ORiNG IES-3160 User manual

IES-3160
P1
P3
P5
P1
P3
P2
P4
P6
P8
P7
P13
P9
P11
P10
P12
P14
P16P15
PWR
PWR 1
PWR 2
Quick Installation Guide
Version 2.1
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
Q I G
is managed Redundant Ring Ethernet switch with 16x10/100Base-IES-3160
T(X) ports. With completely support of Ethernet Redundancy protocol, O-
Ring (recovery time < 10ms over 250 units of connection), O-Chain,
MRP and MSTP/RSTP/STP (IEEE 802.1s/w/D) can protect your*NOTE
mission-critical applications from network interruptions or temporary
malfunctions with its fast recovery technology. O-Chain is the revolutionary
netw ork redu ndancy te chnolo gy that pr o vides th e add-on n etwork
redundancy topology for any backbone network, O-Chain allows multiple
redundant network rings of different redundancy protocols to join and
function together as a larger and more robust compound network topology.
O-Chain providing ease-of-use while maximizing fault-recovery swiftness,
flexibility, compatibility, and cost-effectiveness in one set of network
redundancy topology. All function of can be managed centralizedIES-3160
and convenient by a powerful windows utility — Open-Vision. In addition, the
wide operating temperature range from -40 to 75 C can satisfy most of
o
operating environment. Therefore, the switch is one of the most reliable
choice for highly-managed Ethernet application.
Package Contents
The device is shipped with the following items. If any of these items is missing
or damaged, please contact your customer service representative for
assistance.
Preparation
Before you begin installing the device, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient: If installed in a closed environment, make sure
the operating ambient temperature is compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Safety & Warnings
Dimension
Panel Layouts
Front View
IES-3160 1907-200-XX
Contents
Console Cable
CD
IES-3160
Pictures Number
X 1
X 1
X 1
QIG
X 2
X 1
Wall-mount Kit
Rear View
1. Din-rail screw holes
2. Wall-mount screw holes
Step 1: Screw the two pieces of wall-mount kits onto both ends of the rear panel of the
device. A total of six screws are required, as shown below.
Step 2: Use the device, with wall mount plates attached, as a guide to mark the
correct locations of the wall-mounting screws.
Step 3: Insert a screw head through the large part of the keyhole-shaped aperture on the
plate, and then slide the device downwards. Tighten the screw for added stability.
Wall-mounting
Step 1: Slant the device and screw the Din-rail kit onto the back of the device, right in the
middle of the back panel.
Step 2: Slide the device onto a DIN-rail from the Din-rail kit and make sure the device clicks
into the rail firmly.
DIN-rail Installation
1
2
2
Bottom View
1
2
1. Terminal block
2. Grounding screw
Installation
66.0
50.0
26.0
43.043.0 43.0
74.3
116. 0
40.0
18.0
107.5
153.6
74.3
8.0
80.5
Unit =mm (Tolerance ±0.5mm)
X 1
DIN-rail Kit
IES-3160 Industrial Managed Ethernet Switch
S W I T C H
I N D U S T R I A L
*NOTE : This function is available by request only.
The product is open type, intended to be installed in and industrial control panel or an
enclosure.
Reduced Air Flow: Make sure the amount of air flow required for safe operation of the
equipment is not compromised during installation.
Mechanical Loading: Make sure the mounting of the equipment is not in a hazardous
condition due to uneven mechanical loading
Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
IES-3160
P1
P3
P5
P1
P3
P2
P4
P6
P8
P7
P13
P9
P11
P10
P12
P14
P16P15
PWR
PWR1
PWR2
7
1
2
3
4
5
6
10
8
9
11
1. Power LED
2. PWR1 LED
3. PWR2 LED
4. R.M. status LED
5. Ring status LED
6. Faulty relay indicator
7. Console port
8. Link/Act LED for Ethernet port
9. Full/Half-duplex indicator
10. LAN ports
11. Reset button
PWR -1PWR -2
1A@ 24V
DC1 2-4 8V
V2- V 2+ V1- V 1+
Fau lt
IES-3160
P1
P3
P5
P1
P3
P2
P4
P6
P8
P7
P13
P9
P11
P10
P12
P14
P16P15
PWR
PWR1
PWR2
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch uses CAT
3,4,5,5e UTP cables to connect to any other network devices (PCs, servers, switches,
routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications:
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
Q I G Quick Installation Guide
Quick Installation Guide
Q I G PRINTED ON RECYCLED PAPER
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X port
1 TD+(transmit) RD+(receive)
2 TD-(transmit) RD-(receive)
3 RD+(receive) TD+(transmit)
4 Not used Not used
5 Not used Not used
6 RD-(receive) TD-(transmit)
7 Not used Not used
8 Not used Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment RS-232 with DB9 (female) pin
assignment (RJ45-DB9 cable) RJ45 pin assignment
PIN#2 RxD PIN#2 RxD PIN#2 RxD
PIN#3 TxD PIN#3 TxD PIN#3 TxD
PIN#5 GND PIN#5 GND PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1: Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1PWR-2
1A@24 V
V2- V2+ V1- V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.
Relay contact
10/100 Base-T(X) RJ-45 Port
Pin Number Assignments
1 TD+
2 TD-
3 RD+
4 Not used
5 Not used
6 RD-
7 Not used
8 Not used
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
ORing Industrial Networking Corp.
Copyright© 2010 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Address 3F No 542 2 Zhongzheng Rd Xindian Dist New: ., . - , ., .,
Taipei City 23148 Taiwan,
Website: www.oringnet.com
E-mail: support@oringnet.com
Contact for maintenance and repair service:
Resetting
To reboot the switch, press the button less than 5 seconds.Reset
To restore the switch configurations back to the factory defaults, press the button more than 5Reset
seconds.
Specifications
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password
(both are ). After logging in, you shouldadmin
see the following screen. For more information
on configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.
Follow the steps to set up the switch:
ORi ng Switch Mod e l
Phy sical Ports
Tec hnology
Et herne t Stand ards
10 /100 Ba se-T(X ) Port s in RJ45
Au to MDI/ MDIX
RS -232 Se rial Co nsole Port
Sw itch Pr opert ies
Se curit y Feat ures
En able/ disable ports , MAC bas ed port s ecuri ty
Port bas ed netw ork acc ess con trol (8 02.1x )
VL AN (802 .1Q) to s egregate and se cure ne twork t raff ic
Su pport s Q-in-Q VLAN for perfor mance & s ecuri ty to exp and the V LAN spa ce
Radius c entralize d passw ord man ageme nt
SN MP V1/V 2c/V3 e ncrypt ed auth entic ation a nd acce ss secu rity
So ftwar e Fea tures
ST P/RST P/MSTP ( IEEE 80 2.1D/ w/s)
Redund ant Rin g (O-Ri ng) wit h recovery tim e less th an 10ms over 25 0 units
TOS/Di ffser v suppo rted
Qu ality o f Servi ce (802 .1p) fo r real- time traffi c
VL AN (802 .1Q) wi th VLAN t agging a nd GVRP s uppor ted
IG MP Snoo ping fo r multicast fil terin g
Port con figuratio n, stat us, sta tisti cs, monitorin g, secu rity
SN TP for sy nchro nizing o f clock s over n etwor k
Su pport P TP Clie nt (Prec ision T ime Pro tocol ) clock s ynchr oniza tion
DH CP Serv er / Clie nt supp ort
Port Trunk sup port
MV R (Mult icast V LAN Re gistratio n) supp ort
Mo dbus TCP
Ne twork Redun dancy O- Ring, O -Chain , MRP , MS TP/RS TP/STP*N OTE
RS -232 in R J45 con nector with con sole ca ble. 96 00bps , 8, N, 1
IES -3160
16
IE EE 802. 3 for 10B ase-T
IE EE 802. 3u for 10 0Base-TX
IE EE 802. 3x for Fl ow contr ol
IE EE 802. 3ad for L ACP (Link Aggre gatio n Contr ol Prot ocol)
IE EE 802. 1D for ST P (Spanning Tree Prot ocol)
IE EE 802. 1p for CO S (Class o f Servi ce)
IE EE 802. 1Q for VL AN Tag ging
IE EE 802. 1w for RS TP (Rapid Span ning Tree Pro tocol )
IE EE 802. 1s for MS TP (Mult iple Sp annin g Tree P rotoc ol)
IE EE 802. 1x for Au thent icati on
IE EE 802. 1AB for L LDP (Li nk Layer Discovery P rotoc ol)
Sw itch la tency : 2.98 us
Sw itch ba ndwid th: 3.2 Gbps
Th rough put (pac ket pe r secon d):2. 381Mp ps@64Bytes pa cket
Ma x. Numb er of Availa ble VLA Ns: 409 6
VL AN ID Ra nge: VI D 1 to 4095
IG MP mult icast g roups: 1 024
Port ra te limi ting: U ser Def ine
MA C Tabl e 8K
Pr ocess ing Store-an d-Fo rwar d
Packe t buffe r 1M bits
Env ironmental
-4 0 to 85 C ( -40 to 185 F)
o o
St orag e Temp erat ure
Op erat ing Temperature
5% t o 95% Non -cond ensingOp erat ing Hum idity
Reg ulatory appr ovals
EN 5 5032, C ISPR3 2, EN 61000-3-2 , EN 6100 0-3-3 , FCC Part 15 B cl ass AEM I
EN 5 5024 (I EC/EN 61000-4 -2 (ESD : Conta ct 4KV, Air 8KV), IE C/EN 61 000-4 -3 (RS: 3 V),
IE C/EN 61 000-4- 4 (EFT Power 0. 5KV, Sign al 0.5K V), IEC /EN 610 00-4-5 ( Surge : Pow er 0.5K V, RJ45 1KV ),
IE C/EN 61 000-4- 6 (CS: 3V ), IEC/ EN 6100 0-4-8 (PFMF ), IEC/ EN 6100 0-4-11 ( DIP))
EN 6 1000- 6-2 (IE C/EN 610 00-4- 2 (ESD: C ontac t 4KV), I EC/EN 6 1000- 4-3 (RS: 10V),
IE C/EN 61 000-4- 4 (EFT Power 2K V, Signal 1 KV), IE C/EN 61 000-4-5 (Surg e: Po wer 1KV, RJ 45 1KV) ,
IE C/EN 61 000-4- 6 (CS: 10 V), IEC /EN 610 00-4- 8(PFM F), IEC /EN 610 00-4-1 1 (DIP) )
EM S
IE C6006 8-2-27Sh ock
IE C6006 8-2-31
IE C6006 8-2-6Vi brat ion
EN 60950 -1, UL6 1010-1 , UL-61 010-2 -201
Sa fety
Fr ee Fall
MTB F
88 6987. 2626 hr s
-4 0 to 75 C ( -40 to 167 F)
o o
Fau lt contact
Relay Relay o utput t o carry c apaci ty of 1A at 2 4 VDC
Pow er
Redund ant Inp ut powe r
Power co nsump tion( Typ. ) 15 Wa tts, 12- 48VDC /1.2A-0.3A
Ov erloa d curre nt prot ectio n
Rever se polarity pr otect ion
Pr esent
Pr esent o n termi nal blo ck
Phy sical Charac teristic
En closu re IP-30 A lumin um (non U L certi fied)
Di mensi on (W x D x H)
Weig ht (g) 10 60 g
Du al DC inp uts 12- 48VDC o n 6-pin termina l block
* Su pplie d by SELV sou rce evaluat ed by UL 61 010-1 o r 61010 -2-20 1 power s upply only.
* Fourni p ar la sou rce SELV évalué e uniqu ement p ar l'al iment ation U L 61010 -1 or 610 10-2- 201.
74 .3 (W) x 10 7.5 (D) x 1 53.6 (H )mm (2. 93x4.2x6.05 inch.)
Pr iorit y Queue s 4
Res et Function
Reset Bu tton < 5 se c: Sys tem reboot, > 5 sec : Fa ctory d efaul t
CE E MC (EN 55 024, EN 5 5032), FCC Pa rt 15 BEMC
War ranty
*NOTE : This function is avail able by reque st only
!
Up t o 2000mOp erat ing Alt titude
5 ye ars
!
Warning [AVERTISSEMENT]
Take into consideration the following guidelines before wiring the device
[Tenez compte des directrices suivantes avant de câbler l’appareil.]
1. Terminal block is mating with Plug and suitable for 12-24AWG. Torque value 4.5 lb-in.
[Le bornier est compatible avec les connecteurs et convient pour 12-24AWG.
Valeur de couple 4,5 lb-in.]
2. The temperature rating of the input connection cable should higher than 105°C
[La température de service nominale du câble d’entrée doit être supérieure à 105 °C]
* Indoor use and pollution degree II, it must be wiped with a dry cloth for clean up the device and label.
* Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un chiffon sec pour nettoyer
l'appareil et son étiquette.
* Do not block air ventilation holes.
* Ne bouchez pas les orifices de ventilation.
* If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.”
* Si l’appareil est utilise d’une maniere non specifiee par le fabricant, la protection qu’il apporte peut se
voir diminuee.”
* Shall be mounted in the Industrial Control Panel and ambient temperature is not exceed 75 degree C
* doit être monté dans le panneau de commande industriel et la température ambiante ne doit pas
dépasser 75 degrés C
Version 2.1
IES-3160
IES-3160 Industrial Managed Ethernet Switch
S W I T C H
I N D U S T R I A L
LED
Color
Status
Description
PWR Green On DC power on
PWR1 Green On DC power module 1 activated
PWR2 Green On DC power module 2 activated
R.M Green On Ring Master
Ring Green
On Ring enabled
Blinking Ring structure is broken (i.e. part of the ring is disconnected)
Fault Amber On Faulty relay (power failure or port disconnected)
10/100Base-T(X) Ethernet ports
LNK/ACT
with speed
Green
On Port link up
Blinking Data transmitted
Amber
On Full-duplex mode
Off Half-duplex mode
Blinking Half-duplex mode and collision occurred

Other ORiNG Switch manuals

ORiNG IGS-1042GPA User manual

ORiNG

ORiNG IGS-1042GPA User manual

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG IGS-9844GPFX Series User manual

ORiNG

ORiNG IGS-9844GPFX Series User manual

ORiNG IGPS-9084GP User manual

ORiNG

ORiNG IGPS-9084GP User manual

ORiNG IES-3080 Series User manual

ORiNG

ORiNG IES-3080 Series User manual

ORiNG RGS-R9004GP+ME-HV User manual

ORiNG

ORiNG RGS-R9004GP+ME-HV User manual

ORiNG TPS-1080-M12 User manual

ORiNG

ORiNG TPS-1080-M12 User manual

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG IGPS-9822DGP+ User manual

ORiNG

ORiNG IGPS-9822DGP+ User manual

ORiNG IES-2050-M12 User manual

ORiNG

ORiNG IES-2050-M12 User manual

ORiNG IGPS-1041GTA User manual

ORiNG

ORiNG IGPS-1041GTA User manual

ORiNG TGPS-9084GT-M12 User manual

ORiNG

ORiNG TGPS-9084GT-M12 User manual

ORiNG IGPS-1080A User manual

ORiNG

ORiNG IGPS-1080A User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG IPS-1080A User manual

ORiNG

ORiNG IPS-1080A User manual

ORiNG IGPS-9084GP-LA User manual

ORiNG

ORiNG IGPS-9084GP-LA User manual

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG IES-2050 User manual

ORiNG

ORiNG IES-2050 User manual

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG IES-3240 User manual

ORiNG

ORiNG IES-3240 User manual

ORiNG IPS-1080-24V User manual

ORiNG

ORiNG IPS-1080-24V User manual

ORiNG RGS-7244GP User manual

ORiNG

ORiNG RGS-7244GP User manual

ORiNG IPS-2042TX Series User manual

ORiNG

ORiNG IPS-2042TX Series User manual

Popular Switch manuals by other brands

IOGear GWU647 installation guide

IOGear

IOGear GWU647 installation guide

Brigade CQS-100C owner's guide

Brigade

Brigade CQS-100C owner's guide

HP 263924-002 user guide

HP

HP 263924-002 user guide

Emerson PACSystems SLM080 user manual

Emerson

Emerson PACSystems SLM080 user manual

Aluratek AKSUP02 quick start guide

Aluratek

Aluratek AKSUP02 quick start guide

Hama USB Hub operating instructions

Hama

Hama USB Hub operating instructions

Terra SRM524 manual

Terra

Terra SRM524 manual

Cooper Wiring Devices 6109 user manual

Cooper Wiring Devices

Cooper Wiring Devices 6109 user manual

SilverStone EP01 manual

SilverStone

SilverStone EP01 manual

Planex SWE-0224G2 user manual

Planex

Planex SWE-0224G2 user manual

Salus miniSmartPlug user guide

Salus

Salus miniSmartPlug user guide

iPuray BRT-611 quick start guide

iPuray

iPuray BRT-611 quick start guide

ALFAtron ALF-SCU91T-N user manual

ALFAtron

ALFAtron ALF-SCU91T-N user manual

Cabletron Systems 6H122-08 user guide

Cabletron Systems

Cabletron Systems 6H122-08 user guide

HP GbE2c Specifications

HP

HP GbE2c Specifications

NETGEAR EN516 - Hub - EN Installation

NETGEAR

NETGEAR EN516 - Hub - EN Installation

Belden ThinkLogical TLX12 product manual

Belden

Belden ThinkLogical TLX12 product manual

Mellanox Technologies MIS5600Q-10DNC installation guide

Mellanox Technologies

Mellanox Technologies MIS5600Q-10DNC installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.