IGS-9164GF
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
G20
G19
G18
G17
1000FX
G16
G14
G12
G10
G15
G13
G11
G9
Quick Installation Guide
Version 1.1
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
QIG
The is a managed industrial Ethernet switch with
16x10/100/1000Base-T(X) ports and 4 fixed optical fiber ports. The IGS-
9164GF provides 4x1000Base-X fiber ports and the IGS-9164FX provides
4x100Base-FX fiber ports. The cost-effective device with a high port density
can be managed centrally via web browsers, TELNET, Console or other
third-party SNMP software as well as Oring’s proprietary Open-Vision
management utility. With complete support for Ethernet redundancy
protocols such as O-Ring (recovery time < 30ms over 250 units of
connection) and MSTP (RSTP/STP compatible), the devices can protect
your mission-critical applications from network interruptions or temporary
malfunctions with its fast recovery technology. Boasting a wide operating
temperature from -40 C to 75 C, the switch can meet the demanding
requirements of power substations and rolling stock applications.
IGS-9164GF/FX series
oo
Dimension
Panel Layouts
11
1. Power LED
2. PWR1 LED
3. PWR2 LED
4. R.M. status LED
5. Ring status LED
6. Faulty relay indicator
7. Console port
8. Optical fiber ports
9. LNK/ACT indicator for
fiber ports
10. LNK/ACT indicator for
LAN ports
11. Ethernet LAN ports
12. Speed indicator for LAN
ports
13. Reset button
Package Contents
Contents
DIN-rail Kit
CD
IGS-9164GF/FX
Pictures Number
X1
X1
X1
Front View
Top Panel
The are shipped with the following items. If any of
these items is missing or damaged, please contact your customer service
representative for assistance.
IGS-9164GF/FX eries
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
QIG
Console Cable
X2
X1
X1
Wall-mount Kit
33.0
30.0
12.5
105.5
10.9
15.0
70.5
154.0
96.4
87.0
48.0
17.5
94.0
124.0
48.0
58.0
7.50
R2.5
R3.95
66.25
48.75
95.9
10
8
7
1
2
3
4
5
6
Rear View
12
PWR-1PWR-2
1A@24V
DC48V
V2-V2+ V1-V1+
Fault
1
1. Wall-mount screw holes
2. Din-rail screw holes
2
1. Terminal blocks: PWR1, PWR2
(12-48V DC), Relay
2. Ground wire.
1
Installation
Step 1:
Step 2:
Slant the switch and screw the Din-rail kit onto the back of the switch, right in
the middle of the back panel.
Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch
clicks into the rail firmly.
DIN-rail Installation
Step 1:
Step 2:
Step 3:
Screw the two pieces of wall-mount kits onto both ends of the rear panel of the
switch. A total of six screws are required, as shown below.
Use the switch, with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Insert four screw heads through the large parts of the keyhole-shaped apertures,
and then slide the switch downwards. Tighten the four screws for added stability.
Wall-mounting
IGS-9164GF/FX Series 1907-2-29-IGS9164GF-1.1
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch
uses CAT 3, 4, 5, 5e UTP cables to connect to any other network devices (PCs,
servers, switches, routers, or hubs). Please refer to the following table for cable
specifications.
Cable Types and Specifications:
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm U TP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (3 28 ft) R J-45
IGS-9164GF/FX Series
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient:
Reduced Air Flow:
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Safety & Warnings
Mechanical Loading:
Circuit Overloading:
Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
IGS-9164GF
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
G20
G19
G18
G17
1000FX
G16
G14
G12
G10
G15
G13
G11
G9
9
12
IGS-9164GF
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
G20
G19
G18
G17
1000FX
G16
G14
G12
G10
G15
G13
G11
G9
13
IGS-9164FX
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
P20
P19
P18
P17
100FX
G16
G14
G12
G10
G15
G13
G11
G9
IGS-9164FX
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
P20
P19
P18
P17
100FX
G16
G14
G12
G10
G15
G13
G11
G9
11
10
8
7
1
2
3
4
5
6
9
12
13
QIG Quick Installation Guide
PRINTED ON RECYCLED PAPER
Version 1.1
Quick Installation Guide
Resetting
To reboot the switch, press the button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the button for 5 seconds.
Reset
Reset
Specifications
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
For pin assignments for different types of cables, please refer to the following
tables.
1000Base-T RJ-45
Pin Number Assignment
1BI_DA+
2BI_DA-
3BI_DB+
4BI_DC+
5BI_DC-
6BI_DB-
7BI_DD+
8BI_DD-
10/100Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X port
1TD+(transmit)RD+(receive)
2TD-(transmit)RD-(receive)
3 RD+(receive) TD+(transmit)
4NotusedNotused
5NotusedNotused
6 RD-(receive) TD-(transmit)
7NotusedNotused
8NotusedNotused
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment RS-232 with DB9 (female) pin
assig nment (RJ45-DB9 cable) RJ45 pin assignment
PIN#2 RxD PIN#2 RxD PIN#2 RxD
PIN#3TxD PIN#3TxD PIN#3TxD
PIN#5 GND PIN#5 GND PIN#5 GND
Configurations
After installing the switch card, the green power LED should turn on. Please refer to the
following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password
(both are ). After logging in, you should
see the following screen. For more information
on configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.
admin
Follow the steps to set up the device:
ORing Switch Model IGS-9164GF-MM-SC
Physical Ports
Fiber Ports Number
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3z for 1000Base-X
IEEE 802.3ab for 1000Base-T
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.3x for Flow control
IEEE 802.1p for COS (Class of service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
Power
Redundant Input power
Power consumption(Typ.)
Dual DC inputs. 12-48VDC on 6-pin terminal block
16.32 Watts
Overload current protection
Reverse polarity protection
Present
Present
Physical Characteristic
Enclosure IP-30
Dimension(WxDxH) 96.4 (W) x 105.5(D) x 154(H) mm (3.8 x 4.15 x 6.06 inch)
10/100/1000Base-T(X) Ports
in RJ-45 Auto MDI/MDIX
MAC Table 8K
RS-232 Serial Console Port
Priority Queues 8
Processing Store-and-Forward
Switch Properties
Switch latency: 7 us
Switch bandwidth: 40Gbps
Max. Number of Available VLANs: 256
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
Security Features
Device Binding security feature
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
Software Features
STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCP Server / Client support
SMTP Client
Modbus TCP
Network Redundancy O-Ring, Open-Ring, O-chain, MRP, MSTP (RSTP/STP compatible), Fast Recovery
RS-232 in RJ45 connector with console cable. Baud rate setting: 115200bps, 8, N, 1
Fiber Ports Specification
Fiber Ports Standard 1000Base-SX
Fiber Mode Multi-mode Single-mode
Fiber Diameter ( m)µ62.5/125 m
50/125 m
µ
µ
Fiber Optical Connector SC SC
Typical Distance (Km) 0.55 Km 30 Km
Wavelength (nm) 850 nm 1310 nm
Max. Output Optical Power
(dbm) -8 dbm
Min. Output Optical Power
(dbm) -15 dbm
Optical Input Power-
minimum (Sensitivity) -34 dbm
0dbm -0dbm
-18 dbm
Optical Input Power-
maximum (Saturation)
Link Budget (db) 8.5 db 19 db
Weigh t (g) 1243 g
16
9/125 mµ
IGS-9164FX-SS-SC
4
Processing Up to 9.6K Bytes
Fault Contact
Relay Relay output to carry capacity of 1A at 24VDC
Weigh t (g) 710 g 740 g722 g 735 g 735 g 740 g
Environmental
-40to85 C(-40to185 F)
oo
Storage Temperature
-40to75 C(-40to167 F)
oo
Operating Temperature
5% to 95% Non-condensingOperating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class AEMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
IEC60068-2-27Shock
IEC60068-2-32
IEC60068-2-6Vibration
EN60950-1
Safety
Free Fall
Warranty
5 years
100Base-FX
10/100Base-T(X) RJ-45
Pin Numb er Assignment
1TD+
2TD-
3RD+
4Notused
5Notused
6RD-
7Notused
8Notused
1000Base-T MDI/MDI-X
Pin Number MDI port MDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
-4 dbm
-9.5 dbm
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
STEP 1:
STEP 2:
PWR-1PWR-2
1A@24V
V2-V2+ V1-V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.
Relay contact
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
ORing Industrial Networking Corp.
Copyright© 2014 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
LED Col or Status Description
PWR Green On DC power on
PW1 Green On DC power modul e 1 activated
PW2 Green On DC power modul e 2 activated
R.M Gre en On System r unning in Rin g Master mode
On System running in Rin g mode
Ring Green
Blink ing R ing stru cture is broken
Fault Amber On Faulty rel ay (power failure or p ort malfunctioni ng)
10/100 /1000Base-T(X) Et hernet ports
On Port is connected
LNK/ ACT Gre en Blinking Transmitting data
Green On Port is runnin g at 1000Mbps
Amber On Port is runnin g at 100Mbps
Speed
Off P ort i s running at 10Mbps
1000Base-X or 100Base-FX fiber ports
On Port is connected
LNK/ ACT Gre en
Blinking Transmi tting data
Single-mode
SC
10 Km
1310 nm
-3 dbm
-9.5 dbm
-20 dbm
-3 dbm
10.5 db
9/125 mµ
IGS-9164GF-SS-SC
1000Base-LX
IGS-9164FX-MM-SC
100Base-FX
Multi-mode
62.5/125 m
50/125 m
µ
µ
SC
2Km
1310 nm
0dbm
-31 dbm
7.5 db
-14 dbm
-23.5 dbm
18.5 Watts
1228 g
IGS-9164GF/FX Series
IGS-9164GF/FX Series

This manual suits for next models

5

Other ORiNG Switch manuals

ORiNG RES-3242GC User manual

ORiNG

ORiNG RES-3242GC User manual

ORiNG TGPS-9084GT-M12 User manual

ORiNG

ORiNG TGPS-9084GT-M12 User manual

ORiNG IES-2060 Series User manual

ORiNG

ORiNG IES-2060 Series User manual

ORiNG IPS-3082GC-AT User manual

ORiNG

ORiNG IPS-3082GC-AT User manual

ORiNG IGPS-9084GP-LA User manual

ORiNG

ORiNG IGPS-9084GP-LA User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG TGPS-9084GT-M12X-BP2-MV User manual

ORiNG

ORiNG TGPS-9084GT-M12X-BP2-MV User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG IES-180-L User manual

ORiNG

ORiNG IES-180-L User manual

ORiNG TGXPS-1080-M12-24V Series User manual

ORiNG

ORiNG TGXPS-1080-M12-24V Series User manual

ORiNG IGPS-1041GTA User manual

ORiNG

ORiNG IGPS-1041GTA User manual

ORiNG RGS-7244GP User manual

ORiNG

ORiNG RGS-7244GP User manual

ORiNG IGS-1042GPA User manual

ORiNG

ORiNG IGS-1042GPA User manual

ORiNG IPS-1080-24V User manual

ORiNG

ORiNG IPS-1080-24V User manual

ORiNG TPS-1080-M12 User manual

ORiNG

ORiNG TPS-1080-M12 User manual

ORiNG IGS-1042GPA User manual

ORiNG

ORiNG IGS-1042GPA User manual

ORiNG IES-2050 User manual

ORiNG

ORiNG IES-2050 User manual

ORiNG IPS-3082GC-24V User manual

ORiNG

ORiNG IPS-3082GC-24V User manual

ORiNG TES-3080-M12 Series User manual

ORiNG

ORiNG TES-3080-M12 Series User manual

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG TPS-3162GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3162GT-M12-BP1 User manual

ORiNG IGPS-9084GP User manual

ORiNG

ORiNG IGPS-9084GP User manual

ORiNG TGS-1080-M12 Series User manual

ORiNG

ORiNG TGS-1080-M12 Series User manual

ORiNG TES-W9124GT-M12X-BP2-24V-IP54 User manual

ORiNG

ORiNG TES-W9124GT-M12X-BP2-24V-IP54 User manual

Popular Switch manuals by other brands

Intellinet 561792 instructions

Intellinet

Intellinet 561792 instructions

Ascent Communication Technology AT5000 OPSW Quick reference guide

Ascent Communication Technology

Ascent Communication Technology AT5000 OPSW Quick reference guide

Transition Networks LAN MASTER 33022.B user manual

Transition Networks

Transition Networks LAN MASTER 33022.B user manual

See Water Oil Smart OSS20R6 quick start guide

See Water

See Water Oil Smart OSS20R6 quick start guide

IMC Networks IE-MiniMc LFPT Operation manual

IMC Networks

IMC Networks IE-MiniMc LFPT Operation manual

Belkin OMNIVIEW PRO3 F1DA208ZEA Quick install guide

Belkin

Belkin OMNIVIEW PRO3 F1DA208ZEA Quick install guide

Digicom DUAL SPEED SWITCH 24 user guide

Digicom

Digicom DUAL SPEED SWITCH 24 user guide

impinj R700 quick start guide

impinj

impinj R700 quick start guide

Avocent AutoView 416 Installer/user guide

Avocent

Avocent AutoView 416 Installer/user guide

Raritan Dominion KX IV-101 Package Contents

Raritan

Raritan Dominion KX IV-101 Package Contents

Siemens RUGGEDCOM RSG909R installation manual

Siemens

Siemens RUGGEDCOM RSG909R installation manual

Rutenbeck SR 5TX GB installation instructions

Rutenbeck

Rutenbeck SR 5TX GB installation instructions

Cisco ME 3400 Hardware installation guide

Cisco

Cisco ME 3400 Hardware installation guide

MuxLab LongReach II 500126 installation guide

MuxLab

MuxLab LongReach II 500126 installation guide

H3C S5120-SI Series Configuration guide

H3C

H3C S5120-SI Series Configuration guide

Brocade Communications Systems 7840 quick start guide

Brocade Communications Systems

Brocade Communications Systems 7840 quick start guide

Fortinet FortiSwitch-28C Administration guide

Fortinet

Fortinet FortiSwitch-28C Administration guide

Zte MC8010CA user manual

Zte

Zte MC8010CA user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.