
~
50/60 HZ
4VA
L
N
MadeinIndia
Page 2
°
Read complete instructions prior to installation
and operation of the unit.
WARNING : Risk of electric shock.
SAFETY PRECAUTION
!
All safety related codifications, symbols and instructions that
appear in this operating manual or on the equipment must be
strictly followed to ensure the safety of the operating personnel
as well as the instrument.
If all the equipment is not handled in a manner specified by
the manufacturer, it might impair the protection provided by the
equipment.
KEY OPERATION
To View Setpoint Press
& Hold
To Change Setpoint +
To Enter in Parameter Setting
mode
To Go into Factory Setting mode
PRESS KEYFUNCTION
OPERATOR MODE
PARAMETER SETTING MODE
To set parameter value and move
to next parameter
To increment parameter value.
To decrement parameter value.
To save & exit From parameter
setting mode
WARNING GUIDELINES
WARNING : Risk of electric shock.
1. To prevent the risk of electric shock, power supply to the
equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is
being supplied.
2. To reduce electro magnetic interference, use wire with
adequate rating and twists of the same of equal size shall
be made with shortest connection.
3. Cable used for connection to power source, must have a
cross section of 1mm or greater. These wires should have
insulations capacity made of at least 1.5kV.
4. When extending the thermocouple lead wires, always use
thermocouple compensation wires for wiring for the RTD
type, use a wiring material with a small lead resistance
(5 max per line) and no resistance differentials among
three wires should be present.
5. A better anti-noise effect can be expected by using
standard power supply cable for the instrument.
Ω
INSTALLATION GUIDELINES
1. This equipment, being built-in-type, normally becomes a
part of main control panel and in such case the terminals
do not remain accessible to the end user after installation
and internal wiring.
2. Do not allow pieces of metal, wire clippings, or fine metallic
fillings from installation to enter the product or else it may
lead to a safety hazard that may in turn endanger life or
cause electrical shock to the operator.
3. Circuit breaker or mains switch must be installed between
power source and supply terminal to facilitate power ‘ON’
or ‘OFF’ function. However this mains switch or circuit
breaker must be installed at convenient place normally
accessible to the operator.
4. Use and store the instrument within the specified ambient
temperature and humidity ranges as mentioned in this
manual.
MECHANICAL INSTALLATION GUIDELINES
1. Prepare the panel cutout with proper dimensions as shown
above.
2. Fit the unit into the panel with the help of clamp given.
3. The equipment in its installed state must not come in close
proximity to any heating source, caustic vapors, oil steam,
or other unwanted process byproducts.
4. Use the specified size of crimp terminal (M3.5 screws) to
wire the terminal block. Tightening the screws on the
terminal block using the tightening torque of the range of
1.2 N.m.
5. Do not connect anything to unused terminals.
MAINTENANCE
1. The equipment should be cleaned regularly to avoid blockage
of ventilating parts.
2. Clean the equipment with a clean soft cloth. Do not use
isopropyl alcohol or any other cleaning agent.
3. Fusible resistor must not be replaced by operator.
1 - Control output indication
2 - Auto tuning on indication
STATUS LED DESCRIPTION
Press 3 sec
Press
3 sec
+
/
Press
5 sec
1
For start/stop PID auto tuning Press
6 sec
2
TC 49P
SET
OUT
t.
un
Page 3
PARAMETER SETTING
ERROR
OPN
SRE
MEANING
When an error has occurred the display indicates error codes
as given below.
Sensor is not connected or
Over range condition or
sensor break
Sensor connection is reversed
ERROR DISPLAY
FACTORY SETTING
PARAMETER RANGE
Press + key
for 3 sec
CORRECTIVE ACTION:
Check the sensor and the input wiring. If problem still exists,
replace the sensor. And still if problem is not solved yet by the
user, then please contact company person
yes
: Press key to apply factory set
values as shown in table.
: Press key to exit
from factory setting.
SET
SET
100
125
pas
SET
Set Point Setting
Process Value
Press key for 5 sec
Set Value
Password Message
Basic Configuration
FACTORY SETTING
PARAMETER
IT
Hysteresis
Offset
VALUES
0°C
125
3°C
20.0°C
30
15 Sec
0°C
SR.
2
4
1
3
5
6
7
no
SET
SET
Press key to view
setpoint
To change value
SET
Press key
100
FST
YES NO
PB
DT
CT
MR
PARAMETER RANGE
-20 to +20°C
0 to 999
1 to 100°C
0 to 999
-9 to +9°C
0.0 to 999°C
SR.
2
4
1
5
6
7
3
IT
Hysteresis
Offset
PB
DT
CT
MR
Input
(J Type / K Type)
Output type
Control Action
/ rLy / ssr
/ (On-OFF/PID )
SET
SET
Press key
Message
Password
Press key for
3 sec to save & exit
73
INP
TCJ / TC
CTR
ONF pID
OUT
BTH
SET
SET
SET
SET
SET
SET
SET
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Enter Password 73
pas
Hysteresis If PID Selected
Offset
(1 to 100°C)
(-20 to +20°C )
OFS
0
HYS
3
SET
SET
SET
Press key
Press key
Press key
SET
Press key
( Both/Relay/SSR )
+/
For Both/Relay = 4 to 99 Sec
For SSR = 1 to 99 Sec
Page 4
Specifications are subject to change, since development is a continuous process,
So for more updated operating information and Support,
Please contact our Helpline: 9978991476/9978991482/9978991474 or
Email at Ver:200206[email protected]
PARAMETER SETTING CONTROL FUNCTION
RLY-OFF
RLY-ON
RLY-ON
RLY-ON
RLY-OFF
RLY-OFF
Temp.
S.V
HYST
Time
OFF OFF
ON - OFF control (Heating)
ON ON
SET
Press key for
3 sec to save & exit
PB
20.0
DT
IT
CT
125
15
30
0
Integral Time
Proportional band
( 0.0 to 999°C )
( 0 to 999 )
( 0 to 999 )
Derivative Time
( 4 to 99 Sec )
( -9 to +9°C )
SET
SET
SET
SET
SET
SET
SET
SET
SET
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Control Parameter
IF PID Control Action Selected
Message
Password
37
Password is 37
pas
Press key
SET
Press key
SET
SET
Press key
Cycle Time
Manual Reset
MR
Auto Tuning:-
The Auto-tuning function automatically computes
and sets the Proportional band (Pb) , Integral time (It),
Derivative time (dt), and cycle time as per process
characteristics.
Tuning LED will turn “ON” during Auto-Tuning
If the power goes off before auto-tuning is completed,
auto-tuning will be restarted at next power ON.
PID AUTO-TUNING
Press key for 6 sec to start/stop
PID auto-tuning
Tun

Other MULTISPAN Temperature Controllers manuals

MULTISPAN UTC-1202 User manual

MULTISPAN

MULTISPAN UTC-1202 User manual

MULTISPAN UTC-321P User manual

MULTISPAN

MULTISPAN UTC-321P User manual

MULTISPAN UTC-222 User manual

MULTISPAN

MULTISPAN UTC-222 User manual

MULTISPAN UTC-221G User manual

MULTISPAN

MULTISPAN UTC-221G User manual

MULTISPAN UTC-121G User manual

MULTISPAN

MULTISPAN UTC-121G User manual

MULTISPAN UTC-2202 User manual

MULTISPAN

MULTISPAN UTC-2202 User manual

MULTISPAN UTC-4203 User manual

MULTISPAN

MULTISPAN UTC-4203 User manual

MULTISPAN MTC-1202 User manual

MULTISPAN

MULTISPAN MTC-1202 User manual

MULTISPAN UTC-121P User manual

MULTISPAN

MULTISPAN UTC-121P User manual

MULTISPAN TC-49 User manual

MULTISPAN

MULTISPAN TC-49 User manual

MULTISPAN UTC-113P User manual

MULTISPAN

MULTISPAN UTC-113P User manual

MULTISPAN TC-49 User manual

MULTISPAN

MULTISPAN TC-49 User manual

MULTISPAN TC-29P User manual

MULTISPAN

MULTISPAN TC-29P User manual

MULTISPAN UTC-121P User manual

MULTISPAN

MULTISPAN UTC-121P User manual

MULTISPAN UTC-221P User manual

MULTISPAN

MULTISPAN UTC-221P User manual

MULTISPAN UTC - 413P User manual

MULTISPAN

MULTISPAN UTC - 413P User manual

MULTISPAN TC-49 User manual

MULTISPAN

MULTISPAN TC-49 User manual

MULTISPAN UTC-421G User manual

MULTISPAN

MULTISPAN UTC-421G User manual

MULTISPAN TC-221P User manual

MULTISPAN

MULTISPAN TC-221P User manual

MULTISPAN UTC-121P User manual

MULTISPAN

MULTISPAN UTC-121P User manual

MULTISPAN UTC-122 User manual

MULTISPAN

MULTISPAN UTC-122 User manual

MULTISPAN UTC-214 User manual

MULTISPAN

MULTISPAN UTC-214 User manual

MULTISPAN UTC-4202G User manual

MULTISPAN

MULTISPAN UTC-4202G User manual

MULTISPAN TC-442 User manual

MULTISPAN

MULTISPAN TC-442 User manual

Popular Temperature Controllers manuals by other brands

Vaillant VRC 470 Installation insrtuctions

Vaillant

Vaillant VRC 470 Installation insrtuctions

Milesight TS101 quick start guide

Milesight

Milesight TS101 quick start guide

S+S Regeltechnik HYGRASGARD FSFTM-Modbus Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik HYGRASGARD FSFTM-Modbus Operating Instructions, Mounting & Installation

Bosch CRC200 Installation instructions for contractors

Bosch

Bosch CRC200 Installation instructions for contractors

Nibe ECS 40 Installer manual

Nibe

Nibe ECS 40 Installer manual

Sure Electronics Remote Temperature Controller user guide

Sure Electronics

Sure Electronics Remote Temperature Controller user guide

Nibe ECS 40 Installer manual

Nibe

Nibe ECS 40 Installer manual

AKO 14212 instructions

AKO

AKO 14212 instructions

Talkpool OY1110 user manual

Talkpool

Talkpool OY1110 user manual

Viessmann OpenTherm operating instructions

Viessmann

Viessmann OpenTherm operating instructions

SmartSense Temp/Humidity Booklet

SmartSense

SmartSense Temp/Humidity Booklet

ESBE CRA112 quick start guide

ESBE

ESBE CRA112 quick start guide

LK Armatur SmartComfort LK 120 instruction manual

LK Armatur

LK Armatur SmartComfort LK 120 instruction manual

Omega Engineering CNiTH-i32 quick start guide

Omega Engineering

Omega Engineering CNiTH-i32 quick start guide

Johnson Controls TE-6800 Series installation guide

Johnson Controls

Johnson Controls TE-6800 Series installation guide

Shinko FCR-13A-R/M instruction manual

Shinko

Shinko FCR-13A-R/M instruction manual

KT-Elektronik SOL3-5 Quick installation and operating manual

KT-Elektronik

KT-Elektronik SOL3-5 Quick installation and operating manual

Licht MFC-300/T-Dry Technical manual

Licht

Licht MFC-300/T-Dry Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.