Quick Installation Guide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
Q I G
ORing's Transporter series managed PoE Ethernet switches are designed
TM
for industrial applications, such as rolling stock, vehicle, and railway
applications. is managed Redundant RingTGPS-9164GT-M12X-BP2-MV
E t h e r n e t s w i t c h w i t h 1 6 x 1 0 / 1 0 0 / 1 0 0 0 B a s e - T ( X ) P. S . E . a n d
4x10/100/1000Base-T(X) ports which is specifically designed for the
toughest and fully compliant with EN50155 requirement. The switch support
Ethernet Redundancy protocol, O-Ring (recovery time < 30ms over 250
units of connection), O-Chain, MRP and MSTP/RSTP/STP (IEEE*NOTE
802.1s/w/D) can protect your mission-critical applications from network
interruptions or temporary malfunctions with its fast recovery technology.
TGPS-9164GT-M12X-BP2-MV also support Power over Ethernet, a system
to transmit electrical power up to 30 watts, along with data, to remote
devices over standard twisted-pair cable in an Ethernet network. Each
TGPS-9164GT-M12X-BP2- MV switch has 16x10/100/100 0Base-T(X)
P.S.E. (Power Sourcing Equipment) ports. P.S.E. is a device (switch or hub
for instance) that will provide power in a PoE connection. TGPS-9164GT-
M12X-BP2-MV includes 2 sets of bypass ports that protect the network from
failures and Network maintenance by ensuring network integrity during
power loss. And support wide operating temperature from -40 C to 75 C.
o o
TGPS-9164GT-M12X-BP2-MV can also be managed centralized and
convenient by Open-Vision, Except the Web-based interface, Telnet and
console (CLI) configuration. Therefore, the switch is one of the most
reliable choices for EN50155 highly-managed Ethernet application.
Package Contents
Installation
Wall-mount
The device can be fixed to the wall. Follow the steps below to install the device on the wall.
Step 1: Hold the evice upright against the walld
Step 2: Insert four screws through the large opening of the keyhole-shaped apertures at the
top and bottom of the unit and fasten the screws to the wall with a screwdriver.
Step 3: Slide the evice downwards and tighten the four screws for added stability.d
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative
for assistance.
Preparation
Before you begin installing the device, make sure you have all of the
package contents available and a PC with Microsoft Internet Explorer 6.0 or
later, for using web-based system management tools.
Elevated Operating Ambient: If installed in a closed environment, make sure
the operating ambient temperature is compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow: Make sure the amount of air flow required for safe
operation of the equipment is not compromised during installation.
Mechanical Loading: Make sure the mounting of the equipment is not in a
hazardous condition due to uneven mechanical loading.
Safety & Warnings
For pin assignments of power, console and relay output ports, please refer to the following tables.
Contents
TGPS-9164GT-M12X-BP2-MV
Pictures Number
1
CD 1
Dimension
Panel Layouts
Front View
1. Reset button
2. Power status LED
3. R.M. status LED
4. Ring status LED
5. Fault LED
6. Power connector
7. Non-PoE Gigabit Ethernet ports with bypass
8. PoE-enabled Gigabit Ethernet ports
9. Link/ACT LED for non-PoE Gigabit ports
10. Speed LED for non-PoE Gigabit ports
11. Link/ACT LED for PoE-enabled Gigabit
ports
12. PoE indicator for PoE-enabled Gigabit
ports
13. Speed LED for PoE-enabled Gigabit ports
14. Console port
15. Relay output port
Wiring
Grounding
Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the grounding pin on the power connector to the grounding
surface prior to connecting devices.
Power port pinouts
The device supports one set of power supply and uses the M12 S-coded
4-pin male connector on the front panel for power input.
Step 1: Insert a power cable to the power connector on the device.
Step 2: Rotate the outer ring of the cable connector until a snug fit is
achieved. Make sure the connection is tight.
Relay output port pinouts
Relay N.C.
3A@24VDC
Network Connection
The switch has sixteen 10/100/1000Base-T(X) PoE and four 10/100/1000Base-T(X) non-PoE
Ethernet ports in the form of M12 connector. Depending on the link type, the switch uses CAT 3, 4,
5,5e UTP cables to connect to network devices (PCs, servers, switches, routers, or hubs). Please
refer to the following table for cable specifications.
TGPS-9164GT-M12X-BP2-MV
TGPS-9164GT-M12X-BP2-MV1907-200-K9164X2MV1-FX010
S w i tc h
E N 5 0 1 5 5
EN50155 20-port managed
Gigabit PoE Ethernet switch
I N D U S T R I A L
Instead of screwing the screws in all the way, it is advised
to leave a space of about 2mm to allow room for sliding the
switch between the wall and the screws.
The switch uses the M12 A-coded 5-pin female connector
on the front panel for relay output. Use a cable with an M12
A-coded 5-pin male connector to connect the relay. The
relay contacts will detect user-configured events and form
an close circuit when an event is triggered.
Cable
Type
Max. Length
Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft)
8-pin female M12
X-coding connector
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft)
8-pin female M12
X-coding connector
1000BASE-T Cat. 5/Cat. 5e 100-ohm UTP UTP 100 m (328 ft)
8-pin female M12
X-coding connector
QIG 1
Console port pinouts
RSVD
RXD
RS-23 2, 115200bps, 8, N , 1
GND
TXD
N.C.
N.C.
V-
V+
Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Ø4. 0
Ø5. 0
Ø8. 0
89. 6
Unit =mm (Tolerance ±0.5mm)
LNK/ACT
Speed
LNK/ACT
Speed
LNK/ACT
Speed
LNK/ACT
Speed
PoE
PoE
PoE
PoE
G5~G 20
LNK/AC T
Speed
LNK/AC T
Speed
LNK/AC T
Speed
LNK/ACT
Speed
PoE
PoE
PoE
PoE
G17
G18
G19
G20
G13
G14
G15
G16
LNK/ ACT
Spee d
LNK/ ACT
Spee d
LNK/ ACT
Spee d
LNK/ ACT
Spee d
PoE
PoE
PoE
PoE
G5~ G20
LNK/ ACT
Spee d
LNK/ ACT
Spee d
LNK/ ACT
Spee d
LNK/ ACT
Spee d
PoE
PoE
PoE
PoE
G17
G18
G19
G20
G13
G14
G15
G16
1
15
14
6
13
11
12
3 4 52
710
9
8
*Note: This function is available by request only.
14. 0
Q I G Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Version 1.0
Q I G
Specifications
S w i tc h
E N 5 0 1 5 5
I N D U S T R I A L
1. Launch the Internet Explorer and type in IP address of the device. The default static
IP address is 192.168.10.1
Follow the steps below to log in and access the system:
2. Log in with default user name and password (both are ).admin
3. After logging in, you should see the following screen. For more information on
configurations, please refer to the user manual. For information on operating the
device using ORing’s Open-Vision management utility, please go to ORing website.
Resetting
To restore the device configurations back to the factory defaults, press the button for aReset
few seconds. Once the power indicator starts to flash, release the button. The device will then
reboot and return to factory defaults.
Configurations
After installing the and connecting cables, he green power LEDswitch t
should turn on. Please refer to the following tablet for LED indication.
Power
Redu nd ant Input Power
Physical Chara cteristic
Enclosure IP-30
Dimension (W x D x H) 26 0(W) x 89.6(D) x 216(H) mm (10.24 x 3.53 x 8.50 in ch.)
Weight (g)
Environmenta l
-40 to 85 C (-40 to 185 F)
o o
Storage Temperature
5% t o 95 % Non-condensing
Operating Humidity
Regulatory App rovals
CE EMC (EN 55024, EN 55032), FCC Part 15B, EN 50155(EN 50121-1, EN 50121-3-2)
EMC
EN 55024 (IEC/EN 61000-4-2 (ESD), IEC/EN 61000-4-3 (RS),IEC/EN 61000-4-4 (EFT),
IEC/EN 61000-4-5 (Surge), IEC/EN 61000-4-6 (CS), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))
EMS
IEC60068-2-27
Shock
IEC60068-2-31
IEC60068-2-6
Vibration
Free Fall
MTBF
EN60950-1
Safety
Fault Contact
Relay Relay output to carry capacity of 3A at 24VDC on M12 connector (5-pin female A- co di ng connector)
Overload Current Protec ti on
Revers e Polarity P ro tection Present
-40 to 75 C (-40 to 167 F)
o o
Operating Tempe rature
ORing Switch Model
10/100/1000 Base-T(X ) Ports
in M12 Auto MDI/MDIX with
P. S. E.
16 (8-pin fem ale X-coding connect or)
Physical Ports
Technology
Ethernet Standard s
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base -TX
IEEE 802.3ab for 1000 Ba se -T
IEEE 802.3x for Flow co nt rol
IEEE 802.3ad for LACP ( Li nk A ggregation Contro l Pr otocol)
IEEE 802.1p for COS (Cl as s of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spa nn ing Tree Pr ot ocol)
IEEE 802.1s for MSTP (M ul tiple Spanning Tree Protocol)
IEEE 802.1x for Authent ic ation
IEEE 802.1AB for LLDP (Li nk L ay er D iscovery Protocol)
IEEE 802.3af PoE specificatio n
IEEE 802.3at PoE specificatio n
8K
MAC Table
8
Priority Queues
10/100/1000Base -T( X) p orts
in M12
Store-and-Forward
Processing
Sw itch Properties
Sw itching latency: <4.9 u s
Sw itching bandwidth: 40 G bp s
Max. Number of Ava ilable VLANs: 4095
IGMP multicast grou ps : 128 for each VLAN
Port rate limi ti ng: User Define
Security Features
Device Binding securi ty f eature
Enable/disable po rt s, MAC based port securit y
Port b as ed network access contr ol ( 802.1x)
VLAN (802.1Q) to segr eg ate and secure network traffi c
Radi us c entralized password manag em ent
SNMPv3 encrypted au th entication and access s ec urity
Https / SSH enhance network s ec urity
Software Fea tures
STP/RSTP/MSTP (IE EE 8 02.1D/w/s)
Redu nd ant Ring (O-Ring) wit h re co ve ry t ime less than 30ms over 250 units
TOS/ Di ffserv supported
Quality of Service (802 .1 p) for real-time traffic
VLAN (802.1Q) with VLAN t ag ging and GVRP support ed
IGMP Snooping
IP-based bandwidt h ma nagement
Application-bas ed Q oS management
DOS/DDOS auto preventio n
Port c on figura tion, status, stati st ics, monitoring, se cu rity
DHCP Server/Client/Relay
SMTP Client
Modbus TCP
Network Redundancy
O-Ring
O-Chain
MRP*Note
MSTP (RSTP/STP comp at ible)
Total PoE budget
LED
Color
Status
Description
PWR Green On DC power module activated
R.M Green On Device operating in Ring Master mode
Ring Green
On Ring enabled
Blinking Ring structure is broken
Fault Amber On Errors occur (i.e. power failure or port malfunctioning)
10/100/1000Base-T(X) P.S.E Ethernet ports
LNK/ACT Green On Port is linked
Blinking Transmitting data
PoE Green On Power supplied over Ethernet
Speed
Green On Port is running at 1000Mbps
Amber On Port is running at 100Mbps
Green/Amber Off Port is running at 10Mbps
10/100/1000Base-T(X) Ethernet ports
LNK/ACT Green On Port is linked
Blinking Transmitting data
Speed
Green On Port is running at 1000Mbps
Amber On Port is running at 100Mbps
Green/Amber Off Port is running at 10Mbps
4 (8-pin fema le X-coding connector with 2 x bypass f unction included)
Up to 9.6K Bytes
Jumbo frame
RS-232 Serial Conso le Port RS-232 in M12 (female A-coding) connec to r wi th c on so le c ab le . 115200bps, 8, N, 1
Powe r Co nsumption(Typ.)
*P .S E. i s no t in cl ud ed.
ORing Industrial Networking Corp.
Copyright© 2019 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com
*Note: This function is available by request only.
TGPS-9164GT-M12X-BP2-MV
72 /110 (50.4~137.5) VDC on 4-pin male S-coding connector
≤8Watts, 72VDC/0.35A (7.56W), 96VDC/0.28A (7.56W), 110VDC/0.25A (7.56W)
95 Watts
2650g
Warranty
5 ye ar s
20 1,768 hrs
EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Par t 15 B cl as s A
EMI
EN 50155 (IEC 61373) Compliant
Other
6
5
7
3
2
1
8
4
10/100/1000Base-T(X) M12 X-coding
Pin No.
Pin Definition
#1
BI_DA+
#2
BI_DA-
#3
BI_DB+
#4
BI_DB-
#5
BI_DD+
#6
BI_DD-
#7
BI_DC-
#8
BI_DC+
10/100/1000Base-T(X) P.S.E. M12
X-coding
Pin No.
Pin Definition
#1
BI_DA+ with PoE Vout+
#2
BI_DA- with PoE Vout+
#3
BI_DB+ with PoE Vout-
#4
BI_DB- with PoE Vout-
#5
BI_DD+
#6
BI_DD-
#7
BI_DC-
#8
BI_DC+
Present
For pin assignments of the Ethernet ports, please refer to the following tables.
EN50155 20-port managed
Gigabit PoE Ethernet switch
TGPS-9164GT-M12X-BP2-MV
TGPS-9164GT-M12X-BP2-MV

Other ORiNG Network Router manuals

ORiNG RES-P3242GCL SERIES User manual

ORiNG

ORiNG RES-P3242GCL SERIES User manual

ORiNG IES-180B User manual

ORiNG

ORiNG IES-180B User manual

ORiNG TES-3082GT-M12-BP1 User manual

ORiNG

ORiNG TES-3082GT-M12-BP1 User manual

ORiNG IGS-3032GC User manual

ORiNG

ORiNG IGS-3032GC User manual

ORiNG RGPS-7244GP User manual

ORiNG

ORiNG RGPS-7244GP User manual

ORiNG IPS-2042FX Series User manual

ORiNG

ORiNG IPS-2042FX Series User manual

ORiNG TAR-120-M12 User manual

ORiNG

ORiNG TAR-120-M12 User manual

ORiNG IGS-9122GPM User manual

ORiNG

ORiNG IGS-9122GPM User manual

ORiNG IES-1080A User manual

ORiNG

ORiNG IES-1080A User manual

ORiNG RGPS-7244GP-P User manual

ORiNG

ORiNG RGPS-7244GP-P User manual

ORiNG RES-3242GC User manual

ORiNG

ORiNG RES-3242GC User manual

ORiNG TGAR-1062PLUS-3GS-M12 User manual

ORiNG

ORiNG TGAR-1062PLUS-3GS-M12 User manual

ORiNG IES-3062GT User manual

ORiNG

ORiNG IES-3062GT User manual

ORiNG CPGS-9080-C User manual

ORiNG

ORiNG CPGS-9080-C User manual

ORiNG IES-2050A User manual

ORiNG

ORiNG IES-2050A User manual

ORiNG IES-3242GC User manual

ORiNG

ORiNG IES-3242GC User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG TGPS-9164GT-M12 User manual

ORiNG

ORiNG TGPS-9164GT-M12 User manual

ORiNG IR-710 User manual

ORiNG

ORiNG IR-710 User manual

ORiNG IES-3080 Series User manual

ORiNG

ORiNG IES-3080 Series User manual

ORiNG IES-2042 Series User manual

ORiNG

ORiNG IES-2042 Series User manual

ORiNG TGPS-9084GT-M12 User manual

ORiNG

ORiNG TGPS-9084GT-M12 User manual

ORiNG RES-9242GC User manual

ORiNG

ORiNG RES-9242GC User manual

Popular Network Router manuals by other brands

DCE 5204AV-MR/K user manual

DCE

DCE 5204AV-MR/K user manual

Huawei AR200-S Series quick start guide

Huawei

Huawei AR200-S Series quick start guide

D-Link DES-1008P Quick installation guide

D-Link

D-Link DES-1008P Quick installation guide

CyberTAN WG414 user guide

CyberTAN

CyberTAN WG414 user guide

Nortel ASN Product support bulletin

Nortel

Nortel ASN Product support bulletin

2-Wire Gateway None user guide

2-Wire

2-Wire Gateway None user guide

H3C CR16000-F Configuration guide

H3C

H3C CR16000-F Configuration guide

SMC Networks FS26 installation guide

SMC Networks

SMC Networks FS26 installation guide

Edimax AR-7084A user manual

Edimax

Edimax AR-7084A user manual

Asus RT-AC66U user guide

Asus

Asus RT-AC66U user guide

Advantech SmartMotion ST352 user manual

Advantech

Advantech SmartMotion ST352 user manual

Proxim TeraBridge 5845 Specifications

Proxim

Proxim TeraBridge 5845 Specifications

Allied Telesis AR 300  AT-AR300 AT-AR300 Release manual

Allied Telesis

Allied Telesis AR 300 AT-AR300 AT-AR300 Release manual

Siemens RUGGEDCOM RS900 installation guide

Siemens

Siemens RUGGEDCOM RS900 installation guide

Hayes ADSL Ethernet Modem user guide

Hayes

Hayes ADSL Ethernet Modem user guide

Cisco WGA54G Quick installation guide

Cisco

Cisco WGA54G Quick installation guide

LAWO POWER CORE user manual

LAWO

LAWO POWER CORE user manual

Allied Telesis AR725 Installation and safety guide

Allied Telesis

Allied Telesis AR725 Installation and safety guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.