Q I G Quick Installation Guide
Quick Installation Guide
Q I G PRINTED ON RECYCLED PAPER
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X port
1 TD+(transmit) RD+(receive)
2 TD-(transmit) RD-(receive)
3 RD+(receive) TD+(transmit)
4 Not used Not used
5 Not used Not used
6 RD-(receive) TD-(transmit)
7 Not used Not used
8 Not used Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment RS-232 with DB9 (female) pin
assignment (RJ45-DB9 cable) RJ45 pin assignment
PIN#2 RxD PIN#2 RxD PIN#2 RxD
PIN#3 TxD PIN#3 TxD PIN#3 TxD
PIN#5 GND PIN#5 GND PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1: Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1PWR-2
1A@24 V
V2- V2+ V1- V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.
Relay contact
10/100 Base-T(X) RJ-45 Port
Pin Number Assignments
1 TD+
2 TD-
3 RD+
4 Not used
5 Not used
6 RD-
7 Not used
8 Not used
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
ORing Industrial Networking Corp.
Copyright© 2010 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Address 3F No 542 2 Zhongzheng Rd Xindian Dist New: ., . - , ., .,
Taipei City 23148 Taiwan,
Website: www.oringnet.com
E-mail: support@oringnet.com
Contact for maintenance and repair service:
Resetting
To reboot the switch, press the button less than 5 seconds.Reset
To restore the switch configurations back to the factory defaults, press the button more than 5Reset
seconds.
Specifications
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password
(both are ). After logging in, you shouldadmin
see the following screen. For more information
on configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.
Follow the steps to set up the switch:
ORi ng Switch Mod e l
Phy sical Ports
Tec hnology
Et herne t Stand ards
10 /100 Ba se-T(X ) Port s in RJ45
Au to MDI/ MDIX
RS -232 Se rial Co nsole Port
Sw itch Pr opert ies
Se curit y Feat ures
En able/ disable ports , MAC bas ed port s ecuri ty
Port bas ed netw ork acc ess con trol (8 02.1x )
VL AN (802 .1Q) to s egregate and se cure ne twork t raff ic
Su pport s Q-in-Q VLAN for perfor mance & s ecuri ty to exp and the V LAN spa ce
Radius c entralize d passw ord man ageme nt
SN MP V1/V 2c/V3 e ncrypt ed auth entic ation a nd acce ss secu rity
So ftwar e Fea tures
ST P/RST P/MSTP ( IEEE 80 2.1D/ w/s)
Redund ant Rin g (O-Ri ng) wit h recovery tim e less th an 10ms over 25 0 units
TOS/Di ffser v suppo rted
Qu ality o f Servi ce (802 .1p) fo r real- time traffi c
VL AN (802 .1Q) wi th VLAN t agging a nd GVRP s uppor ted
IG MP Snoo ping fo r multicast fil terin g
Port con figuratio n, stat us, sta tisti cs, monitorin g, secu rity
SN TP for sy nchro nizing o f clock s over n etwor k
Su pport P TP Clie nt (Prec ision T ime Pro tocol ) clock s ynchr oniza tion
DH CP Serv er / Clie nt supp ort
Port Trunk sup port
MV R (Mult icast V LAN Re gistratio n) supp ort
Mo dbus TCP
Ne twork Redun dancy O- Ring, O -Chain , MRP , MS TP/RS TP/STP*N OTE
RS -232 in R J45 con nector with con sole ca ble. 96 00bps , 8, N, 1
IES -3160
16
IE EE 802. 3 for 10B ase-T
IE EE 802. 3u for 10 0Base-TX
IE EE 802. 3x for Fl ow contr ol
IE EE 802. 3ad for L ACP (Link Aggre gatio n Contr ol Prot ocol)
IE EE 802. 1D for ST P (Spanning Tree Prot ocol)
IE EE 802. 1p for CO S (Class o f Servi ce)
IE EE 802. 1Q for VL AN Tag ging
IE EE 802. 1w for RS TP (Rapid Span ning Tree Pro tocol )
IE EE 802. 1s for MS TP (Mult iple Sp annin g Tree P rotoc ol)
IE EE 802. 1x for Au thent icati on
IE EE 802. 1AB for L LDP (Li nk Layer Discovery P rotoc ol)
Sw itch la tency : 2.98 us
Sw itch ba ndwid th: 3.2 Gbps
Th rough put (pac ket pe r secon d):2. 381Mp ps@64Bytes pa cket
Ma x. Numb er of Availa ble VLA Ns: 409 6
VL AN ID Ra nge: VI D 1 to 4095
IG MP mult icast g roups: 1 024
Port ra te limi ting: U ser Def ine
MA C Tabl e 8K
Pr ocess ing Store-an d-Fo rwar d
Packe t buffe r 1M bits
Env ironmental
-4 0 to 85 C ( -40 to 185 F)
o o
St orag e Temp erat ure
Op erat ing Temperature
5% t o 95% Non -cond ensingOp erat ing Hum idity
Reg ulatory appr ovals
EN 5 5032, C ISPR3 2, EN 61000-3-2 , EN 6100 0-3-3 , FCC Part 15 B cl ass AEM I
EN 5 5024 (I EC/EN 61000-4 -2 (ESD : Conta ct 4KV, Air 8KV), IE C/EN 61 000-4 -3 (RS: 3 V),
IE C/EN 61 000-4- 4 (EFT Power 0. 5KV, Sign al 0.5K V), IEC /EN 610 00-4-5 ( Surge : Pow er 0.5K V, RJ45 1KV ),
IE C/EN 61 000-4- 6 (CS: 3V ), IEC/ EN 6100 0-4-8 (PFMF ), IEC/ EN 6100 0-4-11 ( DIP))
EN 6 1000- 6-2 (IE C/EN 610 00-4- 2 (ESD: C ontac t 4KV), I EC/EN 6 1000- 4-3 (RS: 10V),
IE C/EN 61 000-4- 4 (EFT Power 2K V, Signal 1 KV), IE C/EN 61 000-4-5 (Surg e: Po wer 1KV, RJ 45 1KV) ,
IE C/EN 61 000-4- 6 (CS: 10 V), IEC /EN 610 00-4- 8(PFM F), IEC /EN 610 00-4-1 1 (DIP) )
EM S
IE C6006 8-2-27Sh ock
IE C6006 8-2-31
IE C6006 8-2-6Vi brat ion
EN 60950 -1, UL6 1010-1 , UL-61 010-2 -201
Sa fety
Fr ee Fall
MTB F
88 6987. 2626 hr s
-4 0 to 75 C ( -40 to 167 F)
o o
Fau lt contact
Relay Relay o utput t o carry c apaci ty of 1A at 2 4 VDC
Pow er
Redund ant Inp ut powe r
Power co nsump tion( Typ. ) 15 Wa tts, 12- 48VDC /1.2A-0.3A
Ov erloa d curre nt prot ectio n
Rever se polarity pr otect ion
Pr esent
Pr esent o n termi nal blo ck
Phy sical Charac teristic
En closu re IP-30 A lumin um (non U L certi fied)
Di mensi on (W x D x H)
Weig ht (g) 10 60 g
Du al DC inp uts 12- 48VDC o n 6-pin termina l block
* Su pplie d by SELV sou rce evaluat ed by UL 61 010-1 o r 61010 -2-20 1 power s upply only.
* Fourni p ar la sou rce SELV évalué e uniqu ement p ar l'al iment ation U L 61010 -1 or 610 10-2- 201.
74 .3 (W) x 10 7.5 (D) x 1 53.6 (H )mm (2. 93x4.2x6.05 inch.)
Pr iorit y Queue s 4
Res et Function
Reset Bu tton < 5 se c: Sys tem reboot, > 5 sec : Fa ctory d efaul t
CE E MC (EN 55 024, EN 5 5032), FCC Pa rt 15 BEMC
War ranty
*NOTE : This function is avail able by reque st only
!
Up t o 2000mOp erat ing Alt titude
5 ye ars
!
Warning [AVERTISSEMENT]
Take into consideration the following guidelines before wiring the device
[Tenez compte des directrices suivantes avant de câbler l’appareil.]
1. Terminal block is mating with Plug and suitable for 12-24AWG. Torque value 4.5 lb-in.
[Le bornier est compatible avec les connecteurs et convient pour 12-24AWG.
Valeur de couple 4,5 lb-in.]
2. The temperature rating of the input connection cable should higher than 105°C
[La température de service nominale du câble d’entrée doit être supérieure à 105 °C]
* Indoor use and pollution degree II, it must be wiped with a dry cloth for clean up the device and label.
* Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un chiffon sec pour nettoyer
l'appareil et son étiquette.
* Do not block air ventilation holes.
* Ne bouchez pas les orifices de ventilation.
* If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.”
* Si l’appareil est utilise d’une maniere non specifiee par le fabricant, la protection qu’il apporte peut se
voir diminuee.”
* Shall be mounted in the Industrial Control Panel and ambient temperature is not exceed 75 degree C
* doit être monté dans le panneau de commande industriel et la température ambiante ne doit pas
dépasser 75 degrés C
Version 2.1
IES-3160
IES-3160 Industrial Managed Ethernet Switch
S W I T C H
I N D U S T R I A L
PWR Green On DC power on
PWR1 Green On DC power module 1 activated
PWR2 Green On DC power module 2 activated
R.M Green On Ring Master
Ring Green
On Ring enabled
Blinking Ring structure is broken (i.e. part of the ring is disconnected)
Fault Amber On Faulty relay (power failure or port disconnected)
10/100Base-T(X) Ethernet ports
LNK/ACT
with speed
Green
On Port link up
Blinking Data transmitted
Amber
On Full-duplex mode
Off Half-duplex mode
Blinking Half-duplex mode and collision occurred